Professional Documents
Culture Documents
MEC-SCAN
High Performance Tank Floorscanners
MEC-SCANTM Floorscanners
TM
The MEC-SCAN Floorscanners are designed and built for high speed, high performance inspection applications.
TM
Based on the Saturation Low Frequency Eddy Current technique, the MEC-SCAN Floorscanners allow the
detection of topside and underside corrosion in coated and uncoated tank floor plates.
This dynamic inspection technique utilises Eddy Current in combination with a magnetic field which has been
TM
proven in the industry to be superior to techniques like Magnetic Flux Leakage System. The MEC-SCAN
Floorscanners have powerful scanning capabilities in excess of 3 times the material thickness and 5 times the
coating thickness. They are also capable of detecting defects less than half the size of what is able to be detected
by the MFL technique.
Its superiority includes the unique feature of differentiation between the topside and underside defects as well as
distinguishing defects from false calls by means of the signal phase. It is also able to inspect both ferrous and non-
ferrous materials.
With its dedicated colour mapping and reporting software, accurate and reliable inspection results are provided in
real-time in the form of an extensive colour overview of the condition mapping, C-Scan report, statistical analysis
overview, individual defect listing and repair plate report.
TM
MEC-SCAN
High Performance Tank Floorscanners
Technical Specifications
MEC-F15 MEC-F30
GENERAL SPECIFICATIONS
Scanner Base (L x W x H ; Weight) 632 x 310 x 160 mm ; 61 Kg 632 x 415 x 200 mm ; 82 Kg
Scanner Arm (L x W x H ; Weight) 197 x 266 x 1000 mm ; 17 Kg
Control Box with Handle Bar (L x W x H ; Weight) 201 x 463 x 315 mm ; 3 Kg
No. of sensors 8 8
Sensor width 37.5 mm each 50 mm each
Scanning width 300 mm 400 mm
1
Typical wall thickness range * 0 – 15 mm 0 – 30 mm
Use for diameter Flat Flat
POWER SUPPLY UNIT
Outside the tank 110 – 240 VAC (optional external battery pack driven)
For motor & electronics inside the tank 24 VDC
Dimensions (L x W x H ; Weight) 500 x 400 x 200 mm ; 15 Kg
SIGNAL CABLE
2
Typical cable length * 100 metres
Weight 0.3 Kg/m
*1 Refers to the typical wall thickness range of standard material; may vary depending on material quality.
*2 The length of cable is divided into sections of 30m – 50m units; extended cable length available on request.
*3 Refers to possible detectability, depending on scanner stand-off, quality of material and general surface condition.
*4 Refers to possible detectability, depending on general surface condition.
Innospection Limited
Unit 1, Howemoss Avenue, Kirkhill Industrial Estate, Dyce, AB21 0GP, Aberdeen, United Kingdom
Tel : +44 (0)1224-724744 Fax : +44 (0)1224-774087