You are on page 1of 6

HEALTHCARE Enclosure

Global Services Organisation

Order No.: DD+DIS256.05E

*1YY6BP1*
1 Piece YY6BP MA1
DRYSTAR 5302
Type 5366/100

A350279.0
No. only needed for production purposes

Cam Drive Shaft Replacement Instructions

This document describes all steps of the Cam Drive Shaft replacement
procedure. The main steps are:
• Exchange Cam Drive Shaft
• Print and evaluate SMPTE test image

This documentation is only enclosed to Cam Drive Shaft CM+349277.X and


is no longer needed after installation.
In case of questions regarding the document please contact:
Phone + 49 89 6207 3949 Fax +49 89 6207 7274.

printed in Germany 2005-08-01


Agfa Company Confidential
Note:

Electrical connections and repairs must only be made by authorized


electricians.

Mechanical connections and repairs must only be made by authorized


technicians.

We reserve the right to technical changes.


DD+DIS256.05E Cam Drive Shaft Replacement

Required Spare Part, Tools & Time 1 Switch off and disconnect all cables

wa
ter
pro
of 2

5366QRM85 5366QRM16

2 Open top cover and remove left and 3 Disconnect connctor 1, remove two
right cover screws and remove cam drive module

2
4 2
1
1
3
2

2
3

5366QRM45a 5365QRM80

4 Mark belt outside with a waterproof pen 5 Remove belt and pulley

roof
wate
rp
3

Belt running direction important 2


Image artifacts when mounted
the wrong way 1
Mark belt outside with a waterproof pen.

5366QRM152 5366QRM26

DRYSTAR 5302 Page 3


2005-08-01 Agfa Company Confidential
Cam Drive Shaft Replacement DD+DIS256.05E

6 Open 2 screws, disconnect cable A and


7 Open hold down bracket
remove TPH fan

2
3
2

A
1

5366QRM47 5366QRM48

8 Open TPH module 9 Remove retaining ring and bearing bush

5366QRM49 5366QRM50

10 Take out cam drive shaft 11 Insert new cam drive shaft

5366QRM51 5366QRM57

Page 4 DRYSTAR 5302


Agfa Company Confidential 2005-08-01
DD+DIS256.05E Cam Drive Shaft Replacement

12 Insert bearing bush. Mount retaining 13 Close TPH module and hold down
ring. bracket

5366QRM58 5366QRM59

14 Mount TPH fan 15 Mount pulley and belt

2
1
2 1

A 4
3 2
5

5366QRM601 5366QRM31

16 Attention: Observe belt running


17 Mount cam drive module
direction

Belt running direction important 2


Image artifacts (17 mm banding)
when mounted the wrong way 3
Mount belt with mark outside. 1
See step # 4.
1
5366QRM153 5365QRM81

DRYSTAR 5302 Page 5


2005-08-01 Agfa Company Confidential
Cam Drive Shaft Replacement DD+DIS256.05E

18 Mount left and right cover . Close top


19 Connect all cables and switch on
cover

3 3 4 WARMING UP
Please Wait
1
4 5 Ready

3 1
2

5366QRM62 5366QRM23

20 Print a SMPTE testimage 21 Check image quality

1. Press the Key-operator key


2. Scroll down to “Print Image”
3. Press the Confirm key
4. Press the Confirm key to select “testimage”
5. Scroll down to “smpte_lin.zip”
6. Press the Confirm key
7. Press the Confirm key to select one copy
SELECT CA
Print Testimage
3 smpte_1300.zip
4 smpte_lin.zip

5366QRM07 5366QRM08

22 Your Drystar 5302 is ready to use

5366QRM09

Page 6 DRYSTAR 5302


Agfa Company Confidential 2005-08-01