MULTIMETER MULTIMETER

EPM-06 / 06C / 06CS EPM-06 / 06C / 06CS


INDEX
Dimensions Precautions for Installation and Safe Usage.........................................................................1
Front Panel and Usage of Buttons.............................................................................1 3 13 12 5 15 14 7 17 16 1
79.3mm 10.8 30.1 7.6 9.5 General Information and Applications.............................................................................1
Using the Buttons............................................................................................2
70mm Transformer Menu (Ctr / trn / Utr / ConnECtýon) ........................................................................2
User Password Settings (Pin Menu).......................................................................2
4
60.6
Activating the User Password (Pin Act Menu)......................................................2 2 6
Changing the User Password (Pin CHg Menu).........................................................2
96mm

Output Setting Menu ..............................................................................3


Current Setting Menu (SP Current Menu) ................................................................3 10 26
High/Low Current Settings (SP Cur Hý, SP Cur Lo Menu)..........................................3
90mm

45.0
11

90.0
Hysteresis Settings for High/Low Currents (CUr Hý Hys, CUr Lo Hys Menu).................3
Delay-on Time for High/Low Currents (Hý on dEL, Lo on dEL Menu)..............................3 23
Delay-off Time for High/Low Currents (Hý oFF dEL, Lo oFF dEL Menu).......................................3 30
Start and Auto Function (StArt dEL and Auto rSt Menu).........................................4
96mm Instant Trip Function (CUr ýnS trP Menu).................................................................4 29 20

14.0

8.5
Voltage Setpoint Menu (SP Volt Menu) ..................................................................4 28 27 19 18 24 25
106.0 High/Low Voltage Settings (SP UoL Hý, SP UoL Lo Menu)..................................4 21
Type PR 19 (96x96) Hysteresis Settings for High/Low Voltages (UoL Hý Hys, UoL Lo Hys Menu)............5
26.5 21.5
10.0
Delay-on Time for High/Low Voltages (Hý on dEL, Lo on dEL Menu).............5
32 31 8 9 22
53.0 Type PK 26 Delay-off Time for High/Low Voltages (Hý oFF dEL, Lo oFF dEL Menu)................5
1 ....... Phase LEDs:The LEDs turn on when the voltage value, which is applied
58.0 Frequency Menu .........................................................................................................6
High/Low Frequency Settings (Frq Hý, Frq Lo Menu).............................................6 to one of the current inputs, reach 30 V
Panel Cut-out Hysteresis Settings for High/Low Frequencies (Frq Hý HyS, Frq Lo HyS) ..............................6 2 ....... First display’s k LED (for L1). Measurement parameter is the unit of kilo
Summary of the Contact Operations Delay-on / Delay-off Time for High/Low Frequencies (Frq on dEL, Frq oFF dEL)....6
79.3mm Phase Sequence (Voltage Sequence Menu) and Instant Trip (UoL ýnS trP Menu) Menu ........6
when LED is turned on. ie: kA, kV
Wall
70mm ALTERNATIVE 1 (U-I) ALTERNATIVE 2 (H-L) Erasing the Max., Min. and Max. Demand Values (Reset Menu)........................6 3 ....... Display for L1.
Demand Time for Demand and Max. Demand (dE tý Menu)....................................................7 4 ....... Second display’s k LED (for L2 and neutral current). Measurement parameter
Communucation Menu (RS-485) .........................................................................7
is the unit of kilo when LED is turned on. ie: kA, kV
Current --> Under/Over Voltage --> Under Technical Features and Default Factory Settings ................................................................7
Connection Diagram ................................................................................................8 5 ....... Display for L2 and neutral current.
Frequency --> Under Output, SP Current and SP Volt menus are available for EPM-06C/06CS; RS-485 menu 6 ....... Third display’s k LED (for L3). Measurement parameter is the unit of kilo
90mm

Out 1
91mm

is available for EPM-06CS.


Current --> Under when LED is turned on. ie: kA, kV
7 ....... Display for L3.
Phase Seq.
PRECAUTIONS FOR INSTALLATION AND SAFE USE 8 ....... Displays network frequency when Hz LED is turned on.
In CT-25 (120A) compliant models, only CT-25 current transformer 9 ....... Display for frequency and Cosj (forEPM-06C/06CS).
91mm Tip 19 must be used. 10 ....... First warning output LED (Out1). Turned on when the output is activated.
Voltage --> Under/Over Voltage --> Over Other type of CT’s have a high risk to damage to device.
Type PR 19 (96x96) 11 ....... Second warning output LED (Out2). Turned on when the output is activated.
50mm Out 2 Frequency --> Under/Over Frequency --> Over Failure to follow those instructions will result in death or serious injury.
12 ....... Over current / voltage warning output for L1. (EPM-06C/06CS)
- Disconnect all power before working on equipment.
Connection Diagram Phase Seq. Current --> Over - When the device is connected to the network, do not remove the front
13 ....... Low current / voltage warning output for L1. (EPM-06C/06CS)
panel. 14 ....... Over current / voltage warning output for L2. (EPM-06C/06CS)
- Do not try to clean the device with solvent or the like.Only clean with dry 15 ....... Low current / voltage warning output for L2. (EPM-06C/06CS)
Valid for EPM-06C/06CS
Choose according to

cloth. 16 ....... Over current / voltage warning output for L3. (EPM-06C/06CS)
contactor current

GND A B TR Out 2 Out 1


- Verify correct terminal connections when wiring. 17 ....... Low current / voltage warning output for L3. (EPM-06C/06CS)
RS485 Relay utput - Electrical equipment should be serviced only by your component seller. 18 ....... Over current / frequency warning output for frequency (EPM-06C/06CS).
- Only for rack panel mounting. 19 ....... Low current / frequency warning output for frequency (EPM-06C/06CS).
Auxiliary Voltage Measurement Current Measurement - Fuse must be F type and limit value doesn’t exceed 1A.
Supply 20 ....... H LED for max. instant current and voltage. Max. instant currents and
Inputs Inputs No responsibility is assured by the manufacturer or any of its subsidiaries
Un voltages are displayed when this LED is turned on.
~ L1 L2 L3 N IL1 IL2 IL3 for any consequences arising out of the use of this material.
21 ....... L LED for min. instant current and voltage. Min. instant currents and
voltages are displayed when this LED is turned on.
1A

PK-26 22 ....... M LED for max. demand. Max. demand values are displayed when this
k l LED is turned on.
L1
K L
k l 23 ....... SET button. It is used to enter into the menu and to save the values.
L2 1 10 11 If SET button is pressed for 3 sec. in the measurement mode, you can
L3
K L
k l System
K L enter into menus. This button is used for monitoring the max. (H), Min.
N (L) current values and max. demand values in measurement mode.
3 24 ....... Downward selection button. And also switching between the phases for
12
K L
L1 2 EPM-06C/06CS.
k l K L 13 25 ....... Upward selection button. And also switching between the phases for
L2 5
System k l K L 14
EPM-06C/06CS.
L3 4 26 ....... ESC button. Displaying the neutral current during the measurement mode.
k l
N 15 Escaping from the menu. And also used for switching off the Latch function
7
1 2 3 4 5 6 16 while this function has activated.
IL1 IL2 IL3 6 27 ....... Over voltage warning LED which is displayed in fourth display.
Current Measurement Inputs 17
28 ....... Low voltage warning LED which is displayed in fourth display.
Choose according to

29
27 29 ....... These LEDs are used for which phase refers to measurement of voltage
contactor current

RS485 PR-19 26
in 4th display.
13 14 15 16 17 18 19 20 28
25 30 ....... Display for monitoring the phase voltages (According to related phase).
Out 1 Out 2 GND B A TR
Output Relay 18 24 31 ....... This LED; indicates Cosj when L1, L2 or L3 activated for monitoring
Auxiliary
Voltage Measurement Inputs Supply 19 voltage values in 4th display.
23 Indicates average value of inductive Cosj when L1-L2 are activated.
7 8 9 10 11 12
20 Indicates average value of capacitive Cosj when L2-L3 are activated.
1A

L1 32 ....... k LED for monitored phase in 4th display.


L2 30 9 8 31 32 21
L3 22 General information
N EPM-06/06C/06CS is designed for measuring the below parameters in a 3-Phase
* Available only for EPM-06C/06CS system. Phase current, frequency, neutral current and voltages (Phase-Phase and
** Available only for EPM-06CS
Phase-Neutral).
Note: For CT-25 models: EPM-06C/06CS;
k: When CT-25 is used, Red cable is connected to k terminal. Device has 2 warning output which named as Out1 and Out2. (NO-Normally Open)
l: When CT-25 is used, Black cable is connected to l terminal.
Please refer to “Output” menu for the functions of the relays.
8 1
A3794 / Rev.6
MULTIMETER MULTIMETER
EPM-06 / 06C / 06CS EPM-06 / 06C / 06CS
Press ESC button one by
Below measurement and application can be implemented with Voltage Transformer Ratio: ESC one until “SAU E SEt EPM-06CS COMPUTER CONNECTION
EPM-06/06C/06CS. In this menu, voltage transformer ratio is set between 0000,1 - 4000,0. yES” is displayed. 31 DEVICES CAN BE CONNECTED AT THE SAME LINE
1) Phase currents (IL), Neutral current (IN), frequency and Cosj
(EPM-06C/06CS); Phase-Phase and Phase-Neutral voltages can be measured. Note: If the voltage transformer is not used between the system and Press SET button. When MAX. 1200 mt.
2) Existence of live phases can be observed by L1-L2-L3 LEDs on the device. EPM-06, voltage transformer ratio is entered as ‘1’. SET “SAU E SEt yES” is RS485/RS232
displayed (If you press CONVERTER
3) Min. and max. values for measured currents and voltages can be monitored Example: If a voltage transformer which has a ratio of 34.5KV/100V
with only one button. ESC button or choose
is used between the system and device; Voltage transformer ratio “no” option instead of “yES” then new data will be cancelled and B
4) Max. demand values for measured current can be monitored, demand is entered as 345. (34500/100)
time can be defined in “dE tý” menu. previous value will be activated). A PC
5) A 4 digit password can be defined from pin menu in order to prevent the Selecting the Connection Type : Serial Communication (for EPM-06CS) GND
change of settings by unauthorized person. EPM-06CS have MODBUS RTU communication protocol which is
6) Current transformer ratio is programmable. (1 .... 2000) Connection can be selected as Star or Delta in this menu. optical isolated. All measured parameters can be transfer to the
Current transformer ratio can be programmed in term of “turn number” computer.Transformer ratios and communication parameters can be

...
TR B A GND TR B A GND TR B A GND
between 1.....20 (for CT-25 adapted devices). set. Saved values can be reset.
Voltage transformer ratio is programmable. (0.1 .... 4000) Phase-Neutral voltage monitoring can be implemented if the “Star” Programmed parameter for communication explained below.
7) A user defined measurement range is used for monitoring the voltages connection is selected. Press SET button 3 sec.
SET
and currents; and Out1 & Out2 outputs are used for warning the user and (trA Fo menu is displayed.)
disconnecting the device in case of exceeding the limits of measurement Phase-Phase voltage monitoring can be implemented if the “Delta” EPM-06CS-31 EPM-06CS-2 EPM-06CS-1
range.
8) In case of using the device for measuring the current values of motors etc., connection is selected. Find RS-485 menu by
start delay (AUto rSt) function can be used for preventing the equipment scrolling UP/DOWN M A X . 2 4 7 D E V I C E S C A N B E C O N N E C T E D AT S A M E L I N E B Y U S I N G R E P E AT E R .
against the improper tripping, which is because of the demurrage current. NOTE: When the “Delta” connection is selected, “neutral current buttons.
9) When a failure has occured use the Latch function, in order to keep the monitoring” can not be implemented even if it is activated and MAX. 1200 mt. MAX. 1200 mt. RS485/RS232
device with saving its position (Latched), even if the failure conditions are displaying function of ESC button will be disabled also. SET
Press SET button (Adr ESS menu is CONVERTER
removed. displayed.)
7th, 8th and 9th subjects are valid for EPM-06C/06CS. User Password Setup: B
In this menu user password is defined and activated. A PC
Using the Buttons: You must define and activate a 4 digit user password for preventing device Find “Adr ESS / bAU d / PArýty” menu GND
Some buttons and button groups are used for the below special function settings from the illegal usage. by scrolling UP-DOWN buttons.
when device is in the measurement mode (Without selecting a menu). There are 2 sub menu in the Pýn menu.

... ...
TR B A GND
Switching between the phase-phase voltages in fourth display. Press SET button (”001 / 9600 /no” menu
Activating the user password : SET
is displayed.)
Used for changing the menu settings and parameters in programming
mode. This menu is used for activating the user password.
After the user password is activated for entering to the menus;
if the SET button is pressed for 3 sec., while the instant values Enter the parameter values by scrolling UP/DOWN buttons EPM-06CS -247 REPEATER EPM-06CS-31 EPM-06CS-2 EPM-06CS-1

SET : Used for monitoring min. / max. currents and voltages or max. demand are observed, user password is required. If the user password (001...247 / 2400...38400 /no, EUEn, odd).
values. Switching to the programming mode if it pressed for 3 sec. In is entered wrong device does not latch. Technical Features
programming mode; it is used for switching to the menu and saving Note: Factory default value of user password is “0000” Press SET button, “Adr ESS / bAU d / PArýty” is displayed. (Data is Rated Voltage (Un) : Please look at back side of the device.
SET entered but is not activated yet. For activating the new data please Operating frequency (f) : 45-65 Hz
changes for the parameters. follow the below steps) Auxiliary Supply Power Consumption : < 4 VA
: Switching between neutral current and phase current in measurement Measuring Input Power Consumption : < 1 VA
ESC
mode. Switching to the previous menu and escaping the programming ESC Press ESC button one by one until “SAU E SEt yES” is displayed. Measurement range
menu without saving the changes. Current : 0.05-5.5A~
If the Latch function is turned on (EPM-06C/06CS); output will be SET To activate the user password; in measurement mode Press SET button. When “SAU E SEt yES” is displayed (If you press
: 2 - 120 A~ for CT-25
released when current(s) of system is exceed the defined values. Press SET button for 3 sec. (trA Fo menu is displayed) SET ESC button or choose “no” option instead of “yES” then new data will
Voltage : 10-300 V AC (Phase - Neutral)
10-500 V AC (Phase - Phase)
When the system’s current turns back to normal values then output be cancelled and previous value will be activated). Class : 1±1% digit [(10%-100%) x full scale]
doesn’t react. Output can be trigged by the “ESC” button. MODBUS RTU PROTOCOL (Available only for EPM-06CS) Current Transformer Ratio : 1 ... 2000
Commissioning and menu setting Find the “Pýn” menu by scrolling UP/DOWN buttons. Turn number for CT-25 adapted models : 1 .... 20
Standart MODBUS RTU message is shown below.
Voltage Transformer Ratio : 1 ... 4000
(for EPM-06/06C/06CS) ADDRESS FUNCTION DATA Max. Ctr x Vtr : 40.000
Energize the device after implementing the connections respected to the T CRCH CRCL T
SET Press SET button (Pýn ACt IUA tE is displayed.) 8 BIT 8 BIT NX8BIT Communications (for EPM-06CS) : MODBUS RTU (RS 485)
user manual. Optic isolated, programmable
Enter the proper menu settings in order to correct measurements and The T times corresponds to a time in which data must not be exchanged on the
communication bus to allow the connected devices to recognize the end of one Baud Rate (for EPM-06CS) : 2400-38400 bps
applications. Press SET button. Blinking the first digit of displayed value appears. message and the beginning of another. This time must be at least 3.5 characters
SET Address (for EPM-06CS) : 1-247
Current Transformer Ratio Setup: at the selected baud rate. Adress range (1-247 ) is address of the connected Parity (for EPM-06CS) : No, Odd, Even, 8 Data Bits, 2 Stop Bits
In this menu, current transformer ratio is set between 1 - 2000. device. The data field contains data sent to the slave by master or data sent to Output Relays (for EPM-06C/06CS) : 2 NO, 5A 1250 VA
(This menu is not available in the devices which are adapted Enter the blinking digit value by scrolling master by slave.
UP/DOWN buttons. Switch to the other Ambiant Temperature : -5°C; +50°C
with CT-25.) CRC is a error check method by using MODBUS RTU protocol and consists of 2 Display : Red LED display
digits by using SET button, use ESC button bytes.
Note: If the current transformer is not used between the system to go to previous digit. After you entered Dimensions : PR-19, PK-26
and device, current transformer ratio is entered as ‘1’. SET the last digit press SET button, “Pýn ACt
Available Modbus Function: Equipment Protection Class : Double Insulation - Class II ( )
Example: If a current transformer which has a ratio of 30/5A is oF” is displayed.“on” can be selected by 03H READ HOLD REGISTERS Box Protection Class : IP 40
used between the system and device; scrolling UP/DOWN buttons. (Data is 06H PRESET SINGLE REGISTER
Terminal Protection Class : IP 00
entered but is not activated yet. For Box Material : Nonflamable
Current transformer ratio is entered as = 30/5 = 6. 10H PRESET MULTIPLE REGISTERS Mounting : Panel Mounted (PR-19)
SET Press SET button for 3 sec. (trA Fo menu is displayed) activating the new data please follow the Read Hold (03) function is used for reading measured values and set value. If any Rail Mounted (PK-26)
below steps). request of reading of a register, excepted mentioned in register table, device will Wire Crossection (for terminals) : 2.5 mm2
Press SET button; trA Fo Ctr menu is displayed (In CT-25 adapted send an error message. Weight : 0.56 kg (PR-19)
SET devices, trA Fo trn is displayed instead.) Press ESC button one by For example to read phase1 voltage by sending a message to the device. 0.52 kg (PK-26)
(Not: trA Fo Utr or Con nEC týo n menu can be displayed by scrolling ESC one until “SAU E SEt yES” 01 03 00 00 00 02 XX XX Mounting Category : Class III
the UP/DOWN buttons.) is displayed. 01 Device address Panel Size : 91x91 mm (PR-19)
Press SET button. Blinking the first digit of displayed value appears. 03 Function 46x107 mm (PK-26)
SET (”trA Fo Utr” or “Con nEC týo n” menu can be 00 MSB address
Press SET button. When
programmed similarly.) “SAU E SEt yES” is 00 LSB address Default Settings
Enter the blinking digit value by scrolling SET displayed (If you press 00 Register number MSB .../5A type
UP/DOWN buttons. Switch to the other ESC button or choose “no” option instead of “yES” then new data will 02 Register number LSB
digits by using SET button, use ESC button be cancelled and previous value will be activated). XX CRC MSB Ctr - 0001 CUr Hý L-1 - 5.000 CUr Lo L-2 - 0.000 Out relay - U-I
to go to previous digit. After you entered XX CRC LSB Utr - 0001 CUr Hý L-2 - 5.000 CUr Lo L-3 - 0.000 Latch - oFF
SET the last digit press SET button, “trA Fo Ctr” Preset Single Register (06) function is used for writting the setting values, erasing trn - 01 CUr Hý L-3 - 5.000 CUr Lo L-n - 0.000 Out Inverse - oFF
Changing of User Password: the energy counter or resetting the min., max., max. demand values. ConnEC - StAr CUr Hý L-n - 5.000 CUr Lo HyS - 0.200
is displayed. (Data is entered but is not
activated yet. For activating the new data This menu is used for changing the user password. Current transformers ratio can be set 0-2000, voltage transformer ratio can be set CUr Hý HyS - 0.100 Lo on dEL - 010.0 bAUd - 9600
please follow the below steps). Note: Factory default value for user password is “0000” 1-40000. Pin Act - oF Hý on dEL - 010.0 Lo oFF dEL - 010.0 AddrES - 001
i.e. Setting CT as 100; Pin - 0000 Hý oFF dEL - 010.0 Str Art dEL - 0.000 PArty - no
ESC Press ESC button one by one until 01 06 80 02 00 64 XX XX CUr Lo L-1 - 0.000 Auto reset - oFF
“SAU E SEt yES” is displayed. 01 Device address dt - 15 Cur ýns trp - oFF
Press SET button. When “SAU E 06 Function
SEt yES” is displayed (If you 80 MSB address UoL Hý L-1 - 250 UoL Lo L-3 - 180 Frq Hý - 63
press ESC button or choose “no” 02 LSB address UoL Hý L-2 - 250 UoL Lo HyS - 010.0 Frq Hý HyS - 01.00
SET 00 Data MSB UoL Hý L-3 - 250 Lo on dEL - 003.0 Frq Lo - 47
option instead of “yES” then new To change the user password; in measurement mode
SET 64 Data LSB UoL Hý HyS - 10 Lo oFF dEL - 003.0 Frq Lo HyS - 01.00
data will be cancelled and Press SET button for 3 sec. (trA Fo menu is displayed)
previous value will be activated). XX CRC MSB Hý on dEL - 003.0 UoL PHS SEq - oFF Frq on dEL - 003.0
Find the “Pýn” menu XX CRC LSB Hý oFF dEL - 003.0 UoL ýnS trP - oFF Frq oFF dEL - 003.0
Programming the Turn Number: Preset Multiple Register(10H) is used to set more then one register at same time. UoL Lo L-1 - 180
This menu is available for CT-25 adapted devices. User defines the by scrolling i.e. Setting CT as 100, Ut as 20.0; UoL Lo L-2 - 180
turn number, which is the number of how many tour the current UP/DOWN buttons. 01 10 80 00 00 02 04 00 C8 00 64 XX XX
cable has rounded into the CT-25. Numbers can be selected 01 Device Address
Press SET button 10 Function CT-25 type CUr Hý L-1 - 100.0 CUr Lo L-2 - 0.000
between 1-20. Greater the number of turn means greater the CUr Hý L-2 - 100.0 CUr Lo L-3 - 0.000
sensivity. SET (Pýn ACt IUA tE is 80 MSB address
00 LSB address CUr Hý L-3 - 100.0 CUr Lo L-n - 0.000
displayed.) 00 Register number MSB CUr Hý L-n - 100.0 CUr Lo HyS - 2.000
02 Register number LSB CUr Hý HyS - 2.000 Lo on dEL - 010.0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 04 Byte count Hý on dEL - 010.0 Lo oFF dEL - 010.0
Find the “Pýn CHA n9E” menu by scrolling UP/DOWN buttons. Hý oFF dEL - 010.0 Str Art dEL - 0.000
2.00 1.00 0.66 0.50 0.40 0.33 0.28 0.24 0.22 0.20 0.18 0.16 0.15 0.14 0.13 0.12 0.11 0.11 0.10 0.10 00 Data MSB
C8 Data LSB CUr Lo L-1 - 0.000 Auto reset - oFF
120 60.0 40.0 30.0 24.0 20.0 17.1 15.0 13.3 12.0 10.9 10.0 9.23 8.57 8.00 7.50 7.05 6.66 6.31 6.00
00 Data MSB Cur ýns trp - oFF
2 64 Data LSB
7
XX CRC MSB
XX CRC LSB
MULTIMETER MULTIMETER
EPM-06 / 06C / 06CS EPM-06 / 06C / 06CS
Phase sequence can be turned on/off in this menu. In case of using the device for measuring the current values
Inversed phase voltage which is applied to the of motors etc., start delay (AUto rSt) function can be used for
Press SET button. Blinking measurement inputs (L1-L2-L3), can be monitored. Enter the old password by scrolling
SET the first digit of displayed SET preventing the equipment against the improper tripping, which
value appears.
Default setting is off. In order to let the device to warn UP/DOWN/SET buttons. is because of the demurrage current. If the system current
user in case of inversed phase situation please change decreases 50mAxCtr then start-up delay is resetted and related
the off position as on in “UoL PHS SEq” menu. Phase
Enter the value by scrolling
sequence function is disabled if the selection is Enter the new password by scrolling output detect the system automatically. This feature must be
UP/DOWN buttons and observed in case of using this function.
SET confirm it by SET button. Press ESC selected off. SET UP/DOWN/SET buttons.
button for switching the previous menu. L1, L2 and L3 LEDs blink and output output released
immediately when “UoL PHS SEq” is turned on and In this menu, high set points for current values are programmed.
Press SET button, [(Hý on dEL / Hý oFF dEL phase sequence is inverted with any reason. Hý values for IL1, IL2, IL3 and IN can be entered one by one.
/ Lo on dEL / Lo oFF dEL) / (Hý on dEL / Hý
Enter the new password again by If all the current values are under the Hý value; Out1 output is
Note: Output 2 is used if U-I is selected and Output1
oFF dEL / Lo on dEL / Lo oFF dEL)] are SET scrolling UP/DOWN/SET buttons. switched on, LED of Output1 turned on and LED of H turned
SET is used if H-L is selected in Output menu for the
displayed. (Data is entered but is not activated Phase Sequence monitoring. off.
yet. For activating the new data please follow If any current (IL1, IL2, IL3 and IN) exceeds the high set value,
the below steps) Instant Tripping Function. Press SET button, “Pýn CHA n9E” is displayed.
(Data is entered but is not activated yet. For activating the new data H LED blinks. Output 1 output switches off at the end of the
At position ON, if any VL-L / VL-N values exceeds 1.5 SET
please follow the below steps) defined time (Hý on dEL), Output 1 LED turned off and H LED
Press ESC button one by one until “SAU times of high voltages (UoL Hý L-1/L-2/L-3) values; turned on continuously.
ESC
E SEt yES” is displayed. the “voltage output” switches OFF instantly, output If all currents (IL1, IL2, IL3 and IN) are below the high set value
ESC Press ESC button one by one until “SAU E SEt yES” is displayed.
LED turned OFF and H LED, for related voltage, is (Hý) as a hysteresis current (CUr Hý HyS), output 1 output switches
Press SET button. When “SAU E SEt yES” is displayed (If you press turned ON . (Please refer to “Output”.) on at the end of the defined time (Hý oFF dEL), output 1 LED turned
SET ESC button or choose “no” option instead of “yES” then new data will Press SET button. When “SAU E SEt yES” is displayed (If you press on and H LED turned off.
be cancelled and previous value will be activated). ESC button or choose “no” option instead of “yES” then new data will This menu has 7 sub menus.
If any phase voltage decrease 0.5 times low voltages SET
be cancelled and previous value will be activated). CUr Hý L-1, CUr Hý L-2, CUr Hý L-3, CUr Hý L-n, CUr Hý HyS,
Setpoints for Frequency : (UoL L-1/L-2/L-3); the “voltage output” switches OFF
instantly, output LED turned OFF and Lo LED, for Output menu (only for EPM-06C/06CS) : Hý on dEL, Hý oFF dEL
In this menu, Frequency range can be defiend
according to High and Low values of Frequency related voltage, is turned ON . In this menu, using of oUt PUt function is explained with details below. Note: High Current values are programmed for IL1, IL2, IL3
measurement. (Refer to Page-4 for “CUr ýnS trP”, “AUt o rSt” and and IN separately but CUr Hý HyS (hysteresis), Hý on dEL
If the frequency of the system decreases the Frq Hý “UoL ýnS trP”) (delay on time) and Hý oFF dEL (delay off time) values are
value; output is switched on and LED is turned on. common and they have same values for IL1, IL2, IL3 and IN.
(Refer to Output menu) and H LED for frequency is Reset function. Out Relay function: In this menu, low set points for current values are programmed.
turned off. In this menu, values of min., max., max. demand are erased. It In this menu high-low or voltage-current monitoring is Lo values for IL1, IL2, IL3 and IN can be entered one by one.
If the frequency of the system exceeds the high set saves the instantaneously measured min. and max. values of the determined for Out1 and Out2 outputs. If all the current values are over the Lo value; Out1 output is
value, H LED relating to frequency blinks, output device into its memory. Please kindly look at to the section of Note: When U-I (voltage-current) is selected; Out2 is switched on, LED of Output1 turned on and LED of L turned
switched off at the end of defined time (Frq on dEL), functions of buttons for min. and max. values. monitoring according to high or low voltage, frequency off.
LED turned off (Refer to Output menu) and H LED Note: Measured electrical parameters which are saved to the values and phase sequence, Out1 is monitoring according If any current (IL1, IL2, IL3 and IN) exceeds the low set value,
for frequency is turned on continuously. memory are not affected from the electric interruptions. to high or low-current value. L LED blinks and Output 1 output switches off at the end of the
If the frequency of system are under the high set value defined time (Lo on dEL), Output 1 LED turned off and L LED
In the rES Et HL or rES Et dE menu; when you choose yES and When H-L (high-low) is selected; Out2 is monitoring
(Frq Hý) as a hysteresis (Frq Hý HyS), output is turned quit from all menus, if you confirm the changes, min., max. and turned on continuously.
on at the end of defined time (Frq oFF dEL), LED is according to high values for voltage, frequency and low- If all currents (IL1, IL2, IL3 and IN) are over the low set value (Lo)
turned on and H LED is turned off. at the end of the max. demand values of all parameters are erased at the same current, Out1 is monitoring according to low values for as a hysteresis current (CUr Lo HyS), output 1 output switches on
adjusted time (Frq oFF dEL), output1 LED turns on time. voltage or current. at the end of the defined time (Lo oFF dEL), output 1 LED turned
and Hý LEDs turn off. Press SET button for 3 Please refer to page 8 for a summary of the contact on and L LED turned off.
SET sec. (trA Fo menu is This menu has 7 sub menus.
If the frequency of the system is over the low set value operations.
(Frq Lo), output is turned on, LED is turned on L LED displayed.) CUr Lo L-1, CUr Lo L-2, CUr Lo L-3, CUr Lo L-n, CUr Lo HyS,
Out Latch function: Lo on dEL, Lo oFF dEL
is turned off. If the Latch function is turned on;
If the frequency of the system decreases the low set Find rES Et menu by Note: Low Current values are programmed for IL1, IL2, IL3
scrolling UP-DOWN OUT1-OUT2 outputs, which are released when a failure has and IN separately but CUr Lo HyS (hysteresis), Lo on dEL
value (Frq Lo), L LED blinks; output is turned off at buttons.
the end of defined time (Frq ond), LED is turned off occured, keep remained at its position even if the failure is (delay on time) and Lo oFF dEL (delay off time) values are
and L LED is turned on continuously. over. Press ESC button in order to triggering the relay when common and they have same values for IL1, IL2, IL3 and IN.
If the frequency of the system is over the low set value Press SET button the failure situation is removed. In this menu, max. current value for IL1 is programmed.
SET The current value can be programmed between;
(Frq Lo HyS) as a hysteresis (Frq Hys), output is turned (rES Et HL menu is displayed.) If the Latch function is turned off;
on at the end of defined time (Frq oFF dEL), LED is Released outputs triggered at the end of delay off time when 0,001....5,000 A (Ctr = 1);
000,1....120,0 A (for CT-25 adapted device trn=1).
turned on and L LED is turned off. the failure situation is removed. If the value is set to zero (0), the high current warning
Find rES Et dE / rES Et HL menu by Out inverse function:
scrolling UP-DOWN buttons. is disabled (CUr Hý L-2 and CUr Hý L-3 are programmed
Note: System frequency is measured for L1. If “oUt ýnU ErS” function is selected off; similarly). Refer “SP Cur Hý” for details.
Device is started with closed output contacts (out1, out2) in In this menu, min. current value for IL1 is programmed.
Press SET button (”rES Et dE no the normal network conditions according to settings. The current value can be programmed between;
There are 6 submenus. SET / rES Et HL no” is displayed.)
Otherwise devices started with open position of the contacts. 0,001....5,000 A (Ctr = 1);
Frq Hý, Frq Lo, Frq Hý HyS, Frq Lo HyS, Frq on dEL, 000,1....120,0 A (for CT-25 adapted device trn=1).
Frq oFF dEL. Default setting is “off”. If the value is set to zero (0), the low current warning
By using the UP-DOWN buttons, other is disabled ( CUr Lo L-2 and CUr Lo L-3 are
Max. value for system frequency, this value parameters can be selected. If you want to delete the value, choose yES, programmed similarly). Refer “SP Cur Lo” for details.
can be defined between 0...70.00 Hz. if not choose no.
If the value is set to zero (0), the high In this menu, required hysteresis current for high
frequency warning is disabled. current warning is programmed. (same for IL1, IL2,
Press SET button, rES Et dE / rES Et HL is displayed. (Data is entered IL3 and IN.)
SET but is not activated yet. Activating the new data, please Press SET button for 3 secs. (trA Fo menu is displayed).
SET The current value can be programmed between;
Min. value for system frequency, this value follow the below steps) 0,001....2,500 A (Ctr = 1)
can be defined between 0...70.00 Hz. 000,1....60,00 A (for CT-25 adapted device trn=1)
If the value is set to zero (0), the low ESC Press ESC button one by one until “SAU E SEt yES” is displayed. Refer “SP Cur Hý” for details.
frequency warning is disabled. Find oUt PUt menu by scrolling UP-DOWN buttons. In this menu, required hysteresis current for low current
Note: Attention for common using of output Press SET button. When “SAU E SEt yES” is displayed (If you press warning is programmed. (same for IL1, IL2, IL3 and
SET ESC button or choose “no” option instead of “yES” then new data will IN.)
and relay LED for voltage. be cancelled and previous value will be activated). Press SET button oUt rEL AY / oUt LAt CH / oUT ýnU ErS The current value can be programmed between;
SET
In this menu, required hysteresis value can are displayed. 0,001....2,500 A (Ctr = 1)
be defined between 0...20.00 Hz. in order 000,1....60,00 A (for CT-25 adapted device trn=1)
to switching off the “high frequency” Press SET button, U-I blinks in 4th display. (oFF blinks for oUt LAt CH Refer “SP Cur Lo” for details.
Demand Time. SET
warning. and oUT ýnU ErS) Delay time for activating the output for high current
Max. Demand time can be defined between 01-60 minute in this warning. It is common for all currents (IL1, IL2, IL3
menu. and IN)
Select U-I or H-L by scrolling UP/DOWN buttons. (Select on or oFF for The value can be programmed between 000,0 and
In this menu, required hysteresis value can “oUt LAt CH” and “oUT ýnU ErS”) 999,9 in terms of seconds.
be defined between 0...20.00 Hz. in order (Refer “SP Cur Hý” for details.)
to switching off the “low frequency” warning. Press SET button for 3 sec. Press SET button, oUt rEL AY is displayed. (Data is entered but is not Delay time for activating the output for low current
SET (trA Fo menu is displayed.)
SET activated yet. Activating warning. It is common for all currents (IL1, IL2, IL3
the new data, please and IN)
follow the below steps) The value can be programmed between 000,0 and
Find dE tý menu by scrolling UP-DOWN 999,9 in terms of seconds.
Delay-on time for activation of alarm for high Press ESC button one by (Refer “SP Cur Lo” for details.)
buttons.
and low frequency value. ESC one until “SAU E SEt Delay time for releasing the output for high current
This value can be defined between yES” is displayed. warning. It is common for all currents (IL1, IL2, IL3
000.0..999.9 in term of second.. Press SET button. Blinking the first digit of and IN)
SET
displayed value appears. Press SET button. When “SAU E SEt yES” is displayed (If you press The value can be programmed between 000,0 and
SET ESC button or choose “no” option instead of “yES” then new data will be 999,9 in terms of seconds.
cancelled and previous value will be activated). (Refer “SP Cur Hý” for details.)
Delay-off time for disactivation of alarm for Enter the blinking digit value by scrolling UP/DOWN buttons. Switch Delay time for releasing the output for low current
high and low frequency value. to the other digits by using SET button, use ESC button to go to Programming “SP CUr rnt” : warning. It is common for all currents (IL1, IL2, IL3
SET
This value can be defined between previous digit. After you entered the last digit press SET button, “dE Using purposes of submenus of “SP CUr rnt” explained below and IN)
tý” is displayed. (Data is entered but is not activated yet. For activating with details. The value can be programmed between 000,0 and
000.0..999.9 in term of second.. the new data please follow the below steps). 999,9 in terms of seconds.
(Refer “SP Cur Lo” for details.)
6 3 (Refer to Page-5)
MULTIMETER MULTIMETER
EPM-06 / 06C / 06CS EPM-06 / 06C / 06CS
Programming the “SP CUr Hý”, “SP CUr Lo”, “SP UoL Hý” and “SP UoL Lo”. Programming “CUr ýnS trP”, “AUt o rSt” and “UoL ýnS trP” In this menu, low set points for voltage values are Programming the “U-H HyS”, “U-L HyS”, “I-H HyS”, “I-L HyS”
Press SET button for 3 sec. programmed. Lo values for Phase-Neutral / Phase-
SET
(trA Fo menu is displayed.) Phase (according to Star / Delta selection) can be
SET Press SET button for 3 sec.
entered one by one. (trA Fo menu is displayed.)
Find “SP CUr rnt / SP UoL t” Press SET button for 3 sec.
menu by scrolling
SET
(trA Fo menu is displayed) If all the voltage values (Phase-Neutral / Phase-Phase)
UP-DOWN buttons. are over the Lo value; releated output is switched on, Find “SP UoL t / SP CUr”
its LED turned on (please refer “Output”) and releated menu by scrolling
UP-DOWN buttons.
Find “SP CUr rnt / SP UoL t” L LEDs are turned off.
SET Press SET button, “SP CUr Hý / SP UoL Hý” menu by scrolling UP-DOWN buttons. If any of the voltage valueses (Phase-Neutral / Phase-
menu is displayed.
Phase) decrease the Lo value, L LED blinks and SET Press SET button (SP UoL Hý / SP CUr Hý
releated output is switched off at the end of “delay menu is displayed.)
Find [(SP CUr Hý/SP CUr Lo) / (SP UoL Press SET button (SP CUr Hý / SP Uol Hý
Hý/SP UoL Lo)] menu by scrolling UP- SET on time” (Lo on dEL), its LED turned off (please refer
menu is displayed.)
DOWN buttons. “Output”) and releated L LED is turned on continuously. Find [(SP UoL Hý / SP UoL Lo) / (SP CUr Hý
/ SP CUr Lo)] menu by scrolling
If all voltage (Phase-Neutral / Phase-Phase) values UP-DOWN buttons
Press SET button [(CUr Hý L-1/CUr Lo L-1) Find [(CUr ýnS trP / AUt o rSt) / UoL ýnS trP]
SET menu by scrolling UP-DOWN buttons. increase the low set value (Lo) as a hysteresis voltage
/ (UoL Hý L-1/UoL Lo L-1) menu is displayed.]
(UoL Lo HyS), releated relay is switched on at the end Press SET button [(Uo L H ý L-1/UoL Lo L-1)
of the “delay off time” (Lo oFF dEL), its LED turned on SET / (CUr Hý L-1/CUr Lo L-1) menu is displayed.]
Press SET button. Blinking the first digit of
SET displayed value appears. Press SET button [(CUr ýnS trP on / (please refer “Output”) and L LED is turned off.
SET AUt o rSt on) / UoL ýnS trP off] is displayed. Note: Low Voltage values are programmed for (Phase-
Neutral / Phase-Phase) separately but “UoL Lo HyS” Find [(UoL Hý HyS / UoL Lo HyS) / (CUr Hý HyS / CUr Lo HyS)] menu
Enter the blinking digit by scrolling UP-DOWN buttons.
value by scrolling (hysteresis), “Lo on dEL” (delay on time) and “Lo oFF
UP/DOWN buttons. Select “on” in order to activating the “instant trip function” (AUt o rSt), dEL” (delay off time) values are common; these
select “off” in order to disactivating the “instant trip function”, by scrolling
SET Switch to the other digits UP/DOWN buttons.
parameters have same values for Phase-Neutral /
Press SET button. Blinking the first digit of
by using SET button, use Phase-Phase. SET
ESC button to go to previous digit. After you entered the last digit displayed value appears.
press SET button, “CUr Hý L-1/CUr Lo L-1) / (UoL Hý L-1/UoL Lo L-1”
When Connection type (Star/Delta) is selected (refer
Press SET button, [(CUr ýnS trP / AUt o rSt) / UoL ýnS trP] is displayed. to Connection menu), device will change the Enter the blinking digit value by
is displayed. (Data is entered but is not activated yet. For activating SET (Selection is entered but is not activated yet. For activating the new
the new data please follow the below steps). UoL Lo L-1, L-2 and L-3 values automatically according scrolling UP/DOWN buttons.
selection, please follow the below steps). Switch to the other digits by using
to connection.
Press ESC button one by one until “SAU E SEt yES” is displayed. SET button, use ESC button to go to
ESC Press ESC button one by one until “SAU E SEt yES” is displayed. Example : If the connetion type is selected as Star
ESC SET previous digit. After you entered the last
(with neutral); UoL Lo Hys=10V digit press SET button,
Press SET button. When “SAU E SEt yES” is displayed (If you press UoL Lo L-1=180V, UoL Lo L-2=175V, UoL Lo L-3=170V [(UoL Hý HyS / UoL Lo HyS) / (CUr Hý HyS / CUr Lo HyS)] is displayed.
SET ESC button or choose “no” option instead of “yES” then new data will Press SET button. When “SAU E SEt yES” is displayed (If you press (Data is entered but is not activated yet. For activating the new data
SET ESC button or choose “no” option instead of “yES” then new data will and then this connection type is selected as Delta
be cancelled and previous value will be activated). please follow the below steps).
be cancelled and previous value will be activated). (without neutral), device will change the values after
Start-up delay: Programming “SP UoL t” : calculated them according to Phase-Phase values.
Start Delay Time is used to prevent from faulty Press ESC button one by
Using purposes of submenus of “SP UoL t” explained below with New values; ESC one until “SAU E SEt yES”
switchings caused by motor start-up current UoL Lo L-1 (L1-L2 Phase to phase voltage) = 311 V
(demurrage current). details. is displayed.
Out1 remain switched ON in this time period (When UoL Lo L-2 (L2-L3 Phase to phase voltage) = 303 V
UoL Lo L-3 (L3-L1 Phase to phase voltage) = 294 V Press SET button. When
U-I is selected); In this time period, even if the current “SAU E SEt yES” is
value exceeds the limits device doesn’t sense it as a UoL Lo HyS = 10 V. SET
displayed (If you press ESC button or choose “no” option instead of “yES”
warning. The device doesn’t give a warning even if the There are 6 submenus. then new data will be cancelled and previous value will be activated).
current value isn’t in the setting interval. U oL Lo L - 1 , U o L L o L - 2 , U o L L o L - 3 , U o L “Delay on” time for activating the output for
This function is used with “Auto Reset” function. In this menu, high set points for voltage values are Lo HyS,Lo on dEL, Lo oFF dEL. high voltage warning. It is common for all
Auto Reset Function : programmed. Hý values for Phase-Neutral / Phase- High value for L1, when the Star is voltages (same for Phase-Neutral/Phase-
If Auto Reset function is selected as ON; Phase (according to Star / Delta selection) can be selected; high value for L1-L2, when the Phase.)
Each time that the current decreases “50mAxCtr” value, entered one by one. The value can be programmed between
Delta selected can be defined in this 000,0 and 999,9 in terms of seconds.
start-up delay time is reset and when the current value menu.
increases “50mAxCtr”, start-up delay function is (Refer “SP UoL Hý” for details.)
If all the voltage values (Phase-Neutral / Phase-Phase) 0....300 for Star connection and “Delay on” time for activating the output for
activated. 0....500 for Delta connection can be
If Auto Reset function is selected as OFF; are under the Hý value; releated relay is switched on, low voltage warning. It is common for all
If the power supply is switched off and then switched its LED turned on (please refer “Output”) and releated defined. voltages (same for Phase-Neutral/Phase-
on, start-up delay function is activated. H LEDs are turned off. If the value is set to zero (0), the high Phase.)
If all the voltage values (Phase-Neutral / Phase-Phase) voltage warning is disabled. Refer “SP The value can be programmed between
Please refer to below graphics for the operating Uol Hý” for details. 000,0 and 999,9 in terms of seconds.
are over the Hý value, H LED blinks and releated output
principle of StA rt dEL and Aut o rSt functions (Refer “SP UoL Lo” for details.)
is switched off at the end of “delay on time” Note: L2 and L3 phases can be “Delay off” time for activating the output for
Un (on) (Hý on dEL), its LED turned off (please refer “Output”) programmed similarly. high voltage warning. It is common for all
Un (off) t(s) and releated H LEDs are turned on. voltages (same for Phase-Neutral/Phase-
Hý on dEL = 10 sec.
Low value for L1, when the Star is Phase.)
Lo on dEL = 10 sec. If all voltage (Phase-Neutral / Phase-Phase) are below selected; low value for L1-L2, when the The value can be programmed between
5A Hý oFF dEL = 5 sec. the high set value (Hi) as a hysteresis voltage (UoL Hý Delta selected can be defined in this 000,0 and 999,9 in terms of seconds.
4A Lo oFF dEL = 5 sec. HyS), releated output is switched on at the end of the menu. (Refer “SP UoL Hý” for details.)
Start = 15 sec. “delay off time” (Hý oFF dEL), its LED turned on (please 0....300 for Star connection and “Delay off” time for activating the output for
3A
CUr Hý L1 = 3A refer “Output”) and H LED is turned off. 0....500 for Delta connection can be low voltage warning. It is common for all
2A defined.
CUr Lo L1 = 1A Note: High Voltage values are programmed for voltages (same for Phase-Neutral/Phase-
1A Ins. trp = on If the value is set to zero (0), the high Phase.)
(Phase-Neutral / Phase-Phase) separately but “UoL
I L1 t(s)
Hý HyS” (hysteresis) and “Hý on dEL” (delay on time) voltage warning is disabled. Refer “SP The value can be programmed between
Hý on Hý on Hý oFF
and “Hý oFF dEL” (delay off time) values are common; Uol Lo” for details. 000,0 and 999,9 in terms of seconds.
Start Start
dEL
Start
dEL dEL
(Refer “SP UoL Lo” for details.)
Switch-on these parameters have same values for Phase-Neutral Note: L2 and L3 phases can be
Out1 “Hý on dEL”, “Hý oFF dEL”, “Lo on dEL”, “Lo oFF dEL” settings are
Switch-off Lo on Lo oFF t(s) / Phase-Phase. programmed similarly. explained for SP UoL t and SP CUr rnt
dEL dEL
Auto Start
When Connection type (Star/Delta) is selected (refer
on Switch-on
Out2 to Connection menu), device will change the Press SET button for 3 sec.
(Refer to Page-4 for SP CUr Hý, SP CUr Lo, SET
Switch-off t(s)
UoL Hý L-1, L-2 and L-3 values automatically according (trA Fo menu is displayed.)
Hý on Hý on Hý oFF Hý on Hý oFF to connection. SP UoL Hý ve SP UoL Lo)
dEL dEL dEL dEL dEL
Start
Switch-on In this menu, required hysteresis voltage Find “SP UoL t / SP CUr”
Out1 Example : If the connection type is selected as Star menu by scrolling
Switch-off for high voltage warning is programmed.
Auto
Start Ins.
Lo oFF
dEL
Lo on Lo oFF
dEL Ins.
Lo oFF
dEL
t(s)
(with neutral); UoL Hý HyS=10V UoL Hý L-1=250V, (same for Phase-Neutral/Phase-Phase.) UP-DOWN buttons.
of trp.
dEL
trp.
Switch-on UoL Hý L-2=255V, UoL Hý L-3=260V 0....200V for Star connection and
Out2
Switch-off t(s) and then this connection type is selected as Delta 0....200V for Delta connection can SET Press SET button (SP UoL Hý / SP CUr Hý
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200
(without neutral), device will change the values after be defined. menu is displayed.)
calculated them according to Phase-Phase values. Refer “SP UoL Hý” for details.
Instant Tripping Function.
New values; Find [(SP UoL Hý / SP UoL Lo) / (SP CUr Hý
At position ON, if any phase current (IL1, IL2, IL3 and
UoL Hý L-1 (L1-L2 Phase to phase voltage) = 433 V In this menu, required hysteresis voltage / SP CUr Lo)] menu by scrolling
IN) exceeds 1.5 times of high (CUr Hý L-1, L-2, L-3, for low voltage warning is programmed. UP-DOWN buttons.
L-n) values, the “current output” switches off instantly, UoL Hý L-2 (L2-L3 Phase to phase voltage) = 441 V
(same for Phase-Neutral/Phase-Phase.)
output LED turned off and H LEDs for related currents UoL Hý L-3 (L3-L1 Phase to phase voltage) = 450 V 0....200V for Star connection and Press SET button [(UoL Hý L-1 / UoL Lo L-1)
SET
turned on. (Please refer to “Output”.) UoL Hý HyS = 10 V. 0....200V for Delta connection can /(CUr Hý L-1 / CUr Lo L-1) menu is displayed.]
At position OFF, if any phase current (IL1, IL2, IL3 and There are 6 submenus. be defined.
IN) decrease 0.5 times of low (CUr Lo L-1, L-2, L-3, U oL Hý L - 1 , U o L H ý L - 2 , U o L H ý L - 3 , U o L H ý Refer “SP UoL Lo” for details.
L-n) values, the “current output” switches off instantly, Find [(Hý on dEL / Hý oFF dEL / Lo on dEL / Lo oFF dEL) / (Hý on dEL /
HyS, Hý on dEL, Hý oFF dEL. Hý oFF dEL / Lo on dEL / Lo oFF dEL)] menu by scrolling UP-DOWN
output LED turned off and L LEDs for related currents buttons.
turned on. (Please refer to “Output”.)
At position OFF, instant tripping function is cancelled. 4 5

You might also like