‘Repor Name: GPCer_ 2006 Mol aee ne oa ikea Calibration me Certificate of Calibration Laboratory, a REND oe Certiia Certificate Number: 20210429-73444 Pees Manufacturer: 1ET Labs, Inc. ‘Submitted By: Tan Delta Electric Corporation Model: VRS-100-10-10K-BP-10KV. Tandelco Bidg., 34A J.P. Rizal St. Description; High Resistance Standard Project 4 ‘Serial Number: E3-1914504 Quezon City 1109, Phillipines Customer Designat thee Condition Received New unit Ci Met manufacturer's specifications Y Out of tolerance Ci tnoperative ~ © Physical Damage (see Details of Damage) Condition Returned ©: Calibrated/Certified to manufacturer's specifications © Repaired Other (see Condition Returned Notes) Repair Details “ustoner Report: Unit has high leakage at 10 kV over 16. Findings: Unit found in specs for all values except to 10 10. ‘ormed: Replaced 10T resistor. unit was tested at 1 kV, 5 kV and Unit was fully inspected and calibrated. MegBridge SkV-TP Rev, The, instrunont listed above vas calibrated by 187 Labs, accoraing to a Al °1ibration Procedure MegBridge 5 KV-TP, Rev Al. NogBridge is a measurenent system for measuring 2 terminal resistors at woltages up to 6 kVdc. It utilizes the Tl? Labs 1865 Plas meatthortes to measure current, a Fluke 8845A and KWS voltage divider to mesore veitrco, ~ and a high voltage source. The resistance of the DUI ia thes sereuveeea” VRS-TP Rev, A3 The instrunent Listed above vas calibrated by IEM Labs, according co Calibration Procedure VRS-TP, Rov AS, Test Time Calibration for For resistances s 10 6 neasurenent. tine ie < 20 seconds. Decade Resistance TO! resists Q measurenent tine is approximately 60 seconds. Associated Test Reports Report # Date Test Description : 128389 29-ape-2021 Aa Returned 129406 29-Apr-2021 As Returned ~ 5000 v 128369. 28-Apr-2021 As Received 120378 28-spr-2021 As Received = 5000 v Standards And Tools Used Manufacturer Model Description Serial Number Cal Date Due Date Ohm-Labs Tne 11 Standard Resistor, 100 Ga n012 19-0ct-2020 19-oct-202 Ohn-Labs inc nz Standard Resistor, 1 1a 013 30-0ct-2020 30-oct-2021 TET Labs, In 1865+ Negohmeter / 8 Tester B9-19172827 13-May-2020 13-May-2021 Keith. 6517-2 igh Resistance Meter 4340142 09-Nov-2020 09-Nov-2021 Page 1 of 6 Certificate or report shall not be reproduced except in full without approval of IET Labs, inc. IET LABS, INC. ‘Standards © Decades « Strobes ¢ Sound Level Meters « Bridges (S16) 334-5959 + (600) 990.0436 formerly manufactured by GenRad Long Isand, NY + Ema: info@ietibs.com wo etats cam abc ones 7 Calibration Certificate of Calibration Laboratory Certificate Number: 20210429-73444 ee Manufacturer: IET Labs, Inc, Sul Model: VRS-100-10-10K-BP-10KV Description: High Resistance Standard Serial Number: £3-1914504 Customer Designation: itandards And Tools Used Manufacturer Model Fluke en Flake aeasa Julie Research Labs KW 2. TET Labs, In SRL-100% TET Labs, Inc. SRI~100M TET Labe, Inc. SRL-10¢ ~ TET Labs, Ine. SRL-10¥ 84 Digit sigh rc Standard Resistor, 100 ka Standard Resietor, 100 Mf Standard Resi: Standard Resi TET Labs, Ine. Standaz TET Labs, Inc SRL-IM Standa: Calibration 1ET Labs nc ration Date: Facility; 1202 VFW Parkway West Roxbury, MA 02132 Next Recommended Page 2 of 6 IET LABS, INC. Calibration Date: bmitted By: Tan Delta Electric Corporation Tandelco Bidg., 34A J.P. Rizal St, Project 4 Quezon City 1109, Phillipines Description Serial Number Cal Date Due Date ference Multimeter 976157026 06-gul-2020 06-Jui-2i sion Multimeter 4591016 05-May-2020. 05-May-22 voltage Divider -Jui-20 nd Temperature Logger Fr, 10 ko Ad-mar-2021 27-aul-2 10 ca 29.Apr21 Jon Authorize Signe vn Certificate or report shall not be reproduced except in full without approval of IET Labs, Inc. Standards * Decades * Strobes © Sound Level Meters * Bridges (516) 334-5959 + (600) 99.6438 formerly manufactured by GenRad Long Island, NY.» Email info@ietiabs.com wv ietabs.com Age Nan: CPC 08 Calibration meee Certificate of Calibration Laboratory Certificate Number: 20210429-73444 Soret (REEREBRED) Manufacturer: IET Labs, Inc. ‘Submitted By: Tan Delta Electric Corporation Model: VRS-100-10-10K-BP-10KV_ Tandelco Bidg., 34A J.P. Rizal St. Description: High Resistance Standard Project 4 Serial Number: E3-1914504 Quezon City 1109, Phillipines Customer Designation: ET teem 1D # Si086 Test Description: As Returned Environmental ‘Temp (Deg C): ie F ‘Conditions: RH): 26.0 ‘Test Conditions: ao mst vounae rans. ne oma 100 v up 100 0 ca ° 100 6a 0.35 070 1s Page 3 of 6 Certificate or report shall not be reproduced except in full without approval of IET Labs, Inc. IET LABS, INC. ‘Standards ¢ Decades « Strobes * Sound Level Meters * Bridges (S16) 334-5959 » (800) 899-8438 formerly manufactured by GenRad Lor isend, NY + Email: infoietabscom eietabs com eons Certificate of Calibration cane Certificate Number: 20210429-73444 Srorst, GESeBRED Manufacturer: 1ET Labs, Inc. ‘Submitted By: Tan Delta Electric Corporation Model: VRS-100-10-10K-BP-10KV Tandelco Bidg., 34A J.P. Rizal St. Description: High Resistance Standard Project 4 Serial Number: E3-1914504 Quezon City 1109, Phillipines Customer Designation aes Test Report Number: 128406 ee Test Description: As Returned - 5000 V Environmental Temp (Deg Tost Version: 8.2 Conditions: RH (mt ‘Test Conditions: roMnI Serene —— 7 ov at nae 99.861 19 mo 0.998 082 2 Ga 0.5 a 10.027 605 Ga 0.5 100 60 5 70 2. ™ 2.78 Page 4 of 6 Certificate or report shall not be reproduced except in full without approval of IET Labs, Inc. IET LABS, INC. Standards © Decades Strobes © Sound Level Meters ¢ Bridges (516) 334-5959 + (600) 599-8438 formerly manufactured by GenRad Long sand, NY + Ema: info@ietabs.com eva itas.com ea: agra 02 Ce 1 Certificate Number: 20210429-73444 ¥2073.01 (GECREBIFED) ‘Manufacturer: IET Labs, Inc. ‘Submitted By: Tan Delta Electric Corporation Model: VRS-100-10-10K-BP-10KV Tandelco Bidg., 34A J.P. Rizal St. Description: High Resistance Standard Project 4 Serial Number: £3-1914504 Quezon City 1109, Phillipines Customer Designation: {ET hem 1D 6 s3686 ‘Test Report Number: 128369 rs Test Description: As Received Environmental Temp (Deg C): 22-8 Conditions: RH (%y: 26.0 Test Version: °.2 ‘Test Conditions: Page 5 of 6 Certifies of report shall not be reproduced except in full without approval of IET Labs, Inc. IET LABS, INC. Standards # Decades * Strobes * Sound Level Meters ¢ Bridges (516) 334-5959 + (600) 999-6438 formerly manufactured by GenRad — Long island, NY + Email: info@ietiabs.com wv ietabs.com Calibration ae eee Certificate of Calibration Laboratory gm] Certificate Number: 20210429-73444 Score, (ReERE Manufacturer: IET Labs, Inc. ‘Submitted By: Tan Delta Electric Corporation Model: VRS-100-10-10K-BP-10KV Tandelco Bidg., 34A J.P. Rizal St. Description; High Resistance Standard Project 4 Serial Number: E9-1914504 Quezon City 1108, Phillipines Customer Designation: rae Test Report Number: 128378 ae Tost Description: As Received - 5000 v Environmental ‘Temp (Deg C} ‘Conditions: RH (%) Test Date: 28-Apr Tech: cit 1 Test Version: 8.2 ‘Test Conditions: Page 6 of 6 Certificate or report shall not be reproduced except in full without approval of IET Labs, Inc. IET LABS, INC. ‘Standards ¢ Decades © Strobes * Sound Level Meters * Bridges (516) 334-5959 + (800) 899-8438 formerly manufactured by GenRad Long send, NY + Ema noGietabs com eis com

You might also like