You are on page 1of 4

Diagnostic Scan

Relatório de diagnóstico de veículos


Oficina:
Endereo:
Telefone:
O email:
VIN: WDCBB22E09A454743
Modelo do ano:
Marca: Mercedes
Veículo 164.122 - ML 320/350
Milhagem: 98188km
Verso do software do veículo: V49.40
Verso de aplicao de diagnóstico: 1.00.037
Tempo de teste: 2021-04-22 09:46:41
Caminho de diagnóstico: Procurar automaticamente
Inspection Result
Diagnostic Result
Falha ( 15 )
TCM - Transmission (2) Anormal
Control Module
C126 [(216/221)No CAN message was received from control Armazenado
unit N80(Steering column module).] or [One or more
messages from control unit N80(Steering column module)
are not available on the CAN bus.]
C002 CAN controller: CAN bus OFF NOTE In the case of the Armazenado
fault 'Bus OFF' the control module is isolated from the CAN
bus because of a major communication fault.
ISM - Intelligent servo (1) Anormal
module
1944 No CAN message was received from control unit Armazenado
N80(Steering column module). Current symptom : The
selector lever cannot be moved out of position 'P'.
ECM - Engine Control ( 14 ) Anormal
Module(CDI)
2249-4 Check component G2(generator). Mechanical fault Armazenado
2021-1 Monitorizao da presso do trilho através da válvula Armazenado
de controlo de presso. A presso do trilho é demasiado baixa.
2047-1 Monitorizao da presso do trilho através da válvula Armazenado
de controlo do volume. A presso do trilho é demasiado
baixa.
2017-1 Monitorizao da presso do trilho através da válvula Armazenado
de controlo do volume. A presso do trilho é demasiado
baixa.
2359-1 Verifique o sistema 'Controlo da presso da carga'. Armazenado
Presso auxiliar demasiado baixa
2209-1 [(203/209/463)No CAN message was received from Armazenado
control unit N47-5(ESP and BAS control module).] or [No
CAN message was received from control unit N47-5(ESP
control unit).]
2210-1 [(164/251)No CAN message was received from Armazenado
control unit A80(Intelligent servo module for DIRECT
SELECT).] or [No CAN message was received from control
unit N15/5(Electronic selector lever module control unit).]
2243-1 No CAN message was received from control unit Armazenado
N93(Central gateway control unit) or N73(EIS [EZS] control
unit).
2138-4 Glow plug Cylinder 6 Open circuit Actual e
armazenado
2136-4 Glow plug Cylinder 4 Open circuit Actual e
armazenado
2135-4 Glow plug Cylinder 3 Open circuit Actual e
armazenado
2134-4 Glow plug Cylinder 2 Open circuit Actual e
armazenado
2133-4 Glow plug Cylinder 1 Open circuit Actual e
armazenado
2213-1 No foi recebida nenhuma mensagem CAN da Armazenado
unidade de controlo N80 (Módulo da coluna da direco)
ESP - Electronic stability ( 6 ) Anormal
program
5996 Verifique o componente N49(Sensor do ngulo da Armazenado
direco).
5020 Chassis CAN bus : CAN controller: CAN bus OFF Armazenado
5556 No CAN message was received from control unit Armazenado
N93(Central gateway control unit).
5035 No foi recebida nenhuma mensagem CAN da unidade Armazenado
de controlo N80 (Módulo da coluna da direco)
7250 No foi recebida nenhuma mensagem CAN da unidade Armazenado
de controlo N80 (Módulo da coluna da direco)
7266 Speedtronic occasionally nonfunctional Armazenado
RevETR_LF - Left front (5) Anormal
reversible emergency
tensioning reactor
5316 Falha na comunicao CAN com a unidade de controlo Armazenado
N80(Módulo da coluna da direco).
5346 CAN message from control module N80(Steering Armazenado
column module) is faulty. Steering angle
5350 CAN message from control module N80(Steering Armazenado
column module) is faulty. Steering angle
5318 Fault in CAN communication with control unit Armazenado
N93(Central gateway control unit).
5060 A comunicao CAN tem falha. Armazenado
RevETR_RF - Right front ( 5 ) Anormal
reversible emergency
tensioning reactor
5316 Falha na comunicao CAN com a unidade de controlo Armazenado
N80(Módulo da coluna da direco).
5346 CAN message from control module SCM [MRM] is Armazenado
faulty. Steering angle
5350 CAN message from control module N80(Steering Armazenado
column module) is faulty. Steering angle
5318 Fault in CAN communication with control unit Armazenado
N93(Central gateway control unit).
5060 A comunicao CAN tem falha. Armazenado
XALWA_L - Xenon (2) Anormal
headlamp,left
9062 No CAN message was received from control unit SCM Armazenado
[MRM].
9065 No CAN message was received from control unit ABR Armazenado
or ESP.
XALWA_R - Xenon (2) Anormal
headlamp,right
9062 No CAN message was received from control unit SCM Armazenado
[MRM].
9065 No CAN message was received from control unit ABR Armazenado
or ESP.
OCP - Overhead control ( 1 ) Anormal
panel
9701 CAN reception timeout: N93(Central gateway control Armazenado
unit) . Do not replace control module OCP. Continue
troubleshooting in control unit CGW.
SAM_F - Signal (1) Anormal
acquisition and
actuation module front
904D Control module N80(Steering column module) is not Armazenado
sending any data.
REAR SAM - Rear signal ( 2 ) Anormal
acquisition and
actuation module
9107 Component E4e4(Right stop lamp) or the line to the Armazenado
component has a short circuit to positive or open circuit.
90C7 Communication fault with component H3/1(Alarm Actual e
signal siren with additional battery) armazenado
IC - Instrument cluster ( 7 ) Anormal
9101 Control module ESP is not sending any data. Armazenado
9103 Control module Transmission control is not sending Armazenado
any data.
910F Control module CGW is not sending any data. Armazenado
9108 Control module EZS is not sending any data. Armazenado
910B Control module Left front reversible emergency Armazenado
tensioning retractor is not sending any data.
910C Control module Right front reversible emergency Armazenado
tensioning retractor is not sending any data.
910D Control module Intelligent servo module is not Armazenado
sending any data.
SCM - Steering column ( 5 ) Anormal
module
9345 Fault in CAN communication with control unit EIS. Armazenado
9346 Falha na comunicao CAN com a unidade de controlo Armazenado
do grupo de instrumentos.
9354 Falha na comunicao CAN com a unidade de controlo Armazenado
CGW.
9361 Fault in CAN communication with control unit Armazenado
A80(Intelligent servo module for DIRECT SELECT).
9348 Falha na comunicao no bus CAN de dados do motor. Armazenado
PTS - PARKTRONIC (3) Anormal
9025 B8/10(Outer left rear PTS ultrasonic sensor) : Sensor is Armazenado
faulty.
905D [(171/164/251)No or incorrect CAN message from Armazenado
control unit CGW] or [No or incorrect CAN message from
control unit LCP]
905C [(171/164/251)Fault in CAN communication with Armazenado
control unit CGW.] or [No or incorrect CAN message from
control unit Dr-side SAM]
DCM_FR - Door control ( 1 ) Anormal
module front right
900A Component M21/2e1(Right outside mirror ambient Actual e
lamp) or lead has Open circuit. armazenado
Normal ( 14 )
SRS - Supplemental Normal
Inflatable Restraint
System
EIS - Electronic ignition Normal
switch
CGW - Central gateway Normal
UCP - Upper control Normal
panel
HBF(Rear control panel) Normal
- Rear control field
System diagnosis(only Normal
interior CAN fault)
ASSYST Active Service Normal
System
ASSYST PLUS - PLUS Normal
Active Service System
COMAND/AUDIO - Normal
Audio 50(Display and
operating unit with
navigation) or
COMAND(Display and
operating unit)
DCM_FL - Door control Normal
module front left
REDC - REAR_end door Normal
closing control module
ESA driver - Electric seat Normal
adjustment driver(with
memory)
ESA passenger - Electric Normal
seat adjustment front
passenger(with memory)
AC - Air Conditioning Normal