Professional Documents
Culture Documents
PRODUCT UPDATE
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Infrastructure Power for an On-Demand World
Power-One provides power management and conversion High-availability infrastructure applications include wireless
solutions to a diverse array of global customers, including communications, routers, optical networking, medical
many of the most well-known high-technology companies, as diagnostic, railway, semiconductor-test, and data
well as thousands of customers serviced through distribution. server/storage equipment.
Data and Voice Servers and Manufacturing and Medical Imaging Industrial
Communications Data Storage Test Equipment and Diagnostic and Railway
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Power Conversion and Management from AC to IC
Any Voltage, Any Current, Any Power Architecture
Power-One’s over 2500 products support every step in the Programmable and modular products can be readily
management and conversion of utility-grade AC into the low configured to meet many customer requirements. In addition,
DC voltages required to power high-speed ICs. A unique standard products provide proven platforms for modified and
combination of product breadth and flexibility provides a custom solutions.
power solution for virtually any application.
Z-One Digital IBA
Bricks and POL Converters
Board Level
2
• POLs in industry-standard or high-power-density • Hardware-configurable and I C-programmable models
Power-One footprints deliver 0.7 to 5.5 VDC. • Optional wizard-driven graphical user interface
• Fixed-ratio and fully-regulated bricks, 1/8 to full, • Dramatically simplified power-system development
with up to four outputs from 0.8 to 54.3 VDC • Significantly reduced component count improves
• Power-over-Ethernet (PoE) bricks reliability, cost, and power density.
• Non-brick isolated products are also available,
including extended-temperature-range models.
Chassis Mount
Industrial Products
AC-DC Front Ends
System Level
• Environmentally-controlled
outdoor power cabinets
• Nominal 24 or 48V outputs
• Scalability is enabled by
• Rectifiers, controllers, power shelves, primary hot-swappable rectifiers
and secondary distribution cabinets and modular distribution.
• Web-enabled PowCom software enables
remote reporting and management of multiple
DC power systems.
1
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Download the DC-DC Product Update for DC-DC Product Information
Single Output 14 15 16 18 19 19 19
Dual Output ● ● 22 23 23 ● 24
Triple Output ● ● 28 ● ● ● 29
Quad Output ● ● ● ● ● ● 32
Input Filters ● ● ● ● ● ● 14
www.power-one.com
2
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
AC-DC Table of Contents
Nuclear and Medical Applications— Power-One products are not designed, intended for use in, or authorized for use
as critical components in life support systems, equipment used in hazardous environments, or nuclear control
systems without the express written consent of the respective divisional president of Power-One, Inc.
Technical Revisions— The appearance of products, including safety agency certifications pictured on labels, may PODS16 outdoor power systems
change depending on the date manufactured. Specifications are subject to change without notice.
utilize 93.5% efficient rectifiers
3
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
This page intentionally left blank.
www.power-one.com
34
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Railway and Rugged Product Overview
35
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
AC-DC > Cassette > M Series
Unsigned output voltages are isolated and can be used as either + or - polarities.
H Series Model
Output Output Power Input Voltage
Output Adjustment Ranges
1, 2, 3 (VDC) 1, 2, 3 (Amps) (Watts) 85 to 255 VAC Options
The following adjustment ranges
apply to single-output models. 5.1 11 56 LH1001-2R D
www.power-one.com
42
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
AC-DC > Cassette > S Series & S Series with PFC
Unsigned output voltages are isolated and can be used as either + or - polarities.
43
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
AC-DC > Cassette > K Series & K Series with PFC
Unsigned output voltages are isolated and can be used as either + or - polarities.
www.power-one.com
44
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Alpha-sorted graphics and
dimensions augment model
AC-DC > DIN-Rail Mount > LOK, LOR, LOS Series listings from both pages.
Unsigned output voltages are isolated and can be used as either + or - polarities.
45
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
AC-DC > DIN-Rail Mount > X Series with PFC
Unsigned output voltages are isolated and can be used as either + or - polarities.
www.power-one.com
46
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Alpha-sorted graphics and
dimensions augment model
AC-DC > Linear Supplies > Single Output listings from both pages.
Unsigned output voltages are isolated and can be used as either + or - polarities.
47
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
AC-DC > Linear Supplies > Dual Output
Unsigned output voltages are isolated and can be used as either + or - polarities.
*Some factory set Vout’s may require jumpering. See data sheet for details.
www.power-one.com
48
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
AC-DC > Linear Supplies > Triple Output
Unsigned output voltages are isolated and can be used as either + or - polarities.
49
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
AC-DC > Chassis Mount > Single Output
Unsigned output voltages are isolated and can be used as either + or - polarities.
12 and 15Vout
12 10.8 to 13.2 2.5 90 to 264 30 BLP30-1012
12 11.4 to 13.2 3.3 85 to 264 40 BLP40-1012
BLP40/BLP55
12 11 to 18 3.4 85 to 264 55 MAP42-1012
5.00 x 3.00 x 1.07 inch
127.0 x 76.2 x 27.2 mm 12 11.4 to 13.2 4.5 85 to 264 55 BLP55-1012
12 11.4 to 15.8 5 90 to 264 60 MAP55-1012
• Remote Sense
• Only 10 CFM Cooling Required +12 10.8 to 13.2 6.5 85 to 264 75 PLP75-1012
• 1U Height Compliant 12 11.5 to 15.5 7.5 90 to 264 80 MAP80-1012
• Single and Triple-Output Models 12 11 to 13 8.4 85 to 264 100 MPB80-1012
12 11.2 to 15.8 10 85 to 264 110 MAP110-1012
12 11.8 to 12.2 10.5 90 to 264 125 MPB125-1012
12 11.4 to 15.8 12 90 to 264 130 MAP130-1012
12 11 to 16 12.5 85 to 264 150 MAP140-1012
12 11.6 to 16 17 85 to 264 200 MPU200-1012
12 10.8 to 13.5 21 85 to 264 250 PFC250-1012
12 10.8 to 13.5 30 85 to 264 375 PFC375-1012
FXC6000/7000 15 13.5 to 18.3 17 85 to 264 250 PFC250-1015
15.17 x 8 x 5 inch
15 12 to 17 25 85 to 264 375 PFC375-1015
38.5 x 20.3 x 12.7 cm
• Three-Phase AC Input Additional single-output products are described in the
• 230/480VAC Operation
Hot-Swap Front-End and Modular solutions sections.
• 3U or 5U Height
MAP55/MAP80/MAP130 MAP110/MAP140
MAP30/40/42 MAP55 7.00 x 4.30 x 1.80 inch
6.00 x 3.27 x 1.60 inch 177.8 x 109.2 x 45.7 mm
5.00 x 3.00 x 1.16 inch 152.4 x 83.1 x 40.6 mm
127.0 x 76.2 x 40.6 mm • Remote Sense on Main
MAP80 Outputs
• Universal input 85-264 VAC 7.20 x 4.20 x 1.80 inch • Optional L-Bracket & Cover
• CE Marked to the Low 182.9 x 106.7 x 45.7 mm
Voltage Directive MAP130
8.50 x 4.50 x 2.00 inch
215.9 x 114.3 x 50.8 mm
www.power-one.com
50
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Alpha-sorted graphics and
dimensions augment model
AC-DC > Chassis Mount > Single Output listings from both pages.
Unsigned output voltages are isolated and can be used as either + or - polarities.
PFC375/PFC500
9.00 x 5.00 x 2.50 inch
228.6 x 127.0 x 63.5 mm
MAP40
5.00 x 3.00 x 1.16 inch
AC-DC > Chassis Mount > Triple Output
127.0 x 76.2 x 40.6 mm
• Universal input 85-264 VAC Factory Max Input
Set Vout Current Voltage Power
Vout (VDC) Trim (VDC) (Amps) (VAC) (Watts) Model
One 3.3V, One 5V, and One 12V Output
+3.3 N/A 5 85 to 264 37 BLP55-3300
+5 N/A 2.5
+12 N/A 0.7
MAP140
+3.3 3 to 3.6 8 85 to 264 58 PLP75-3300
7.00 x 4.30 x 1.80 inch +5 4.5 to 5.5 4
177.8 x 109.2 x 45.7 mm
+12 10.8 to 13.2 1
• Remote Sense on Main
+3.3 3.1 to 3.9 8.5 85 to 264 80 MPB80-3300
Outputs
+5 4.7 to 5.8 5
+12 N/A 0.7
+3.3 3.1 to 3.8 35 85 to 264 150 MPU150-3300
+5 5 to 5.5 20
+12 N/A 2
www.power-one.com
52
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Alpha-sorted graphics and
dimensions augment model
AC-DC > Chassis Mount > Triple Outputs listings from both pages.
Unsigned output voltages are isolated and can be used as either + or - polarities.
53
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
AC-DC > Chassis Mount > Quad Outputs
Unsigned output voltages are isolated and can be used as either + or - polarities.
www.power-one.com
54
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Alpha-sorted graphics and
dimensions augment model
AC-DC > Chassis Mount > Quad Outputs listings from both pages.
Unsigned output voltages are isolated and can be used as either + or - polarities.
55
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
AC-DC > Chassis Mount > Quad Outputs
Unsigned output voltages are isolated and can be used as either + or - polarities.
www.power-one.com
56
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Alpha-sorted graphics and
dimensions augment model
AC-DC > Chassis Mount > Quad Outputs listings from both pages.
Unsigned output voltages are isolated and can be used as either + or - polarities.
57
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
AC-DC > Chassis Mount > Quad Outputs
Unsigned output voltages are isolated and can be used as either + or - polarities.
NET2
8.25 x 4.50 x 1.59 inch
Additional quad-output products are described in the
209.6 x 114.3 x 40.4 mm Modular solutions sections.
• Power Factor Correction
Meets EN61000-3-2
• Isolated V2 and V3 Outputs
• Overtemperature, Overload, Reduction of Hazardous Substances (RoHS)
and Overvoltage Protection
• No Minimum Load In accordance with the full range customers with compliance
Requirement of compliance options described choices that will not be offered by
in the European Union's RoHS all power-system manufacturers.
Directive, Power-One is offering Please refer to the outside back
products in lead-free and cover of this brochure, or visit
lead-solder-exempted versions. www.power-one.com for further
This two-tiered strategy provides details.
www.power-one.com
58
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
CompactPCI, DC-DC & AC-DC
Unsigned output voltages are isolated and can be used as either + or - polarities.
Power-One’s hot-swap CompactPCI power supplies are fully compliant to the PICMG 2.11 Power Interface Specification,
and use a standard Positronic 47-pin connector. EDGE technology delivers up to 40 amperes on both the +5 and +3.3 volt
outputs at 50ºC on the 3U models, and 50 and 60 amperes respectively, on the 6U model’s +5 and +3.3 volt outputs.
Remote sense and active current share on the +5, +3.3, and +12 volt outputs, along with ORing FETs facilitate use in
redundant, hot-swap applications. These feature-rich products meet international safety standards, and display the CE Mark CPA200/CPA250
for the Low Voltage Directive (LVD). 3U x 8HP (8TE) x 6.3" (160mm)
The 10.4" x 4" x 1.6" package is designed for 1U high applications and features a front panel that includes alarm and PALS400/PALS600
monitor LED's, AC input connector, on/off switch, integral handle, and a fan inlet. The hot-swap SSI type rear connector 10.40 x 4.00 x 1.59 inch
2
provides output power and access to I C, power fail, active current share, remote sense, output good, power-supply 264.2 x 101.6 x 40.4 mm
present, and remote enable interface signals.
Protection features include overload and short circuit, brownout, overtemperature/fan fail warning and shutdown, output
overvoltage, and MOV input-transient. Agency approvals include UL1950, CSA 950, and EN60950 (TUV).
59
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
AC-DC > Hot-Swap Front Ends
Front-Mounted AC Receptacle
Factory
Set Vout Standby Vin Power Mating Shelf
Vout (VDC) Trim (VDC) Amps Vout (VAC) Supply Shelves (Amps)
12 N/A 25 12V @ 0.7A 85 to 264 FNP300-12 N/A N/A
12 7 to 12 50 12V @ 0.5A 85 to 264 FNP600-12 FRHN850 250
12 7 to 12 71 12V @ 0.5A 85 to 264 FNP850-12 FRHN850 355
12 N/A 125 12V @ 1A 85 to 264 2 FNP1500-12 1 FRHN1500 375
24 N/A 12.5 12V @ 0.7A 85 to 264 FNP300-24 N/A N/A
48 N/A 6.25 12V @ 0.7A 85 to 264 FNP300-48 N/A N/A
48 N/A 12.5 12V @ 0.5A 85 to 264 FNP600-48 FRHN850 62
48 N/A 21 12V @ 0.5A 85 to 264 FNP1000-48 FRHN850 105
48 44.2 to 51.8 31 12V @ 1A 85 to 264 2 FNP1500-48 FRHN1500 93
48 44.2 to 51.8 37.5 12V @ 1A 85 to 264 2 FNP1800-48 FRHN1500 112.5
Rear-Mounted AC Connector
Factory
Set Vout Standby Vin Power Mating Shelf
Vout (VDC) Trim (VDC) Amps Vout (VAC) Supply Shelves (Amps)
12 N/A 125 12V @ 1A 85 to 264 2 FXP1500-12 1 FRHX1500 375
32 30.5 to 33.5 175 12V @ 0.5A 180 to 264 or 342 to 528 FXP6000-32-S FRH7000/FRV7000 350/525
48 N/A 21 12V @ 0.5A 85 to 264 FXP1000-48 1 FRHX850 105
48 44.2 to 51.8 31 12V @ 1A 85 to 264 2 FXP1500-48 1 FRHX1500 93
48 44.2 to 51.8 37.5 12V @ 1A 85 to 264 2 FXP1800-48 1 FRHX1500 112
48 45.6 to 50.4 125 12V @ 0.5A 180 to 264 or 342 to 528 FXP6000-48-S FRH7000/FRV7000 250/375
48 45.6 to 50.4 145 12V @ 0.5A 180 to 264 or 342 to 528 FXP7000-48-S FRH7000/FRV7000 290/435
1 Consult factory for availability. 2 See data sheet for derating values.
www.power-one.com
60
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
AC-DC > Hot-Swap Front Ends
Power Shelves
Shelf Max
Vout Iout** Vin Uses Power No. of Power
(VDC) (Amps) (VAC) Shelf Height Width Depth Supply Supplies
12 250 85 to 264 FRHN850 1U 19” 13” FNP600-12 5
12 355 85 to 264 FRHN850 1U 19” 13” FNP850-12 5
12 375 85 to 264 2 FRHN1500 1U 19” 13” FNP1500-12 1 3
12 375 85 to 264 2 FRHX1500 1U 19” 14” FXP1500-12 1 3
32 350 180 to 264 FRH7000 3U 17.5” 24” FXP6000-32-S 2
342 to 528
32 525 180 to 264 FRV7000 5U 17.5” 24” FXP6000-32-S 3
342 to 528
48 62 85 to 264 FRHN850 1U 19” 13” FNP600-48 5
48 93 85 to 264 2 FRHN1500 1U 19” 13” FNP1500-48 3
48 93 85 to 264 2 FRHX1500 1U 19” 14” FXP1500-48 1 3
48 105 85 to 264 FRHN850 1U 19” 13” FNP1000-48 5
48 105 85 to 264 FRHX850 1U 19” 14” FXP1000-48 1 5
48 112 85 to 264 2 FRHN1500 1U 19” 13” FNP1800-48 3
48 112 85 to 264 2 FRHX1500 1U 19” 14” FXP1800-48 1 3
48 250 180 to 264 FRH7000 3U 17.5” 24” FXP6000-48-S 2
342 to 528
48 290 180 to 264 FRH7000 3U 17.5” 24” FXP7000-48-S 2
342 to 528
48 375 180 to 264 FRV7000 5U 17.5” 24” FXP6000-48-S 3
342 to 528
48 435 180 to 264 FRV7000 5U 17.5” 24” FXP7000-48-S 3
342 to 528
1 Consult factory for availability. 2 See data sheet for derating values.
** Shelf amps and number of power supplies are maximum values. Shelves may be partially populated to provide reduced currents.
Consult data sheet for blank panel part numbers.
61
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
AC-DC > ESP/ESM Modular Power Supplies
Features
• 1 to 12 isolated outputs with full user configurability
• 1.45V to 28V standard output voltages
• Isolated bias supply voltage of 5V @ 50mA
• Class B conducted emissions
• 400, 600 and 1000 Watts of output power
• Series and parallel capability
• Zero-load operation
• EN61000-3-2 compliant
• Universal input
ESP Flexibility
Notes: Notes:
Maximum current = (I1 + I2) x .9 Maximum voltage to chassis is 500V
Use two parallel links Use series link
Reverse bias diodes may be required for certain applications,
e.g., large capacitive loads
www.power-one.com
62
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
AC-DC > ESP/ESM Modular Power Supplies
Unsigned output voltages are isolated and can be used as either + or - polarities.
Module No. of Slots Nominal Voltage Range Imax Output control signals are available on all output modules.
(see application note)
Module 1 1 5V 3 to 5.6V 30A
Modules 1 to 6 Module 70 Additional Features
Module 2 1 12V 5 to 13V 20A • Power good signal • Adjustable Current Limit
• Output inhibit signal • Foldback or Straight Line Current
Module 3 1 18V 8 to 20V 15A
Limiting
Module 4 1 24V 12 to 28V 12A • Remote adjust (margin) • Bias Voltage
• Selectable Output Inhibit or
Module 70 2 5V 1.45 to 5.6V 80A Enable
Dual output modules:
Output signals available on first [top] output only.
Dual-Output Module Selection
Production Configuration:
Module No. of Slots Nominal Voltage Range Imax Units are shipped with nominal output voltages unless special
configuration is specified. Power-One can configure to your exact
Module 5 1 24V 10 to 28V 3A
requirements through use of appropriate series and parallel busbars,
24V 10 to 28V 3A
and voltage adjustment to specific set points.
Module 6 1 5V 3 to 5.6V 10A
ESP/ESM Standard Options
1 24V 10 to 28V 3A
06 Mains Power Fail + Global Enable + Bias Supply Voltage
07 Mains Power Fail + Global Inhibit + Bias Supply Voltage
— = standard configuration
How to Order ESM6 or ESP6 (ESM6 shown in example)
C = special configuration
(Available in 600/1000 Watt Versions)
Note: Calculate power
requirements by summing
ESM 6D 12 24 45 — 07 Use 00 if no options
output powers calculated at are desired.
Series Option code
application output voltages.
Number of slots Slot F
}
For ESP/ESM6D:
Limit total power from slots C = 600W
A-C and D-F to 550W each.
Power Slot E
D = 1000W Use 0 for unfilled slots
Slot A Slot D
Slot B Slot C
Specifications of ESM6 part number example:
• 6-slot series
• Maximum output power: 1000W
• 5V @ 30A; 12V @ 20A; 12V @ 20A; 24V @ 12A; 24V @ 12A; 24V @ 3A; 24V @ 3A
• Mains Power Fail signal + Logic Inhibit + Bias Supply Voltage
63
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
AC-DC > Modular High Power Series
www.power-one.com
64
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
AC-DC > Modular High Power Series
Vout 1 2 3.3 5 6 8 10 12 14 18 20 28 36 48
to to to to to
2 3 15 24 30
Max Amps 35 35 35 35 35 20 20 20 10 10 10 8 20 5
to to to to to to to to to to to to to to
640 830 830 800 500 320 320 320 250 132 165 145 115 89
Vout1 5 5 5 5 5.2 5 5 5 12 5 24
Vout2 1.5 1.5 2.2 12 12 12 15 24 12 15 12
Vout3 3.3 12 12 12 12 24 15 24 12 12 12
Max Amps 15 10 10 10 15 10 10 10 10 10 5
10 10 10 10 8 10 8 5 10 8 10
10 10 10 10 8 5 8 5 10 10 10
Please visit www.power-one.com to configure a modular solution to power your voltage and current requirements.
65
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Power-One Increases Customers’ Choices with
RoHS Lead-Free and Lead-Solder-Exempted Products
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com