Installation,
Operation,And
Maintenance
? G U I D E
Installation Maintenance
Install valve in system using proper size threaded KF Series 31 Check Valves are permanently lubricat-
end connections. A quality thread sealant/lubri- ed and normally require no routinemaintenance.
cant should be used for proper make-up. Observe
the following precautions: Reconditioning
• Inspect male pipe thread for damage prior to Important! Prior to disassembly, valve must first
installation. Do not over tighten. be isolated from system pressure and flow.
• Do not install the valve whereby it directly dis- Disc Removal: After observing the above pre-
charges downstream into a tee or elbow fitting. caution, the valve is ready to be serviced. At the
• KF Series 31 Check Valves should not be used option of the service personnel, the valve may be
for vertical downflow installations. removed from the pipeline or serviced in line.
• KF Series 31 Check Valves should not be used in Remove the threaded, bonnet and bonnet seal. Lift
severe pulsating services such as reciprocating disc and bushings out of trough in body, together.
compressor discharges. For valves which include an integral face seal in
• It is recommended that the check valves be the disc, seal may be removed from it's dovetail
installed a minimum of three pipe diameters down- holding groove. Clean and inspect seal and
stream of the pump or compressor. groove area.
• KF suggests installing the check valves down- Clean and inspect all parts for wear and/or dam-
stream of the silencer in an air or gaseous system. age. Cuts or nicks in any seal is cause for replace-
• KF suggests installing the check valves downstream ment. Flush all foreign matter from bonnet seal and
of any pulsation dampeners in any system. seat areas.
3 2 14 11
6
1
Parts List
No. Description
1 Body
2 Bonnet
3 Disc
5 Bushing
6 Disc Seal
11 Bonnet Seal
14 Plug, Bonnet