M15S

OPERATION MANUAL

minikol M15S SHEAR En

MBE058F03 1
INDEX
FUNCTIONS:.................................................................................................................................................... 3

SPECIFICATIONS: ........................................................................................................................................... 3

MANUAL SINGLE ............................................................................................................................................ 4

SINGLE MODE................................................................................................................................................. 5

FAST LOAD CURRENT VALUE ...................................................................................................................... 7

PROGRAM MODE ........................................................................................................................................... 8

MANUAL SINGLE ............................................................................................................................................ 8

MANUAL SINGLE ............................................................................................................................................ 9

SELECT COUNTING DIRECTION ................................................................................................................ 10

MANUAL SINGLE .......................................................................................................................................... 10

PARAMETER SETTINGS .............................................................................................................................. 11

PARAMETER ................................................................................................................................................. 11

TROUBLESHOOTING ................................................................................................................................... 12

INSTALLATION .............................................................................................................................................. 14

POWER SUPPLY & HARDWARE ................................................................................................................. 15

EXTERNAL DIMENSION ............................................................................................................................... 16

2
MBE058F03
Functions:
1. Select one / two speed
2. Manual mode / Single mode / Program mode
3. 16 execution cycle each program, 999 cuts each execution.
4. Absolutely Positioning
5. Retract
6. Load origin value
7. mm/inch conversion
8. Unit : 0.1mm/0.05mm/0.01mm
9. One direction forward
10. Protect motor function
11. Battery life: 2.5 year
12. Real time self-diagnose

Specifications:
1. Dimension: 115w × 115h × 73d (mm)
2. Panel cut out: 93w × 108h (mm)
3. Mounting screws: M3 × 4 104 × 104 (mm)
4. Supply voltage: 24 VDC 50mA, C type 1.5V Battery × 1
5. Battery voltage control: Low power alarm via display
6. Cable length: 3m
7. Thermal expansion: α = 16 × 10-6 × 1/K
8. Sensor gap: max. 2.5mm
9. Display: 15mm LED × 6 digits × 2 lines
10. Output: 7 digital output (AC250V / 7A; DC24V/10A)
11. Input: 5 digital input (24VDC)
12. Operation element: 20 keys
13. Test mark / interfer..Protection class 3 accord. to IEC 801
14. Speed: 1.5m/s
15. Accuracy: ± (0.025+0.02L)mm ( L: Meter) )
16. Repeatability: 0.01mm

17. Temperature: Working : 0 + 50 ; Operating : -20 +70 ℃

18. Humidity: 95% rF Condensation not permitted )

3
MBE058F03
Manual mode:
Keyboard function: The operator can move the machine table by M15 keyboard.

7 8 9 F
Fast Backward Forward Fast

Example:
Current value on display = 100.00mm, execute trim function:
※Note: Trim function only available in “Manual mode” ( LED of Manual key blinks)

MANUAL
Press SINGLE
, LED is blinking

= HAnd Target window: HAnd

106.80

Press and hold 7 / 8 or 9 / F

to increase or decrease value.

4
MBE058F03
Single mode
In single mode, a program can be executed.

Example:
Assume
Current value window = 100.00mm
Cutting length (target): 200.00mm each

200mm

200mm

200mm

Step 1 Enter single mode


Press LED of manual key is off

Step 2. Enter the target value “200” and M15 will


display as:

Target value window tArGEt


Current value window
200

5
MBE058F03
Step3. Confirm the value and press
0000 The setting is confirm

The LED of “start” key is active (blinking).

Note:
1. Press to switch M15 between target and
200.00 count display.

100.00 Target value: 200.00


Or
Count value: 0000

2. To stop machine anytime, you can press STOP

Stop To re-start, press START .

135.82

6
MBE058F03
Fast Load Current Value
You can fast load current value by external button according to working piece.

Example:
Target value of M15 = 100.00mm
The new target value = 100.50mm

Step 1. Enter single mode. (LED of manual key is off)

Target value window 100.00


Current value window
100.00

Step 2. Enter new value “100.5” “

Target value window tArGEt


Current value window
100.5

Step 3. To confirm the new target value, press twice.

Target value window 100.50


Current value window
100.00

Step 4. Press the external button and wait for 1 second to complete.

Target value window 100.50


Current value window
100.50

7
MBE058F03
Program Mode
M15 provides 6 programs for user to pre-set cutting length and count accordingly.

EX :P1 100mm x 1 cut 100mm


P2 200mm x 3 cuts
200mm

Note: Press to exit PROG mode.


200mm

200mm

A. Setting
Step1. Press PROG to enter program mode.

MANUAL
To select program P1 – P6 by F or SINGLE

Target value window P1 01


.
Current value window
100.00

Step 2. To enter selected program (ex: P 01, “01” blinks), press PROG

8
MBE058F03
Step3. Enter the cutting length “100” for Program# 1.

Target value window trG 01


Current value window
100
Step 4. press enter to shows as below and you can enter the counts of cut by numeric
keys:

Target value window Cnt 01


Current value window
003

Please repeat step 1 to step 4 to set the next program.

Step 5. To complete the setting, please enter STOP , and .

B. Execute:

MANUAL
Step 1. Press PROG and F (or SINGLE
) to call pre-set program P1 – P6.

Step 2. Select the program and press START to start.

Target value window P1 01


Current value window
100.00

Note: You can press to exit function or STOP to stop machine operation anytime.

9
MBE058F03
Select counting direction
You can select the counting direction according to the machine movement.

MANUAL
Step1. Press SINGLE
to return single mode.

Step 2. Press F (LED of target window blinks)

Target value window F


Current value window
100.00

Step 3. Press “1”, to enter function.

Step 4. To choose direction ( dir - / - dir) by PROG .

Target value window - dir


Current value window
100.00

Step 5. Press to complete.

10
MBE058F03
Parameter settings
Only available in single mode. (LED of Manual Key is OFF)

Press F to enter the parameter setting and press numeric keys to select function

(F 0 – 99, please refer to chart below)

Target value window F


Current value window
100.00
Parameter

Parameter Display Description Default


0 CHAnGE Load origin value 0

1 dir Set counting direction dir-

2 OriGin Set origin value 0.00mm

3 Count Set tools offset dEcr

4 POSdir Set positioning approach ├──

5 SPEEd One or two speed positioning 2sp

6 rEtr Retract 1.00mm

10 Lo-End Set low software limit -50.00mm

11 Hi-End Set high software limit 1000.00mm

17 toLL Tolerance 0.30mm

19 FAuLt Motor fault detection 55

20 LinCOr Set linear coefficient 1.00000

30 PASS Lock / unlock parameter ----


33 SOurCE Show software release

90 rES Set resolution 0.01mm

99 GO.... Calibration

11
MBE058F03
Troubleshooting

SEnSor
1、 Display:
Error

Possible cause: a. no sensor,


b. 9 Pin connector is loosen,
c. wire broken or
d. the gap is too big between sensor and tape;
Excluding: Check the sensor, sensor cable and sensor connector.

CHAnGE
2、 Display:
rst

"Change RST" message appears when M15 detects a motion in the wrong direction.
For example: M15 swtiches the outputs to move forward, but the bed starts moving in
the reverse direction.
Usually this is caused by the wrong wiring of the three phase motor.

Excluding: Press to clear, check the wiring and change if necessary.

EnGinE
3、 Display:
FAuLt

Possible cause: a. motor fault,


b. motor over load,

Excluding: Power off and check the motor and wiring.

Error
4、. Display:

Possible cause: a. over soft-limit,


b. check parameter stting

Excluding: press to clear

12
MBE058F03
5、Display CHAnGE
bAtt

Possible cause: The battery charge is low


Excluding: a. Turn the power off
b. Change the battery

6、Display
(or other) tAr GEt
2

Possible cause: Wait fro enter target value.


Excluding: a.Enter target value
b.Press to exit

7、 Display
P1
(or other)
100.
100.0

Possible cause: In program mode


Excluding: a.Enter target value
b.Press to exit.

8、Display F
100.
100.0

Possible cause: In program mode


Excluding: Press to exit.

9、Display origin
(or other)
100.
100.00
Possible cause: In program mode

Excluding: Press to exit.

13
MBE058F03
Installation
A. Ensure to apply tape on clean, dry and plain surface.
B. For the best adhesion, please apply the tape with ambient temperature:
21~38℃.
C. We recommend to make a chamfer on the machine to install the tape.

+/- 3 < +/- 5° < +/- 5° < +/- 1,5°

Gap Magnetic tape


2,5 mm max.

Recommend Gap between tape and sensor: 1mm (Unit: mm)

4 17 4
3.5

15
11.2
Gap (sensor – tape) 25
10

14
MBE058F03
Power supply & Hardware
a. Power supply: DC24V 50mA, 2-pin connector
b. Battery: C type battery (1.5V) x 1 PC, battery life: 2.5 years (24 hrs)

c. Output (14-pin connector)


 Relay × 7: Forward, Reverse, low speed, positioning, imposition, and End
program.

 Comm NO

 AC240V/ 5A AC120V/ 10A DC24V/ 10A


(front view)
Back panel( )
STOP
RETRACT
d. Input: START
24V 24V 24V 24V 校正
24V
COUNT
-. 5-pin connector (left) OV (CUT QTY) OV
 COM T
 Start
 Stop COM
 Retract Input 5-pin (left) Input 5-pin (right)

 Count
━C type battery1.5V
Power 2-pin

-. 5-pin connector (right) Sensor (9-pin) Empty


OV +24V
 Fast load current value
(please refer to p. 6)
 Empty ▓ ▓ ▓ ▓ ▓ ▓ ▓
Forward Reverse low speed positioning imposition End Cut End program
 Empty COM NO COM NO COM NO COM NO COM NO COM NO COM NO

 Empty
Out put (14Pin)
 Com
Sensor: 9-pin connector (D-sub)

15
MBE058F03
External Dimension
Unit: mm
92
115 6 6

2.5
5.5
S

Battery

65.5
115

104

42
I/O
5.5

5
104
Ø 5 x 4P 5.5 5.5

73 60*
3 42 28
2.5

93

Panel cutout
108

*: Required extra space for installation: 60mm


(cable and connector)

5
16
MBE058F03