Installation Instructions schneider-electric.

com | 1

SmartX Living Space Resistive Temperature Sensor


TM

SXWSATXXXSLX

Product Description Features


SmartX sensors are a family of living space sensors for use • Contemporary, sleek housing, same form factor as SmartX

FT
with SmartX IP controllers. SmartX sensors are available in communicating sensors
communicating and non-communicating versions. Commu- • Low cost conformance part
nicating versions are powered and connect to the SmartX IP • 10K Type 3 thermistor
controller using the RJ-45 Sensor Bus. The SXWSCBXSELXX • Two-wire resistive device
non-communicating version uses a resistive two-wire connec-
tion to connect to an I/O port of the SmartX IP controller.
The SXWSCBXSELXX with its reliable 10K Type 3 thermistor
and the same look and feel as communicating SmartX sensors,
provides a low cost option for measuring temperature in a living
A
space application.

Applicable Documentation
Document No. Title Description
DR

F-28090 SmartX Living Space Sensor Base Installation instructions for all base variants
F-28091 SmartX Living Space Sensor Blank Cover Installation instructions for blank cover without occupancy sensor
Installation instructions for 3-button covers with and without occu-
F-28092 SmartX Living Space Sensor Button and Occupancy Covers
pancy sensors and blank cover with occupancy sensor
Installation instructions for touchscreen models with and without
F-28093 SmartX Living Space Sensor Touchscreen Cover
occupancy sensors
F-28094 SmartX Living Space LCD Temperature Sensor LCD temperature sensor base and cover installation instructions

USA: +1 888-444-1311
Europe: +46 10 478 2000
Asia: +65 6484 7877
www.schneider-electric.com

© 2017 Schneider Electric. All rights reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. November 2017
Z207554-0A nk

Installation Instructions schneider-electric.com | 2

Available Products
SmartX Combination Base/Cover Sensors
SmartX System Bus Resistive Only
Model Number Description Temp RH CO2 Cover (Communicating) (Non-communicating)
SXWSATXXXRXX* Sensor, Temp, 10K T3, No Comms, Cover Plate X Included X
SXWSATXXXSLX Sensor, Temp, LCD, SPS, PBO, Cover Plate X Included X

SmartX Sensor Bases


SmartX System Bus
Model Number Description Temp RH CO2 Cover (Communicating)
SXWSBTXXXSXX Sensor Base, Temp X Not Included X
SXWSBTHXXSXX Sensor Base, Temp, Humidity X X Not Included X
SXWSBTXCXSXX Sensor Base, Temp, CO2 X X Not Included X
SXWSBTHCXSXX Sensor Base, Temp, Humidity, CO2 X X X Not Included X

SmartX Covers**
61 mm (2.4”) Occupancy Sensor
Model Number Description Color Touchscreen Override Setpoint (PIR)
SXWSCDXSELXX Cover Plate, User Interface, Basic X X X

FT
SXWSC3XSELXX Cover Plate, Pushbutton Ovrrd, Setpoint Slider X X
SXWSCBXSELXX Cover Plate, Blank Cover
SXWSCDPSELXX Cover Plate, User Interface, Basic, Occ X X X X
SXWSC3PSELXX Cover Plate, Pushbutton Ovrrd, Setpoint, Occ X X X
SXWSCBPSELXX Cover Plate, Blank Cover, Occ X
* Covered by these installation instructions.
** SmartX covers will not work with combination base/cover sensors.

Specifications Thermistor Table


A
Temperature Sensor °C °F Resistance (Ω)
Type 10K Type 3 thermistor 0 32 29,575
Accuracy ±0.2 °C (±0.36 °F) typical 5 41 23,504
Operating Environment 10 50 18,809
DR

Operating temperature 0 to 50 °C (32 to 122 °F) 15 59 15,146


Operating humidity 20 68 12,271
0 to 95% RH, non-condensing
range
25 77 10,000
Housing material High impact ABS plastic
30 86 8,195
Not suitable for wet locations.
Mounting location
For indoor use only. 35 95 6,752
Wiring 40 104 5,592
Two screw terminals 18-22 AWG, two-wire thermistor 45 113 4,655
Regulatory Information 50 122 3,893
UL 916,
European conformance CE:
EN50491-5-2
EN60730-2-9
EN61000-6-3
Agency approvals EN61000 Series - industrial immunity
standard
FCC Part 15 Class B, flammability rating
UL 94 V-0, REACH, Green Premium,
RCM (Australia), ICE5-003 (Canada),
EAC (Russia)

USA: +1 888-444-1311
Europe: +46 10 478 2000
Asia: +65 6484 7877
www.schneider-electric.com

© 2017 Schneider Electric. All rights reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. November 2017
Z207554-0A nk

Installation Instructions schneider-electric.com | 3

Precautions Dimensions mm (in.)


SmartX Resistive Temperature Sensor Base with
DANGER Cover Installed
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC
FLASH
• Follow safe electrical work practices. See NFPA 70E in the
USA, CSA Z462 in Canada, or applicable local codes.
• Read and understand the instructions before installing the
product. Follow the instructions during installation.
• Installation, wiring, testing or service must be performed only by
qualified persons in accordance with all applicable codes and 115
regulations. (4.5)

ER
• Do not use the product for life or safety applications.
• Do not install the product in hazardous or classified locations.

LD
• Do not exceed the product’s ratings or maximum limits.
• The product may use multiple voltage/power sources.
O
• Turn off ALL power supplying equipment before working on or

EH
inside the equipment.
• Use a properly rated voltage sensing device to confirm that all
power is off.
C
LA
85 24
• Do not depend on the product for voltage indication. (3.3) (0.9)

P
• Products rated only for basic insulation must be installed on
insulated conductors.

FT
• Current transformer secondaries (current mode) must be
shorted or connected to a burden at all times. Functions
• Remove all wire scraps and tools, replace all doors, covers and The SXWSCBXSELXX measures temperature in living space
protective devices before powering the equipment. applications. It provides a resistive output to an I/O port on a
Failure to follow these instructions will result in death or SmartX or Continuum controller.
serious injury.
A qualified person is one who has skills and knowledge related to the
construction and operation of this electrical equipment and System Architecture
installations, and has received safety training to recognize and avoid MP-X Controller and Non-Communicating Sensors
the hazards involved. NEC Article 100
A
If this product is used in a manner not specified by the MP-X Controller
manufacturer, the protection provided by the product may be SXWSATXXXRXX
impaired. No responsibility is assumed by Schneider Electric for Temperature-only Sensors
any consequences arising out of the use of this material.
DR

Each sensor uses an I/O port on the controller.


Maximum number of inputs varies by controller type.

USA: +1 888-444-1311
Europe: +46 10 478 2000
Asia: +65 6484 7877
www.schneider-electric.com

© 2017 Schneider Electric. All rights reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. November 2017
Z207554-0A nk

Installation Instructions schneider-electric.com | 4

Installation 5. With sensor base fully installed, align top of cover to


1. Position the sensor vertically on the wall 1.35 m (4.5 ft.) mounting tabs on top of sensor base. Swing cover down-
above the floor with the “UP” arrow facing upward. Locate ward until it latches at the bottom.
away from windows, vents and other sources of draft. If
possible, do not mount on an external wall, as this may
cause inaccurate temperature readings.

6. Install locking screw to secure cover in closed position.

2. Pull 18 or 22 AWG two-conductor cable(s) through the hole


in the backplate.

FT
3. Mount the backplate onto the wall using the screws
A
provided.
DR

Six screw holes


available. Use a
minimum of two for
secure mounting.

4. Connect the wires to the termistor terminals. Do not


over-tighten the screws.

USA: +1 888-444-1311
Europe: +46 10 478 2000
Asia: +65 6484 7877
www.schneider-electric.com

© 2017 Schneider Electric. All rights reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. November 2017