BILLIARDS KIT BILLIARDS KIT

REPUBLIC ACT NO. 9266


SEC. 33
CARPORT
ARCHITECTURE ACT OF
T&B
CARPORT BEDROOM BEDROOM 2004
T&B DRAWINGS & SPECIFICATIONS DULY
SIGNED, STAMPED OR SEALED AS AN
INSTRUMENT OF SERVICE, ARE THE
PROPERTY AND DOCUMENTS OF THE
ARCHITECT, WHETHER THE OBJECT FOR
WHICH THEY ARE MADE IS EXECUTED OR
NOT. IT SHALL BE UNLAWFUL FOR ANY
PERSON, WITHOUT THE WRITTEN
CONSENT OF THE ARCHITECT OR AUTHOR
OF SAID DOCUMENTS TO DUPLICATE OR
MAKECOPIES OF SAID DOCUMENTS FOR
USE IN THE REPETITION & FOR OTHER
PROJECTS OR BUILDERS WHETHER
EXECUTEDPARTLYORINWHOLE.
GROUND FLOOR PLAN SECOND FLOOR PLAN GF REFLECTED CEILING PLAN 2F REFLECTED CEILING PLAN
ARCHITECTURAL

APEX APEX
APEX APEX AR. EMMARIE ROSE C. JOSUE, UAP

ROOF BEAM ROOF BEAM


ROOF BEAM ROOF BEAM

2F FIN LINE 2F FIN LINE


2F FIN LINE 2F FIN LINE Description Date

GF FIN LINE GF FIN LINE GF FIN LINE


GF FIN LINE

Project:
FRONT ELEVATION REAR ELEVATION RIGHT SIDE ELEVATION LEFT SIDE ELEVATION MR. & MRS. LEUTERIO
RESIDENCE
Location:

CAINTA RIZAL
APEX APEX

SEE TRUSS DETAIL SEE TRUSS DETAIL Sheet Contents:


ROOF BEAM ROOF BEAM ARCHITECTURAL FLOOR PLANS,
T&B REFLECTED CEILING PLANS,
ELEVATIONS, SECTIONS, ROOF PLANS
BILLIARDS KIT
KEYPLAN
Project number 0009
2F FIN LINE 2F FIN LINE
Date AUGUST 21, 2021
CARPORT
CARPORT Drawn by ECJ
GF FIN LINE
GF FIN LINE (CARPORT) Checked by ECJ
ROOF PLAN
CROSS SECTION LONGITUDINAL SECTION ROOF PLAN AR-1
Scale 1:100M
1. CONSTRUCTION NOTES
AND TYPICAL DETAILS APPLY
YO ALL DRAWINGS UNLESS
OTHERWISE SHOWN OR NOTED.
MODIFY TYPICAL DETAILS AS FB1 FB1

FB1
DIRECTED TO MEET SPECIAL

FB1

FB1

FB1
S1 S1 RB2 RB2
CONDITIONS. C1F1 FB2 FB2 C1F1 FB2 FB2

RB1

RB1
2. CONTRACTOR SHALL

RB1

RB1
VERIFY ALL DIMENSIONS RB2 RB2

FB3
FB2 FB2

FB3

FB3
BEFORE ALL WORK IS TO BEGIN. S1 S1
3. SHORINGS AND BRACINGS REPUBLIC ACT NO. 9266

RB1

RB1
C1F1 FB2 C1F1

RB1

RB1
FB2
ARE TO BE PROVIDED BY THE FB2 FB2 SEC. 33
CONTRACTOR FOR ALL LOADS ARCHITECTURE ACT OF
RB2 RB2
THAT MAYBE IMPOSED DURING

FB3
2004

FB3

FB3
CONSTRUCTION. S1 S1
4. ALL MATERIALS AND DRAWINGS & SPECIFICATIONS DULY
C1F1 FB2 FB2 C1F1

RB1

RB1
SIGNED, STAMPED OR SEALED AS AN

RB1

RB1
WORKMANSHIP SHALL FB2 FB2
CONFORM WITH THE LATEST INSTRUMENT OF SERVICE, ARE THE
BUILDING CODE OF AMERICAN
RB2 RB2 PROPERTY AND DOCUMENTS OF THE
ARCHITECT, WHETHER THE OBJECT FOR
CONCRETE INSTITUTE (ACI-318)
WHICH THEY ARE MADE IS EXECUTED OR
5. REINFORCING BARS
NOT. IT SHALL BE UNLAWFUL FOR ANY
SHALL BE GRADE 40 FOR 12MM
PERSON, WITHOUT THE WRITTEN
DIA AND SMALLER. GRADE 60
CONSENT OF THE ARCHITECT OR AUTHOR
FOR 16MM DIA AND LARGER
OF SAID DOCUMENTS TO DUPLICATE OR
(ASTM A615) ROOF BEAM PLAN ROOF FRAMING PLAN MAKECOPIES OF SAID DOCUMENTS FOR
6. SPLICES SHALL BE USE IN THE REPETITION & FOR OTHER
SECURELY WIRED TOGETHER IN PROJECTS OR BUILDERS WHETHER
ADHERENCE WITH THE
STRUCTURAL CODE OF THE
FOUNDATION PLAN FLOOR FRAMING PLAN EXECUTEDPARTLYORINWHOLE.

PHILIPPINES
STRUCTURAL
SUPPORT MIDSPAN SUPPORT

L/3 L/3

CIVIL ENGINEER

L/4
10MM STIRRUPS 1@50MM, 5@
100MM O.C. REST @ 200MM CL SECTION A
TOP BAR
A
L/4 L/4

L/2
BOTTOM BAR
L/4 L/2 L4

VARIES AR. EMMARIE ROSE C. JOSUE, UAP

BEAM DETAIL
B

L/4
PLAN OF S1
Project:
BEAM SCHEDULE COLUMN SCHEDULE
MARK SIZE
0.20
AT LEFT SUPPORT AT MIDSPAN AT RIGHT SUPPORT L/4 L/2 L4 MR. & MRS. LEUTERIO
3-12MMØ 3-12MMØ 3-12MMØ S I Z E
MARK VERTICAL BARS TIES
SECTION B RESIDENCE
0.30

RB1 3-12MMØ 3-12MMØ 3-12MMØ


A X B

C1 0.20M 0.40M 8-16MMØ 10MMØ


SLAB DETAIL
0.20
2-16MMØ 2-16MMØ 2-16MMØ
FB1
SLAB DETAIL
0.30

2-16MMØ 2-16MMØ 2-16MMØ Location:


FB2
0.20
3-16MMØ 2-16MMØ 3-16MMØ FOOTING SCHEDULE L/4 L/2 L4
0.30

S I Z E
2-16MMØ 3-16MMØ 2-16MMØ
MARK C X C X D
VERTICAL BARS CAINTA RIZAL
0.20
4-16MMØ 2-16MMØ 4-16MMØ
FB3
0.30

3-16MMØ 5-16MMØ 3-16MMØ F1 1.00M 1.00M 0.3M 6-16MMØ

Sheet Contents:
FOUNDATION PLAN, FLOOR & ROOF FRAMING

COLUMN FOOTING DETAIL TRUSS DETAIL PLANS, DETAILS AND SCHEDULES OF BEAMS,
COLUMNS AND SLABS, TRUSS DETAIL

1000 Project number 0009


Date AUGUST 21, 2021
Drawn by ECJ
1138

Checked by ECJ
1000

S-1
300

Scale 1:100M
ALL ELECTRICAL WORKS HEREIN HAS BEEN EXECUTED IN ACCORDANCE WITH THE
PROVISIONS OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE, THE
LAWS & ORDINANCES OF THE LOCAL CODE ENFORCING AUTHORITIES AND THE
REQUIREMENTS OF THE LOCAL POWER AND TELEPHONE COMPANY.

1. SERVICE POWER HAS BEEN EXECUTED AS SINGLE PHASE, WIRING


METHOD EXECUTED AS IN UPVC FOR LIGHTING, POWER AND
AUXILIARY SYSTEM.
2. SMALLEST BRANCH CIRCUIT WIRE HAS BEEN EXECUTED AS 3.5MM2
THHN FOR POWER AND LIGHTING SYSTEM IN RACEWAY 12MM DIA

VOLTS.
TRADE SIZE CONDUIT, WIRE SHALL BE INSULATED FOR 600
2 e
Se
e

3. ALL BRANCH CIRCUIT HOME RUN HAS BEEN INSTALLED AS INDICATED Sab
f REPUBLIC ACT NO. 9266
IN THE PLAN. EXPOSED CIRCUIT RUN SHALL BE INSTALLED PARALLEL 4 Sab
cd
l
l
KIT
SEC. 33
TO OR PERPENDICULAR WITH THE BUILDING LINE AND SUPPORTED
BILLIARDS KIT
BY CONDUIT CLAMPS EVERY 1.5 METERS, DIAGONAL CONDUIT RUN
SHALL NOT BE ACCEPTED. a
BILLIARDS b
Sf
ARCHITECTURE ACT OF
4. WHENEVER NECESSARY PULL BOX OF PROPER SIZE AND DIMENSION GFCI
3 2004
SHALL BE PROVIDED ALTHOUGH NOT INDICATED IN THE PLAN. ALL a b
JUNCTION BOXES HAS BEEN EXECUTED WITH METAL PLATE COVER.
Sh
i
j
Sg DRAWINGS & SPECIFICATIONS DULY
i
5. ALL LIGHT CONTROLLED SWITCHES SHALL BE RATED 15 AMPS , GFCI GFCI
h
SIGNED, STAMPED OR SEALED AS AN
220VAC SWITCHES SHALL HAD BEEN INSTALLED FOR OPERATION CARPORT 5 BEDROOM T&B
1 BEDROOM INSTRUMENT OF SERVICE, ARE THE
WITH HORIZONTAL MOTION. j
PROPERTY AND DOCUMENTS OF THE
6. ALL PANEL BOARD HAD BEEN PROVIDED WITH GROUNDING
T&B
TERMINALS. GROUNDING SYSTEMS SHALL BE CONNECTED TO THE CARPORT ARCHITECT, WHETHER THE OBJECT FOR
i Sj h
GROUND.ALL BRANCH CIRCUIT FOR LIGHTING AND OUTLET SHALL WHICH THEY ARE MADE IS EXECUTED OR
NOT BE THE COMBINED IN THE SAME RACEWAY. NOT. IT SHALL BE UNLAWFUL FOR ANY
7. ALL METALLIC CONDUIT , CABINET, BOXES, AND EQUIPMENT HAD c d
PERSON, WITHOUT THE WRITTEN
BEEN EXECUTED PROPERLY GROUNDED AND BONDED.
8. ALL MATERIALS USED HAD BEEN NEW AND APPROVED FOR THE CONSENT OF THE ARCHITECT OR AUTHOR
LOCATION AND PURPOSES.BOXES HAD BEEN MADE OF CODE GAUGE OF SAID DOCUMENTS TO DUPLICATE OR
STEEL WITH ZINC CHROMATE PROTECTION. MAKECOPIES OF SAID DOCUMENTS FOR
9. ALL RECEPTACLE OUTLET HAD BEEN EXECUTED PROPERLY
GROUNDED TO THE BOX BY MEANS OF GROUNDING LUGS.
USE IN THE REPETITION & FOR OTHER
10. CONDUIT SLEEVES AND FLOOR SLOT PENETRATION THROUGH PROJECTS OR BUILDERS WHETHER
ELECTRICAL AND TELEPHONE ROOM AND WALLS HAD BEEN EXECUTEDPARTLYORINWHOLE.
PROPERLY SEALED OF WITH FIRE RETARDANT MATERIALS TO
MAINTAIN FIRE RESISTIVE RATINGS OF THE FLOOR OPENING.
11. ALL LIGHTING INSTALLATIONS HAD BEEN PROTECTED BY MICA TUBE
PRIOR TO ITS INSERTION TO THE METALLIC FLEXIBLE CONDUIT.
ELECTRICAL
12. DISCREPANCIES BETWEEN PLANS AND SPECIFICATION HAD BEEN BE
REFERRED TO ENGINEER/ARCHITECT GROUND FLOOR PLAN SECOND FLOOR PLAN GROUND FLOOR PLAN SECOND FLOOR PLAN
13. ELECTRICAL CONTRACTOR SHOULD REFER TO ARCHITECTURAL
DRAWINGS FOR THE EXACT LOCATION AND MOUNTING HEIGHT OF
ALL VISIBLE WIRING DEVICES, LIGHTING FIXTURES AND THE LIKES.
POWER LAYOUT POWER LAYOUT LIGHTING LAYOUT LIGHTING LAYOUT
14. ALL ELECTRICAL WORKS HAD BEEN EXECUTED UNDER THE DIRECT
AND IMMEDIATE SUPERVISION OF A DULY QUALIFIED LICENSED PROFESSIONAL ELECTRICAL
ELECTRICAL ENGINEER. ENGINEER

15. MOUNTING HEIGHT NOT SHOWN ON SCHEDULE ARE AS FOLLOWS:


A. LIGHT CONTROLLED SWITCHES…………1.4MTS ABOVE FLOOR FINISH LEGEND :
B. DUPLEX CONVENIENCE OUTLET………....0.3MTS ABOVE FLOOR FINISH
C. TELEPHONE OUTLET………………………..0.3MTS ABOVE FLOOR FINISH LED LITE DOWN LIGHT
D. PANELBOARD…………………………………1.4MTS ABOVE FLOOR FINISH
2-T8 LED ON DIFFUSER
AR. EMMARIE ROSE C. JOSUE, UAP
CIRCULAR LED LAMP
#OF #OF BRANCHES CONDUIT SIZE CIRCULAR LED LAMP
CKT NO. DESCRIPTION OUTLETSSWITCHES VOLTS VA AMPS TRIP POLE FRAME TYPE WIRE SIZE UPVC DIA DUPLEX OUTLET, WALL MOUNTED
DUPLEX OUTLET, WALL MOUNTED W/ GFCI
1 LIGHTING 4 1 230 400 1.74 20 2 20 MCCB 3.5MM2 THHN 20MM GFCI

PANEL BOARD Project:


2 LIGHTING 10 2 230 1000 4.35 20 2 20 MCCB 3.5MM2 THHN 20MM MR. & MRS. LEUTERIO
CIRCUIT NUMBER
3 LIGHTING 5 2 230 500 2.17 20 2 20 MCCB 3.5MM2 THHN 20MM RESIDENCE
4 CONVENIENCE OUTLET 6 230 1200 5.22 30 2 30 MCCB 3.5MM2 THHN 20MM WALL-EMBEDDED LINE FOR ELECTRICAL
Location:
5 CONVENIENCE OUTLET 2 230 400 1.74 30 2 30 MCCB 3.5MM2 THHN 20MM LINES FOR SWITCHES
CAINTA RIZAL
6 AIRCON 1 230 200 0.87 30 2 30 MCCB 3.5MM2 THHN 20MM SINGLE PHASE, 60HZ
7 SPARE 230 30 2 30 MCCB 3.5MM2 THHN 20MM MAIN SUPPLY
8 SPARE 230 30 2 30 MCCB 3.5MM2 THHN 20MM M Sheet Contents:
LIGHTING LAYOUT, POWER LAYOUT,
TOTAL 3700 16.09 100 AT 1P SCHEDULE OF LOADS, ONE-LINE DIAGRAM
LIGHTING 1 20 AT 1P 20 AT 1P
2 LIGHTING
TOTAL LOAD = 3,700 VA Project number 0009
IT=3,700/230= 16.09 AMPS LIGHTING 3 20 AT 1P 30 AT 1P
4 CONV OUTLET
Date AUGUST 21, 2021
FOR MAIN CIRCUIT BREAKER PROTECTION FOR MAIN SERVICE ENTRANCE WIRE
IT=1.25 X 16.09= 20.11 AMPERES CONV OUTLET 5 30 AT 1P 30 AT 1P
6 AIRCON
It=3,700/230 VA= 16.09AMPERES
Drawn by ECJ
USE: 100 AT/SF SINGLE PHASE, 60HZ CIRCUIT BREAKER SPARE 7 30 AT 1P 30 AT 1P
8 SPARE
USE 2- 3.5MM2 THHN WIRE
Checked by ECJ
BRANCHES:

3- 20AT/AF. SINGLE PHASE, 60HZ, CB E-1


3-30AT/AF, SINGLE PHASE, 60HZ, CB
2-SPARE
RISER DIAGRAM Scale 1:100M
GENERAL NOTES

50MM DIA
SINK
KS
BILLIARDS KIT BILLIARDS KIT
SSWDVS
FCO

LAV
BEDROOM T&B
WC BEDROOM T&B
LAV

FCO
REPUBLIC ACT NO. 9266
CARPORT CARPORT WC

SEC. 33

100MM DIA

50MM DIA
SHO FD FD
ARCHITECTURE ACT OF
2004
DRAWINGS & SPECIFICATIONS DULY
GV
SIGNED, STAMPED OR SEALED AS AN

TO DRAINAGE
WM WM
INSTRUMENT OF SERVICE, ARE THE

TO DRAINAGE
PROPERTY AND DOCUMENTS OF THE

TO SEWER
CV
ARCHITECT, WHETHER THE OBJECT FOR
WHICH THEY ARE MADE IS EXECUTED OR
NOT. IT SHALL BE UNLAWFUL FOR ANY
PERSON, WITHOUT THE WRITTEN
CONSENT OF THE ARCHITECT OR AUTHOR
OF SAID DOCUMENTS TO DUPLICATE OR
MAKECOPIES OF SAID DOCUMENTS FOR
GROUND FLOOR PLAN SECOND FLOOR PLAN GROUND FLOOR PLAN SECOND FLOOR PLAN USE IN THE REPETITION & FOR OTHER
MATERIAL SPECIFICATION WATER SUPPLY LAYOUT WATER SUPPLY LAYOUT SANITARY LAYOUT SANITARY LAYOUT PROJECTS OR BUILDERS WHETHER
EXECUTEDPARTLYORINWHOLE.

LEGENDS: PLUMBING & SANITARY


VP VENT PIPE CO CLEAN-OUT TABLE OF DIMENSIONS
SP SOIL PIPE CCO CEILING CLEAN-OUT PIPE SIZE DIMENSION IN MM
DP DRAIN PIPE
DP DRAIN PIPE DS DOWN SPOUT A C D
FCO
PIPE (EMBEDDED) FLOOR CLEAN-OUT 50 38. 1 101. 6
FD FLOOR DRAIN 78 38. 1 127. 0 SQUARE STRAINER
SS SOIL STACK KS KITCHEN SINK 100 40. 0 152. 4 W/ SLOT OPENING
VS VENT STACK LAV LAVATORY 150 50. 8 177. 8
MASTER PLUMBER
PLUMBING FIXTURE CONN. SIZE SCH. DS DOWN SPOUT SP SEWER PIPE METMA MODEL
VAC VENT AT CEILING
TYPICAL PIPE SIZES: VS VENT STACK M - 2000 - G
VS 50Ø mm WC WATER CLOSET C
L SLOTTED DRAIN COVER
FD 50Ø mm SEEPAGE PAN
LAV 50Ø mm
WC 100Ø mm F.F.L
PLAN
GATE VALE FLOOR SLAB
CHECK VALVE
FINISH FLOOR AR. EMMARIE ROSE C. JOSUE, UAP
WM WATER METER LEVEL
COLD WATERLINE (MAIN)
COLD WATERLINE (BRANCHES)
FLOW(2% SLOPE) WATERPROOFING
WATERLINE RISER MEMBRANE
PIPE UP / DOWN PVC P TRAP
KS KITCHEN SINK
PVC PIPE
WATER SUPPLY ISOMETRIC VIEW
LAV LAVATORY
WC WATER CLOSET Project:
GV GATE VALVE
DETAIL OF FLOOR DRAIN
CV CHECK VALVE MR. & MRS. LEUTERIO
A RESIDENCE
2500 800
300

VERIFY

Location:
300 1200 300
SECTION
CAPPED
CAINTA RIZAL
VARIES
600 600 500

CAPPED
80
1800

200

VERTICAL PIPE HANGER DETAIL P.O


.C
Sheet Contents:
300

WATER SUPPLY LAYOUT, WASTE SANITARY

450
200
25Ø AIR 32Ø AIR
VA
C VP LAYOUT, ISOMETRIC LAYOUT, PLUMBING DETAILS,
CHAMBER CHAMBER 0Ø
CAPPED
CATCH BASIN 300
5
50
Ø
NOTE: REFER STRUCTURAL PLANS
FOR STRUCTURAL DETAILS DETAIL VA
C
Project number 0009
.C
2500 800 TO FIXTURES TO FIXTURES K
P.O Date AUGUST 21, 2021
SIN WS
WATERPROOFING SOIL / WASTE LINE : 65 TO 110 PVC
PIPE, BY MOLDEX OR NELTEX
LA
V
10
0Ø 50
Ø
.C
DETAILS
V
ECJ
800

100MM DIA
CO P.O Drawn by
FCO MH GROUT, COMPRESSIBLE
F SP

FILLER
20ØCWL 25ØCWL 10 CO 0Ø
1750

F 0
30 X 30 CERAMIC 0Ø WC 1
MH TILE 10
INLET 100MM DIA PLUMBING DRY SET CEMENT
MORTAR BOND COAT
FD
Checked by ECJ
800

FIXTURE
FCO MH
OUTLET (LIGHTWEIGHT FOAMED
DC FLOOR CEMENT CONCRETE FILLER
FIN.
TO CONCRETE HALLOW

NOTE: REFER STRUCTURAL PLANS


SOIL
/
0.20 M.

WASTE
BLOCKS
CONCRETE SLAB PS-1
FOR STRUCTURAL DETAILS LINE
STUB-OUT
FR. SUPPLY FR. SUPPLY
SANITARY/WASTE ISOMETRIC VIEW
FLOOR CLEAN OUT DETAIL
DETAIL OF AIR CHAMBER 1:100M
SEPTIC TANK DETAIL Scale