Test Technique
Continuous Method: Wet Dry
Residual Method : Wet Dry
Magnetic Particles Non-Fluorescent (Visible) Fluorescent
Test Carried out Before PWHT After PWHT
Magnetizing AC HWDC DC
current
Inspection Under Visible light: Artificial light Ultra Violet light
Calibration For AC: 4.5 Kgs (10 Lbs.)
(Lifting Capacity) For DC: 18.1 Kgs. (40 Lbs.)
Description of Item:- Serial No.: 8308 CRANE HOOK
T e st Re sult:
Sl.No De sc ripti on Obse rv ati on Re sult Re marks
1 8308 - SMALL HOOK - N .R.I A CCE P T
2 8308 - LARGE HOOK - N .R.I A CCE P T
NO T E : - N .R.I: - N O RE LE V A NT IND ICA T ION