You are on page 1of 2

Security through innovation

Count-Tact™ Range

à la source de la santé,
la pertinence du diagnostic
Count-Tact™ Range
The reference in environmental microorganism
detection and/or enumeration.

● For use in complete safety


• The validation of Count-TactTM
media demonstrated their neutralizing FOR USE IN AN CLEAN AREA
capacity with regard to commonly Reference Description Packaging
used antiseptics. The presence of 4 43501 Count-Tact - agar
TM
20 plates
neutralizing agents, lecithin,
43582 Count-TactTM GTS - agar without neutralizers 20 plates
polysorbate 80, L-histidine and
43580 Count-TactTM Sabouraud Dextrose Chloramphenicol 20 plates
sodium thiosulfate inactivates most
12-02 / 006GB99019A / This document is not legally binding. bioMérieux reserves the right to modify specifications without notice . BIOMERIEUX and the blue logo, Count-Tact, air IDEAL are registered and protected trademarks belonging to bioMérieux sa or one of its subsidiaries .

with Neutralizers – agar


residual disinfectants.
OTHER FORMULATIONS: CONTACT YOUR LOCAL BIOMERIEUX REPRESENTATIVE.
• Fertility testing, for each lot
produced, includes the enumeration FOR USE IN A PROTECTED AREA
of the strains recommended by
- The Count-Tact™ irradiated range was specifically designed for use in clean areas. The
pharmacopeias (U.S.P, E.P, J.P). plates are packaged in packs of 10 in triple Cellophane wrapping receiving an irradiation
• Stability is established in real time dose between 8 and 12 kGray.
and includes thermal shocks in order - The validation demonstrated that an 8 kGray dose guarantees the absence of bacterial
to account for extreme temperature growth after artificial contamination. A 12 kGray dose does not modify the medium's
variations liable to be encountered performance: stability, fertility, selectivity, neutralization.
under exceptional circumstances. - Count-Tact™ irradiated medium has the same performance as Count-Tact™ non-irradiated
medium.

Reference Description Packaging


● Reliability of collections
43491 Count-TactTM Irradiated - agar 20 plates
• Count-TactTM FIX SYSTEMTM plates 43492 Count-TactTM Irradiated - agar 100 plates
guarantee the quality of collections
43581 Count-TactTM Irradiated Sabouraud Dextrose
by limiting the risk of accidental Chloramphenicol with Neutralizers – agar 20 plates
opening.
• The Count-Tact TM Applicator
standardizes surface collections in FOR USE IN ISOLATORS
terms of time and pressure. ISOLATOR Count-TactTM Irradiated plates are packaged in triple wrapping:
• The BI - BOX is a sterile box for - one primary cellophane wrapping
collecting, transporting and incubating - one secondary gas-impermeable aluminum sachet providing perfect protection of the
10 Count-Tact™ plates. media against peracetic acid and hydrogen peroxide.
- protective cellophane wrapping ensuring overall integrity until introduction into the
isolator.
FOR FURTHER DETAILS, CONSULT
THE TECHNICAL SHEETS. Reference Description Packaging
43593 new! ISOLATOR Count-TactTM Irradiated – agar 20 plates
Photo N. Bouchut . Printed in France . THERA McCann Healthcare . RCS Lyon B 398 160 242

EQUIPMENT
Reference Description Packaging
96301 new! BI-BOX 10 sterile cases in double wrapping
96300 Count-Tact applicator
TM
Applicator for Count-TactTM
plates
96303 air IDEAL® Air sampler for Count-TactTM
plates