Operation Manual: HSU-12HQA03/R2 (DB)
Operation Manual: HSU-12HQA03/R2 (DB)
HSU-12HQA03/R2(DB)
Please read this operation manual before using the air conditioner
0010538206
Contents
1
Parts and Functions
Indoor Unit Remote controller
9. ON/OFF button
Air Purifying 10. TIMER ON display
Inlet Filter Anion 19 11. FAN SPEED display
generator
Inlet (inside) LOW MED HI AUTO
grille 12. LOCK display
Vertical blade 13. SWING display
(adjust left and
14. SLEEP display
Nano-Aquo right air fl ow) 15. HEALTH display
Generator Outlet 16. Operation mode display
(inside) Horizontal flap
(adjust up and down air flow 28 Operation mode AUTO COOL DRY HEAT FAN
2
Operation
Base Operation Emergency operation and test operation
Emergency Operation:
Use this operation only when the remote controller
Remote controller is defective or lost.
When the emergency operation switch is
1 4 pressed,the" Pi "sound is heard once, which emergency
operation
P
i
2 the operation modes,cooling or fan or heat,
according to the room. temperature.
Room Operation Designated Timer Air flow
temperature mode temperature mode
ABOVE 24OC COOLING 24OC NO AUTOMATIC
1. Unit start BELOW 24 C
O HEAT 24 C
O NO AUTOMATIC
Press ON/OFF on the remote controller, unit starts.
(Cooling only uint) Operation Designated Timer
2.Select operation mode Room temperature mode temperature mode Air flow
Press MODE button. For each press, operation mode
O O
BELOW 24 C FAN 24 C NO AUTOMATIC
changes as follows: It is not possible to operate in dry mode.
Remote controller:
Test operation:
AUTO COOL DRY FAN HEAT Test operation switch is the same as emergency switch.
Use this switch in the test operation when the room
3.Select temp.setting o
temperature is below 16 C, do not use it in the
Press / button normal operation.
Every time the button is pressed, temp.setting Continue to press the test operation
o
increase 1 C,if kept depressed, it will increase switch for more than 5 seconds . After
rapidly you hear the "Pi" sound twice, release
test operation
switch
Every time the button is pressed, temp.setting your finger from the switch: the cooling
Pi
Pi
decrease 1oC,if kept depressed, it will operation starts with the air flow speed "Hi".
decrease rapidly
Select a desired temperature.
Air Flow Direction Adjustment
4.Fan speed selection
Press FAN button. For each press, fan speed 1.Status display of air flow
changes as follows: Vertical flap
Remote controller: Pos.1 Pos.2 Pos.3
Pos.4 Pos.5 Pos.6 (Auto swing)
LOW MED HI AUTO
Air conditioner is running under displayed fan speed. 2.Left and right air flow adjustment
When FAN is set to AUTO, the air conditioner For each press of button, remote controller
automatically adjusts the fan speed according to room displays as follows :
temperature. remote controller:
Pos.1 Pos.2 Pos.3 Pos.4
Operation Remote
Mode Controller Note
Pos.5 Pos.6 Pos.7 Pos.8
Under the mode of auto operation, air conditioner
will automatically select Cool or Heat operation
AUTO according to room temperature. When FAN is set
to AUTO, the air conditioner automatically adjusts
the fan speed according to room temperature.
Cautions:
COOL
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur
In DRY mode, when room temperature becomes
lower than temp.setting+2 oC, unit will run
at air outlet if all vertical louvers are adjusted to left or
DRY intermittently at LOW speed regardless of FAN right.
setting.
1 hr Rises 1 C
O
You can use this function when silence is needed for
rest or reading. In SOFT operation mode, fan speed
1 hr
Rises 1OC automatically takes low speed of AUTO fan mode.
5
Maintenance
For Smart Use of The Air Conditioner
Setting of proper room Do not block the air inlet Remote Controller Indoor Body
temperature or outlet
NOTE:
Detach old Air Purifying Filter
The photocatalyst air purifying filter will be solarized in fixed
time. In normal family, it will be solarized every 6 months.
6
Cautions
WARNING
Please call Sales/Service Shop for the Installation.
Do not attempt to install the air conditioner by yourself because improper works
may cause electric shock, fire, water leakage.
WARNING
When abnormality such as burnt-small found, Use an exclusive Check proper
immediately stop the operation button and power source installation of the
contact sales shop. with a circuit drainage securely
breaker
Do not start or stop the Do not channel the air flow directly Do not try to repair or Connect the earth
operation by disconnecting at people, especially at infants or reconstruct by yourself.
the aged. cable.
the power supply cord
and so on.
earthing
PROHIBITION PROHIBITION
CAUTION
Do not use for the purpose of storage of Take fresh air occasionally especially Do not operate the switch with
food, art work, precise equipment, when gas appliance is running at the wet hand.
breeding, or cultivation. same time.
STRICT
PROHIBITION ENFORCEMENT PROHIBITION
Do not install the unit near a fireplace Check good condition of the Do not pour water onto the unit
or other heating apparatus. installation stand for cleaning
7
Trouble shooting Cautions
Before asking for service, check the following
Do not obstruct or cover the ventilation grille of the air
first. conditoner.Do not put fingers or any other things into the
inlet/outlet and swing louver.
Phenomenon Cause or check points Do not allow children to play with the air conditioner.In no
case should children be allowed to sit on the outdoor unit.
The system When unit is stopped, it won't restart
does not restart immediately until 3 minutes have Specifications
immediately. elapsed to protect the system.
When the electric plug is pulled out The refrigerating circuit is leak-proof.
and reinserted, the protection circuit
will work for 3 minutes to protect the The machine is adaptive in following situation
air conditioner. 1.Applicable ambient temperature range:
During unit operation or at stop,
a swishing or gurgling noise may Maximum:D.B/W.B 32oC/23oC
Noise is heard be heard.At first 2-3 minutes after Indoor Minimum:D.B/W.B 21oC/15oC
unit start, this noise is more noticeable. Cooling
(This noise is generated by Maximum:D.B/W.B 43oC/26oC
refrigerant flowing in the system.)
Outdoor Minimum: D.B 18oC
During unit operation, a cracking Maximum:D.B 27oC
noise may be heard.This noise is Indoor Minimum: D.B 0 oC
generated by the casing expanding
Normal or shrinking because of Heating
Maximum:D.B/W.B 24oC/18oC
Performance temperature changes. Outdoor
Minimum:D.B/W.B - 7 oC/-8oC
inspection Should there be a big noise from o o
air flow in unit operation, air Outdoor Maximum:D.B/W.B 24 C/18 C
filter may be too dirty. (INVERTER) Minimum:D.B -15oC
This is because the system
Smells are circulates smells from the interior 2. If the power supply cord is damaged, it must be replaced by the
generated. air such as the smell of furniture, manufacturer or its service agent or a similar qualified person.
paint, cigarettes.
3.If the fuse of indoor unit on PC board is broken,please change
Mist or steam are
blown out. During COOL or DRY operation, it with the type of T. 3.15A/ 250V. If the fuse of outdoor unit is
indoor unit may blow out mist. broken,change it with the type of T.25A/250V
This is due to the sudden cooling
of indoor air. 4. The wiring method should be in line with the local wiring standard.
8
Specifications
AIR-CONDITIONING
MODEL HSU-12HQA03/R2(DB)
Power(W) 990
BTU 12000
VOLTAGE@50Hz(Nominal) 220
Tropicalised YES
Electrostatics Fliter NO
9
Electrical Diagram
12k wiring diagram of split unit indoor
CN11
M LEFT STEP MOTOR
CN10
M RIGHT STEP MOTOR
M
CN32
,,
M RIGHT PANEL MOTOR
CN32
M UP-DOWN STEP MOTOR
CN9
INDOOR FAN MOTOR CN5
SW1
C0N1 BL
R
W
1(N) 2(L)
TO OUTDOOR UNIT
B
3(C)
Y/G BR BL
NOTES
B BLACK
Y/G R RED
BR BROWN
BL BLUE
W WHITE
NOTES:THE DOTTED PARTS ARE OPTIONAL. Power 1PH,220V~,50Hz Y/G YELLOW/GREEN
10
Electrical Diagram
12k wiring diagram of split unit indoor
MODULE BOARD
M WARNING
CN6 CAUTION
CN9 CN8 DON'T TOUCH CAPACITOR, EVEN AFTER
PLUG-OFF ( DANGER OF ELECTRIC SHOCK)
AC-N AC-L R W B The capacitor retains high
CN11 CN10 CN1 voltage even after the plug-off.
CN7 W V U For your safety, be sure to wait
CN5 CN4CN3CN2 at least 5 minutes. after plug
PFC REACTOR Y/G off and use a tester to confirm
the voltage between connector P
BL OR and N(on module board) is less
GND
M
CN2 CN24
CN3 CN23
1 2 3
DC FAN MOTOR
CN4
R
CN21
LED1 Flash
Description
M
Times
AC-N AC-L MAIN CONTROL BOARD Outdoor EEPROM error 1
CN8 CN9
The protection of IPM 2
Y/G CN10 Overcurrent protection
1A/250VAC 3
CN15CN14 CN13 of AC electricity
FUSE2
CN16 CN20 CN19 CN18 CN17 Communication fault
GND CN11 between the IPM and CBD
4
Over pressure or Overheat 5
protection for the compressor
Power voltage is too high or low 6
M
COMPRESSOR DISCHARGE
11
-
-
MINNA,ILORIN,OSHOGBO,LOKOJA, -
AKURE,SOKOTO,YOLA,MAKURDI,GUSAU,
sales office
7 2719790