A-1 PERSPECTIVE

1 1 DNTS

FROM THE OFFICE OF: CIVIL ENGINEER: TITLE OF PROJECT : CHECKED BY : APPROVED AS TO PLAN & LOCATION : R.A. 5 4 4 , A R T I C L E I I I , S E C T I O N 1 9 : REVISIONS: SHEET CONTENTS SHEET NUMBER
IT SHALL BE UNLAWFUL FOR ANY PERSON TO ORDER OR OTHERWISE CAUSE PERSPECTIVE
THE CONSTRUCTION, RECONSTRUCTION, OR ALTERATION OF ANY BUILDING
NO. DATE DESCRIPTION
OR STRUCTURE INTENDED FOR PUBLIC GATHERING OR ASSEMBLY SUCH AS
THEATERS, CINEMATOGRAPHS, STADIA, CHURCHES OR STRUCTURES OF LIKE A-1
PROPOSED ADDITIONAL RSF (RAPID ENGR. ALFREDO T. CALINAWAN MR. RALPH MIGUEL LIM NATURE, AND ANY OTHER ENGINEERING STRUCTURES MENTIONED IN SECTION
REV. 0 23-MAY-23 ISSUED FOR APPROVAL
GENERAL MANAGER PRESIDENT
TWO OF THIS ACT UNLESS THE DESIGNS, PLANS, AND SPECIFICATIONS OF
SAME HAVE BEEN PREPARED UNDER THE RESPONSIBLE CHARGE OF, AND 1 2
DATE REG'D.:
SAND FILTER) AT WTP MALINGIN SIGNED AND SEALED BY A REGISTERED CIVIL ENGINEER, AND UNLESS THE
CONSTRUCTION, RECONSTRUCTION AND/OR ALTERATION THEREOF ARE
EXECUTED UNDER THE RESPONSIBLE CHARGE AND DIRECT SUPERVISION OF A
PRC.REG.NO.
CIVIL ENGINEER. PLANS AND DESIGNS OF STRUCTURES MUST BE APPROVED DRAWING NUMBER
AS PROVIDED BY LAW OR ORDINANCE OF A CITY OR PROVINCE OR
PTR NO. ISSUED ON: MUNICIPALITY WHERE THE SAID STRUCTURE IS TO BE CONSTRUCTED. WTPM-RSF-ED-002

RICHLI WATER ISSUED AT: TIN. : LOCATION: BRGY. PATROCINIO, CORTES, BOHOL ADDRESS: B. AQUINO ST., COGON, TAGBILARAN CITY, BOHOL ADDRESS: B. AQUINO ST., COGON, TAGBILARAN CITY, BOHOL
G.I BOX TYPE GUTTER

B-B B-B STEEL RAILINGS


A B C
A B C CHB PLASTERED FINISH

20.00

4.00 4.00 3.00 3.00 3.00 3.00 APEX LINE APEX LINE

0.55
TOP OF BEAM TOP OF BEAM
2.50 2.50
CEILING LINE CEILING LINE
1.25 1.25 1.25 1.25

0.25
2.70
1.30

1.30

1.30

1.30
1 1 FINISH FLOOR LINE FINISH FLOOR LINE

7.80
BEAM LINE BEAM LINE

0.30
RSF RSF RSF
3.60

3.60
RSF

3.70
A-A A-A
6.60

6.60
2 2 TOP OF SLAB TOP OF SLAB

NATURAL GROUND LINE NATURAL GROUND LINE

0.30
FRONT ELEVATION
3.00

3.00
A-2
2 2 SCALE 1 : 100 MTS

3 3
CHB PLASTERED FINISH G.I BOX TYPE GUTTER STEEL RAILINGS

STEEL RAILINGS C B A
4.00 4.00 3.00 3.00 3.00 3.00

20.00
APEX LINE APEX LINE

0.55
TOP OF BEAM TOP OF BEAM
B-B B-B
CEILING LINE CEILING LINE

0.25
A B C

2.70
A-2 FLOOR PLAN FINISH FLOOR LINE FINISH FLOOR LINE

7.80
2 2 SCALE 1 : 100 MTS
BEAM LINE BEAM LINE

0.30
RIB TYPE ROOFING

3.70
A B C

3" Ø DOWNSPOUT BOX TYPE GUTTER

10.00 TOP OF SLAB TOP OF SLAB

NATURAL GROUND LINE NATURAL GROUND LINE


1.00 8.00 1.00

0.30
A-2 REAR ELEVATION
2 2 SCALE 1 : 100 MTS
GUTTER LINE
1.00

1.00
RIB TYPE ROOFING
1 1 STEEL RAILINGS G.I BOX TYPE GUTTER
RIB TYPE ROOFING
SLOPE

SLOPE

1 2 3
GUTTER LINE

3 2 1

3.60
GUTTER LINE

RIB TYPE ROOFING


8.60

6.60

8.60
APEX LINE APEX LINE APEX LINE
2 2

0.55
TOP OF BEAM TOP OF BEAM TOP OF BEAM
1.00

CEILING LINE CEILING LINE CEILING LINE

0.25
GUTTER LINE
2.00

2.70
SLOPE

3 3
FINISH FLOOR LINE FINISH FLOOR LINE FINISH FLOOR LINE
1.00

1.00

7.80
BEAM LINE BEAM LINE BEAM LINE
GUTTER LINE

0.30
STEEL RAILINGS

3.70
1.00 4.00 1.00 3.00 1.00

10.00
3" Ø DOWNSPOUT
TOP OF SLAB TOP OF SLAB TOP OF SLAB

NATURAL GROUND LINE NATURAL GROUND LINE NATURAL GROUND LINE


A B C
0.30

A-2 ROOF PLAN A-2 LEFT-SIDE ELEVATION A-2 REAR-SIDE ELEVATION


2 2 SCALE 1 : 100 MTS 2 2 SCALE 1 : 100 MTS
2 2 SCALE 1 : 100 MTS

FROM THE OFFICE OF: CIVIL ENGINEER: TITLE OF PROJECT : CHECKED BY : APPROVED AS TO PLAN & LOCATION : R.A. 5 4 4 , A R T I C L E I I I , S E C T I O N 1 9 : REVISIONS: SHEET CONTENTS SHEET NUMBER
IT SHALL BE UNLAWFUL FOR ANY PERSON TO ORDER OR OTHERWISE CAUSE
THE CONSTRUCTION, RECONSTRUCTION, OR ALTERATION OF ANY BUILDING
NO. DATE DESCRIPTION
OR STRUCTURE INTENDED FOR PUBLIC GATHERING OR ASSEMBLY SUCH AS
THEATERS, CINEMATOGRAPHS, STADIA, CHURCHES OR STRUCTURES OF LIKE A-2
PROPOSED ADDITIONAL RSF (RAPID ENGR. ALFREDO T. CALINAWAN MR. RALPH MIGUEL LIM NATURE, AND ANY OTHER ENGINEERING STRUCTURES MENTIONED IN SECTION
REV. 0 23-MAY-23 ISSUED FOR APPROVAL
GENERAL MANAGER PRESIDENT
TWO OF THIS ACT UNLESS THE DESIGNS, PLANS, AND SPECIFICATIONS OF
SAME HAVE BEEN PREPARED UNDER THE RESPONSIBLE CHARGE OF, AND 2 2
DATE REG'D.:
SAND FILTER) AT WTP MALINGIN SIGNED AND SEALED BY A REGISTERED CIVIL ENGINEER, AND UNLESS THE
CONSTRUCTION, RECONSTRUCTION AND/OR ALTERATION THEREOF ARE
EXECUTED UNDER THE RESPONSIBLE CHARGE AND DIRECT SUPERVISION OF A
PRC.REG.NO.
CIVIL ENGINEER. PLANS AND DESIGNS OF STRUCTURES MUST BE APPROVED DRAWING NUMBER
AS PROVIDED BY LAW OR ORDINANCE OF A CITY OR PROVINCE OR
PTR NO. ISSUED ON: MUNICIPALITY WHERE THE SAID STRUCTURE IS TO BE CONSTRUCTED. WTPM-RSF-ED-002

RICHLI WATER ISSUED AT: TIN. : LOCATION: BRGY. PATROCINIO, CORTES, BOHOL ADDRESS: B. AQUINO ST., COGON, TAGBILARAN CITY, BOHOL ADDRESS: B. AQUINO ST., COGON, TAGBILARAN CITY, BOHOL
A B C

20.00

4.00 4.00 3.00 3.00 3.00 3.00

2.50 2.50
1.25
1.25 1.25 1.25

1.30

1.30

1.30

1.30
1 1

RSF RSF RSF

3.60

3.60
+2.70 ON FFL RSF

6.60

6.60
2 2

3.00

3.00
3 33

4.00 4.00 3.00 3.00 3.00 3.00

20.00

A B C

A-3 REFLECTED CEILING PLAN


3 3 SCALE 1 : 100 MTS

STEEL RAILINGS G.I BOX TYPE

SEE RAFTER DETAIL


STEEL RAILINGS
CHB PLASTERED FINISH WALL

A B C 3 2 1

APEX LINE APEX LINE APEX LINE APEX LINE


0.55

0.55
TOP OF BEAM SEE TRUSS DETAILS TOP OF BEAM TOP OF BEAM SEE TRUSS DETAILS TOP OF BEAM

CEILING LINE CEILING LINE CEILING LINE CEILING LINE


0.25

0.25
2.70

2.70
FINISH FLOOR LINE FINISH FLOOR LINE FINISH FLOOR LINE FINISH FLOOR LINE
7.80

7.80
BEAM LINE BEAM LINE BEAM LINE BEAM LINE
0.30

0.30
3.70

3.70
RSF RSF RSF RSF RSF
TOP OF SLAB TOP OF SLAB TOP OF SLAB TOP OF SLAB

NATURAL GROUND LINE NATURAL GROUND LINE NATURAL GROUND LINE NATURAL GROUND LINE
0.30

0.30
A-3 SECTION THRU A-A A-3 SECTION THRU B-B
3 3 SCALE 1 : 100 MTS 3 3 SCALE 1 : 100 MTS

FROM THE OFFICE OF: C I V I L E N G I N E E R : TITLE OF PROJECT : CHECKED BY : APPROVED AS TO PLAN & LOCATION : R.A. 5 4 4 , A R T I C L E I I I , S E C T I O N 1 9 : REVISIONS: SHEET CONTENTS SHEET NUMBER
IT SHALL BE UNLAWFUL FOR ANY PERSON TO ORDER OR OTHERWISE CAUSE
THE CONSTRUCTION, RECONSTRUCTION, OR ALTERATION OF ANY BUILDING
NO. DATE DESCRIPTION
OR STRUCTURE INTENDED FOR PUBLIC GATHERING OR ASSEMBLY SUCH AS
PROPOSED ADDITIONAL RSF THEATERS, CINEMATOGRAPHS, STADIA, CHURCHES OR STRUCTURES OF LIKE A-3
ENGR. ALFREDO T. CALINAWAN MR. RALPH MIGUEL LIM NATURE, AND ANY OTHER ENGINEERING STRUCTURES MENTIONED IN SECTION
REV. 0 23-MAY-23 ISSUED FOR APPROVAL
TWO OF THIS ACT UNLESS THE DESIGNS, PLANS, AND SPECIFICATIONS OF
3 3
(RAPID SAND FILTER) AT WTP GENERAL MANAGER PRESIDENT SAME HAVE BEEN PREPARED UNDER THE RESPONSIBLE CHARGE OF, AND
SIGNED AND SEALED BY A REGISTERED CIVIL ENGINEER, AND UNLESS THE
CONSTRUCTION, RECONSTRUCTION AND/OR ALTERATION THEREOF ARE
PRC.REG.NO. DATE REG'D.: MALINGIN EXECUTED UNDER THE RESPONSIBLE CHARGE AND DIRECT SUPERVISION OF A
CIVIL ENGINEER. PLANS AND DESIGNS OF STRUCTURES MUST BE APPROVED DRAWING NUMBER
AS PROVIDED BY LAW OR ORDINANCE OF A CITY OR PROVINCE OR
PTR NO. ISSUED ON: MUNICIPALITY WHERE THE SAID STRUCTURE IS TO BE CONSTRUCTED. WTPM-RSF-ED-002

RICHLI WATER ISSUED AT: TIN. : LOCATION: BRGY. PATROCINIO, CORTES, BOHOL ADDRESS: B. AQUINO ST., COGON, TAGBILARAN CITY, BOHOL ADDRESS: B. AQUINO ST., COGON, TAGBILARAN CITY, BOHOL
A B C D E F G A B B

20.00
8.00
4.00 4.00 3.00 3.00 3.00 3.00
4.00 4.00
2.50 2.50
1.25 1.25 1.25 1.25

C1F1 C1F1 1 1

1.30

1.30

1.30

1.30
RB1 RB1

1 1

RB1
RB1

RB1
3.60

3.60
3.60

3.60
ON FILL +25 ON FILL +25 ON FILL +25 ON FILL +25 ON FILL +25
ON FILL +25

6.60

6.60
RB1 RB1
2 2
6.60

6.60
C1F1
2 2

RB1

RB1
C1F1

3.00

3.00
ON FILL +25
3.00

3.00
RB1
3 3

3 3
S-1 ROOF BEAM
C1F1 C1F1 4.00 4.00 SCALE 1 : 100 MTS
1 1
4.00 4.00 3.00 3.00 3.00 3.00 8.00

20.00
A B B

A B C D E F G

A B B
S-1 FOUNDATION PLAN
1 1 SCALE 1 : 100 MTS 8.00

4.00 4.00

SCHEDULE OF BEAM
DIMENSION REINFORCEMENTS
1 FB1 FB1 1
AT AT AT AT
BEAM SUPPORT MID GAUGE STIRRUPS
DEPTH WIDTH SUPPORT MIDSPAN
(d) (b) TOP BOT TOP BOT

FB1

FB1

FB1
3.60

3.60
SLAB SLAB

3 - 12 3 - 12 3 - 12 3 - 12
10 MM. Ø
0.30 M. 0.20 M. MM Ø MM Ø MM Ø MM Ø GRADE 60 @5 - 0.05 M. ,

6.60

6.60
TB1 (300 MM.) (200 MM.) REBARS
@5 - 0.10 M. , FB1 FB1
(414 Mpa)
REST 0.14M.
2 2
TOP BOT TOP BOT

FB1

FB1
SLAB

3.00

3.00
3 - 12 3 - 12 3 - 12 3 - 12
10 MM. Ø
0.30 M. 0.20 M. MM Ø MM Ø MM Ø MM Ø GRADE 60 @5 - 0.05 M. ,
RB1 (300 MM.) (300 MM.) REBARS
@5 - 0.10 M. ,
(414 Mpa)
REST 0.14M. 3 FB1
3

4.00 4.00
S-1 FLOOR FRAMING PLAN
1 1 SCALE 1 : 100 MTS
BOT. BARS TOP BARS BOT. BARS
CUT BARS 8.00
CUT BARS CUT BARS
10mm STIRRUPS
TOP BARS TOP BARS
A B B
D

D SLAB DETAILS
THICKNESS
REBARS DIAMETER (mm) SPACING (mm) TYPE
(mm)
B B
CUT BARS CONTINUOUS
BOT. BARS BOTTOM BARS 10 200 TWO-WAY 125
@ MIDSPAN L/5 L/5 @ SUPPORT
TEMPERATURE
L/4 L/4 10 400 ONE-WAY 125
BARS
LENGTH (L)
CUT BARS 10 200

S-1 TYPICAL BEAM DETAILS BEND BARS 10 200


1 1 SCALE 1 : 100 MTS

FROM THE OFFICE OF: CIVIL ENGINEER: TITLE OF PROJECT : CHECKED BY : R.A. 5 4 4 , A R T I C L E I I I , S E C T I O N 1 9 : REVISIONS: SHEET CONTENTS SHEET NUMBER
IT SHALL BE UNLAWFUL FOR ANY PERSON TO ORDER OR OTHERWISE CAUSE
THE CONSTRUCTION, RECONSTRUCTION, OR ALTERATION OF ANY BUILDING
NO. DATE DESCRIPTION
OR STRUCTURE INTENDED FOR PUBLIC GATHERING OR ASSEMBLY SUCH AS
PROPOSED ADDITIONAL RSF THEATERS, CINEMATOGRAPHS, STADIA, CHURCHES OR STRUCTURES OF LIKE S-1
ENGR. ALFREDO T. CALINAWAN MR. RALPH MIGUEL LIM NATURE, AND ANY OTHER ENGINEERING STRUCTURES MENTIONED IN SECTION
REV. 0 23-MAY-23 ISSUED FOR APPROVAL
TWO OF THIS ACT UNLESS THE DESIGNS, PLANS, AND SPECIFICATIONS OF
1 1
(RAPID SAND FILTER) AT WTP GENERAL MANAGER PRESIDENT SAME HAVE BEEN PREPARED UNDER THE RESPONSIBLE CHARGE OF, AND
SIGNED AND SEALED BY A REGISTERED CIVIL ENGINEER, AND UNLESS THE
CONSTRUCTION, RECONSTRUCTION AND/OR ALTERATION THEREOF ARE
PRC.REG.NO. DATE REG'D.: MALINGIN EXECUTED UNDER THE RESPONSIBLE CHARGE AND DIRECT SUPERVISION OF A
CIVIL ENGINEER. PLANS AND DESIGNS OF STRUCTURES MUST BE APPROVED DRAWING NUMBER
AS PROVIDED BY LAW OR ORDINANCE OF A CITY OR PROVINCE OR
PTR NO. ISSUED ON: MUNICIPALITY WHERE THE SAID STRUCTURE IS TO BE CONSTRUCTED. WTPM-RSF-ED-002

RICHLI WATER ISSUED AT: TIN. : LOCATION: BRGY. PATROCINIO, CORTES, BOHOL ADDRESS: B. AQUINO ST., COGON, TAGBILARAN CITY, BOHOL ADDRESS: B. AQUINO ST., COGON, TAGBILARAN CITY, BOHOL
ELECTRICAL NOTES :

¨ ALL ELECTRICAL WORKS AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE LATEST EDITION OF THE PHILIPPINE
7W 7W 7W
ELECTRICAL CODE AND THE RULES AND REGULATIONS OF THE NATIONAL AND LOCAL AUTHORITIES CONCERNED IN THE ENFORCEMENT
RSF RSF RSF
OF ELECTRICAL LAWS AND REGULATIONS OF THE UTILITY COMPANIES CONCERNED.
RSF
¨ ALL INSTALLATION SHALL BE CONCEALED FROM VIEW, WIRING SHALL BE INCASE IN POLYVINYL CHLORIDE (PIPE) SCHED. 40
7W

7W 7W
EXCEPT POWER AND TELEPHONE SERVICE WHICH SHALL BE RIGID STEEL CONDUIT (RSC) OTHERWISE NOTED.
¨ MINIMUM WIRE AND CONDUIT SIZE SHALL BE #14awg type THHN (2.0mm^2) AND 4 3" Ø (20mm Ø) PVC TRADE SIZE
RESPECTIVELY, UNLESS OTHERWISE SPECIFIED.
¨ PULL BOXES OF APPROPRIATE SIZE SHALL BE PROVIDED, EVEN IF NOT INDICATED IN THE DRAWINGS TO ACCOMMODATE THE
C1
7W 7W
NUMBER OF SPLICES OF WIRE.
¨ ALL MATERIALS TO BE USE SHALL BE NEW AND APPROVE TYPE APPROPRIATE FOR BOTH LOCATION AND INTENDED USE.
A-1 LIGHTING LAYOUT PLAN ¨ LIGHT CONTROL SWITCHES SHALL BE RATED 10amps, 300watts AND SHALL NOT CARRY A LOAD GREATER THAN 50amps.
1 1 SCALE 1 : 100 MTS ¨ DUPLEX RECEPTACLES SHALL BE RATED 10amps, 250volts, ROUNDED SLOTS FOR 220volts AND PARALLEL SLOTS FOR 110volts.
SPECIAL OUTLETS SHALL BE RATED 15amps, 250volts AS REQUIRED.
¨ FOR EACH SPARE CIRCUIT IN THE PANEL BOARD, PROVIDE EMPTY 34" Ø RISER TERMINATING IN A 2-18" DEEP BY 4" OCTAGONAL BOX
ABOVE CEILING.
¨ ALL WIRING SHALL BE INSTALLED AS INDICATED IN THE MOUNTING OF HEIGHTS UNLESS OTHERWISE SPECIFIED :
LIGHT SWITCHES ....................................1.40mts FROM FLOOR LINE
CONVENIENCE OUTLETS ...................... 0.30mts FROM FLOOR LINE & COUNTER TOPS.
PANEL BOARD .........................................1.60mts FROM FLOOR LINE
EMERGENCY LIGHT OUTLET..................0.15mts FROM CEILING LINE

¨ ELECTRICAL INSTALLATIONS SHALL BE UNDER THE DIRECT SUPERVISION OF A DULY LICENSED ELECTRICAL ENGINEER .
RSF RSF RSF RSF
¨ NO REVISION IN THE DESIGN SHALL BE DONE WITHOUT THE PRIOR KNOWLEDGE AND APPROVAL OF THE DESIGNER AND THE
C1
OWNER,
¨ ANY SUCH REVISION DONE WITHOUT APPROVAL SHALL CAUSE THE RESPONSIBILITY OF THE DESIGNER TO CEASE AS A WHOLE.
PANEL BOARD

S C H E D U L E O F L O A D S
A-1 CONVENIENCE LAYOUT PLAN
1 1 SCALE 1 : 100 MTS SWITCHES OCPD (MCB) WIRE SIZE
CIRCUIT LOAD DESCRIPTION CONV./OTHER LIGHTNING VOLTS LOAD (w) AMPS CONDUIT USE
NO. OUTLETS OUTLETS S1 S2 S3 S23WS AT AF HOT WIRE GROUNDING WIRE
1 LIGHTING OUTLET 9 230 900 3.91 15 50 2 - 3.5 mm² THHN CU. WIRE 1 - 3.5 mm² THHN CU. WIRE 20mm Ø PVC PIPE
2 CONVENIENCE OUTLET 4 230 800 3.48 20 50 2 - 5.5 mm² THHN CU. WIRE 1 - 5.5 mm² THHN CU. WIRE 25mm Ø PVC PIPE
25mm Ø PVC Pipe
3 ACU 230 1500 6.52 20 50 2 - 5.5 mm² THHN CU. WIRE 1 - 5.5 mm² THHN CU. WIRE 25mm Ø PVC PIPE
FROM M SPARE
POWER SOURCE
4 230 20 50 2 - 5.5 mm² THHN CU. WIRE 1 - 5.5 mm² THHN CU. WIRE 25mm Ø PVC PIPE
5 MAIN 6 15 230 3200 13.91 40 50 2 - 5.5 mm² THHN CU. WIRE 1 - 5.5 mm² THHN CU. WIRE 25mm Ø PVC PIPE
COMPUTATION FOR FEEDER MAIN BREAKER AND WIRE SIZE
DISCONNECT: 20 AT/100 AF, 2-POLE,
10 KAIC, 230 V, CB BOLT-ON, LOAD CONNECTED DEMAND POWER FEEDER MAIN BREAKER:
NEMA 3R SINGLE SECONDARY DESCRIPTION LOAD (VA) FACTOR (VA)
ROCK W/ SPOOL
OCPD = EQUIVALENT CURRENT + 150% OF THE LARGEST
L.O, C.O, S.A 12640 1st 3KVA,100% 6374 MOTOR
INSULATOR Remainder, 35% OCPD = 80.46 AMPS
0.15m USE: 80AT/100AF, 220V, 2-POLE, 1-PHASE, 60Hz BOLT-ON TYPE CB
RANGE 3000 80% 2400

40AT main ENTRANCE CAP W/ ACU 6601 80% 5280.8 FEEDER WIRE SIZE:
22mm2 THW cu. WIRE
2-P, 230V 32mm Ø ADAPTOR IC = EQUIVALENT CURRENT + 25% OF THE LARGEST MOTOR
OTHERS 1000 100% 1000
IC = 67.96 AMPS
15AT 15AT TOTAL 15054.8 USE: 2 - 22 mm2 THW WIRE IN 32MM Ø PVC PIPE
1 - 8.0 mm2 TW WIRE FOR GROUNDING IN 20MM Ø PVC PIPE
CONVENIENCE OUTLET 32mm Ø PVC PIPE
LIGHTING OUTLET C1 C2
20AT 20AT
ACU C3 C4 SPARE 32mm PVC CLIP

LEGEND & SYMBOLS:

5.5m
METER BOX METER BOX
- STRIP TYPE PINLIGHT - RANGE OUTLET
RANGE

NEMA 3R NEMA 3R
Grounding Bus ar
- SINGLE GANG, ONE WAY SWITCH
- CHANDELIER
1.7m

1.7m
1.4m

1.4m
- DOUBLE GANG, ONE WAY SWITCH
25mm Ø PVC PIPE 0.25m
- PENDANT LIGHT - THREE GANG, ONE WAY SWITCH
- SURFACE TYPE PINLIGHT
GROUNDING ELECTRODE - TWO GANG, THREE WAY SWITCH
3/8"X8' GROUNDING ROD - RECESSED TYPE PINLIGHT
- CIRCUIT LINE
SIDE ELEVATION - WALL LAMP
FRONT ELEVATION - CIRCUIT HOMERUN
- ACU
- CATV - PANEL BOARD
E-1 MAIN DISTRIBUTION PANEL AND GROUNDING
6 9 SCALE 1 : 100 MTS E-1 RECEIVING POLE DETAILS -CONVENIENCE OUTLET - EMERGENCY LIGHT
6 9 SCALE 1 : 100 MTS

F ROM T HE OF FI CE O F: C I V I L E N G I N E E R : TITLE OF PROJECT : CHECKED BY : APPROVED AS TO PLAN & LOCATION : R.A. 5 4 4 , A R T I C L E I I I , S E C T I O N 1 9 : REVISIONS: SHEET CONTENTS SHEET NUMBER
IT SHALL BE UNLAWFUL FOR ANY PERSON TO ORDER OR OTHERWISE CAUSE
THE CONSTRUCTION, RECONSTRUCTION, OR ALTERATION OF ANY BUILDING NO. DATE DESCRIPTION
OR STRUCTURE INTENDED FOR PUBLIC GATHERING OR ASSEMBLY SUCH AS
PROPOSED ADDITIONAL RSF ENGR. ALFREDO T. CALINAWAN MR. RALPH MIGUEL LIM
THEATERS, CINEMATOGRAPHS, STADIA, CHURCHES OR STRUCTURES OF LIKE
NATURE, AND ANY OTHER ENGINEERING STRUCTURES MENTIONED IN SECTION
REV. 0 23-MAY-23 ISSUED FOR APPROVAL
E-1
TWO OF THIS ACT UNLESS THE DESIGNS, PLANS, AND SPECIFICATIONS OF
1 1
(RAPID SAND FILTER) AT WTP GENERAL MANAGER PRESIDENT SAME HAVE BEEN PREPARED UNDER THE RESPONSIBLE CHARGE OF, AND
SIGNED AND SEALED BY A REGISTERED CIVIL ENGINEER, AND UNLESS THE
CONSTRUCTION, RECONSTRUCTION AND/OR ALTERATION THEREOF ARE
PRC.REG.NO. DATE REG'D.: MALINGIN EXECUTED UNDER THE RESPONSIBLE CHARGE AND DIRECT SUPERVISION OF A
CIVIL ENGINEER. PLANS AND DESIGNS OF STRUCTURES MUST BE APPROVED DRAWING NUMBER
AS PROVIDED BY LAW OR ORDINANCE OF A CITY OR PROVINCE OR
PTR NO. ISSUED ON: MUNICIPALITY WHERE THE SAID STRUCTURE IS TO BE CONSTRUCTED. WTPM-RSF-ED-002

RICHLI WATER ISSUED AT: TIN. : LOCATION: BRGY. PATROCINIO, CORTES, BOHOL ADDRESS: B. AQUINO ST., COGON, TAGBILARAN CITY, BOHOL ADDRESS: B. AQUINO ST., COGON, TAGBILARAN CITY, BOHOL