Printed Matter No. 9836 2328 00 Electric nutrunners

Instructions
2005-06
Precio del conjunto de 16000€ (16/06/2016) El Rodamiento.

ETX42-20CT (6-20 Nm) 8435 5120 10


ETX42-20COT (6-20 Nm) 8435 5120 20
ETX42-50CT (10-50 Nm) 8435 5130 10
ETX42-50COT (10-50 Nm) 8435 5130 20
Instructions
Safety Disassembly
The sun gear mounted on the motor shaft may not
The electric motor may only be serviced by be held across the toothed section when removing
properly trained personnel. the bearing. This will bend the teeth. The bearing
is held by an interference fit to the housing
The motor might get hot under extreme conditions.
Touching it might cause skin burn
The torque tranducer might get permanently Assembly
How to place the bearings is indicated by the
damaged if high bending or torsional stresses are
applied across it. See page 2(2). drawing in the pertaining parts list.
Instructions given in this service bulletin must be When having assembled the nutrunner it shall be
possible to rotate the shaft with a wrench
followed. This also applies to any local rules etc.
Connectors
Regarding the replacement of the connectors and
the crimp tool used for this
The use of other than genuine Atlas Copco
replacement parts may result in decreased tool
performance and increased maintenance and may, Useful information
at the company option, invalidate all warranties. You want to service your tools regularly and you
need spare parts fast to avoid downtime. Our
Tools world-wide service and support network is
1. A shortened hex wrench key is required for available to meet your needs.
hexagonal screw. It is made by grinding the
short end of a standard 4 mm hex wrench key ServAid streamlines your work to identify the parts
to a length of 10 mm. See page 2(2). needed.
2. A special tool (drawing 4230 2046 00) is also
required when positioning the connector. See Detailed spare parts information can be found in
page 2(2). AC Connect, which is our web trade site. Beside
3. A special tool (drawing 4230 2044 80) is also spare parts information it is possible to see price
recuired when opening the connector. See and availability and place orders. Please contact
page 2(2). your nearest Atlas Copco Customer Center
representative to get access with an user id and a
Lubricants password.
All gears and rotating parts shall be greased with
LUBRA K HS - Our part No. 4230 1480 00. ServAid is also available in www.acvillage.org/acta
In the US, the same lubricant is known as Courier. and as CD-ROM. Please contact your Atlas Copco
(Data sheet and other details are obtainable from representative for further information.
. Atlas Copco Tools AB, Assembly Systems
Sweden).
Under normal conditions, with motor temperatures
below 80C a service life of 4 years or 2 million
cycles is expected. If a different lubricant is being
used a service interval of less than 2 years, or 1
million cycles is more likely.

Tightening Torque Values


• The three screws M5 holding the gear rim to
the transducer shall be tightened to 10 Nm
• The three screws M6 holding the nutrunner to
the base plate shall be tightened to 15 Nm
• The single screw M4 holding the front part to
the transducer shall be tightened to 5 Nm