XJ Schindler SL6000 series passenger elevator

A Schindler JV Company
SL6000 series passenger elevator
On sale ahead, and international synchronized.
A perfect melange of European top design of whole lift
system、high-efficiency power and comfort,
new humanity design of car of lift, much more condensed
systemic architecture, mix together European top con-
trolling system, SL6000 series passenger elevator shall be
taken more comfortable、calmly and environmentally. It
shall be much pleasured to take SL6000 elevator and also
a new European experience which explain the leading
technology in the world an the human feelings perfectly.

1
more professional, more lead.
This series adopt SCH5600 main controlling
systemic platform developed newly 、
condensed systemic architecture、mighty
anti-interference design and powerful calcula-
tion ability such that SL6000 series elevator is
so reliable and stable.

Mult-platform integrated system, condensed


architecture in peripheral, integrated master
control, supervisory control, intelligent
management, black box and other functions.
There is a huge breakthrough in elevator
intelligentialize.

Mighty anti-interference design, the military


level standard, modularity independent
isolated shielding technology, the capacity
and speed of communication have been
raised doubly so that the system is more
stable.

Control technology for absolute position of


car, supervise car position and calculate
operational site accurately to ensure users
of elevator are protected well .

Handling technology with low fault rate,


leading initiative protection, system can
reduce fault points, fault times and fault
level automatically so that users of elevator
can be protected most effectively.

2
SL6000 special six- fold safety protection technology

Safety protection for the door area


We do not worry about
accidents of dropping or cutting

Patent number: ZL 200910112744.1


In case the car moves at the moment of door opening,
elevator system can brake the car rapidly such that
users in the car are protected from cutting or slipping
accidents in advance and automatically.

Safety protection for non-door area


We do avoid
falling into the well accident caused by compulsorily door opening

Patent number: ZL 201020290935.5


When the car is in the non-door area, protection devices of
system shall lock the door of car tightly such that keep users are
at the safest place.

Standby energy-saving technology


We do reduce wasting
52% of power consumption when the elevator is standby

Patent number: ZL 201110229798.3


XJ Schindler has come true that electric energy transform
seamlessly between working status and non-working
status—in case the car is empty, elevator will be standby
with 47W power consumption; in case the car with load,
elevator will be awoken immediately and recover normal
operation status.

4
Absolute position controlling
We do resolve
landing wrong and confusion phenomenon
System supervise running state in real time, and calculate the
position of car and the data of running, intelligently protect
the safety of users. Chinese passenger elevator standard of
2014, current European passenger elevator standard.

AX530 specialist analysis system


We do have ability to
reduce 85% of keeping person in car accident
Analyse elevator data in real time, separate failure type of
safety level and unsafety level automatically, actualize no
keeping person in car.

Remote monitoring system


We do have more methods to
resolve the maintenance quality issue
Throroughly resolve maintenance problem so that maintainers
are always standby, discover and resolve elevator problem
at site first time, improve the quality of running. Implement
elevator remote failure prediction and warning, make users no
worry.

5
Digitized landing function, stopping comfortable and steady

Digitized tracking of elevator operating in whole operating process, calculate exact landing
position of elevator. Based on distance, adopt the closed cycle control method of speed and
distance, confirm operation curve according to current target distance, elevator is stopped
directly, the process of leveling is more steady、accurate and comfortable, the operating
efficiency is better.

The operation curve is produced according


V(m)

to distance of two points instead of setting


数字停靠曲线
in advance.
3.0 Through automatic diagnosis and revision
by feedback unit, system can calculate
2.0
positional signs accurately such that stop
1.0 the elevator.
普通停靠曲线
0.5

0.5 1 1.5 2.0 2.5 T(S)

operation curve diagramming of digitized landing

6
Sinusoidal servo door machine, door-opening and door-closing accurate and reliable
Combining the least achievements of servo door machine、angular speed and angular displacement
sensor, synchronous gate knife and synchronous drive match each other, constitute the newest
mechanical and electrical integration of direct drive door machine which has high performances. The
close-cycle control of speed、position、moment is come true. Door operation curve is not affected
with loading, the action of doors in closing process is self-adaption、steady、submissive、efficient
and accurate.

Landing and car doors with synchronous gate knife


V

同步伺服门机运行曲线 is completely synchronous, the process of door


closing and opening is controllable: accurate and
gentle;
High operation efficiency, fast speed, door-open-
ing and closing time 2.04s;
普通门机开门曲线 Sinusoidal drive, control more accurately, lower
failure rate;
0 T1 T2 T3 Close-cycle control, power self-adaption, ener-
T4 T
gy-saving about 65%, door opening and closing
noise 38 dB.
Operation curve diagramming of door opening

7
more humanity more international

Aseptic car, additional negative ion generator,


automatic ventilation system, sufficient
ventilation, the air in car is fresh and healthy.

Five car wall technologies for reducing noise,


traction machine with low noise, noise can be
lower than 43dB.

Preferable voice announcement, intellective


voice button, voice playing more easily.

Most comfortable light with 100 Lux, elegance


and comfort.

The height of car is 2350mm, suitable for public


place, more open space.

8
Lead technology for elevator without machine room

New generation technology for no machine room

Normal Machine Room


The design of well for no machine room elevator S6000 the building
without machine room
has been applied for patent, ultrathin traction
machine is installed on well wall, separated control-
ler located in well and overhead separately such
that controller is installed conveniently. Save cost of
one layer for contractor, especial well design is
suitable for a great deal of building structures,
maximize use space of buildings.

Slippery well operation system

XJS own patent slippery well operation system , including


high-efficiency guide shoes、wearable guide bush and the
self absorbing oil box, operating smooth, mass of oil is
moderate, no greasy dirt, and greener.

Ultrathin traction machine,lead the industry


The ultrathin traction machine designed for elevator
without machine room , is more suitable for being
installed in well; prepose the rotary encoder such
that testing and operating conveniently

10
Separated controller, save more space

The main controller is located in the well, and


auxiliary controller is located in overhead,
separately control for saving more well space.
Design resistance、connecting line and
components according to GB IEC standard.
The design can resist 300°high temperature,
the connecting line can not exceed 0.75mm²,
higher reliability.

Insulate vibration, reduce 30% noise

Particular isolated technology for noise, the


traction machine is located in special position
and isolated from car, vibration is guided to
the earth, reduce 30% noise, reduce noise
pollution caused by noise so that create a
quiet environment for users riding.
噪音导向地面

reduce 30% noise

11
XS01
Large-area lighting, comfort
and bright, powder coating
car walls, the color is elegant
and warm

Specification
Car walls Powder coating
Flooring DM-A16 homoge-
neous vinyl tiles
Car door Powder coating
Front wall Powder coating
Ceiling X70C

Indicator Text Mode LCD


Clear height in car 2350mm

This picture is digital simulation diagram, please kind prevail.

12
XS02
S/S hairless and Non-directioanl SS
match, harmonious and beautiful,
regular convex, details manifest taste.

Specification
Car walls S/S hairline
Flooring DM-A16 homogeneous
vinyl tiles
Car door Non-directioanl SS
Front wall Non-directioanl SS
Ceiling X73C

COP Incorporated into front panel


Indicator Text Mode LCD
Clear Height in car 2350mm

This picture is digital simulation diagram, please kind prevail.

13
XS03
Designed for re-decoration,
correspond to other decoration
in car, manifest luxury.

Specification
Car walls powder coating
Flooring DM-A21 homogeneous
vinyl tiles
Car door Non-directioanl SS
Front wall Non-directioanl SS
Ceiling X72C

COP Incorporated into front panel


Indicator Text Mode LCD
Clear height in car 2350mm

This picture is digital simulation diagram, please kind prevail.

14
XS04
Grains are straight and forceful,
space is open, pleasured and
comfort.

Specification
Car walls non-directional S/S
Etching S/S
Flooring DM-A16 homogeneous
vinyl tiles
Car door non-directional S/S
Front wall non-directional S/S
Ceiling X71C

COP Incorporated into front panel


Indicator Text Mode LCD
Clear height in car 2350mm

This picture is digital simulation diagram, please kind prevail.

15
Passenger elevator that responsible for rescuing
——For your and other people’s safe, please equip rescue elevator

Care your and other’s safe and health, XJ Schindler fulfill social responsibility together with you. The
rescue elevator designed for building structure makes emergent rescue to be convenient.

Special space design, more suitable for delivering stretcher

Large depth design Large door opening width design

Counterweight is at the side of car, Counterweight is deside the car, broaden


m,car space,
emphasize car depth design, depth can width can be 2100mm, width of door opening can be
be 2100mm, convenient for delivering 1300mm, suitable for delivering stretcher from side
stretcher.

display rescuing
signal on hall call
rescue system*
11 Direct delivering function: Elevator can get to any landing quickly on
Rescue which users start up “rescue” function. In case the “rescue” function
8
When rescue operating,
is started up, elevator will not accept other request, operated as a quick
7 elevator will not respond special direct access and complete rescue mission in the most short
Rescue other calls, get to target
floor directly time, After completing the mission, the system will recover normal
5 condition.
display rescuing
signal on hall call
direct arriving fast

4 Door-opening & closing wait function: Special door-opening&closing


wait function is designed for rescue elevator, when it is rescue situation,
start up door-opening wait to be convenient for rescue and safe access.
1
Emergency system for power cut*
For completing rescue mission, users can choose special emergency
system, once power is cut, begin the emergency power system , then car
will lands to the nearest land.

New version of the residential design standard


According to the GB50093-2011 (residential design standard) which is
published by Ministry of Housing and Urban-Rural Construction of the
people’s Republic of China and State Administration of Quality
Supervision Inspection and Quarantine, 12-storey or more than 12
Notes: The rescue system、 emergency system for storeys residential buildings shall be installed at least two elevators which
power cut、stretcher are selectable functions. one of them shall be rescue elevator can hold the stretcher.

16
XS06
Special design for residential building
increase width of door opening,
convenient for delivering stretcher

Specification
Car walls S/S hairline
Flooring DM-A16 homogeneous
vinyl tiles
Car door S/S hairline
Front wall S/S hairline
Ceiling X75C
COP Incorporated into front panel
Indicator Text Mode LCD
Clear height in car 2350mm

This picture is digital simulation diagram, please kind prevail.

18
Incorporated into front operating panel
CZP-22
Operating panel indicator

Dot matrix LED digital display Text mode LCD display TFT true color display
( selectable ) (standardized) (selectable )
High brightness and long life span Dear handwriting and Colorful and fresh, true effect
great wide vision

TFT display system Multimedia system


(selectable ) (selectable )
TFT true color display screen, play multiple true color display, be able to play multiple types of
types of picture dynamically video such as rmvb、rm、avi、mpg、mp4 and so
on. Also can play video files made by customers

Handicap Sub COP ZZP-22

Text mode LCD horizontal indicator Dot matrix LED dynamic indicator Dot matrix LED indicator
(selectable ) (selectable ) (selectable )
Clear handwriting High brightness and long life span rolling display text、floor、ride direction、
appointed information by users

19
Ultrathin hall call

HT-19JT2 (selectable)
HT-19JD (standardized)
Dot matrix LED display Text mode LCD display
S/S mirror plate S/S mirror plate

注:首层为标配

Handrail (selectable)

FS-11WF round-curve handrail,S/S hairline finishing

FS-11WJ round-curve handrail, S/S mirror finishing

FS-WFB flat-curve handrail, S/S hairline finishing

Lantern (selectable)

DZD-JF DZD-JF

Quadrate crystal lantern DZD-JS Vajrasana crystal lantern


S/S mirror plate S/S mirror plate
Ceiling pattern

X70C X71C X72C X76C

以上不适用于救援电梯轿厢

Flooring pattern

DM-A21 DM-A22 DM-A16 Wooden flooring


Homogeneous vinyl tiles Homogeneous vinyl tiles Homogeneous vinyl tiles (selectable, kind prevail)

Car walls

Powder coating silvery S/S hairline S/S etching Non-directional S/S

21
SL6000 Passenger Elevator Standard Layout Drawings (Small MR)

Motor Room Height ≥2200
Hook MR Width (AM)
Power Switch
(By others)
Light Switch
R1 (By others)
500
50

A A
Guiderail      5000

R5
Overhead Height OH
2500

MR Depth (BM)
Hoisting Hook Above
300

Exhaust Fan
     Guide Rail Brachet Span 2000mm

A A (By others)
R2
  Guide Rail  5000 X n=

Motor Room Plan


Total Height

Hoistway Depth (BH)
Cage Depth (BB)
Min Floor Height ≥2600
2000
5000

Door Opening(JJ)
Pit Depth (PP)

Structure Opening (SO)


1000

Cage Size (AA)


Guide Rail Bracket
Guide Rail

Hoistway Width (AH)


R3 R4

Elevation Plan Hoistway Plan

22
SL6000 Passenger Elevator Standard Specification(Small MR)

Entrance Door Machine room


Speed Load Cage Size Hoistway Size Pit Depth Overhead MR Height
Model Opening Opening Size Height
m/s Kg JJ SO AA×BB AH×BH AM×BM PP OH HM
9000-KT-06-10 1.0 1500 4400 2200
9000-KT-06-15 1.5 630 800 950 1400×1100 1950×1750 1950×1750 1600 4500 2200
9000-KT-06-17 1.75 1700 4800 2200
9000-KT-08-10 1.0 1500 4400 2200
9000-KT-08-15 1.5 1600 4500 2200
9000-KT-08-17 1.75 800 800 950 1400×1350 1950×2000 1950×2000 1700 4800 2200
9000-KT-08-20 2.0 1800 5000 2200
9000-KT-08-25 2.5 2000 5200 2200
9000-KT-10-10 1.0 1500 4400 2200
9000-KT-10-15 1.5 1600 4500 2200
9000-KT-10-17 1.75 1000 900 1050 1600×1500 2200×2200 2200×2200 1700 4800 2200
9000-KT-10-20 2.0 1800 5000 2200
9000-KT-10-25 2.5 2000 5200 2200
9000-KT-11-10 1.0 1500 4400 2200
9000-KT-11-15 1.5 1600 4500 2200
9000-KT-11-17 1.75 1150 1100 1250 2000×1350 2600×2050 2600×2050 1700 4800 2200
9000-KT-11-20 2.0 1800 5000 2200
9000-KT-11-25 2.5 2000 5200 2200
9000-KT-13-10 1.0 1500 4400 2200
9000-KT-13-15 1.5 1600 4500 2200
9000-KT-13-17 1.75 1350 1100 1250 2000×1500 2600×2200 2600×2200 1700 4800 2200
9000-KT-13-20 2.0 1800 5000 2200
9000-KT-13-25 2.5 2000 5200 2200
9000-KT-16-10 1.0 1500 4400 2200
9000-KT-16-15 1.5 1600 4500 2200
9000-KT-16-17 1.75 1600 1100 1250 2000×1750 2600×2500 2600×2500 1700 4800 2200
9000-KT-16-20 2.0 1800 5000 2200
9000-KT-16-25 2.5 2000 5200 2200

Work to be done by building contractors


1 Prepare hoistway with proper framing and enclosure with either concrete, reinforced brick or steel structure to carry the sufficient loading

2 Provide and/or cut all necessary holes, chasing, and openings for landing doors, indicators, hall calls installation, and making good after installation

Hoistway 3 Reserve the reinforced steel bars for jamb and transom fixation

  4 Provide suitable pit of water-proofing and teem concrete after installation of pit buffer, no water, no osmosis.

5 Supply hoistway service door if non-stop distance more than 11m.

1 Cut floor openings with proper measures to prevent water flowing in

2 Provide hoisting hook for with proper loading requirements

Machine
3 Construct the concrete machine bed platform with sufficient loading and embedded steel plate.
room 4 Lay spool and thread lines for machine electrical power and light sources from the power distribution room to machine room.
 
5 Supply and install monitored and intercom cables from machine room to guard house.
Supply and install lights and single phase AC220V10A three-hole electric outlet in machine room (The lowest illuminance shall not be less than
6 200Lx of machine room).
1 Machine room ambient temperature 5℃ ~ 40℃

2 Machine room opposite humidity <=85% (at 25℃)

Entironment 3 Provide fans、ventilating windows, keep air flowing.

and power 4 Power supply: three phase AC 380V 50Hz (three phase five line), the wave range of voltage is not exceed 70%.
source
5 Light supply: singe phase 220V 50Hz (light supply、power supply shall be laid all alone)

6 Height above sea level: 3000m ( In case it is higher than 3000m, XJ Schindler shall change the design)

7 The earth line adopt the way of three phase five line, ensure the earth line and zero line are separate all along( the earth resistance of earth line
shall not exceed 4Ω)

23
SL6000 Passenger Elevator Standard Layout Drawings ( No Machine Room)

Hook
300

Ventilating window Hoistway Width (AH)
50

500

Hoistway Depth (BH)
2500

Overhead Height OH

Cage Depth (BB)
1300

Door Opening (JJ)

Structure Opening (SO)


Just set up controller Cage Size (AA)
 in overhead
     Guide Rail Brachet Span 2000mm

Hoistway Plan
Total Height
 5000 X n=

Hoistway Width (AH)

R1

Hoistway Depth (BH)
Top Hook Shadow Position

R4
R1 R2
2000

R2 R3
1000-5000

Pit Depth (PP)
Guide Rail Bracket
1000
Guide Rail

Elevation Plan Pit Plan


SL6000 Rescue elevator standard layout Drawings

Entrance Door
Speed Load Opening Opening Cage Size Hoistway Size Pit Depth MR Height
Model
m/s Kg JJ(centre opening) SO AA×BB AH×BH PP OH

9000-WT-06-10 1.0 1600 4000


9000-WT-06-15 1.5 630 800 950 1200×1300 1900×1700 1800 4300
9000-WT-06-17 1.75 1800 4400
9000-WT-08-10 1.0 1600 4000
9000-WT-08-15 1.5 800 800 950 1300×1500 2000×1900 1800 4300
9000-WT-08-17 1.75 1800 4400
9000-WT-10-10 1.0 1600 4000
9000-WT-10-15 1.5 1000 900 1050 1400×1600 2100×2000 1800 4300
9000-WT-10-17 1.75 1800 4400
9000-WT-11-10 1.0 1800 5000
9000-WT-11-15 1.5 1150 1100 1250 1400×1800 2600×2300 1800 5200
9000-WT-11-17 1.75 1800 5400
9000-WT-13-10 1.0 1800 5000
9000-WT-13-15 1.5 1350 1100 1250 1400×2100 2600×2600 1800 5200
9000-WT-13-17 1.75 1800 5400
9000-WT-16-10 1.0 1800 5000
9000-WT-16-15 1.5 1600 1100 1250 1400×2400 2600×2900 1800 5200
9000-WT-16-17 1.75 1800 5400

Work to be done by building contractors

1 Prepare hoistway with proper framing and enclosure with either concrete, reinforced brick or steel structure to carry the sufficient loading

2 Provide and/or cut all necessary holes, chasing, and openings for landing doors, indicators, hall calls installation, and making good after installation

Hoistway 3 Reserve the reinforced steel bars for jamb and transom fixation

  4 Provide suitable pit of water-proofing and teem concrete after installation of pit buffer, no water, no osmosis.

5 Supply hoistway service door if non-stop distance more than 11m.

Provide ventilating hole for enclosed hoistway ( ventilating hole always be the top or bottom of hoistway), the area of hole shall not be less
1 than 1% of horizontal area of hoistway and prevented by protective net.

Provide independent power supplier according to the requirement of technology parameter table: this power supplier shall be provided with
2 protected switch and be locked, the wave range of voltage shall be ± 7%, earth line adopt grounding way of three phase five line, the zero line
and earth line of power supplier shall be separated and earth resistance shall be exceed 4Ω. This power supplier shall be pulled to overhead.
Entironment
and power
source Establish rescuing duty room, lay a six core cable to the emergency control panel in overhead for each elevator( suggest shielding/bright twisted-pair),
3 each core shall ne be less 0.75 mm².

4 Power supply: three phase AC 380V 50Hz (three phase five line), the wave range of voltage is not exceed 70%.

5 Light supply: singe phase 220V 50Hz (light supply、power supply shall be laid all alone)

6 Height above sea level: 3000m ( In case it is higher than 3000m, XJ Schindler shall change the design)

25
SL6000 Rescue elevator standard layout Drawings
*2T Hook 2700
1120 780
910 650
Fan 600

R5

2500
B B

500
50

A
260 520
300~2500

Overhead Height OH
Guiderail  ≤5000

220 H
400
2600

80
R1 R2

2-Ø
Electrical Cabinet
Hook Shadow Position

1305
5孔-200×200

290
*Power Box
*Socket
     Guide Rail Brachet Span 2000mm

≥1000×2000
  Guide Rail  5000 X n=

Motor Room Hole Plan


Total Height

AM 1900

Overspeed Governer
Min Floor  Height ≥2700

2600



Electrical Cabinet
300~400
5000

Pit Depth PP
Guide Rail Bracket
1000

R3 R4
Guide Rail

≥1000×2000

Elevation Plan Motor Room Plan

SL6000 Rescue Elevator standard Specification


Entrance Door Overhead
Model Speed Load Opening Opening Cage Size Hoistway Size M?C Size Pit Depth Height MR Height
m/s Kg JJ SO AA×BB AH×BH AM×BM PP OH HM
2200
1600 2200
2200
2200
2000 5200 2200
2200
1600 2200
1000 900 1050 1100×2100 2200
2200
2000 5200 2200

26
SL6000 Passenger Elevator Standard Function
Number Function Description

1 absolute position control Through car location technology, come true elevator not drop floor controlling, ensure elevator operated reliable.

When there is nobody take a ride, elevator get into standby situation, except the buttons on hall
Standby energy-saving
2 calls are light, other parts of whole elevator don’t waste energy, standby power is less than
technology 50VA. If person(s) uses elevator, it will recovery normal instantly.
System collects hall/car call signal from COP and hall calls, automatically arrange the responding
3 Selective Collective Control sequence according to the current running position and direction, and respond on every individual
registered call.
The driver manage selecting stop floor、responding of hall call、door closing and opening and so
4 Driver control
on, ensure ride direction priority.

5 Power on auto open door After each time of power on, if the car is in the door area, car door will open automatically.

6 Auto door closing time delay When car door is opened completely, hold door open situation for 2-5 seconds, then automatically

7 Door holding time adjustment Door open holding time can be manually adjusted to prolong or shorten door open time.

When the door cannot be fully closed within pre-designal period, elevator tries to close the door again.
8 Door close fault alarm
If fail to close for more than 6 times, activate the alarm signal and set to faulty mode.
When all doors are closed and locked, elevator can run. If in the process of running, the interlock is
9 Door interlock protection broken or shocking, elevator will get into protection situation instantly.
Special door operation Special 10 protections for door operation, achieve door-area initiative safety protection, avoid appear-
10
protection ing accidents when the door is operating.

11 Door open in hall When call button is pushed, landing door opens automatically after elevator stop and level.

In automatic status, when door is holding opening, press the door close button can make the door
12 Door close button
respond to close action instantly, close the door in advance.

13 Auto open door When the car is operated automatically, open car/landing door automatically when car ride to target floor.

14 Inspection operation After activation, elevator un up and down at inspecting speed, convenient for inspector to use.

In non-inspection status, and elevator stops out of the leveling zone. As long as comply with the require-
Low speed self save
15 ment of start-up safety, elevator automatically moves to level zone at low speed to open door and release
operation passengers.
Before elevator operates at high speed, start up systemic well self-learning function to learn all kinds data in
16 Well self-learning the well(landing height、protection switch position、deceleration switch position and so on), keep these
operation data forever.

Hall call button When a hall call button signal keeps ON for more than 20 seconds, the elevator determines this button is
17
self-diagnose faulty and isolated it from system and twinkle corresponding hall indicator to alarm.

If the car stops between two layers caused by power cut or electric fault, once power supply recovery, car
18 Power on self-recovery
automatically moves to the level position, recover operation.

There is WDT protection on main board, when elevator is inspected a CPU fault or program fault, WDT
19 WDT initiative protect
circuit forces main controller output point to close, reset CPU.

The multi-beam system forms a multi-beam protection net, if be touched, the action of door closing stops
20 Multi-beam protection
instantly, automatically open the door, protect passengers’ safety.

In normal operating process, controller inspects that the speed feedback from encoder is more than 115%
21 Overspeed protection of rated speed, if hold this status for 500 ms, elevator will decelerate and stop. Above activity is repeated
two times and without revise, main controller doesn’t output operating signal any more and fault alarm.

Once it is overload, door is not close and overload light burning, buzzer noisy, indicates overload informa-
22 Overload protection
tion, elevator can not be start up.

27
Number Function Description

Backward operation When inspection operating, system finds that operating direction of car is not conformity with directive
23 protection direction for three seconds, elevator will be stopped and alarm.
System inspects car operating speed by AB encoder, if in actual time, operating speed of motor is not
24 Antiskid protection conformity with operating speed of car, determines the wire rope slips, brake and stop the car instantly,
start up five level fault status.
When elevator operates to the terminal of travel, if the speed is not decelerated to predict speed,
25 Anti-over travel protection
system force the car to decelerate, protect car operating safety.

Contactor contact System inspect if the activity of motor circuit contactor is reliable or not, if there is finding, stops the car
26 inspection protection and get into inspection status, finds the clear type of fault.

27 safety circuit protection If any part of car breaks down, the safety circuit breaks and elevator stops operating instantly.

operating overtime When elevator operating time is more than total time of whole travel operation, elevator stops operat-
28 protection ing and alarm fault.
After detect the restriction site switch, stop the elevator operating instantly, then operates the car in
29 Restriction site protection
negative direction, recover normal operating after car level and door open.

30 The limit protection After detect the limit protection switch, whole system will be in protection status.
System can monitor brake actions, shutdown the system if the brake doesn’t act according to the
31 Braking protection request.
If system detects inerter fault signal, brake the car peremptorily, and avoid elevator operating, when the
32 Inverter fault protection
fault recovers the car recovers operation too.
Encoder signal lose In operating process, detect the signals of encoder lose or pulse count is less, automatically stop the car
33
protection and protect.
When the fireman switch is turned on, the elevator returns to the designated floor and ready for fireman
34 Fireman Operation
use.
When the car is stop, system detect there is pulse count for three seconds, determine the car is slipping,
35 Car slip alarm
activates alarms and stops running in the event of fault.

If the car breaks down and stops in the non-door area, the elevator automatically goes to the level zone
36 Nearest landing operation
and open door at low speed in normal safety circuit.

37 Overload bypass When car is fully loaded, it will only responds to car calls and bypass all hall calls.

For avoid elevator operating empty, Through logical decision of load, deal with abnormal directives,
38 Anti-nuisance function
avoid practical joke and error directive in car.

No land floor setting According to the requirement of users, set the floor which the car doesn’t land, the car will not stop for
39
selected floor.

after activation, elevator responds all inscribed directives, then return to designed floor, start up energy
40 Lock Service conservation function, turn off the light in car and light up the hall stopping switch signal.

When door fail to open at a period of 8 seconds, elevator moves to the nearest landing to release
41 Landing change passengers.
Automatic returning
42 function
After all the calls have been served, the elevator returns to the pre-designated standby floor.

An interphone system among car, machine room, car top, pit and guard house is provided for emergen-
43 5-way communication cy communication.( The cables are laid by users)

In the process of car decelerating and leveling, the bell is noisy to remind passengers in the car or in the
44 Arrival bell hall that the car is leveling.

45 Car emergency lighting An emergency light will be activated automatically when power failure occurs.

28
SL passenger elevator selectable function

Number Function Description

With elevator operates to level zone, the elevator can open the car/landing door before stop
1 Advance opening
during on landing zone low speed movement.
Fully automatic operation used for a two elevator system. Calls are responded to by whichever
2 Duplex control car that can serve the call faster. When there is no call, one of the cars will standby at the
starting floor while the other car stops at the pre-designated floor.
A group control system is used when there are more than two elevators operating in a group(up
3 Group control to 16 elevators). Using XJ group control dispatching algorithm, system reduces waiting time by
computing forecasts of waiting time and distributing them evenly among all cars controlled.

Multi-beam door sensor and Double protection, If a passenger makes contact with multi-beam sensor or door safety edge
4
door safety edge protection protection, the door will stop closing and re-open door.

car wall protection plate During the period of users moving in the building or decoration, add the protection plate on car
5
walls so that the walls will not be broken, the plate can be removed after this period.

Power cut emergency When power is cut, changes to spare power supplier automatically, moves to the nearest floor
6
rescue means according to designed system, open door and release passengers.

If the car stops in non-door area cause by fault, the car door is locked by system to avoid passen-
7 Car antitheft door system
gers theft the door, protect passengers’ safe.

MiniVCap system interface Reserve the interface for miniVCap, meet the requirement of supervising elevator.(The cable is
8 reserved( in car or in uptown) supplied and laid by users).

When the car is operating down, change the potential energy to electric energy, through
9 Energy recovery rectification, change the produced direct current to electric energy which match the grid voltage
and re-give to grid voltage so that other electric devices can use it, save energy.
Present standard message information is announced to passengers in car or in the hall through a
10 Voice Synthesizer
voice synthesizer.
Provide the lantern if users select, to remind waiting passengers car arrives and the direction of
11 Lantern
operating.
Earthquake emergency
12 When a earthquake is detected, the elevator will stop at the nearest floor.
operation

13 Elevator air-con Air-conditioner can be equipped into car cage.

Scheduled startup/
14 Elevator automatically starts up and shuts down on the preset scheduled time.
shutdown service
Building elevator supervise
15 Provide elevator operating status signals to building intellective management system.
interface
Provide COP with a card reader, passengers shall swing card first, after that, passengers can
16 IC card
operate the elevator.

17 Car LCD display Can provide true color LCD indicator, show floor information and operating status clearly.

When there is a fault in safety circuit, adopt an emergency measure, (short some parts of safety
18* Emergency electric driven
circuit) so that release passengers in shortest time, recover normal operation.

*SL6000 passenger elevator without machine room standardized function

You may need more, please contact XJ Schindler!

29
提示:样本中轿厢均为数字仿真图片,实际产品颜色和材质与印刷品稍有差异;
由于产品持续创新,样本中图片表达、文字陈述和数据请以实物为准。

V42304102

国家火炬计划 ISO9001质量 OHSAS18000职业 ISO14001环境 国家康居示范工程 全部采用国际 欧洲CE认证 新加坡电梯防火 中国人民保险公司


重点高新技术企业 管理体系认证 安全健康体系认证 管理体系认证 选用节能产品 标准产品 安全门认证 电梯质量承保

You might also like