You are on page 1of 11

STEEL CONNECTION DESIGN

Tedds calculation version 1.2.00

UKC 254x254x73
220 x 100
w/ 3No. x 8Bolts
M20 mm p
100 kN
35 kN

Beam A
(UKB 305x102x2

1.00
1.00
1.10
1.25
1.10

355
470
70
70
50
40

40
5050
70
70
50
40

40

100
35

355
470
0.9

220
100
8
10

355
470
0.9
3
1
3
40
50
40
70
22

900
1000

183.1
220

50
10
10
8.4
5.8
40
40

-65

50
0
0.36
245
0.5
98
200.6
0.499

2.5
0.61
2.5
0.76
91.15
113.94
207.62
0.482
2.5
0.81
2.5
0.61
88.39
66.08
151.74
0.659

1232
312
1000
284.04
303.92
271.61
271.61
0.368

50
50

64533
458.19
0.218

1835.4
1452.6
168.2
1015
376.18
358.33
358.33
0.279

8.0
5.6
4.8
0.857
1232
473.76

768
624
456.04

1000
312
491.22
456.04
0.077

0.5
245
111.36
334.09
0.105

0.758
2.5
129.48
388.43
0.090

893.2
343.48
556.8
336.4
306.85
306.85
0.114

0.606
2.5
75.1
225.29
0.155
UC 254x254x73
290 x 150
w/ 8No. x 10
M20 mm
Bolts
150 kN
75 kN

Beam
(UB A
457x191x82)

1.00
1.00
1.10
1.25
1.10

355
470
3030
40
70
70 40
70 70

150

355
470

290
150
0.9
75

10
40
50 70
70
40
50
275
410
0.85

4
8
40
30
70
90
22

640
800

276
290

50

10

90

8.0
4.8
5.6
0.85
253.17
411.15
83.85
0.204

2584
529.59
529.59
0.283
In accordance with EN1993-1-1:2005 incorporating Corrigenda February 2006 and April 2009, and
EN1993-1-8:2005 incorporating Corrigenda December 2005, September 2006 and July 2009, and the UK
National Annex.Beam to Column connection exampleConnection detailsConnection type; Fin
plateNumber of supported beams; 1 supported beamPartial factorsResistance of cross-
section; gM0 = Resistance of members to instability; gM1 =
Cross-sections in tension to fracture; gM2,c = Resistance of bolts; gM2,b = Structural
integrity; gM,u = Supporting column detailsSection name;
UKC 254x254x73Steel grade; S355Yield strength; fy = N/mm2Ultimate
strength; fu = N/mm2 Supported Beam ASummary
ResultsCheckDescriptionUnitsDesign ForceDesign ResistanceUtilisation1Recommended detailing
practicesPASS2Supported beam - Bolt groupkN100151.70.659PASS3Supported beam - Fin
platekN100271.60.368PASS4Supported beam - Web in shearkN100358.30.279PASS8Supported beam -
Weldsmm5.64.80.857PASS11Structural integrity - Plate and boltskN35334.10.105PASS12Structural
integrity - Beam webkN35225.30.155PASSDesign forcesDesign shear; VEd1 = kNDesign
tying force; FEd1 = kNSupported beam detailsSection name;
UKB 305x102x25Steel grade; S355Yield strength; fy,b = N/mm2Ultimate
strength; fu,b = N/mm2Correlation factor; bw,b = Fin plate
detailsPlate height; hp = mmPlate width; bp = mmPlate
thickness; tp = mmGap to plate; gh = mmPlate grade;
S355Yield strength; fy,p = N/mm2Ultimate strength; fu,p =
N/mm2Correlation factor; bw,p = Bolt detailsNumber of bolt rows; n1,1 =
Number of bolt lines; n2,1 = Total number of bolts; Nb,tot = Fin plate end
distance; e1 = mmFin plate edge distance;e2 = mmBeam edge
distance; e2,b = mmPitch; p1 = mmBolt hole;
d0 = mmBolt size; M20Bolt grade; 10.9Yield strength;
fy,bolt = N/mm2Ultimate strength; fu,bolt = N/mm2Check 1: Recommended detailing
practiceMin rec plate height; 0.6 ´ hb = mmActual plate height; hp = mmMax
rec depth to plate; 50 mmActual depth to plate; dp = mmMin rec gap
distance; 10 mm = mmActual gap distance; gh = mmMax
rec thickness for rotation; 0.42 ´ db = mmActual thickness; Min(tp, tw,b) = mmMin
rec edge distance; 2 ´ db = mmActual edge distance; Min(e1, e2) =
mmMinimum horizontal clearance; 10 mmActual horizontal clearance; ln - (b - tw) / 2 +
tp = mmPASS - Recommended detailing practices are metCheck 2: Supported beam - Bolt groupBolt
shearAssumed line of shear transfer; zv = gh + e2,b = mmCoefficients; ab,v = bb,v = 6
´ zv / (n1,1 ´ (n1,1 + 1) ´ p1) = Bolt shear area; As = mm2Bolt shear coefficient; av = Individual bolt
shear resistance; Fv,Rd = av ´ fu,bolt ´ As / gM2,b = kNBolt group shear
resistance; VRd,b,v = Nb,tot ´ Fv,Rd / Ö((1 + ab,v ´ Nb,tot)2 + (bb,v ´
Nb,tot)2) = kNUtilisation; VEd1 / VRd,b,v = Bolt bearing in the fin plateVertical
coefficients; k1,ver,pl = Min(2.8 ´ e2 / d0 - 1.7, 2.5) = ab,ver,pl =
Min(e1 / (3 ´ d0), p1 / (3 ´ d0) - 1/4, fu,bolt / fu,p, 1) = Horizontal coefficients; k1,hor,pl = Min(2.8 ´
e1 / d0 - 1.7, 1.4 ´ p1 / d0 - 1.7, 2.5) = ab,hor,pl = Min(e2 / (3 ´ d0), fu,bolt / fu,p, 1) = Vertical
resistance single bolt; Fb,ver,pl,Rd = k1,ver,pl ´ ab,ver,pl ´ fu,p ´ db ´ tp / gM2,b
= kNHorizontal resistance single bolt; Fb,hor,pl,Rd = k1,hor,pl ´ ab,hor,pl ´ fu,p ´ db ´ tp / gM2,b
= kNBolt bearing resistance; Vpl,Rd = Nb,tot / Ö(((1 + ab,v ´ Nb,tot) / Fb,ver,pl,Rd)2 +
(bb,v ´ Nb,tot / Fb,hor,pl,Rd)2) = kNUtilisation; VEd1 / Vpl,Rd = Bolt bearing in the beam webVertical
coefficients; k1,ver,wb = Min(2.8 ´ e2,b / d0 - 1.7, 2.5) = ab,ver,
wb = Min(e1,b / (3 ´ d0), p1 / (3 ´ d0) - 1/4, fu,bolt / fu,b, 1) = Horizontal coefficients; k1,hor,wb = Min(2.8 ´
e1,b / d0 - 1.7, 1.4 ´ p1 / d0 - 1.7, 2.5) = ab,hor,wb = Min(e2,b / (3 ´ d0), fu,bolt / fu,b, 1) = Vertical
resistance single bolt; Fb,ver,wb,Rd = k1,ver,wb ´ ab,ver,wb ´ fu,b ´ db ´ tw,b /