APEX APEX AR. EMMARIE ROSE C. JOSUE, UAP
Project:
FRONT ELEVATION REAR ELEVATION RIGHT SIDE ELEVATION LEFT SIDE ELEVATION MR. & MRS. LEUTERIO
RESIDENCE
Location:
CAINTA RIZAL
APEX APEX
FB1
DIRECTED TO MEET SPECIAL
FB1
FB1
FB1
S1 S1 RB2 RB2
CONDITIONS. C1F1 FB2 FB2 C1F1 FB2 FB2
RB1
RB1
2. CONTRACTOR SHALL
RB1
RB1
VERIFY ALL DIMENSIONS RB2 RB2
FB3
FB2 FB2
FB3
FB3
BEFORE ALL WORK IS TO BEGIN. S1 S1
3. SHORINGS AND BRACINGS REPUBLIC ACT NO. 9266
RB1
RB1
C1F1 FB2 C1F1
RB1
RB1
FB2
ARE TO BE PROVIDED BY THE FB2 FB2 SEC. 33
CONTRACTOR FOR ALL LOADS ARCHITECTURE ACT OF
RB2 RB2
THAT MAYBE IMPOSED DURING
FB3
2004
FB3
FB3
CONSTRUCTION. S1 S1
4. ALL MATERIALS AND DRAWINGS & SPECIFICATIONS DULY
C1F1 FB2 FB2 C1F1
RB1
RB1
SIGNED, STAMPED OR SEALED AS AN
RB1
RB1
WORKMANSHIP SHALL FB2 FB2
CONFORM WITH THE LATEST INSTRUMENT OF SERVICE, ARE THE
BUILDING CODE OF AMERICAN
RB2 RB2 PROPERTY AND DOCUMENTS OF THE
ARCHITECT, WHETHER THE OBJECT FOR
CONCRETE INSTITUTE (ACI-318)
WHICH THEY ARE MADE IS EXECUTED OR
5. REINFORCING BARS
NOT. IT SHALL BE UNLAWFUL FOR ANY
SHALL BE GRADE 40 FOR 12MM
PERSON, WITHOUT THE WRITTEN
DIA AND SMALLER. GRADE 60
CONSENT OF THE ARCHITECT OR AUTHOR
FOR 16MM DIA AND LARGER
OF SAID DOCUMENTS TO DUPLICATE OR
(ASTM A615) ROOF BEAM PLAN ROOF FRAMING PLAN MAKECOPIES OF SAID DOCUMENTS FOR
6. SPLICES SHALL BE USE IN THE REPETITION & FOR OTHER
SECURELY WIRED TOGETHER IN PROJECTS OR BUILDERS WHETHER
ADHERENCE WITH THE
STRUCTURAL CODE OF THE
FOUNDATION PLAN FLOOR FRAMING PLAN EXECUTEDPARTLYORINWHOLE.
PHILIPPINES
STRUCTURAL
SUPPORT MIDSPAN SUPPORT
L/3 L/3
CIVIL ENGINEER
L/4
10MM STIRRUPS 1@50MM, 5@
100MM O.C. REST @ 200MM CL SECTION A
TOP BAR
A
L/4 L/4
L/2
BOTTOM BAR
L/4 L/2 L4
BEAM DETAIL
B
L/4
PLAN OF S1
Project:
BEAM SCHEDULE COLUMN SCHEDULE
MARK SIZE
0.20
AT LEFT SUPPORT AT MIDSPAN AT RIGHT SUPPORT L/4 L/2 L4 MR. & MRS. LEUTERIO
3-12MMØ 3-12MMØ 3-12MMØ S I Z E
MARK VERTICAL BARS TIES
SECTION B RESIDENCE
0.30
S I Z E
2-16MMØ 3-16MMØ 2-16MMØ
MARK C X C X D
VERTICAL BARS CAINTA RIZAL
0.20
4-16MMØ 2-16MMØ 4-16MMØ
FB3
0.30
Sheet Contents:
FOUNDATION PLAN, FLOOR & ROOF FRAMING
COLUMN FOOTING DETAIL TRUSS DETAIL PLANS, DETAILS AND SCHEDULES OF BEAMS,
COLUMNS AND SLABS, TRUSS DETAIL
Checked by ECJ
1000
S-1
300
Scale 1:100M
ALL ELECTRICAL WORKS HEREIN HAS BEEN EXECUTED IN ACCORDANCE WITH THE
PROVISIONS OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE, THE
LAWS & ORDINANCES OF THE LOCAL CODE ENFORCING AUTHORITIES AND THE
REQUIREMENTS OF THE LOCAL POWER AND TELEPHONE COMPANY.
VOLTS.
TRADE SIZE CONDUIT, WIRE SHALL BE INSULATED FOR 600
2 e
Se
e
3. ALL BRANCH CIRCUIT HOME RUN HAS BEEN INSTALLED AS INDICATED Sab
f REPUBLIC ACT NO. 9266
IN THE PLAN. EXPOSED CIRCUIT RUN SHALL BE INSTALLED PARALLEL 4 Sab
cd
l
l
KIT
SEC. 33
TO OR PERPENDICULAR WITH THE BUILDING LINE AND SUPPORTED
BILLIARDS KIT
BY CONDUIT CLAMPS EVERY 1.5 METERS, DIAGONAL CONDUIT RUN
SHALL NOT BE ACCEPTED. a
BILLIARDS b
Sf
ARCHITECTURE ACT OF
4. WHENEVER NECESSARY PULL BOX OF PROPER SIZE AND DIMENSION GFCI
3 2004
SHALL BE PROVIDED ALTHOUGH NOT INDICATED IN THE PLAN. ALL a b
JUNCTION BOXES HAS BEEN EXECUTED WITH METAL PLATE COVER.
Sh
i
j
Sg DRAWINGS & SPECIFICATIONS DULY
i
5. ALL LIGHT CONTROLLED SWITCHES SHALL BE RATED 15 AMPS , GFCI GFCI
h
SIGNED, STAMPED OR SEALED AS AN
220VAC SWITCHES SHALL HAD BEEN INSTALLED FOR OPERATION CARPORT 5 BEDROOM T&B
1 BEDROOM INSTRUMENT OF SERVICE, ARE THE
WITH HORIZONTAL MOTION. j
PROPERTY AND DOCUMENTS OF THE
6. ALL PANEL BOARD HAD BEEN PROVIDED WITH GROUNDING
T&B
TERMINALS. GROUNDING SYSTEMS SHALL BE CONNECTED TO THE CARPORT ARCHITECT, WHETHER THE OBJECT FOR
i Sj h
GROUND.ALL BRANCH CIRCUIT FOR LIGHTING AND OUTLET SHALL WHICH THEY ARE MADE IS EXECUTED OR
NOT BE THE COMBINED IN THE SAME RACEWAY. NOT. IT SHALL BE UNLAWFUL FOR ANY
7. ALL METALLIC CONDUIT , CABINET, BOXES, AND EQUIPMENT HAD c d
PERSON, WITHOUT THE WRITTEN
BEEN EXECUTED PROPERLY GROUNDED AND BONDED.
8. ALL MATERIALS USED HAD BEEN NEW AND APPROVED FOR THE CONSENT OF THE ARCHITECT OR AUTHOR
LOCATION AND PURPOSES.BOXES HAD BEEN MADE OF CODE GAUGE OF SAID DOCUMENTS TO DUPLICATE OR
STEEL WITH ZINC CHROMATE PROTECTION. MAKECOPIES OF SAID DOCUMENTS FOR
9. ALL RECEPTACLE OUTLET HAD BEEN EXECUTED PROPERLY
GROUNDED TO THE BOX BY MEANS OF GROUNDING LUGS.
USE IN THE REPETITION & FOR OTHER
10. CONDUIT SLEEVES AND FLOOR SLOT PENETRATION THROUGH PROJECTS OR BUILDERS WHETHER
ELECTRICAL AND TELEPHONE ROOM AND WALLS HAD BEEN EXECUTEDPARTLYORINWHOLE.
PROPERLY SEALED OF WITH FIRE RETARDANT MATERIALS TO
MAINTAIN FIRE RESISTIVE RATINGS OF THE FLOOR OPENING.
11. ALL LIGHTING INSTALLATIONS HAD BEEN PROTECTED BY MICA TUBE
PRIOR TO ITS INSERTION TO THE METALLIC FLEXIBLE CONDUIT.
ELECTRICAL
12. DISCREPANCIES BETWEEN PLANS AND SPECIFICATION HAD BEEN BE
REFERRED TO ENGINEER/ARCHITECT GROUND FLOOR PLAN SECOND FLOOR PLAN GROUND FLOOR PLAN SECOND FLOOR PLAN
13. ELECTRICAL CONTRACTOR SHOULD REFER TO ARCHITECTURAL
DRAWINGS FOR THE EXACT LOCATION AND MOUNTING HEIGHT OF
ALL VISIBLE WIRING DEVICES, LIGHTING FIXTURES AND THE LIKES.
POWER LAYOUT POWER LAYOUT LIGHTING LAYOUT LIGHTING LAYOUT
14. ALL ELECTRICAL WORKS HAD BEEN EXECUTED UNDER THE DIRECT
AND IMMEDIATE SUPERVISION OF A DULY QUALIFIED LICENSED PROFESSIONAL ELECTRICAL
ELECTRICAL ENGINEER. ENGINEER
50MM DIA
SINK
KS
BILLIARDS KIT BILLIARDS KIT
SSWDVS
FCO
LAV
BEDROOM T&B
WC BEDROOM T&B
LAV
FCO
REPUBLIC ACT NO. 9266
CARPORT CARPORT WC
SEC. 33
100MM DIA
50MM DIA
SHO FD FD
ARCHITECTURE ACT OF
2004
DRAWINGS & SPECIFICATIONS DULY
GV
SIGNED, STAMPED OR SEALED AS AN
TO DRAINAGE
WM WM
INSTRUMENT OF SERVICE, ARE THE
TO DRAINAGE
PROPERTY AND DOCUMENTS OF THE
TO SEWER
CV
ARCHITECT, WHETHER THE OBJECT FOR
WHICH THEY ARE MADE IS EXECUTED OR
NOT. IT SHALL BE UNLAWFUL FOR ANY
PERSON, WITHOUT THE WRITTEN
CONSENT OF THE ARCHITECT OR AUTHOR
OF SAID DOCUMENTS TO DUPLICATE OR
MAKECOPIES OF SAID DOCUMENTS FOR
GROUND FLOOR PLAN SECOND FLOOR PLAN GROUND FLOOR PLAN SECOND FLOOR PLAN USE IN THE REPETITION & FOR OTHER
MATERIAL SPECIFICATION WATER SUPPLY LAYOUT WATER SUPPLY LAYOUT SANITARY LAYOUT SANITARY LAYOUT PROJECTS OR BUILDERS WHETHER
EXECUTEDPARTLYORINWHOLE.
VERIFY
Location:
300 1200 300
SECTION
CAPPED
CAINTA RIZAL
VARIES
600 600 500
CAPPED
80
1800
200
450
200
25Ø AIR 32Ø AIR
VA
C VP LAYOUT, ISOMETRIC LAYOUT, PLUMBING DETAILS,
CHAMBER CHAMBER 0Ø
CAPPED
CATCH BASIN 300
5
50
Ø
NOTE: REFER STRUCTURAL PLANS
FOR STRUCTURAL DETAILS DETAIL VA
C
Project number 0009
.C
2500 800 TO FIXTURES TO FIXTURES K
P.O Date AUGUST 21, 2021
SIN WS
WATERPROOFING SOIL / WASTE LINE : 65 TO 110 PVC
PIPE, BY MOLDEX OR NELTEX
LA
V
10
0Ø 50
Ø
.C
DETAILS
V
ECJ
800
100MM DIA
CO P.O Drawn by
FCO MH GROUT, COMPRESSIBLE
F SP
0Ø
FILLER
20ØCWL 25ØCWL 10 CO 0Ø
1750
F 0
30 X 30 CERAMIC 0Ø WC 1
MH TILE 10
INLET 100MM DIA PLUMBING DRY SET CEMENT
MORTAR BOND COAT
FD
Checked by ECJ
800
FIXTURE
FCO MH
OUTLET (LIGHTWEIGHT FOAMED
DC FLOOR CEMENT CONCRETE FILLER
FIN.
TO CONCRETE HALLOW
WASTE
BLOCKS
CONCRETE SLAB PS-1
FOR STRUCTURAL DETAILS LINE
STUB-OUT
FR. SUPPLY FR. SUPPLY
SANITARY/WASTE ISOMETRIC VIEW
FLOOR CLEAN OUT DETAIL
DETAIL OF AIR CHAMBER 1:100M
SEPTIC TANK DETAIL Scale