You are on page 1of 1

NOTES

DRAWINGS AND ACCOMPANYING SPECIFICATIONS AS


INSTRUMENTS OF SERVICE, ARE THE EXCLUSIVE
PROPERTY OF TALATI & PANTHAKY-ASSOCIATED PVT.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 LTD. AND THEIR USE AND PUBLICATIONS SHALL BE
RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY
WERE PREPARED.

RE-USE, REPRODUCTIONS OR PUBLICATION BY ANY


METHOD IN WHOLE OR PART IS PROHIBITED EXCEPT BY
WRITTEN PERMISSION FROM THE ARCHITECT. TITLE TO
THESE PLANS & SPECIFICATIONS SHALL REMAIN WITH
THE ARCHITECT WITHOUT PREJUDICE AND VISUAL
OHT TOP CONTACT WITH THEM SHALL CONSTITUTE PRIMA FACIE
EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS.
+51300
CONTRACTORS MUST VERIFY DIMENSIONS ON THE JOB
AND REPORT DISCREPANCIES IF ANY IN WRITING, TO THE
ARCHITECT'S OFFICE.

DRAWINGS NOT TO BE SCALED, WRITTEN DIMENSIONS


TO BE FOLLOWED.

OHT BOTTOM FOR STRUCTURAL DETAILS REFER R.C.C CONSULTANTS


DRAWINGS.
+48600
FOR SERVICES DETAILS REFER M.E.P. CONSULTANTS
DRAWINGS.
DRAWING NOTES:
1) CERTAIN CUT-OUTS,SLEEVE DETAILS, DUCT DETAILS AND
OPENINGS SHALL BE FINALIZED ONLY ONCE THE FINAL
MEP/CFO LAYOUTS ARE RECEIVED FROM THE RESPECTIVE
CONSULTANT
TERRACE
1. DO NOT SCALE FROM THE DRAWINGS.
+45600 2. ALL DIMENSIONS ARE IN MM UNLESS NOTED OTHERWISE.
3. ALL LEVELS ARE IN METERS, INDICATING 'TOP OF
CONCRETE' (TOC) WHEREEVER APPLICABLE.
4. ALL DIMENSIONS TO BE CONFIRMED AT SITE AND
APPROVED BY THE ENGINEER
5. THIS DRAWING SHOULD BE READ IN CONJUNCTION
WITH OTHER RELEVANT CONSULTANTS' DRAWINGS
AND CHECKED BEFORE EXECUTION.
6. PROPOSED CONCEPTUAL DRAWING UNLESS OTHERWISE
SPECIFIED.
7. THE DRAWING SHOULD BE CHECKED BY THE MUNICIPAL
ELEVENTH FLOOR ARCHITECT IN CONJUNCTION WITH THE APPROVED
SANCTIONED DRAWINGS BEFORE EXECUTION ON SITE.
+42175
8. FOR RCC AND COLUMN SIZES/CONSTRUCTION, KINDLY
REFER TO THE BEAM AND COLUMN SIZES AND RCC
DETAILS FROM THE STRUCTURAL CONSULTANT.

KEY PLAN N

TENTH FLOOR
+38750

NINTH FLOOR
+35325

EIGHT FLOOR
+31900

REV PURPOSE OF ISSUE DATE AUTHORIZED

SEVENTH FLOOR
+28475
FOR REVIEW

ARCHITECT :

TALATI AND PANTHAKY


SIXTH FLOOR
+25050
ASSOCIATED DESIGNERS LLP

CLIENT :

ARMAAN
INFRASTRUCTURE
FIFTH FLOOR
+21625
ASSOCIATE ARCHITECT :

SCARLETT DESIGNS PVT.LTD


AHMEDABAD
STRUCTURE CONSULTANT :
FOURTH FLOOR
+18200

A3-A4, 3rd FLOOR, Safal profitaire, Corporate road,


Nr prahladnagar Garden, S.G.ROAD, Ahm'd-51.
E-mail: contact@duconconsultants.in
PH:40073196,65410630,65410631

THIRD FLOOR
HVAC SERVICES CONSULTANT :
+14775

B-402, Fairdeal House, Near Swastik Cross Roads, Off C.G.Road,


Navarangpura, Ahmedabad-380 009
BSNL : +91-79-26 405 405
email : anjaria@anjariaassociates.com | www.anjariaassociates.com

SECOND FLOOR ELECTRICAL SERVICES CONSULTANT :

+11350 Antech Consultants &


Engineers
403, Satkar, B/h. Swagat, Off. C.G. Road, Navrangpura, Ahmedabad : 380 009
Telefax : +91 79 2656 1881, 4893 4849

BIM, PLUMBING & FIRE CONSULTANT :

FIRST FLOOR
+7925

PROJECT :

THE WATERFALL

MEZZANINE FLOOR PROJECT NO : AEPL BIM_0058


+4125
DRAWING TITLE :

REAR SIDE ELEVATION

PLINTH LEVEL
+600
Original Scale Drawn: Checked: Authorised: Size.
GROUND FLOOR AASHIR
AS Date : Date : Date : A1
+0 SHOWN Designer Designer Designer
Drawing Number Rev.
REAR SIDE ELEVATION
1 1 : 100
A701 Author

11/12/2021 9:44:04 AM