You are on page 1of 1

NOTES

X1 X2 A B X3 C D E F G H J K L M N P Q R X4 X5 DRAWINGS AND ACCOMPANYING SPECIFICATIONS AS


INSTRUMENTS OF SERVICE, ARE THE EXCLUSIVE
PROPERTY OF TALATI & PANTHAKY-ASSOCIATED PVT.
LTD. AND THEIR USE AND PUBLICATIONS SHALL BE
RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY
WERE PREPARED.

RE-USE, REPRODUCTIONS OR PUBLICATION BY ANY


OHT TOP METHOD IN WHOLE OR PART IS PROHIBITED EXCEPT BY
WRITTEN PERMISSION FROM THE ARCHITECT. TITLE TO
+51300 THESE PLANS & SPECIFICATIONS SHALL REMAIN WITH
THE ARCHITECT WITHOUT PREJUDICE AND VISUAL
CONTACT WITH THEM SHALL CONSTITUTE PRIMA FACIE
EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS.

CONTRACTORS MUST VERIFY DIMENSIONS ON THE JOB


AND REPORT DISCREPANCIES IF ANY IN WRITING, TO THE
ARCHITECT'S OFFICE.
OHT BOTTOM
DRAWINGS NOT TO BE SCALED, WRITTEN DIMENSIONS
+48600
TO BE FOLLOWED.

FOR STRUCTURAL DETAILS REFER R.C.C CONSULTANTS


DRAWINGS.

FOR SERVICES DETAILS REFER M.E.P. CONSULTANTS


DRAWINGS.
DRAWING NOTES:
TERRACE
1) CERTAIN CUT-OUTS,SLEEVE DETAILS, DUCT DETAILS AND
+45600 OPENINGS SHALL BE FINALIZED ONLY ONCE THE FINAL
MEP/CFO LAYOUTS ARE RECEIVED FROM THE RESPECTIVE
CONSULTANT
1. DO NOT SCALE FROM THE DRAWINGS.
2. ALL DIMENSIONS ARE IN MM UNLESS NOTED OTHERWISE.
3. ALL LEVELS ARE IN METERS, INDICATING 'TOP OF
CONCRETE' (TOC) WHEREEVER APPLICABLE.
4. ALL DIMENSIONS TO BE CONFIRMED AT SITE AND
APPROVED BY THE ENGINEER
5. THIS DRAWING SHOULD BE READ IN CONJUNCTION
ELEVENTH FLOOR WITH OTHER RELEVANT CONSULTANTS' DRAWINGS
AND CHECKED BEFORE EXECUTION.
+42175 6. PROPOSED CONCEPTUAL DRAWING UNLESS OTHERWISE
SPECIFIED.
7. THE DRAWING SHOULD BE CHECKED BY THE MUNICIPAL
ARCHITECT IN CONJUNCTION WITH THE APPROVED
SANCTIONED DRAWINGS BEFORE EXECUTION ON SITE.
8. FOR RCC AND COLUMN SIZES/CONSTRUCTION, KINDLY
REFER TO THE BEAM AND COLUMN SIZES AND RCC
DETAILS FROM THE STRUCTURAL CONSULTANT.

KEY PLAN N
TENTH FLOOR
+38750

NINTH FLOOR
+35325

EIGHT FLOOR
+31900

SEVENTH FLOOR
+28475 REV PURPOSE OF ISSUE DATE AUTHORIZED

FOR REVIEW

SIXTH FLOOR ARCHITECT :

+25050
TALATI AND PANTHAKY
ASSOCIATED DESIGNERS LLP

CLIENT :

FIFTH FLOOR ARMAAN


+21625
INFRASTRUCTURE

ASSOCIATE ARCHITECT :

SCARLETT DESIGNS PVT.LTD


FOURTH FLOOR AHMEDABAD
+18200
STRUCTURE CONSULTANT :

A3-A4, 3rd FLOOR, Safal profitaire, Corporate road,


THIRD FLOOR Nr prahladnagar Garden, S.G.ROAD, Ahm'd-51.
E-mail: contact@duconconsultants.in
+14775 PH:40073196,65410630,65410631

HVAC SERVICES CONSULTANT :

B-402, Fairdeal House, Near Swastik Cross Roads, Off C.G.Road,


SECOND FLOOR Navarangpura, Ahmedabad-380 009
BSNL : +91-79-26 405 405
email : anjaria@anjariaassociates.com | www.anjariaassociates.com
+11350
ELECTRICAL SERVICES CONSULTANT :

Antech Consultants &


Engineers
403, Satkar, B/h. Swagat, Off. C.G. Road, Navrangpura, Ahmedabad : 380 009
Telefax : +91 79 2656 1881, 4893 4849
FIRST FLOOR
BIM, PLUMBING & FIRE CONSULTANT :
+7925

PROJECT :

MEZZANINE FLOOR
THE WATERFALL
+4125

PROJECT NO : AEPL BIM_0058


DRAWING TITLE :

RIGHT SIDE ELEVATION


PLINTH LEVEL
+600

GROUND FLOOR
+0
Original Scale Drawn: Checked: Authorised: Size.
AASHIR
RIGHT SIDE ELEVATION AS Date : Date : Date : A1
1 1 : 100
SHOWN Designer Designer Designer
Drawing Number Rev.

A703 Author

11/12/2021 9:48:00 AM