You are on page 1of 2

APPENDIX 30

RULES FOR DRILLED HOLES NOT PENETRATING


THROUGH VESSEL WALL

30-1 SCOPE hole and an unreinforced opening shall satisfy the


requirements of UG-36(c)(3)(c) and (c)(3)(d).
Partially drilled radial holes in cylindrical and spheri-
30-2(c)(2) Partially drilled holes shall not be placed
cal shells may be used provided they are 2.0 in. (51 mm)
within the limits of reinforcement of a reinforced
or less in diameter and the shell diameter to thickness opening.
ratio D/t ≥ 10. The acceptance criterion for the depth 30-2(d) The outside edge of the hole shall be cham-
of the hole is the plot of the ratio tmin/t versus d/D fered; for flat bottom holes, the inside bottom corner
that is on or above the curve in Fig. 30-1. of the hole shall have a minimum radius of the lesser
of 1⁄4 in. (6.4 mm) or d/4.
30-2(e) These rules are not applicable to studded
connections (see UG-43) and telltale holes (UG-25).
30-2 SUPPLEMENTARY
REQUIREMENTS 30-3 NOMENCLATURE
In addition, the following conditions shall be met. Symbols used in this Appendix are as follows.
30-2(a) The minimum remaining wall thickness tmin Dp vessel inside diameter, in. (mm)
shall not be less than 0.25 in. (6.4 mm). Pp design pressure, psi (kPa) (see UG-21)
30-2(b) The calculated average shear stress, ␶ p Sp maximum allowable stress value, psi (kPa)
Pd/4tmin, in the remaining wall shall not exceed 0.8S. dp diameter of drilled hole, in. (mm)
30-2(c) tp nominal thickness in corroded condition, in.
30-2(c)(1) The center line distance between any (mm)
two such drilled holes or between a partially drilled tminp remaining wall thickness, in. (mm)

489

COPYRIGHT American Society of Mechanical Engineers


Licensed by Information Handling Services
Fig. 30-1 2001 SECTION VIII — DIVISION 1

FIG. 30-1 THICKNESS RATIO VERSUS DIAMETER RATIO

490

COPYRIGHT American Society of Mechanical Engineers


Licensed by Information Handling Services

You might also like