You are on page 1of 11

TO R N I E R

AEQUALIS™ PERFORM™
REVERSED
Glenoid

FI X AT I O N . AU G M EN TAT I O N . O R I EN TAT I O N .
Design Rationale

AEQUALIS™ PERFORM™ REVERSED Glenoid was


Walch Classifications
developed to address cuff tear arthropathy and
osteoarthritis, and designed to address A A B B C
all glenoid bone loss classifications from A11 A22 B11 B22 C

Walch and Sirveaux. Fixation is achieved with


central screws, peripheral screws, and ADAPTIS™
Sirveaux Classifications
Integrated Porous Metal. Defect-mimicking
augments addresses bone loss. A circular design
and independent central screw allows for an E0 E1 E2 E3 E4
E0 E1 E2 E3 E4
infinitely dialable construct.
Designed for complete
control in any situation.

Freedom in Fixation,
Peripheral screws are to be used in addition to the central fixation options. Augmentation & Orientation
Fixation
Central Screws & Press-Fit Post Options ADAPTIS™ Integrated Porous Metal
» Bottom loading baseplate » Press-fit post for bony ingrowth » Designed for long-term fixation » 3D Printed, biocompatible titanium alloy material
» 6.5mm or 9.5mm Central Screws » Intra-operative flexibility » Structure optimized for bony ingrowth » Demonstrated ingrowth as early as 4 weeks*

6.5mm 9.5mm 15mm


25mm

30mm

35mm

40mm

45mm

50mm Bone ingrowth at 4 weeks Bone ingrowth at 12 weeks

Peripheral screws are to be used in addition to the central fixation options. *Data on file.
Augmentation
Augments designed to address bone loss from Walch and Sirveaux classifications.

Lateralized Half-Wedge Full-Wedge On-axis reaming for precise, bone


preserving defect preparation.
A1 A2 A1 B1 A2 A1 B2 B1 A2 C B2 B1 C B2 C

A
AA E0
21 2
BA1B
E1 E0E2 BB12B2 E1E3 E0 BC2E2
E4
C E1 E3 C E2 E4 E3 E4
21

Defect mimicking augmentation


with bone preservation in mind.

E1E1E0 E2E2 E1 E3E3E2 E4E4 E3 E4


Orientation
Circular shape + Independent central screw = Infinitely dialable
Implant Offering
Lateralized Lateralized Half-Wedge Full-Wedge
33mm 36mm 39mm 42mm Standard 6.5mm (Standard) 9.5mm (Revision)
+3mm +6mm 35° 15°

50mm

Standard
29mm 45mm

40mm

Lateralized 35mm
(+3mm)
30mm
25mm
25mm

Eccentric 15mm

+2mm +3mm +4mm

Please refer to the surgical technique for the glenosphere mis-match chart. Peripheral screws are to be used in addition to the central fixation options.
Standard and Lateralized Technique

1. Circular Pin Guide 2. Baseplate Reamer 3. Baseplate Post Drill 4. Central Screw Drill (6.5mm or 9.5mm) 5. Central Screw Depth Gauge 6. Tap (optional)

7. Baseplate Assembly & Baseplate Insertion 8. Peripheral Screw Drill/Insertion 9. Peripheral Ream 10. Glenosphere Insertion
Half-Wedge Augment Technique Full-Wedge Augment Technique

1. Guide Pin 2. Paleo Ream 3. Augment Ream 4. Augment Trial 1. Guide Pin 2. Pilot Drill 3. Augment Ream 4. Augment Trial

5. Post Drill 6. Central Screw Drill 7. C


 entral Screw 8. Baseplate Insertion 5. Post Drill 6. Central Screw Drill 7. C
 entral Screw 8. Baseplate Insertion
Depth Gauge Depth Gauge
Notes Notes
Proper surgical procedures and techniques are the responsibility of the medical professional. This material is furnished for information purposes only. Each surgeon must
evaluate the appropriateness of the material based on his or her personal medical training and experience. Prior to use of any Tornier implant system, the surgeon should
refer to the product package insert for complete warnings, precautions, indications, contraindications, and adverse effects. Package inserts are also available by contacting
Wright. Contact information can be found in this document and the package insert.

10801 Nesbitt Avenue South 161 Rue Lavoisier


Bloomington, MN 55437 38330 Montbonnot Saint Martin
888 867 6437 France
952 426 7600 +33 (0)4 76 61 35 00
www.wright.com

™ and ® denote Trademarks and Registered Trademarks of Wright Medical Group N.V. or its affiliates.
©2017 Wright Medical Group N.V. or its affiliates. All Rights Reserved.

CAW-8767 Rev A DCR 171066 June-2017