You are on page 1of 175

WIRELESS

ENHANCEMENT
Product Catalogue
2017
Legal Disclaimer

Comba Telecom Ltd retains copyright on all the text, graphics and trademarks displayed on this paper. All the text, graphics and
trademarks displayed on this paper are owned by Comba Telecom Ltd and used under licence by Comba affiliates.

You may print copies of the information on this paper and store the files on your computer for your personal use. You may not
distribute text or graphics to others without the express written consent of Comba Telecom Ltd and Comba affiliates. Also, you
may not, without our permission, copy and distribute this information on any other server, or modify or reuse text or graphics on this
or any other system.

No reproduction of any part of the paper may be sold or distributed for commercial gain, nor shall it be modified or incorporated in
any other work, publication or site, whether in hardcopy or electronic format, including postings to any other site. Comba Telecom
Ltd reserves all other rights.

The information on this paper had been included in good faith and is for general purposes only. It should not be realised upon for
any specific purpose and no representation or warranty is given as regards to its accuracy or completeness.

No Information on this paper shall constitute an invitation to invest in Comba Telecom Ltd or any of its affiliates. Neither
Comba Telecom Ltd and Comba affiliates, nor their or their affiliates' officers, employees or agents shall be liable for any
loss, damages or expenses arising out of any access to or use of this paper or any site linked to it, including, without
limitation, any loss of profit, indirect, incidental or consequential loss.
Index
About Us........................................................................................................................................................................6
Solution Overview ..........................................................................................................................................................7
Product Overview ...........................................................................................................................................................8
Comba DAS - ComFlex Series Overview .............................................................................................................................8
Comba Wireless Repeater Series Overview .........................................................................................................................9
CMS Typical Network Management Diagram......................................................................................................................10
WEBU Profile................................................................................................................................................................ 11
Product Application Scenario ........................................................................................................................................14
ComFlex Series Distributed Antenna System .....................................................................................................................19
ComFlex-5H00(CI) 1W2W ..................................................................................................................................19
ComFlex-5000(CI) 1W2W ..................................................................................................................................22
ComFlex-6100(CI) 1W ........................................................................................................................................25
ComFlex-4500(CI) 2W5W ..................................................................................................................................28
ComFlex-4100(CI) 5W ........................................................................................................................................31
ComFlex-5200(CI) 20W40W ..............................................................................................................................34
ComFlex-5P00(CI) 20W .....................................................................................................................................37
ComFlex-5000(CI) 20W40W ..............................................................................................................................40
ComFlex-4500(CI) 10W20W ..............................................................................................................................43
ComFlex-4C00(CI) 20W40W ..............................................................................................................................46
ComFlex-4100(CI) 40W ......................................................................................................................................49
ComFlex CM 20W ..............................................................................................................................................52
ComFlex-8A00(CM) 20W ...................................................................................................................................58
ComFlex-8C00(CM) 20W ...................................................................................................................................61
ComFlex-5M00(AI) 10W20W .............................................................................................................................64
ComFlex-5900(AM) 20W ....................................................................................................................................67
ComFlex-4100(AM) 20W ....................................................................................................................................70
ComFlex-8A00(AM) 20W ...................................................................................................................................73
RX Series Digital Band Selective Repeater .........................................................................................................................76
RX-0739...............................................................................................................................................................78
RX-8132...............................................................................................................................................................79
RX-9139...............................................................................................................................................................80
RX-1839...............................................................................................................................................................81
RX-1939...............................................................................................................................................................82
RX-2139...............................................................................................................................................................83
RX-2620...............................................................................................................................................................84
Multi-band Digital Band Selective Repeater ........................................................................................................................85
RX-7137...............................................................................................................................................................88
RX-7539...............................................................................................................................................................90
RX-7639...............................................................................................................................................................92
RX-7839...............................................................................................................................................................94
RX-5239...............................................................................................................................................................96
RX Series Digital Channel Selective Repeater.....................................................................................................................98
RX-2123 III3 ........................................................................................................................................................98
RX-0823.............................................................................................................................................................100
RX-2123 IV4 ......................................................................................................................................................102
RX-0823.............................................................................................................................................................105
RX-9123.............................................................................................................................................................106
700/800MHz Public Safety Bi-directional Amplifier ............................................................................................................109
RX-7W22 ...........................................................................................................................................................109
800MHz Tetra Band Selective Repeater ............................................................................................................................ 111
RX-8039............................................................................................................................................................. 111
mBDA Series Digital Band Selective Repeater .................................................................................................................. 112
mBDA-0733 ...................................................................................................................................................... 113
mBDA-0833 ...................................................................................................................................................... 114
mBDA-9133 ...................................................................................................................................................... 115
mBDA-1833 ...................................................................................................................................................... 116
mBDA-1933 ...................................................................................................................................................... 117
mBDA-2033 ...................................................................................................................................................... 118
mBDA-2133 ...................................................................................................................................................... 119
mBDA-2633 ......................................................................................................................................................120
Combiner for Dual Single Band mBDAs ...................................................................................................................121
mBDA Indoor Digital Band Selective Repeater ..................................................................................................................123
mBDA-100.........................................................................................................................................................123
mBDA-200S ......................................................................................................................................................126
mBDA-300.........................................................................................................................................................130
Band Adjustable Pico Repeater ......................................................................................................................................134
SP-9110 .............................................................................................................................................................135
SP-2110 .............................................................................................................................................................136
MP Series Digital Pico Repeater .....................................................................................................................................137
MP-0832 ............................................................................................................................................................138
MP-8132 ............................................................................................................................................................139
MP-9132 ............................................................................................................................................................140
MP-1832 ............................................................................................................................................................141
MP-1932 ............................................................................................................................................................142
MP-2132 ............................................................................................................................................................143
MP-2632 ............................................................................................................................................................144
Multi-band Digital Pico Repeater.....................................................................................................................................145
Dual-band Digital Pico Repeater .....................................................................................................................................146
MP-7V32 ............................................................................................................................................................146
MP-7532 ............................................................................................................................................................148
MP-7632 ............................................................................................................................................................150
MP-7832 ............................................................................................................................................................152
Tri-band Digital Pico Repeater ........................................................................................................................................153
MP-5K32............................................................................................................................................................153
MP-5232 ............................................................................................................................................................154
MP-5832 ............................................................................................................................................................155
Location System- RSSI Base Station ...............................................................................................................................160
LB-2112 .............................................................................................................................................................160
Location System- TDOA Base Station .............................................................................................................................162
LB-2115 .............................................................................................................................................................162
Location System- Software Platform ...............................................................................................................................164
LIMS ..................................................................................................................................................................164
Location System- ID Tag................................................................................................................................................167
LT-2102..............................................................................................................................................................167
Location System-Wrist Strap..........................................................................................................................................168
LT-2103 II2.........................................................................................................................................................168
Location System-TDOA Base Station ..............................................................................................................................170
TDJ-2400BKF-Y ................................................................................................................................................170
Coverage Management System ......................................................................................................................................171
CMS V8.2 ..........................................................................................................................................................171
About Us
Comba Telecom is a leading supplier of infrastructure and wireless enhancement solutions to mobile operators and enterprises
to enhance and extend their wireless communications networks. Established in 1997, and listed on the Hong Kong Stock
Exchange in 2003, it has grown to become a global supplier with its extensive distribution network and 60+ offices globally.

With seasoned team of research and development engineers and its state-of-the-art design tools and testing equipment, Comba
is able to provide its innovative patented designs and yet cost-effective products to the customers. After working with Operators /
Private enterprise networks seamless all over the word for more than 10 years, it is able to help the customers to roll out their full
scale range network quickly with the professional, customized, quality guarantee product solutions.

Comba Wireless Enhancement Business Unit offers full range of wireless enhancement products, also Coverage
Management System (CMS) for wireless communication network systems, which include:

 Active DAS
 Wireless Repeater
 Public Safety Repeater
 Location System
 Coverage Management System

Comba is committed to quality consistency and environmental protection and is ISO9001 and ISO14001 certified. With its highly
efficiency production lines in China and strict process control system, Comba's manufacturing facility is able to deliver high volume
products with consistent quality.

Comba Manufacturing Facility in Guangzhou, China Comba R&D Centre in Guangzhou, China
Solution Overview Applications

Scenic Areas
Stadium/Large Venues In-Building Solutions
(Camouflaged Solutions)

Subways & Tunnels

Wireless Backhaul Solutions

Base Station Solutions


Rural Area Solutions

Metro Area Solutions

1 1 © 2014 Comba Telecom. All Rights Reserved

Solution Overview

Comba’s wide range of indoor/outdoor repeater products provide total solutions for mobile network from covering blind sports to
implementing integrated coverage systems. The deployment of repeaters will effectively optimized network efficiency by
centralizing / redirecting traffic capacity and enhancing power budget.

 Compliant to all major technologies including GSM, CDMA, WCDMA, LTE, and Tetra.

 Widely frequency range compliance e.g. 700MHz, 800MHz, 850MHz, 900MHz, 1800MHz, 1900MHz, AWS, 2100MHz,

2300MHz and 2600MHz.

 Support multi-modulations and multi-operators applications so that providing cost-effective solutions.

 Support various output power from 0.01 W to 40 W.

 Wide range of product line that can be used from high-rise building to underground railway for all kinds of applications.
Product Overview
Comba DAS - ComFlex Series Overview

Highlight: Highlight:
 Max. 100W input power from BTS.  Max. 100W input power from BTS.

 -163dBc PIM.  -163dBc PIM.

 WEB GUI, RF routing and diagnosis function.  WEB GUI, RF routing and diagnosis function.
 Max. supports 32 RF input and 32 RUs connection.  Max. supports 32 RF input and 32 RUs connection.
 RU output power 1/2/5/10/20/40W.  Modular designed RU supports up to 8 bands, 20W per

band without fan.

Highlight:
 Max. 100W input power from BTS.

 -163dBc PIM.

 Supports flexible SISO & MIMO and multi-sector.

 RU output power 1/2/5/10/20/40W.

 WEB GUI

Highlight: Highlight:
 Max. supports 8 RF input and 16 RUs.  Max. supports 8 RF input and 16 RUs.

 Modular design easy for upgrade and maintenance.  Modular design easy for upgrade and maintenance.

 Supports multi-operator input and each adjustable gain.  Supports multi-operator input and each adjustable gain.

 Modular designed RU supports up to 8 bands, 20W per  RU output power 1/2/5/10/20/40W.

band without fan.  WEB GUI, automatic calibration and commissioning.

 WEB GUI, automatic calibration and commissioning. 


Comba Wireless Repeater Series Overview

Wireless High Power RX Series

Band Channel Selective Public Safety


Selective Series Series
Series

Highlight: Highlight: Highlight:

 Support indoor/outdoor  Support indoor / outdoor  Support indoor / outdoor

 4 Sub bands, 90 dB gain.  Support ICS, 105 dB gain.  Support Tetra system.

 5/10/20w output power.  2/5/10/20w output power.  Support 2W output power.

 Support Dual/Tri Bands.  Support Dual/Tri Bands.

Wireless Medium Power mBDA Series

Outdoor mBDA
Indoor mBDA Series Series

Highlight: Highlight:
 Support indoor.  Support outdoor.
 3 Sub bands, 80 dB gain.  3 Sub bands, 80 dB gain.
 0.5/1/2W output power.  0.5/1/2W output power.
 Support up to 6 Bands.  Support Dual/Tri Bands.

Wireless Low Power Pico Series

Analog Pico
Series Digital Pico Series

Highlight: Highlight:

 Support indoor.  Support indoor.

 1 Sub bands, 65 dB gain.  2 Sub bands, 75 dB gain.

 13/15/17dBm output power.  13/15/17dBm output power.

 Support Dual/Tri Bands.  Support Dual/Tri Bands.

 Central Freq./ band width settable.


CMS Typical Network Management Diagram

GPRS/CDMA
1x/HSDPA Repeater1 Repeater2

OMT v5
Repeater3 ...

Internet CMS user

Wired TCP/IP connection

IP Gateway TCP/IP connection between operator PSD network and Internet

CMS Server TCP/IP connection by which OMT login Internet

TCP/IP connection by which CMS Client login Internet


Network Control
Wired TCP/IP connection by which IP Gateway login Internet
Center
CMS user Wireless GPRS/CDMA 1x/HSDPA connection
WEBU Profile
DAS Series

Product Photo Name Power Bands System

700/800E/850/900/1800/1900/
1W AWS/2100/2300/
GSM/UMTS/
ComFlex MU (Max. 2600
LTE/CDMA
Input) Max. 8

MU

700/800E/850/900/1800/
100 W
ComFlex Plus 1900/AWS/2100/2300/ GSM/UMTS/
(Max.
ACU 2600 LTE/CDMA
Input)
Max. 32

700/800/850/900/1800/
2/5 W 1900/AWS/2100/2300/ GSM/UMTS/
Low Power RU
(Output) 2600 LTE/CDMA
Max. 4

700/800/850/900/1800/
1900/AWS/2100/2300/
20/40 W GSM/UMTS/
RU High Power RU 2600
(Output) LTE/CDMA
Max. 4

700/800E/850/900/1800/
1900/AWS/2100/2300/
10/20 W GSM/UMTS/
Modular RU 2600
(Output) LTE/CDMA
Max. 8
Wireless Repeater High Power RX Series

Product Photo Name Power Bands System

Band
800/850/900/1800/1900/ GSM/UMTS/
Selective RX-xx39 5/10 W
2100/2600 LTE/CMDA
RX Series

Channel
GSM/UMTS/
Selective RX-xx23 5/10/20 W 800E/900/2100
LTE
RX Series

Public
Safety RX-7W22 2W 700/800 Tetra
RX Series

Wireless Repeater Medium Power mBDA Series

Product Photo Name Power Bands System

mBDA 800E/850/900/1800/1900 GSM/UMTS/


mBDA-xx33 0.5/1/2 W
Outdoor AWS/2100/2600 LTE/CDMA
mBDA mBDA-RF-xx0 800E/850/900/1800/1900 GSM/UMTS/
0.5/1/2 W
Indoor 0 AWS/2100/2600 LTE/CDMA

Wireless Repeater Low Power Pico Series

Product Photo Name Power Bands System

Analog GSM/UMTS/
Sx-xx10 15/17 dBm 900/2100
Pico LTE/CDMA

Digital 15/17/20 800/850/900/1800/1900/ GSM/UMTS/


MP-xx32
Pico dBm 2100/2600 LTE/CDMA

Location System Series

Product Photo Name Power Bands Algorithm

Base
LB-2xxx 16/19dBm 2400 TDOA/RSSI
Station

Terminal LT-2xxx 16/17dBm 2400 TDOA/RSSI


Product Application Scenario
Comba solutions are effective point-to-point/point-to-multipoint distributed antenna system that provides effective coverage
enhancement. The Comba product offers service providers an optimal solution for multiple applications from a single building to a
campus, mega mall, or sports arena and beyond.

2
Product application Scenario 1: Mega (>10,000 m )

Large Stadiums Shopping Mall

Product Recommend: Product Recommend:


 DAS ComFlex AI  DAS ComFlex CI
 DAS ComFlex AM  DAS ComFlex AI

Air Port Railway / Metro

Product Recommend: Product Recommend:


 DAS ComFlex AI  DAS ComFlex CM
 DAS ComFlex AM  DAS ComFlex AM

Note:
DAS ComFlex CI: Page 19.
DAS ComFlex CM: Page 52.
DAS ComFlex AI: Page 64.
DAS ComFlex AM: Page 67.
2
Product application Scenario 2: Large (5,000 – 10,000 m )

Remote Village Campus

Product Recommend: Product Recommend:


 Wireless Repeater RX Series  DAS ComFlex CI
 Wireless Repeater RX Series

Enterprise & Manufacture Residential

Product Recommend: Product Recommend:


 Wireless Repeater mBDA Indoor Series  DAS ComFlex CI
 DAS ComFlex CI
 DAS ComFlex CM

Note:
DAS ComFlex CI: Page 19.
DAS ComFlex CM: Page 52.
Wireless Repeater RX Series: Page 76.
Wireless Repeater mBDA Indoor Series: Page 112.
Product application Scenario 3: Medium (1,000 – 5,000 m2)

Parking & Underground Tunnel

Product Recommend: Product Recommend:


 DAS ComFlex CI  DAS ComFlex CI
 Wireless Repeater RX Series  DAS ComFlex CM
 Wireless Repeater RX Series

Park Supermarket

Product Recommend: Product Recommend:


 Wireless Repeater RX Series  DAS ComFlex CI
 Wireless Repeater mBDA Series

Note:
DAS ComFlex CI: Page 19.
DAS ComFlex CM: Page 52.
Wireless Repeater RX Series: Page 76.
Wireless Repeater mBDA Series: Page 112.
Product application Scenario 4: small (< 1,000 m2)

Retail Store Restaurant

Product Recommend: Product Recommend:


 Wireless Repeater mBDA Series  Wireless Repeater mBDA Series
 Wireless Repeater Pico  Wireless Repeater Pico

Small Office Villa

Product Recommend: Product Recommend:


 Wireless Repeater mBDA Series  Wireless Repeater mBDA Series
 Wireless Repeater Pico  Wireless Repeater Pico

Note:
Wireless Repeater mBDA Series: Page 112.
Wireless Repeater Pico: Page 134.
Product application Scenario 5: Special Scenario 1

Public Safety Bridge Coverage

Product Recommend: Product Recommend:


 Wireless Repeater RX Series  Wireless Repeater mBDA Series
 Wireless Repeater Pico Series

Highway Coverage Sail Coverage

Product Recommend: Product Recommend:


 Wireless Repeater mBDA Series  Wireless Repeater mBDA Series
 Wireless Repeater Pico  Wireless Repeater Pico

Product application Scenario 6: Special Scenario 2

Mine Prison

Product Recommend: Product Recommend:


 Location System  Location System

Note:
Wireless Repeater RX Series: Page 76.
Wireless Repeater mBDA Series: Page 112.
Wireless Repeater Pico: Page 134.
Location System: Page 160.
ComFlex Series Distributed Antenna System
ComFlex-5H00(CI) 1W2W
Features
 Modularized Master Unit supports field upgrade and independent gain control.
 RF module supports both simplex and duplex.
 Compact slim Remote Unit for OPEX saving.
 Full operation bandwidth system supports multi-operator application.
 Supports all major technologies GSM, CDMA, WCDMA and LTE.
 Comply with 3GPP.
 Optical link auto gain control.
 Web based GUI for intelligent commissioning and configuration.

Product Description
The ComFlex series Distributed Antenna System is an RF over fiber solution that enhances a wireless network’s
coverage by extending cellular services from existing cell sites to an indoor environment. The system consists of the
Master Unit (MU) and low power Remote Unit (RU). The MU includes the Chassis, Power Supply Unit (PSU), Fibre
Optical Unit (FOU) and RF Unit (RFU). With a modular design, it can support up to 8 independent RF inputs and 8
Remote Units. The Remote Unit is designed with a compact and slim form factor for easy installation; it is an
integrated design which supports 3 independent bands, 850MHz, 1900MHz and 2600MHz.

This solution is an effective point-to-multipoint distributed antenna system that provides effective coverage
enhancement. The Comba Tri-Band DAS offers service providers an optimal solution for multiple applications from a
single building to a campus, mega mall, or sports arena and beyond.

Functional Block Diagram


LRU 1 LRU 2 LRU 8

SISO System …

(optional)
BTS DAS Tray

MIMO System
LRU 1A LRU 1B LRU 4A LRU 4B
BTS 1 (optional)
DAS Tray

BTS 2

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 19 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-4 / 1014
ComFlex-5H00 1W2W
Specifications
Optical
System 850MHz, 1900MHz, 2600MHz
Optical Fiber Single Mode
Optical Wavelength nm 1310, 1550 + WDM
Master Unit -4 to -2
Optical Output Power dBm
Remote Unit 3-5
Optical Return Loss dB > 50
Max. Optical Loss dB 6.5
Optical Automatic Gain Control dB 6.5
Fiber Connectors SC/APC
Maximum Remote Unit per Master Unit 8 (16 with FOU extension)

Electrical
850MHz 1900MHz 2600MHz
Uplink Frequency Range 824-849 1850-1910 2500-2570
MHz
Downlink Frequency Range 869-894 1930-1990 2620-2690
Operating Bandwidth MHz 25 60 70
Uplink Output Power dBm -25 -25 -25
Downlink Output Power dBm 30/33 30/33 30/33
Uplink Maximum gain dB 20 @ 1W; 23 @ 2W
Downlink Maximum gain dB 20 @ 1W; 23 @ 2W
ATT Adjustable Range(1dB step) dB MU: 0-40; RU: 0-15
Pass Band Ripple (p-p) dB ≤5 ≤6 ≤6
Spurious emission 3GPP TS 25.106 3GPP TS 25.106 3GPP TS 36.106
Uplink Noise Figure at Maximum
dB ≤6
Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max. Input RF Power at Master Unit dBm 30

Mechanical---MU
Chassis 178 x 482 x 360
Fiber Optical Unit 37 x 185 x 299
Dimensions, H x W x D mm
Per RF Unit 103 x 46 x 259
Power Supply Unit 140 x 63 x 400
Chassis 12
Fiber Optical Unit 2
Weight (approx.) kg
Per RF Unit 1
Power Supply Unit 2.5
Power Supply VAC 100-240/50-60Hz
Power Consumption (approx.) W 85
RF Connectors N-Female
Fiber Connectors SC/APC
o
Operating Temperature C 0 to +40
Operating Humidity ≤ 85%
Ingress protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 20 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-4 / 1014
ComFlex-5H00 1W2W
Specifications
Mechanical---LRU
1W 2W
Dimensions, H x W x D mm 680 x 260 x 180
Weight kg 25
Power Supply AC110/220V VAC 100-240/50-60Hz
Power Consumption W 120 150
RF Connectors N-Female
Fiber Connectors SC/APC
o
Operating Temperature C -40 to +55
Operating Humidity ≤ 95%
Ingress protection IP65
Enclosure Cooling Convection
Installation Type Wall

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 21 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-4 / 1014
ComFlex-5H00 1W2W
ComFlex Series Distributed Antenna System
ComFlex-5000(CI) 1W2W
Features
 Modularized Master Unit supports field upgrade and independent gain control.
 RF module supports both simplex and duplex.
 Compact slim Remote Unit for OPEX saving.
 Full operation bandwidth system supports multi-operator application.
 Supports all major technologies GSM, CDMA, WCDMA and LTE.
 Comply with 3GPP.
 Optical link auto gain control.
 Web based GUI for intelligent commissioning and configuration.

Product Description
The ComFlex series Distributed Antenna System is an RF over fiber solution that enhances a wireless network’s
coverage by extending cellular services from existing cell sites to an indoor environment. The system consists of the
Master Unit (MU) and low power Remote Unit (RU). The MU includes the Chassis, Power Supply Unit (PSU), Fibre
Optical Unit (FOU) and RF Unit (RFU). With a modular design, it can support up to 8 independent RF inputs and 8
Remote Units. The Remote Unit is designed with a compact and slim form factor for easy installation; it is an
integrated design which supports 3 independent bands, 1900MHz, AWS and AWS MIMO.

This solution is an effective point-to-multipoint distributed antenna system that provides effective coverage
enhancement. The Comba Tri-Band DAS offers service providers an optimal solution for multiple applications from a
single building to a campus, mega mall, or sports arena and beyond.

Functional Block Diagram

LRU 1 LRU 4
BTS 1 (optional)
DAS Tray

BTS 2

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 22 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-4 / 0415
ComFlex-5000 1W2W
Specifications
Optical
System 1900MHz, AWS, AWS MIMO
Optical Fiber Single Mode
Optical Wavelength nm 1310, 1550 + WDM
Master Unit -4 to -2
Optical Output Power dBm
Remote Unit 3 to 5
Optical Return Loss dB > 50
Max. Optical Loss dB 6.5
Optical Automatic Gain Control dB 6.5
Fiber Connectors SC/APC
Maximum Remote Unit per Master Unit 4 (8 with FOU extension)

Electrical
1900MHz AWS AWS MIMO
Uplink Frequency Range 1850-1910 1710-1755 1710-1755
MHz
Downlink Frequency Range 1930-1990 2110-2155 2110-2155
Operating Bandwidth MHz 60 45 45
Uplink Output Power dBm -25 -25 -25
Downlink Output Power dBm 30/33 30/33 30/33
Uplink Maximum gain dB 20 @ 1W; 23 @ 2W
Downlink Maximum gain dB 20 @ 1W; 23 @ 2W
ATT Adjustable Range(1dB step) dB MU: 0-40; RU: 0-15
Pass Band Ripple (p-p) dB ≤6 ≤6 ≤6
3GPP TS 25.106 3GPP TS 25.106
Spurious emission 3GPP TS 25.106
3GPP TS 36.106 3GPP TS 36.106
Uplink Noise Figure at Maximum
dB ≤6
Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max. Input RF Power at Master Unit dBm 30

Mechanical---MU
Chassis 178 x 482 x 360
Fiber Optical Unit 37 x 185 x 299
Dimensions, H x W x D mm
Per RF Unit 103 x 46 x 259
Power Supply Unit 140 x 63 x 400
Chassis 12
Fiber Optical Unit 2
Weight (approx.) kg
Per RF Unit 1
Power Supply Unit 2.5
Power Supply VAC 100-240/50-60Hz
Power Consumption (approx.) W 85
RF Connectors N-Female
Fiber Connectors SC/APC
o
Operating Temperature C 0 to +40
Operating Humidity ≤ 85%
Ingress protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 23 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-4 / 0415
ComFlex-5000 1W2W
Specifications
Mechanical---LRU
1W 2W
Dimensions, H x W x D mm 680 x 260 x 180
Weight kg 25
Power Supply AC110/220V VAC 100-240/50-60Hz
Power Consumption W 120 150
RF Connectors N-Female
Fiber Connectors SC/APC
o
Operating Temperature C -40 to +55
Operating Humidity ≤ 95%
Ingress protection IP65
Enclosure Cooling Convection
Installation Type Wall

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 24 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-4 / 0415
ComFlex-5000 1W2W
ComFlex 600 Series DAS
ComFlex-6100(CI) 1W
Features
 Industry’s first DAS system with superior PIM performance MINI-DIN RF connectors.
 Independent coupling port for uninterrupted network testing.
 Modular Master Unit supports flexible field upgrade and maintenance.
 Independent gain control for each RF source.
 High MTBF and low noise design with modular PSU and convection cooling.
 RF module supports both simplex and duplex.
 Compact, slim Remote Unit for OPEX saving.
 Supports multi-operator and mixed mode application.
 Optical link auto gain control.
 Web based GUI for intelligent commissioning and configuration.

Product Description
The ComFlex 600 series Distributed Antenna System is an RF over fiber solution that enhances a wireless network’s
coverage by extending cellular services from existing cell sites to an indoor environment. The system consists of the
Master Unit (MU) and Low power Remote Unit (RU). The MU includes the Chassis, Power Supply Unit (PSU), Fiber
Optical Unit (FOU) and RF Unit (RFU). With a modular design, it can support up to 8 independent RF inputs and 8
Remote Units. The Remote Unit is designed with a compact and slim form factor for easy installation; it is an
integrated design which supports 6 independent bands: 700MHz (lower ABC), 700MHz (upper C), 800MHz,
850MHz, 1900MHz, and AWS band.

This solution is an effective point-to-multipoint distributed antenna system that provides effective coverage
enhancement. The Comba Hex-Band DAS offers service providers an optimal solution for variable venue sizes such
as single buildings, office campuses, megamalls and sports arenas.

Functional Block Diagram

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 25 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 3-0-1 / 0514
ComFlex 6100 1W
Specifications
Optical
System 700MHz (lower ABC), 700MHz (upper C), 800MHz, 850MHz, 1900MHz, AWS
Optical Fiber Single Mode
Optical Wavelength nm 1310, 1550 + WDM
Master Unit -4 to -2
Optical Output Power dBm
Remote Unit 3-5
Optical Return Loss dB > 50
Max. Optical Loss dBo 6.5
Optical Automatic Gain Control dBo 6.5
Fiber Connectors SC/APC
Maximum Remote Unit per Master Unit 8 (16 with FOU extension)

Electrical
700MHz 800/850MHz 1900MHz AWS
Uplink Frequency Range 698-716/776-787 817-824/824-849 1850-1915 1710-1755
MHz
Downlink Frequency Range 728-746/746-757 862-869/869-894 1930-1995 2110-2155
Operating Bandwidth MHz 18/11 7/25 65 45
Uplink Output Power dBm -25 -25 -25 -25
Downlink Output Power dBm 30 30 30 30
Uplink Maximum Gain dB 20
Downlink Maximum Gain dB 20
ATT Adjustable Range(1dB
dB MU: 0-40, RU: 0-30
step)
Pass Band Ripple (p-p) dB ≤4 ≤6 ≤6 ≤4
3GPP TS 25.106
3GPP TS 36.106 3GPP TS 36.106 3GPP TS 25.106
Spurious Emission 3GPP TS 36.106
FCC FCC FCC
FCC
Uplink Noise Figure at
dB ≤6
Maximum Gain
System Delay sec ≤3
VSWR ≤ 1.5
Max. Input RF Power at
dBm 30
Master Unit

Mechanical---MU
Chassis 7” x 19” x 15.7” (178 x 482 x 400)
Fiber Optical Unit 1.5” x 7.3” x 11.8” (37 x 185 x 299)
Dimensions, H x W x D in(mm)
Per RF Unit 4.1” x 1.8” x 10.2” (103 x 46 x 259)
Power Supply Unit 5.5” x 2.5” x 15.7” (140 x 63 x 400)
Chassis 24.3 (11)
Fiber Optical Unit 4.4 (2)
Weight (approx.) lb(kg)
Per RF Unit 2.2 (1)
Power Supply Unit 5.5 (2.5)
Power Supply VAC 100-240/50-60Hz
Power Consumption (approx.) W 85
RF Connectors Mini DIN-Female
QMA-Female
Coupling Port Connectors
(For UL related testing, coupling value: -5dB)
Fiber Connectors SC/APC
o
Operating Temperature C 0 to 40
Operating Humidity ≤ 85%
Ingress Protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 26 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 3-0-1 / 0514
ComFlex 6100 1W
Specifications
Mechanical---RU
Remote Unit 23.6” x 9.8” x 5.9” (600 x 250 x 150)
Dimensions, H x W x D in(mm)
Power Supply Unit 16.1” x 4.4” x 3.5” (408 x 111 x 90)
Remote Unit 44.1 (20)
Weight (approx.) lb(kg)
Power Supply Unit 7.7 (3.5)
Power Supply VAC 100-240/50-60Hz
Power Consumption (approx.) W 120
RF Connectors Mini DIN-Female
QMA-Female
Coupling Port Connectors (For DL related testing, coupling value: -45dB:700&850&800;
-35dB:1900&AWS)
QMA-Female
RF Expansion Port
(1 x TX_EXT + 1 x RX_EXT)
Fiber Connectors SC/APC
o
Operating Temperature C -20 to 50
Operating Humidity ≤ 85%
Ingress Protection IP30
Enclosure Cooling Convection
Installation Type Wall and Pole

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 27 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 3-0-1 / 0514
ComFlex 6100 1W
ComFlex Series Distributed Antenna System
ComFlex-4500(CI) 2W5W
Features
 Modularized Master Unit supports field upgrade and independent gain control.
 RF module supports both simplex and duplex.
 Compact slim Remote Unit for OPEX saving.
 Full operation bandwidth system supports multi-operator application.
 Supports all major technologies GSM, CDMA, WCDMA and LTE.
 Optical link auto gain control.
 Web based GUI for intelligent commissioning and configuration.

Product Description
The ComFlex series Distributed Antenna System is an RF over fiber solution that enhances a wireless network’s
coverage by extending cellular services from existing cell sites to an indoor environment. The system consists of the
Master Unit (MU) and medium power Remote Unit (RU). The MU includes the Chassis, Power Supply Unit (PSU),
Fibre Optical Unit (FOU) and RF Unit (RFU). With a modular design, it can support up to 8 independent RF inputs
and 8 Remote Units. The Remote Unit is designed with a compact and slim form factor for easy installation; it is an
integrated design which supports 4 independent bands, 900MHz, 1800MHz, 2100MHz and 1800MIMO.

This solution is an effective point-to-multipoint distributed antenna system that provides effective coverage
enhancement. The Comba Quad-Band DAS offers service providers an optimal solution for multiple applications
from a single building to a campus, mega mall, or sports arena and beyond.

Functional Block Diagram

MIMO System
RU A1 RU B1 RU A4 RU B4
BTS 1 (optional)
DAS Tray

BTS 2

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 28 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-1 / 1015
ComFlex-4500 2W5W
Specifications
Optical
System 850MHz, 1800MHz, 2100MHz, 2600MHz
Optical Fiber Single Mode
Optical Wavelength nm 1310, 1550 + WDM
Master Unit -4 to -2
Optical Output Power dBm
Remote Unit 3 to 5
Optical Return Loss dB > 50
Max. Optical Loss dBo 6.5
Optical Automatic Gain Control dBo 6.5
Fiber Connectors SC/APC
Maximum Remote Unit per Master Unit 8 (16 with FOU expansion)

Electrical
850MHz 1800MHz 2100MHz 2600MHz
Uplink Frequency Range 824-849 1710-1785 1920-1980 2500-2570
MHz
Downlink Frequency Range 869-894 1805-1880 2110-2170 2620-2690
Operating Bandwidth MHz 25 75 60 70
Uplink Output Power dBm -20 -20 -20 -20
Downlink Output Power dBm 33/37 33/37 33/37 33/37
Uplink Maximum gain dB 23@2W, 27@5W
Downlink Maximum gain dB 23@2W, 27@5W
ATT Adjustable Range(1dB
dB MU: 0-40, RU: 0-30
step)
Pass Band Ripple (p-p) dB ≤4 ≤5 ≤5 ≤5
Spurious emission 3GPP TS 25.106 3GPP TS 36.106 3GPP TS 25.106 3GPP TS 36.106
Uplink Noise Figure at
dB ≤6
Maximum Gain
System Delay sec ≤3
VSWR ≤ 1.5
Max. Input RF Power at
dBm 30
Master Unit
MTBF hr >100,000

Mechanical---MU
Chassis 178 x 482 x 360
Fiber Optical Unit 37 x 185 x 299
Dimensions, H x W x D mm
Per RF Unit 103 x 46 x 259
Power Supply Unit 140 x 63 x 400
Chassis 11
Fiber Optical Unit 2
Weight (approx.) kg
Per RF Unit 1
Power Supply Unit 2.5
Power Supply VAC 100-240/50-60Hz
Power Consumption (approx.) W 85
RF Connectors N-Female
Fiber Connectors SC/APC
o
Operating Temperature C 0 to +40
Operating Humidity ≤ 85%
Ingress protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 29 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-1 / 1015
ComFlex-4500 2W5W
Specifications
Mechanical---MRU 2W 5W
Remote Unit 660 x 250 x 160
Dimensions, H x W x D mm
Power Supply Unit 408 x 111 x 90
Remote Unit 25
Weight (approx.) kg
Power Supply Unit 3.5
Power Supply VAC 100-240/50-60Hz
Power Consumption (approx.) W 180 200
RF Connectors N-Female
Fiber Connectors SC/APC
o
Operating Temperature C -20 to +50
Operating Humidity ≤ 85%
Ingress protection IP30
Enclosure Cooling Convection
Installation Type Wall/Pole

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 30 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-1 / 1015
ComFlex-4500 2W5W
ComFlex Series Distributed Antenna System
ComFlex-4100(CI) 5W
Features
 Modularized Master Unit supports field upgrade and independent gain control.
 RF module supports both simplex and duplex.
 Compact slim Remote Unit for OPEX saving.
 Full operation bandwidth system supports multi-operator application.
 Supports all major technologies GSM, CDMA, WCDMA and LTE.
 Comply with 3GPP.
 Optical link auto gain control.
 Web based GUI for intelligent commissioning and configuration.

Product Description
The ComFlex series Distributed Antenna System is an RF over fiber solution that enhances a wireless
network’s coverage by extending cellular services from existing cell sites to an indoor environment. The system
consists of the Master Unit (MU) and medium power Remote Unit (RU). The MU includes the Chassis, Power
Supply Unit (PSU), Fiber Optical Unit (FOU) and RF Unit (RFU). With a modular design, it can support up to 8
independent RF inputs and 8 Remote Units. The Remote Unit is designed with a compact and slim form factor
for easy installation; it is an integrated design which supports 4 independent bands 900MHz, 1800MHz,
2100MHz and 2600MHz.

This solution is an effective point-to-multipoint distributed antenna system that provides effective coverage
enhancement. The Comba DAS offers service providers an optimal solution for variable venue sizes such as
single buildings, office campuses, mega malls and sports arenas.

Functional Block Diagram


RU 1 RU 2 RU 8

SISO System …

(optional)
BTS DAS Tray

MIMO System
RU 1A RU 1B RU 4A RU 4B
BTS 1 (optional)
DAS Tray

BTS 2

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers’ requirements. Page 31 of 175
DS-Control: 0-0-2 / 1016
ComFlex-4100(CI) 5W
Specifications
Optical
System 900MHz, 1800MHz, 2100MHz, 2600MHz
Optical Fiber Single Mode
Optical Wavelength nm 1310, 1550 + WDM
Master Unit -4 to -2
Optical Output Power dBm
Remote Unit 3 to 5
Optical Return Loss dB > 50
Max. Optical Loss dB 6.5
Optical Automatic Gain Control dB 6.5
Fiber Connectors SC/APC
Maximum Remote Unit per Master Unit 16 (with FOU extension)

Electrical
900MHz 1800MHz 2100MHz 2600MHz
Uplink Frequency Range 880-915 1710-1785 1920-1980 2500-2570
MHz
Downlink Frequency Range 925-960 1805-1880 2110-2170 2620-2690
Operating Bandwidth MHz 35 75 60 70
Uplink Output Power dBm -20 -20 -20 -20
Downlink Output Power dBm 37 37 37 37
Uplink Maximum gain dB 27
Downlink Maximum gain dB 27
ATT Adjustable Range (1dB step) dB MU: 0-40, RU: 0-30
Pass Band Ripple (p-p) dB ≤5 ≤6 ≤5 ≤6
3GPP TS25.106 3GPP TS25.106
Spurious emission 3GPP TS25.106 3GPP TS 36.106
3GPP TS 36.106 3GPP TS 36.106
Uplink Noise Figure at Maximum Gain dB ≤6
System Delay sec ≤3
VSWR ≤ 1.5
Max. Input RF Power at Master Unit dBm 30

Mechanica---MU
Chassis 178 x 482 x 360
Fiber Optical Unit 37 x 185 x 299
Dimensions, H x W x D mm
RF Unit 103 x 46 x 259
Power Supply Unit 140 x 63 x 400
Chassis 12
Fiber Optical Unit 2
Weight (approx.) kg
RF Unit 1
Power Supply Unit 2.5
Power Supply VAC 100-240/50-60Hz
Power Consumption (approx.) W 85
RF Connectors N-Female
Fiber Connectors SC/APC
o
Operating Temperature C 0 to +40
Operating Humidity ≤ 85%
Ingress protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers’ requirements. Page 32 of 175
DS-Control: 0-0-2 / 1016
ComFlex-4100(CI) 5W
Specifications
Mechanical---MRU
Remote Unit 660 x 250 x 160
Dimensions, H x W x D mm
Power Supply Unit 408 x 111 x 90
Remote Unit 25
Weight (approx.) kg
Power Supply Unit 3.5
Power Supply VAC 100-240/50-60Hz
Power Consumption (approx.) W 200
RF Connectors N-Female
Fiber Connectors SC/APC
o
Operating Temperature C -20 to +50
Operating Humidity ≤ 85%
Ingress protection IP30
Enclosure Cooling Convection
Installation Type Wall/Pole

License Note
License Code 900MHz 1800MHz 2100MHz 2600MHz
N/A √ √ √ √

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers’ requirements. Page 33 of 175
DS-Control: 0-0-2 / 1016
ComFlex-4100(CI) 5W
ComFlex Series Distributed Antenna System
ComFlex-5200(CI) 20W40W
Features
 Modularized Master Unit supports field upgrade and independent gain control.
 High MTBF with modular PSU and convection cooling.
 RF module supports both simplex and duplex.
 Compact slim Remote Unit for OPEX saving.
 Full operation bandwidth system supports multi-operator application.
 Supports all major technologies GSM, CDMA, WCDMA and LTE.
 Independent coupling port of MU for uninterrupted network testing.
 Optical link auto gain control.
 Web based GUI for intelligent commissioning and configuration.

Product Description
The ComFlex series Distributed Antenna System is an RF over fiber solution that enhances a wireless network’s
coverage by extending cellular services from existing cell sites to an indoor environment. The system consists of the
Master Unit (MU) and Remote Unit (RU). The MU includes the MU Rack, Power Supply Unit (PSU), Fiber Optical
Unit (FOU) and RF Unit (RFU). With a modular design, it can support up to 8 independent RF inputs and 8 Remote
Units. The Remote Unit is designed with a compact and slim form factor for easy installation; it is an integrated
design which supports 3 independent bands, 900MH, 1800MHz and 2100MHz.

This solution is an effective point-to-multipoint distributed antenna system that provides effective coverage
enhancement. The Comba Tri-Band DAS offers service providers an optimal solution for multiple applications from a
single building to a campus, mega mall, or sports arena and beyond.

Functional Block Diagram


HRU 1 HRU 2 HRU 8

SISO System …

(optional)
BTS DAS Tray

MIMO System
HRU 1A HRU 1B HRU 4A HRU 4B
BTS 1 (optional)
DAS Tray

BTS 2

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 34 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-2 / 0115
ComFlex-5200 20W40W
Specifications
Optical
System 900MHz, 1800MHz, 2100MHz
Optical Fiber Single Mode
Optical Wavelength nm 1310, 1550 + WDM
Master Unit -4 to -2
Optical Output Power dBm
Remote Unit 3-5
Optical Return Loss dB > 50
Max. Optical Loss dB 6.5
Optical Automatic Gain Control dB 6.5
Fiber Connectors SC/APC

Electrical
900MHz 1800MHz 2100MHz
Uplink Frequency Range 880-915 1710-1785 1920-1980
MHz
Downlink Frequency Range 925-960 1805-1880 2110-2170
Operating Bandwidth MHz 35 75 60
Uplink Output Power dBm -20 -20 -20
Downlink Output Power dBm 43/46 43/46 43/46
Uplink Maximum gain dB 33
Downlink Maximum gain dB 35@20W, 38@40W
ATT Adjustable Range (1dB step) dB MU: 0-40, RU: 0-30
Pass Band Ripple (p-p) dB ≤5 ≤6 ≤6
3GPP TS 25.106
Spurious emission 3GPP TS 25.106 3GPP TS 25.106
3GPP TS 36.106
Uplink Noise Figure at Maximum Gain dB ≤5
System Delay sec ≤2
VSWR ≤ 1.5
Max. Input RF Power at Master Unit dBm 30

Mechanical---MU
Chassis 178 x 482 x 360
Fiber Optical Unit 37 x 185 x 299
Dimensions, H x W x D mm
Per RF Unit 103 x 46 x 259
Power Supply Unit 140 x 63 x 400
Chassis 11
Fiber Optical Unit 2
Weight (approx.) kg
Per RF Unit 1
Power Supply Unit 2.5
Power Supply VAC 100-240/50-60Hz
Power Consumption (approx.) W 85
RF Connectors N-Female
Fiber Connectors SC/APC
o
Operating Temperature C 0 to +40
Operating Humidity ≤ 85%
Ingress protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 35 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-2 / 0115
ComFlex-5200 20W40W
Specifications
Mechanical---HRU
20W 40W
Dimensions, H x W x D mm 1270 x 236 x 236
Weight (approx.) kg 49
Power Supply AC110/220V VAC 100-240/50-60Hz
Power Consumption (approx.) W 1000 1200
RF Connectors 3 x 7/16 DIN-F
Fiber Connectors SC/APC
o
Operating Temperature C -40 to +55
Operating Humidity ≤ 95%
Ingress protection IP65
Enclosure Cooling Fan
Installation Type Wall/Pole

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 36 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-2 / 0115
ComFlex-5200 20W40W
ComFlex Series Distributed Antenna System
ComFlex-5P00(CI) 20W
Features
 Modularized Master Unit supports field upgrade and independent gain control.
 High MTBF with modular PSU and convection cooling.
 RF module supports both simplex and duplex.
 Compact slim Remote Unit for OPEX saving.
 Full operation bandwidth system supports multi-operator application.
 Supports all major technologies GSM, CDMA, WCDMA and LTE.
 Independent coupling port of MU for uninterrupted network testing.
 Optical link auto gain control.
 Web based GUI for intelligent commissioning and configuration.

Product Description
The ComFlex series Distributed Antenna System is an RF over fiber solution that enhances a wireless network’s
coverage by extending cellular services from existing cell sites to an indoor environment. The system consists of the
Master Unit (MU) and Remote Unit (RU). The MU includes the MU Rack, Power Supply Unit (PSU), Fiber Optical
Unit (FOU) and RF Unit (RFU). With a modular design, it can support up to 8 independent RF inputs and 8 Remote
Units. The Remote Unit is designed with a compact and slim form factor for easy installation; it is an integrated
design which supports 3 independent bands, 1800MH, 2100MHz and 2600MHz.

This solution is an effective point-to-multipoint distributed antenna system that provides effective coverage
enhancement. The Comba Tri-Band DAS offers service providers an optimal solution for multiple applications from a
single building to a campus, mega mall, or sports arena and beyond.

Functional Block Diagram


HRU 1 HRU 2 HRU 8

SISO System …

(optional)
BTS DAS Tray

MIMO System
HRU 1A HRU 1B HRU 4A HRU 4B
BTS 1 (optional)
DAS Tray

BTS 2

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 37 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-2/ 1016
ComFlex-5P00(CI) 20W SIN
Specifications
Optical
System 1800MHz, 2100MHz, 2600MHz
Optical Fiber Single Mode
Optical Wavelength nm 1310, 1550 + WDM
Master Unit -4 to -2
Optical Output Power dBm
Remote Unit 3.0 to 5.0
Optical Return Loss dB > 50
Max. Optical Loss dB 6.5
Optical Automatic Gain Control dB 6.5
Fiber Connectors SC/APC
Maximum Remote Unit per Master Unit 16 (with FOU extension)

Electrical
1800MHz 2100MHz 2600MHz
Uplink Frequency Range 1710-1785 1920-1980 2500-2570
MHz
Downlink Frequency Range 1805-1880 2110-2170 2620-2690
Operating Bandwidth MHz 75 60 70
Uplink Output Power dBm -20 -20 -20
Downlink Output Power dBm 43 43 43
Uplink Maximum gain dB 33
Downlink Maximum gain dB 35
ATT Adjustable Range (1dB step) dB MU: 0-40; RU: 0-30
Pass Band Ripple (p-p) dB ≤6 ≤6 ≤6
Spurious emission 3GPP TS 36.106 3GPP TS 25.106 3GPP TS 36.106
Uplink Noise Figure at Maximum Gain dB ≤5
System Delay sec ≤2
VSWR ≤ 1.5
Max. Input RF Power at Master Unit dBm 30

Mechanical---MU
Chassis 178 x 482 x 360
Fiber Optical Unit 37 x 185 x 299
Dimensions, H x W x D mm
Per RF Unit 103 x 46 x 259
Power Supply Unit 140 x 63 x 400
Chassis 12
Fiber Optical Unit 2
Weight (approx.) kg
Per RF Unit 1
Power Supply Unit 2.5
Power Supply VAC 100-240/50-60Hz
Power Consumption (approx.) W 85
RF Connectors N-Female
Fiber Connectors SC/APC
o
Operating Temperature C 0 to +40
Operating Humidity ≤ 85%
Ingress protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 38 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-2/ 1016
ComFlex-5P00(CI) 20W SIN
Specifications
Mechanical---HRU
20W
Dimensions, H x W x D mm 1270 x 236 x 236
Weight (approx.) kg 49
Power Supply VAC 100-240/50-60Hz
Power Consumption (approx.) W 1100
RF Connectors Din-Female (1 x TX and 1 x RX)
Fiber Connectors SC/APC
o
Operating Temperature C -40 to +55
Operating Humidity ≤ 95%
Ingress protection IP65
Enclosure Cooling Fan
Installation Type Wall/Pole

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 39 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-2/ 1016
ComFlex-5P00(CI) 20W SIN
ComFlex Series Distributed Antenna System
ComFlex-5000(CI) 20W40W
Features
 Modularized Master Unit supports field upgrade and independent gain control.
 RF module supports both simplex and duplex.
 Compact slim Remote Unit for OPEX saving.
 Full operation bandwidth system supports multi-operator application.
 Supports all major technologies GSM, CDMA, WCDMA and LTE.
 Comply with 3GPP.
 Optical link auto gain control.
 Web based GUI for intelligent commissioning and configuration.

Product Description
The ComFlex series Distributed Antenna System is an RF over fiber solution that enhances a wireless network’s
coverage by extending cellular services from existing cell sites to an indoor environment. The system consists of the
Master Unit (MU) and high power Remote Unit (RU). The MU includes the Chassis, Power Supply Unit (PSU), Fibre
Optical Unit (FOU) and RF Unit (RFU). With a modular design, it can support up to 8 independent RF inputs and 8
Remote Units. The Remote Unit is designed with a compact and slim form factor for easy installation; it is an
integrated design which supports 3 independent bands, 1900MHz, AWS, and AWS MIMO.

This solution is an effective point-to-multipoint distributed antenna system that provides effective coverage
enhancement. The Comba DAS offers service providers an optimal solution for multiple applications from a single
building to a campus, mega mall, or sports arena and beyond.

Functional Block Diagram

HRU 1 HRU 4

BTS 1 (optional)
DAS Tray

BTS 2

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 40 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-3 / 0415
ComFlex-5000 20W40W
Specifications
Optical
System 1900MHz, AWS, AWS
Optical Fiber Single Mode
Optical Wavelength nm 1310, 1550 + WDM
Master Unit -4 to -2
Optical Output Power dBm
Remote Unit 3.0 to 5.0
Optical Return Loss dB > 50
Max. Optical Loss dB 6.5
Optical Automatic Gain Control dB 6.5
Fiber Connectors SC/APC
Maximum Remote Unit per Master Unit 4 (8 with FOU extension)

Electrical
1900MHz AWS AWS
Uplink Frequency Range 1850-1910 1710-1755 1710-1755
MHz
Downlink Frequency Range 1930-1990 2110-2155 2110-2155
Operating Bandwidth MHz 60 45 45
Uplink Output Power dBm -20 -20 -20
Downlink Output Power dBm 43/46 43/46 43/46
Uplink Maximum gain dB 33
Downlink Maximum gain dB 35 @ 20W; 38 @ 40W
ATT Adjustable Range(1dB step) dB MU: 0-40; HRU: 0-30
Pass Band Ripple (p-p) dB ≤6 ≤5 ≤5
3GPP TS 25.106 3GPP TS 25.106
Spurious emission 3GPP TS 25.106
3GPP TS 36.106 3GPP TS 36.106
Uplink Noise Figure at Maximum
dB ≤6
Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max. Input RF Power at Master Unit dBm 30

Mechanical---MU
Chassis 178 x 482 x 360
Fiber Optical Unit 37 x 185 x 299
Dimensions, H x W x D mm
Per RF Unit 103 x 46 x 259
Power Supply Unit 140 x 63 x 400
Chassis 12
Fiber Optical Unit 2
Weight (approx.) kg
Per RF Unit 1
Power Supply Unit 2.5
Power Supply VAC 100-240/50-60Hz
Power Consumption (approx.) W 85
RF Connectors N-Female
Fiber Connectors SC/APC
o
Operating Temperature C 0 to +40
Operating Humidity ≤ 85%
Ingress protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 41 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-3 / 0415
ComFlex-5000 20W40W
Specifications
Mechanical---HRU
20W 40W
Dimensions, H x W x D mm 1270 x 236 x 236
Weight (appr.) kg 49
AC110/220V VAC 100-240/50-60Hz
Power Supply
DC-48 VDC -40 to -58
Power Consumption (appr.) W 1100 1250
RF Connectors D-Female x 3
Fiber Connectors SC/APC
o
Operating Temperature C -40 to +55
Operating Humidity ≤ 95%
Ingress protection IP65
Enclosure Cooling Convection
Installation Type Wall/Pole

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 42 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-3 / 0415
ComFlex-5000 20W40W
ComFlex Series Distributed Antenna System
ComFlex-4500(CI) 10W20W
Features
 Independent coupling port for uninterrupted network testing.
 Modularized Master Unit supports flexible field upgrade and maintenance.
 Independent gain control for each RF source.
 High MTBF and low noise design with modular PSU and convection cooling.
 RF module supports both simplex and duplex.
 IP65 weatherproof RU with built-in surge protector.
 Supports multi-operator and mix mode application.
 Optical link auto gain control.
 Web based GUI for intelligent commissioning and configuration.

Product Description
The ComFlex series Distributed Antenna System is an RF over fiber solution that enhances a wireless network’s
coverage by extending cellular services from existing cell sites to an indoor environment. The system consists of the
Master Unit (MU) and high power Remote Unit (RU). The MU includes the Chassis, Power Supply Unit (PSU), Fibre
Optical Unit (FOU) and RF Unit (RFU). With a modular design, it can support up to 8 independent RF inputs and 8
Remote Units. The Remote Unit is designed with a compact and slim form factor for easy installation; it is an
integrated design which supports 4 independent bands, 850MHz, 1800MHz, 2100MHz and 2600MHz.

This solution is an effective point-to-multipoint distributed antenna system that provides flexible and scalable
solution of multi-band, multi-operator coverage extension applications, such as citywide enhancement, highway,
canyons, campus, underground tunnels, airports, convention centres, etc.

Functional Block Diagram


RU 1 RU 2 RU 8

SISO System …

(optional)
BTS DAS Tray

MIMO System
RU 1A RU 1B RU 4A RU 4B
BTS 1 (optional)
DAS Tray

BTS 2

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 43 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-5 /0715
ComFlex-4500 10W20W
Specifications
Optical
System 850MHz, 180MHz, 2100MHz, 2600MHz
Optical Fiber Single Mode
Optical Wavelength nm 1310, 1550 + WDM
Master Unit -4 to -2
Optical Output Power dBm
Remote Unit 3 to 5
Optical Return Loss dB > 50
Max. Optical Loss dB 6.5
Optical Automatic Gain Control dB 6.5
Fiber Connectors SC/APC
Maximum Remote Unit per Master Unit 8 (16 with FOU extension)

Electrical
850MHz 1800MHz 2100MHz 2600MHz
Uplink Frequency Range 824-849 1710-1785 1920-1980 2500-2570
MHz
Downlink Frequency Range 869-894 1805-1880 2110-2170 2620-2690
Operating Bandwidth MHz 25 75 60 70
Uplink Output Power dBm -20 -20 -20 -20
Downlink Output Power dBm 40/43 40/43 40/43 40/43
Uplink Maximum gain dB 32@10W, 33 @20W
Downlink Maximum gain dB 32@10W, 35 @20W
ATT Adjustable Range(1dB
dB MU: 0-40, RU: 0-30
step)
Pass Band Ripple (p-p) dB ≤5 ≤6 ≤6 ≤6
Spurious emission 3GPP TS 25.106 3GPP TS 36.106 3GPP TS 25.106 3GPP TS 36.106
Uplink Noise Figure at
dB ≤6
Maximum Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max. Input RF Power at Master
dBm 30
Unit
MTBF hr >100,000

Mechanical---MU
Chassis 178 x 482 x 360
Fiber Optical Unit 37 x 185 x 299
Dimensions, H x W x D mm
Per RF Unit 103 x 46 x 259
Power Supply Unit 140 x 63 x 400
Chassis 11
Fiber Optical Unit 2
Weight (approx.) kg
Per RF Unit 1
Power Supply Unit 2.5
Power Supply VAC 100-240/50-60Hz
Power Consumption (approx.) W 85
RF Connectors N-Female
Fiber Connectors SC/APC
o
Operating Temperature C 0 to +40
Operating Humidity ≤ 85%
Ingress protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 44 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-5 /0715
ComFlex-4500 10W20W
Specifications
Mechanical---RU
10W 20W
Dimensions, H x W x D mm 1350 x 315 x 225
Weight (approx.) kg 70
AC110/220V VAC 100-240/50-60Hz
Power Supply
DC-48 VDC -40 to -58
Power Consumption (approx.) W 850 1100
RF Connectors DIN-Female
Fiber Connectors SC/APC
o
Operating Temperature C -40 to +70
Operating Humidity ≤ 95%
Ingress protection IP65
Enclosure Cooling Fan
Installation Type Wall/Pole

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 45 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-5 /0715
ComFlex-4500 10W20W
ComFlex Series Distributed Antenna System
ComFlex-4C00(CI) 20W40W
Features
 Modularized Master Unit supports flexible field upgrade and maintenance.
 Independent gain control for each RF source.
 RF module supports both simplex and duplex.
 IP65 weatherproof RU with built-in surge protector.
 Supports multi-operator and mix mode application.
 Optical link auto gain control.
 Web based GUI for intelligent commissioning and configuration.
 Supports FOU expansion.

Product Description
The ComFlex series Distributed Antenna System is an RF over fiber solution that enhances a wireless network’s
coverage by extending cellular services from existing cell sites to an indoor environment. The system consists of the
Master Unit (MU) and High power Remote Unit (RU). The MU includes the Chassis, Power Supply Unit (PSU), Fibre
Optical Unit (FOU) and RF Unit (RFU). With a modular design, it can support up to 8 independent RF inputs and 8
Remote Units. The Remote Unit is designed with a compact and slim form factor for easy installation; it is an
integrated design which supports 4 independent bands, 850MHz, 1900MHz, AWS and AWS MIMO band.

This solution is an effective point-to-multipoint distributed antenna system that provides effective coverage
enhancement. The Comba DAS offers service providers an optimal solution for multiple applications from a single
building to a campus, mega mall, or sports arena and beyond.

Functional Block Diagram

MIMO System
HRU 1 HRU 4
BTS 1 (optional)
DAS Tray

BTS 2

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 46 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-2 / 0615
ComFlex-4C00 20W40W
Specifications
Optical
System 850MHz, 1900MHz, AWS, AWS MIMO
Optical Fiber Single Mode
Optical Wavelength nm 1310, 1550 + WDM
Master Unit -4 to -2
Optical Output Power dBm
Remote Unit 3.0 to 5.0
Optical Return Loss dB > 50
Max. Optical Loss dB 6.5
Optical Automatic Gain Control dB 6.5
Maximum Remote Unit per Master Unit 4 (8 with FOU extension)

Electrical
850MHz 1900MHz AWS AWS
Uplink Frequency Range 824-849 1850-1910 1710-1755 1710-1755
MHz
Downlink Frequency Range 869-894 1930-1990 2110-2155 2110-2155
Operating Bandwidth MHz 25 60 45 45
Uplink Output Power dBm -20 -20 -20 -20
Downlink Output Power dBm 43/46 43/46 43/46 43/46
Uplink Maximum gain dB 33
Downlink Maximum gain dB 35@ 20W, 38@40W
ATT Adjustable Range(1dB
dB MU: 0-40, RU: 0-30
step)
Pass Band Ripple (p-p) dB ≤5 ≤6 ≤5 ≤5
Spurious emission 3GPP TS 25.106 3GPP TS 25.106 3GPP TS 25.106 3GPP TS 25.106
Uplink Noise Figure at
dB ≤6
Maximum Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max. Downlink Input Power dBm 30

Mechanical---MU
Chassis 178 x 482 x 360
Fiber Optical Unit 37 x 185 x 299
Dimensions, H x W x D mm
Per RF Unit 103 x 46 x 259
Power Supply Unit 140 x 63 x 400
Chassis 11
Fiber Optical Unit 2
Weight (approx.) kg
Per RF Unit 1
Power Supply Unit 2.5
Power Supply VAC 100-240/50-60Hz
Power Consumption (approx.) W 85
RF Connectors N-Female
Fiber Connectors SC/APC
o
Operating Temperature C 0 to 40
Operating Humidity ≤ 85%
Ingress protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 47 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-2 / 0615
ComFlex-4C00 20W40W
Specifications
Mechanical---HRU
Dimensions, H x W x D mm 1350 x 225 x 315
Weight (approx.) kg 70
AC110/220V VAC 100-240/47-63Hz
Power Supply
DC-48 VDC -58 to -40
Power Consumption (approx.) W 1350
RF Connectors DIN-Female
Fiber Connectors SC/APC
o
Operating Temperature C -40 to +70
Operating Humidity ≤ 95%
Ingress protection IP65
Enclosure Cooling Fan
Installation Type Wall/Pole

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 48 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-2 / 0615
ComFlex-4C00 20W40W
ComFlex Series Distributed Antenna System
ComFlex-4100(CI) 40W
Features
 Independent coupling port for uninterrupted network testing.
 Modularized Master Unit supports flexible field upgrade and maintenance.
 Independent gain control for each RF source.
 High MTBF and low noise design with modular PSU and convection cooling.
 RF module supports both simplex and duplex.
 IP65 weatherproof RU with built-in surge protector.
 Supports multi-operator and mix mode application.
 Optical link auto gain control.
 Web based GUI for intelligent commissioning and configuration.

Product Description
The ComFlex series Distributed Antenna System is an RF over fiber solution that enhances a wireless network’s
coverage by extending cellular services from existing cell sites to an indoor environment. The system consists of the
Master Unit (MU) and high power Remote Unit (RU). The MU includes the Chassis, Power Supply Unit (PSU), Fibre
Optical Unit (FOU) and RF Unit (RFU). With a modular design, it can support up to 8 independent RF inputs and 8
Remote Units. The Remote Unit is designed with a compact and slim form factor for easy installation; it is an
integrated design which supports 4 independent bands, 850MHz, 1800MHz, 2100MHz and 2600MHz.

This solution is an effective point-to-multipoint distributed antenna system that provides flexible and scalable
solution of multi-band, multi-operator coverage extension applications, such as citywide enhancement, highway,
canyons, campus, underground tunnels, airports, convention centres, etc.

Functional Block Diagram


HRU 1 HRU 2 HRU 8

SISO System …

(optional)
BTS DAS Tray

MIMO System
HRU 1A HRU 1B HRU 4A HRU 4B
BTS 1 (optional)
DAS Tray

BTS 2

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 49 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-3/ 1216
ComFlex-4100 40W
Specifications
Optical
System 900MHz, 1800MHz, 2100MHz, 2600MHz
Optical Fiber Single Mode
Optical Wavelength nm 1310, 1550 + WDM
Master Unit -4 to -2
Optical Output Power dBm
Remote Unit 3 to 5
Optical Return Loss dB > 50
Max. Optical Loss dB 6.5
Optical Automatic Gain Control dB 6.5
Fiber Connectors SC/APC
Maximum Remote Unit per Master Unit 8 (16 with FOU extension)

Electrical
900MHz 1800MHz 2100MHz 2600MHz
Uplink Frequency Range 880-915 1710-1785 1920-1980 2500-2570
MHz
Downlink Frequency Range 925-960 1805-1880 2110-2170 2620-2690
Operating Bandwidth MHz 35 75 60 70
Uplink Output Power dBm -20 -20 -20 -20
Downlink Output Power dBm 46 46 46 43
Uplink Maximum gain dB 38
Downlink Maximum gain dB 38
ATT Adjustable Range(1dB
dB MU: 0-40, RU: 0-30
step)
Pass Band Ripple (p-p) dB ≤5 ≤6 ≤5 ≤5
Spurious emission 3GPP TS 25.106 3GPP TS 36.106 3GPP TS 25.106 3GPP TS 36.106
Uplink Noise Figure at
dB ≤6
Maximum Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max. Input RF Power at
dBm 30
Master Unit

Mechanical---MU
Chassis 178 x 482 x 360
Fiber Optical Unit 37 x 185 x 299
Dimensions, H x W x D mm
Per RF Unit 103 x 46 x 259
Power Supply Unit 140 x 63 x 360
Chassis 11
Fiber Optical Unit 2
Weight (approx.) kg
Per RF Unit 1
Power Supply Unit 2.5
Power Supply VAC 100-240/50-60Hz
Power Consumption (approx.) W 85
RF Connectors N-Female
Fiber Connectors SC/APC
o
Operating Temperature C 0 to +40
Operating Humidity ≤ 85%
Ingress protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 50 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-3/ 1216
ComFlex-4100 40W
Specifications
Mechanical---HRU
40W
Dimensions, H x W x D mm 1350 x 315 x 225
Weight (approx.) kg 70
AC110/220V VAC 100-240/50-60Hz
Power Supply
DC-48 VDC -40 to -58
Power Consumption (approx.) W 1350
RF Connectors DIN-Female
Fiber Connectors SC/APC
o
Operating Temperature C -40 to +70
Operating Humidity ≤ 95%
Ingress protection IP65
Enclosure Cooling Fan
Installation Type Wall/Pole

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 51 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-3/ 1216
ComFlex-4100 40W
ComFlex Series Distributed Antenna System
ComFlex CM 20W
Features
 Modularized Master Unit and Remote Unit support field upgrade and independent gain control.
 RF module supports both simplex\ duplex optional and adjusts gain for each module.
 Full operation bandwidth system supports multi-operator application.
 Supports all major technologies GSM, CDMA, WCDMA, LTE
 Comply with 3GPP and supports LTE MIMO.
 Optical link auto gain control.
 Web based GUI for intelligent commissioning and configuration.
 Supports FOU extension in Master Unit.
 RU supports PSU\PA\optical backup (conditional) and white optional.

Product Description
The ComFlex series Distributed Antenna System is an RF over fiber solution that enhances a wireless network’s
coverage by extending cellular services from existing cell sites to an indoor environment. The system consists of the
Master Unit (MU) and high power Remote Unit (RU). The MU includes the Chassis, Power Supply Unit (PSU), Fibre
Optical Unit (FOU) and RF Unit (RFU). With a modular design, it can support up to 8 independent RF inputs and 8
Remote Units. The Remote Unit is designed with a compact form factor for easy installation, and its modular design
is easy for upgrading and maintenance, which supports up to 8 bands including MIMO frequency.

This solution is an effective point-to-multipoint distributed antenna system that provides effective coverage
enhancement. The Comba DAS offers service providers an optimal solution for multiple applications from a single
building to a campus, mega mall, or sports arena and beyond.

Functional Block Diagram

SISO System RU 1 RU 8


(optional)
BTS DAS Tray

RU 1 RU 4
MIMO System
BTS 1 (optional) …
DAS Tray

BTS 2

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 52 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-2 / 0316
ComFlex CM 20W Australia
Specifications
Optical
System 700MHz, 850MHz, 900MHz, 1800MHz, 2100MHz, 2300MHz, 2600MHz
Optical Fiber Single Mode
Optical Wavelength nm 1310, 1550 + WDM
Master Unit -4 to 2
Optical Output Power dBm
Remote Unit 3.0 to 5.0
Optical Return Loss dB > 50
Max. Optical Loss dB 6.5
Optical Automatic Gain Control dB 6.5
Fiber Connectors MU: SC/APC; RU: FC/APC
Maximum Remote Unit per Master Unit 8 (16 with FOU extension) in SISO; 4 (8 with FOU extension) in MIMO

Electrical
700 850 900 1800 2100 2300 2600
MHz MHz* MHz* MHz MHz MHz MHz
Uplink Frequency 1710-1785 1920-1980 2300-2400
703-748 824-849 880-915 2500-2570
Range
MHz
Downlink Frequency
758-803 869-894 925-960 1805-1880 2110-2170 2300-2400 2620-2690
Range
Operating Bandwidth MHz 45 25 35 75 60 100 70
Uplink Output Power dBm -30 -30 -30 -30 -30 -30 -30
Downlink Output Power dBm 43 43 43 43 43 43 43
Uplink Maximum gain dB 30
Downlink Maximum
dB 35
gain
ATT Adjustable Range
dB MU: 0-40, RU: 0-30
(1dB step)
Pass Band Ripple (p-p) dB ≤5 ≤5 ≤5 ≤6 ≤6 ≤6 ≤6
3GPP TS 3GPP TS
3GPP TS 3GPP TS 25.106 25.106 3GPP TS 3GPP TS 3GPP TS
Spurious emission
36.106 25.106 3GPP TS 3GPP TS 25.106 36.106 36.106
36.106 36.106
Uplink Noise Figure at
dB ≤5
Maximum Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max. Downlink Input
dBm 30
Power
* Note: 850MHz and 900MHz can’t be used together unless there is at least 5MHz frequency interval.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 53 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-2 / 0316
ComFlex CM 20W Australia
Specifications
Mechanical---MU
Chassis 178 x 482 x 360
Fiber Optical Unit 37 x 185 x 299
Dimensions, H x W x D mm
Per RF Unit 103 x 46 x 259
Power Supply Unit 140 x 63 x 400
Chassis 12
Fiber Optical Unit 2
Weight (approx.) kg
Per RF Unit 1
Power Supply Unit 2.5
Power Supply VAC 100-240/50-60Hz
Power Consumption (approx.) W 85
RF Connectors N-Female
Fiber Connectors SC/APC
o
Operating Temperature C 0 to +40
Operating Humidity ≤ 85%
Ingress protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

Mechanical---RU
CMU 528 x 298 x 251
Dimensions, H x W x D Per RF Unit mm 528 x 290 x 152
Mounting Rack 602 x 820 x 80
CMU 25
Weight (approx.) Per RF Unit kg 15
Mounting Rack 8
Power Supply AC110/220V VAC 100-240/50-60Hz
Power Consumption (approx.) W 1200 (8 bands)
RF Connectors N-Female
Fiber Connectors FC/APC
o
Operating Temperature C -40 to +55
Operating Humidity ≤ 95%
Ingress protection IP65
Enclosure Cooling Convection
Installation Type Wall

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 54 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-2 / 0316
ComFlex CM 20W Australia
ComFlex Series Distributed Antenna System
ComFlex CM 20W
Features
 Modularized Master Unit and Remote Unit support field upgrade and independent gain control.
 RF module supports both simplex\ duplex optional and adjusts gain for each module.
 Full operation bandwidth system supports multi-operator application.
 Supports all major technologies GSM, CDMA, WCDMA, LTE.
 Comply with 3GPP and supports LTE MIMO.
 Optical link auto gain control.
 Web based GUI for intelligent commissioning and configuration.
 Supports FOU extension in Master Unit.
 RU supports PSU\PA\optical backup (conditional) and balck optional.

Product Description
The ComFlex series Distributed Antenna System is an RF over fiber solution that enhances a wireless network’s
coverage by extending cellular services from existing cell sites to an indoor environment. The system consists of the
Master Unit (MU) and high power Remote Unit (RU). The MU includes the Chassis, Power Supply Unit (PSU), Fibre
Optical Unit (FOU) and RF Unit (RFU). With a modular design, it can support up to 8 independent RF inputs and 8
Remote Units. The Remote Unit is designed with a compact form factor for easy installation, and its modular design
is easy for upgrading and maintenance, which supports up to 8 bands including MIMO frequency.

This solution is an effective point-to-multipoint distributed antenna system that provides effective coverage
enhancement. The Comba DAS offers service providers an optimal solution for multiple applications from a single
building to a campus, mega mall, or sports arena and beyond.

Functional Block Diagram

SISO System RU 1 RU 8


(optional)
BTS DAS Tray

MIMO System RU 1 RU 4

BTS 1 (optional) …
DAS Tray

BTS 2

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 55 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-1 / 0416
ComFlex CM 20W CALA
Specifications
Optical
System 700MHz, 800MHz, 850MHz, 1800MHz, 1900MHz, 2100MHz, AWS, 2600MHz
Optical Fiber Single Mode
Optical Wavelength nm 1310, 1550 + WDM
Master Unit -4 to 2
Optical Output Power dBm
Remote Unit 3.0 to 5.0
Optical Return Loss dB > 50
Max. Optical Loss dB 6.5
Optical Automatic Gain Control dB 6.5
Fiber Connectors MU: SC/APC; RU: FC/APC
Maximum Remote Unit per Master Unit 8 (16 with FOU extension) in SISO; 4 (8 with FOU extension) in MIMO

Electrical
700 800 850 1800 1900 2100 2600
AWS**
MHz MHz* MHz* MHz** MHz** MHz** MHz
Uplink Frequency 1710-178 1850-191 1920-198
703-748 806-824 824-849 1710-1755 2500-2570
Range 5 0 0
MHz
Downlink Frequency 1805-188 1930-199 2110-217
758-803 851-869 869-894 2110-2155 2620-2690
Range 0 0 0
Operating Bandwidth MHz 45 18 25 75 60 60 45 70
Uplink Output Power dBm -30 -30 -30 -30 -30 -30 -30 -30
Downlink Output
dBm 43 43 43 43 43 43 43 43
Power
Uplink Maximum gain dB 30
Downlink Maximum
dB 35
gain
ATT Adjustable Range
dB MU: 0-40, RU: 0-30
(1dB step)
Pass Band Ripple
dB ≤6 ≤5 ≤5 ≤6 ≤6 ≤6 ≤6 ≤6
(p-p)
3GPP TS 3GPP TS
3GPP TS 3GPP TS 3GPP TS 25.106 3GPP TS 3GPP TS 25.106 3GPP TS
Spurious emission
36.106 25.106 25.106 3GPP TS 36.106 25.106 3GPP TS 36.106
36.106 36.106
Uplink Noise Figure at
dB ≤5
Maximum Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max. Downlink Input
dBm 30
Power
* Note: When 800MHz and 850MHz used together the gain will be 3dB decrease in 800MHz DL and 850MHz UL, and 800MHz output
power will be 40dBm and 850MHz NF will be 8dB.

** Note: 1800MHz, 1900MHz, 2100MHz and AWS band will not be used together due to frequency interference. Suggest 1800+2100 and
1900+AWS band.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 56 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-1 / 0416
ComFlex CM 20W CALA
Specifications
Mechanical---MU
Chassis 178 x 482 x 360
Fiber Optical Unit 37 x 185 x 299
Dimensions, H x W x D mm
Per RF Unit 103 x 46 x 259
Power Supply Unit 140 x 63 x 400
Chassis 12
Fiber Optical Unit 2
Weight (approx.) kg
Per RF Unit 1
Power Supply Unit 2.5
Power Supply VAC 100-240/50-60Hz
Power Consumption (approx.) W 85
RF Connectors N-Female
Fiber Connectors SC/APC
o
Operating Temperature C 0 to +40
Operating Humidity ≤ 85%
Ingress protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

Mechanical---RU
CMU 528 x 298 x 251
Dimensions, H x W x D Per RF Unit mm 528 x 290 x 152
Mounting Rack 602 x 820 x 80
CMU 25
Weight (approx.) Per RF Unit kg 15
Mounting Rack 8
Power Supply AC110/220V VAC 100-240/50-60Hz
Power Consumption (approx.) W 1200 (8 bands)
RF Connectors N-Female
Fiber Connectors FC/APC
o
Operating Temperature C -40 to +55
Operating Humidity ≤ 95%
Ingress protection IP65
Enclosure Cooling Convection
Installation Type Wall

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 57 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-1 / 0416
ComFlex CM 20W CALA
ComFlex Series Distributed Antenna System
ComFlex-8A00(CM) 20W
Features
 Modularized Master Unit and Remote Unit support field upgrade and independent gain control.
 RF module supports both simplex\ duplex optional and adjusts gain for each module.
 Full operation bandwidth system supports multi-operator application.
 Supports all major technologies GSM, CDMA, WCDMA, LTE.
 Comply with 3GPP and supports LTE MIMO.
 Optical link auto gain control.
 Web based GUI for intelligent commissioning and configuration.
 Supports FOU extension in Master Unit.
 RU supports PSU\PA\optical backup (conditional) and black optional.

Product Description
The ComFlex series Distributed Antenna System is an RF over fiber solution that enhances a wireless network’s
coverage by extending cellular services from existing cell sites to an indoor environment. The system consists of the
Master Unit (MU) and high power Remote Unit (RU). The MU includes the Chassis, Power Supply Unit (PSU), Fibre
Optical Unit (FOU) and RF Unit (RFU). With a modular design, it can support up to 8 independent RF inputs and 8
Remote Units. The Remote Unit is designed with a compact form factor for easy installation, and its modular design is
easy for upgrading and maintenance, which supports up to 8 bands including MIMO frequency.

This solution is an effective point-to-multipoint distributed antenna system that provides effective coverage
enhancement. The Comba DAS offers service providers an optimal solution for multiple applications from a single
building to a campus, mega mall, or sports arena and beyond.

Functional Block Diagram

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers’ requirements. Page 58 of 175
DS-Control: 0-0-3 / 0916
ComFlex-8A00(CM) 20W
Specifications
Optical
System 800MHz, 800MIMO, 900MHz, 1800MHz, 1800MIMO, 2100MHz, 2600MHz, 2600MIMO
Optical Fiber Single Mode
Optical Wavelength nm 1310, 1550 + WDM
Master Unit -4 to -2
Optical Output Power dBm
Remote Unit 3.0 to 5.0
Optical Return Loss dB > 50
Max. Optical Loss dB 6.5
Optical Automatic Gain Control dB 6.5
Fiber Connectors MU: SC/APC, RU: FC/APC
Maximum Remote Unit per Master Unit 8 (With FOU extension)

Electrical
800 800 900 1800 1800 2100 2600 2600
MHz MIMO MHz MHz MIMO MHz MHz MIMO
Uplink Frequency Range 832-862 832-862 880-915 1710-1785 1710-1785 1920-1980 2500-2570 2500-2570
Downlink Frequency MHz
791-821 791-821 925-960 1805-1880 1805-1880 2110-2170 2620-2690 2620-2690
Range
Operating Bandwidth MHz 30 30 35 75 75 60 70 70
Downlink Output Power dBm 43 43 43 43 43 43 43 43
Uplink Maximum gain dB 30
Downlink Maximum gain dB 35
ATT Adjustable Range
dB MU: 0-40, RU: 0-30
(1dB step)
Pass Band Ripple (p-p) dB ≤5 ≤5 ≤5 ≤6 ≤6 ≤6 ≤6 ≤6
3GPP TS 3GPP TS 25.106 3GPP TS
Spurious emission 3GPP TS 36.106 3GPP TS 36.106
25.106 3GPP TS 36.106 25.106
Uplink Noise Figure at
dB ≤5
Maximum Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max. Downlink Input
dBm 30
Power

Mechanical---MU
Chassis 178 x 482 x 360
Fiber Optical Unit 37 x 185 x 299
Dimensions, H x W x D mm
Per RF Unit 103 x 46 x 259
Power Supply Unit 140 x 63 x 400
Chassis 12
Fiber Optical Unit 2
Weight (approx.) kg
Per RF Unit 1
Power Supply Unit 2.5
Power Supply VAC 100-240/50-60Hz
Power Consumption (approx.) W 85
RF Connectors N-Female
Fiber Connectors SC/APC
o
Operating Temperature C 0 to +40
Operating Humidity ≤ 85%
Ingress protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers’ requirements. Page 59 of 175
DS-Control: 0-0-3 / 0916
ComFlex-8A00(CM) 20W
Specifications
Mechanical---RU
Total Dimension 602 x 300 x 873
CMU 528 x 298 x 251
Dimensions, H x W x D mm
RF Unit 528 x 290 x 152 *4
Mounting Rack 602 x 820 x 30
Total Weight 93
CMU 25
Weight (approx.) kg
RF Unit 15 *4
Mounting Rack 8
Power Supply AC110/220V VAC 100-240/50-60Hz
Power Consumption (approx.) W 1200
RF Connectors N-Female, duplex
Fiber Connectors FC/APC
o
Operating Temperature C -40 to +55
Operating Humidity ≤ 95%
Ingress protection IP65
Enclosure Cooling Convection
Installation Type Wall

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 60 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-3 / 0916
ComFlex-8A00(CM) 20W
ComFlex Series Distributed Antenna System
ComFlex-8C00(CM) 20W
Features
 Modularized Master Unit and Remote Unit support field upgrade and independent
gain control.
 RF module supports both simplex\duplex optional and adjusts gain for each module.
 Full operation bandwidth system supports multi-operator application.
 Supports all major technologies GSM, CDMA, WCDMA and LTE.
 Comply with 3GPP and supports LTE MIMO.
 Optical link auto gain control.
 Web based GUI for intelligent commissioning and configuration.
 Supports FOU extension in Master Unit.
 RU supports PSU\PA\optical backup (conditional) and grey optional.

Product Description
The ComFlex series Distributed Antenna System is an RF over fiber solution that enhances a wireless network’s
coverage by extending cellular services from existing cell sites to an indoor environment. The system consists of the
Master Unit (MU) and high power Remote Unit (RU). The MU includes the Chassis, Power Supply Unit (PSU), Fibre
Optical Unit (FOU) and RF Unit (RFU). With a modular design, it can support up to 8 independent RF inputs and 8
Remote Units. The Remote Unit is designed with a compact form factor for easy installation, and its modular design
is easy for upgrading and maintenance which supports 8 independent bands, 900MHz, 1800MHz, 2100MHz,
2600MHz, 900MIMO, 1800MIMO, 2100MIMO and 2600MIMO.

This solution is an effective point-to-multipoint distributed antenna system that provides effective coverage
enhancement. The Comba DAS offers service providers an optimal solution for multiple applications from a single
building to a campus, mega mall, or sports arena and beyond.

Functional Block Diagram

RU 1 RU 4

...

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers’ requirements. Page 61 of 175
DS-Control: 0-0-2 / 0217
ComFlex-8C00(CM) 20W
Specifications
Optical
900MHz, 900MIMO, 1800MHz, 1800MIMO, 2100MHz, 2100MIMO,2600MHz,
System
2600MIMO
Optical Fiber Single Mode
Optical Wavelength nm 1310, 1550 + WDM
Master Unit -4 to2
Optical Output Power dBm
Remote Unit 3.0 to 5.0
Optical Return Loss dB > 50
Max. Optical Loss dB 6.5
Optical Automatic Gain Control dB 6.5
Fiber Connectors MU: SC/APC; RU: FC/APC
Maximum Remote Unit per Master Unit 8 (With FOU extension)

Electrical
900 900 1800 1800 2100 2100 2600 2600
MHz MIMO MHz MIMO MHz MIMO MHz MIMO
Frequency Uplink 832-862 832-862 1710-1785 1710-1785 1920-1980 1920-1980 2500-2570 2500-2570
MHz
Range Downlink 791-821 791-821 1805-1880 1805-1880 2110-2170 2110-2170 2620-2690 2620-2690
Operating Bandwidth MHz 30 30 75 75 60 60 70 70
Uplink Output Power dBm -30 -30 -30 -30 -30 -30 -30 -30
Downlink Output Power dBm 43 43 43 43 43 43 43 43
Uplink Maximum gain dB 30
Downlink Maximum gain dB 35
ATT Adjustable Range
dB MU: 0-40, RU: 0-30
(1dB step)
Pass Band Ripple (p-p) dB ≤5 ≤5 ≤5 ≤5 ≤5 ≤5 ≤5 ≤5
3GPP TS 25.106
Spurious emission 3GPP TS 36.106 3GPP TS 25.106 3GPP TS 36.106
3GPP TS 36.106
Uplink Noise Figure at
dB ≤5
Maximum Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max. Downlink Input
dBm 30
Power

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers’ requirements. Page 62 of 175
DS-Control: 0-0-2 / 0217
ComFlex-8C00(CM) 20W
Specifications
Mechanical Specifications---MU
Total Dimension 178 x 482 x 480
Chassis 178 x 482 x 360
Dimensions, H x W x D Fiber Optical Unit mm 37 x 185 x 299
RF Unit 103 x 46 x 259
Power Supply Unit 140 x 63 x 400
Total Weight 29
Chassis 12
Weight (approx.) Fiber Optical Unit kg 2 *2
RF Unit 1 *8
Power Supply Unit 2.5 *2
Power Supply VAC 100-240/50-60Hz
Power Consumption (approx.) W 85
RF Connectors N-Female
Fiber Connectors SC/APC
o
Operating Temperature C 0 to +40
Operating Humidity ≤ 85%
Ingress protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

Mechanical Specifications---RU
Total Dimension 602 x 300 x 873
CMU 528 x 298 x 251
Dimensions, H x W x D mm
RF Unit 528 x 290 x 152 *4
Mounting Rack 602 x 30 x 873
Total Weight 95
CMU 27
Weight (approx.) kg
RF Unit 15 *4
Mounting Rack 8
Power Supply AC110/220V VAC 100-240/50-60Hz
Power Consumption (approx.) W 1200
RF Connectors N-Female
Fiber Connectors FC/APC
o
Operating Temperature C -40 to +55
Operating Humidity ≤ 95%
Ingress protection IP65
Enclosure Cooling Convection
Installation Type Wall

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers’ requirements. Page 63 of 175
DS-Control: 0-0-2 / 0217
ComFlex-8C00(CM) 20W
ComFlex Series Distributed Antenna System
ComFlex-5M00(AI) 10W20W
Features
 Low PIM to BTS (≤ -160dBc).
 ACU Cascade supported to share the monitoring.
 Max. DL input power of 100W per RFU of ACU.
 Modularized ACU and Remote Unit support field upgrade and
independent gain control.
 ACU supports 8 operators duplex input.
 Full operation bandwidth system supports multi-operator application.
 Supports all major technologies GSM, CDMA, WCDMA and LTE.
 Web based GUI for intelligent commissioning and configuration.
 Supports OCU extension.

Product Description
The ComFlex series Distributed Antenna System is an RF over fibre solution that enhances a wireless network’s
coverage by extending cellular services from existing cell sites to an indoor environment. The system consists of the
Active Conditioning Unit (ACU), Optical control Unit (OCU), Combiner and Remote Unit (RU). The ACU includes the
Chassis, Power Supply Unit (PSU) and RF Unit (RFU). With a modular design, it can support up to 8 independent
RF inputs and 8 Remote Units. The Remote Unit is designed with a compact and slim form factor for easy
installation; it is an integrated design which supports 3 independent bands.

This solution is an effective point-to-multipoint distributed antenna system that provides effective coverage
enhancement. The Comba DAS offers service providers an optimal solution for multiple applications from a single
building to a campus, mega mall, or sports arena and beyond.

Functional Block Diagram


RU 1 RU 8

ACU

BTS

Combiner

OCU

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 64 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-1 / 0416
ComFlex-5M00(AI) 10W20W
Specifications
Optical
System 1900MHz, AWS, 2600MHz
Optical Fiber Single Mode
Optical Wavelength nm 1310, 1550 + WDM
OCU -4 to -2
Optical Output Power dBm
Remote Unit 3.0 to 5.0
Optical Return Loss dB > 50
Max. Optical Loss dB 6.5
Optical Automatic Gain Control dB 6.5
Fiber Connectors OCU: SC/APC, RU: FC/APC
Maximum Remote Unit connected to OCUs 8

Electrical
1900MHz AWS 2600
Uplink 1850-1910 1710-1755 2500-2570
Frequency Range MHz
Downlink 1930-1990 2110-2155 2620-2690
Operating Bandwidth MHz 65 45 70
Downlink Output Power dBm 43 43 43
Uplink Maximum gain dB -3
Downlink Maximum gain dB -3 @ 46dBm input
ATT Adjustable Range (1dB step) dB ACU: 0-70, RU: 0-30
Pass Band Ripple (p-p) dB ≤6 ≤5 ≤6
3GPP TS 25.106 3GPP TS 25.106
Spurious emission 3GPP TS 36.106
3GPP TS 36.106 3GPP TS 36.106
Uplink Noise Figure at Maximum
dB ≤5
Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max. Downlink Input Power per
dBm 50
RFU of ACU

Mechanical---ACU
Dimensions, H x W x D mm 220 x 482.5 x 450
Weight (approx.) kg 50 (with 8 RFUs)
VAC 100-240
Power Supply
VDC -48
Power Consumption (approx.) W 180 (with 8 RFUs)
RF Connectors Input: Din, duplex; Output: QMA, simplex
o
Operating Temperature C 0 to +45
Operating Humidity ≤ 85%
Ingress Protection IP30
Enclosure Cooling Fan
Installation Type 19” Rack

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 65 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-1 / 0416
ComFlex-5M00(AI) 10W20W
Specifications
Mechanical---Combiner
Dimensions, H x W x D mm 44 x 485 x 450
Weight (approx.) kg 8
RF Connectors QMA-Female, simplex
o
Operating Temperature C 0 to +45
Operating Humidity ≤ 85%
Ingress Protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

Mechanical---OCU
Dimensions, H x W x D mm 44 x 485 x 450
Weight (approx.) kg 8 (with 2 FOUs)
Power Supply DC +28V (from ACU) @ 0.7A
Power Consumption (approx.) W 30
RF Connectors QMA-Female, simplex
Fiber Connectors SC/APC
o
Operating Temperature C 0 to +45
Operating Humidity ≤ 85%
Ingress Protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

Mechanical Specifications---RU
10W 20W
Dimensions, H x W x D mm 1270 x 236 x 200
Weight (approx.) kg 49
Power Supply VAC 100-240/47-36Hz
Power Consumption (approx.) W 850 1100
RF Connectors 3 x 7/16 DIN-F
Fiber Connectors SC/APC
o
Operating Temperature C -40 to +55
Operating Humidity ≤ 95%
Ingress protection IP65
Enclosure Cooling Fan
Installation Type Wall/Pole

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 66 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-1 / 0416
ComFlex-5M00(AI) 10W20W
ComFlex Series Distributed Antenna System
ComFlex-5900(AM) 20W
Features
 Low PIM to BTS (≤ -160dBc).
 ACU Cascade supported to share the monitoring.
 Max. DL input power of 100W per RFU of ACU.
 Modularized ACU and Remote Unit support field upgrade and
independent gain control.
 ACU supports 8 operators duplex input.
 Full operation bandwidth system supports multi-operator application.
 Supports all major technologies GSM, CDMA, WCDMA and LTE.
 Web based GUI for intelligent commissioning and configuration.
 Supports OCU extension.
 RU supports PSU\PA\optical backup (conditional) and black optional.

Product Description
The ComFlex series Distributed Antenna System is an RF over fibre solution that enhances a wireless network’s
coverage by extending cellular services from existing cell sites to an indoor environment. The system consists of the
Active Conditioning Unit (ACU), Optical control Unit (OCU), Combiner and Remote Unit (RU). The ACU includes the
Chassis, Power Supply Unit (PSU) and RF Unit (RFU). With a modular design, it can support up to 8 independent
RF inputs and 8 Remote Units. The Remote Unit is designed with a compact form factor for easy installation, and its
modular design is easy for upgrading and maintenance which supports 3 independent bands, 850MIHz, 1900MHz
and AWS.

This solution is an effective point-to-multipoint distributed antenna system that provides effective coverage
enhancement. The Comba DAS offers service providers an optimal solution for multiple applications from a single
building to a campus, mega mall, or sports arena and beyond.

Functional Block Diagram

ACU

BTS RU 1 RU 8

Combiner

OCU

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 67 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-1 / 0316
ComFlex-5900(AM) 20W
Specifications
Optical
System 850MHz, 1900MHz, AWS
Optical Fiber Single Mode
Optical Wavelength nm 1310, 1550 + WDM
OCU -4 to -2
Optical Output Power dBm
Remote Unit 3.0 to 5.0
Optical Return Loss dB > 50
Max. Optical Loss dB 6.5
Optical Automatic Gain Control dB 6.5
Fiber Connectors OCU: SC/APC, RU: FC/APC
Maximum Remote Unit connected to OCUs 8 (With FOU extension)

Electrical
850MHz 1900MHz AWS
Uplink 824-849 1850-1910 1710-1755
Frequency Range MHz
Downlink 869-894 1930-1990 2110-2155
Operating Bandwidth MHz 25 60 45
Downlink Output Power dBm 43 43 43
Uplink Maximum gain dB -3 @ 46dBm input
Downlink Maximum gain dB -3 @ 46dBm input
ATT Adjustable Range(1dB step) dB ACU: 0-70, RU: 0-30
Pass Band Ripple (p-p) dB ≤5 ≤6 ≤6
3GPP TS 25.106 3GPP TS 25.106 3GPP TS 25.106
Spurious emission
3GPP TS 36.106 3GPP TS 36.106 3GPP TS 36.106
Uplink Noise Figure at Maximum
dB ≤5
Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max. Downlink Input Power per
dBm 50
RFU of ACU

Mechanical---ACU
Dimensions, H x W x D mm 220 x 482.5 x 450
Weight (approx.) kg 50 (with 8 RFUs)
VAC 100-240
Power Supply
VDC -48
Power Consumption (approx.) W 180 (with 8 RFUs)
RF Connectors Input: Din, duplex; Output: QMA, simplex
o
Operating Temperature C 0 to +45
Operating Humidity ≤ 85%
Ingress Protection IP30
Enclosure Cooling Fan
Installation Type 19” Rack

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 68 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-1 / 0316
ComFlex-5900(AM) 20W
Specifications
Mechanical---Combiner
Dimensions, H x W x D mm 44 x 485 x 450
Weight (approx.) kg 8
RF Connectors QMA-Female, simplex
o
Operating Temperature C 0 to +45
Operating Humidity ≤ 85%
Ingress Protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

Mechanical---OCU
Dimensions, H x W x D mm 44 x 485 x 450
Weight (approx.) kg 8 (with 2 FOUs)
Power Supply DC +28V (from ACU) @ 0.7A
Power Consumption (approx.) W 30
RF Connectors QMA-Female, simplex
Fiber Connectors SC/APC
o
Operating Temperature C 0 to +45
Operating Humidity ≤ 85%
Ingress Protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

Mechanical---RU
CMU 528 x 251 x 298
Dimensions, H x W x D RF Unit mm 528 x 152 x 290*2
Mounting Rack 602 x 820 x 30
CMU 30
Weight (approx.) RF Unit kg 20*2
Mounting Rack 8
Power Supply AC110/220V VAC 100-240/50-60Hz
Power Consumption (approx.) W 500
RF Connectors N-Female, duplex
Fiber Connectors FC/APC
o
Operating Temperature C -40 to +55
Operating Humidity ≤ 95%
Ingress protection IP65
Enclosure Cooling Convection
Installation Type Wall

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 69 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-1 / 0316
ComFlex-5900(AM) 20W
ComFlex Series Distributed Antenna System
ComFlex-4100(AM) 20W
Features
 Low PIM to BTS (≤ -160dBc).
 ACU Cascade supported to share the monitoring.
 Max. DL input power of 100W per RFU of ACU.
 Modularized ACU and Remote Unit support field upgrade and
independent gain control.
 ACU supports 8 operators duplex input.
 Full operation bandwidth system supports multi-operator application.
 Supports all major technologies GSM, CDMA, WCDMA and LTE.
 Web based GUI for intelligent commissioning and configuration.
 Supports OCU extension.
 Remote Unit supports PSU/PA/optical backup (conditional) and grey optional.

Product Description
The ComFlex series Distributed Antenna System is an RF over fibre solution that enhances a wireless network’s
coverage by extending cellular services from existing cell sites to an indoor environment. The system consists of the
Active Conditioning Unit (ACU), Optical control Unit (OCU), Combiner and Remote Unit (RU). The ACU includes the
Chassis, Power Supply Unit (PSU) and RF Unit (RFU). With a modular design, it can support up to 8 independent
RF inputs and 8 Remote Units. The Remote Unit is designed with a compact form factor for easy installation, and its
modular design is easy for upgrading and maintenance.

This solution is an effective point-to-multipoint distributed antenna system that provides effective coverage
enhancement. The Comba DAS offers service providers an optimal solution for multiple applications from a single
building to a campus, mega mall, or sports arena and beyond.

Functional Block Diagram

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 70 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-1 / 0117
ComFlex-4100(AM) 20W
Specifications
Optical
System 900MHz, 1800MHz, 2100MHz, 2600MHz
Optical Fiber Single Mode
Optical Wavelength nm 1310, 1550 + WDM
Optical Control Unit -4 to -2
Optical Output Power dBm
Remote Unit 3.0 to 5.0
Optical Return Loss dB > 50
Max. Optical Loss dB 6.5
Optical Automatic Gain Control dB 6.5
Fiber Connectors OCU: SC/APC, RU: FC/APC
Maximum Remote Unit per Master Unit 8 (SISO) / 4 (MIMO)

Electrical
900MHz 1800MHz 2100MHz 2600MHz
Uplink Frequency Range 880-915 1710-1785 1920-1980 2500-2570
MHz
Downlink Frequency Range 925-960 1805-1880 2110-2170 2620-2690
Operating Bandwidth MHz 35 75 60 70
Downlink Output Power dBm 43 43 43 43
Uplink Maximum gain dB -3
Downlink Maximum gain
dB -3
(@46dBm input)
ATT Adjustable Range (1dB
dB ACU: 0-70, RU: 0-30
step)
Pass Band Ripple (p-p) dB ≤5 ≤6 ≤6 ≤6
3GPP TS 25.106
Spurious emission 3GPP TS 25.106 3GPP TS 25.106 3GPP TS 36.106
3GPP TS 36.106
Uplink Noise Figure at
dB ≤5
Maximum Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max. Downlink Input Power dBm 50

Mechanical---ACU
Dimensions, H x W x D mm 220 x 482.5 x 450
Weight (approx.) kg 50 (with 8 RFUs)
VAC 100-240
Power Supply
VDC -48
Power Consumption (approx.) W 180 (with 8 RFUs)
RF Connectors Input: Din, duplex; Output: QMA, simplex
o
Operating Temperature C 0 to +45
Operating Humidity ≤ 85%
Ingress Protection IP30
Enclosure Cooling Fan
Installation Type 19” Rack

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 71 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-1 / 0117
ComFlex-4100(AM) 20W
Specifications
Mechanical---Combiner
Dimensions, H x W x D mm 44 x 485 x 450
Weight (approx.) kg 8
RF Connectors QMA-Female, simplex
o
Operating Temperature C 0 to +45
Operating Humidity ≤ 85%
Ingress Protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

Mechanical---OCU
Dimensions, H x W x D mm 44 x 485 x 450
Weight (approx.) kg 8 (with 2 FOUs)
Power Supply DC +28V (from ACU) @ 0.7A
Power Consumption (approx.) W 20
RF Connectors QMA-Female, simplex
Fiber Connectors SC/APC
o
Operating Temperature C 0 to +45
Operating Humidity ≤ 85%
Ingress Protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

Mechanical---RU
Total Dimension 602 x 555 x 300
CMU 528 x 298 x 251
Dimensions, H x W x D mm
RF Unit 528 x 290 x 152 *2
Mounting Rack 602 x 555 x 30
Total Weight 63
CMU 25
Weight (approx.) kg
RF Unit 15 *2
Mounting Rack 8
Power Supply AC110/220V VAC 100-240/50-60Hz
Power Consumption (approx.) W 650
RF Connectors N-Female, duplex
Fiber Connectors FC/APC
o
Operating Temperature C -40 to +55
Operating Humidity ≤ 95%
Ingress protection IP65
Enclosure Cooling Convection
Installation Type Wall

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 72 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-1 / 0117
ComFlex-4100(AM) 20W
ComFlex Series Distributed Antenna System
ComFlex-8A00(AM) 20W
Features
 Low PIM to BTS (≤ -160dBc).
 ACU Cascade supported to share the monitoring.
 Max. DL input power of 100W per RFU of ACU.
 Modularized ACU and Remote Unit support field upgrade and
independent gain control.
 ACU supports 8 operators duplex input.
 Full operation bandwidth system supports multi-operator application.
 Supports all major technologies GSM, CDMA, WCDMA and LTE.
 Web based GUI for intelligent commissioning and configuration.
 Supports OCU extension.
 Remote Unit supports PSU/PA/optical backup (conditional) and gray optional.

Product Description
The ComFlex series Distributed Antenna System is an RF over fibre solution that enhances a wireless network’s
coverage by extending cellular services from existing cell sites to an indoor environment. The system consists of the
Active Conditioning Unit (ACU), Optical control Unit (OCU), Combiner and Remote Unit (RU). The ACU includes the
Chassis, Power Supply Unit (PSU) and RF Unit (RFU). With a modular design, it can support up to 8 independent RF
inputs and 8 Remote Units. The Remote Unit is designed with a compact form factor for easy installation, and its
modular design is easy for upgrading and maintenance.

This solution is an effective point-to-multipoint distributed antenna system that provides effective coverage
enhancement. The Comba DAS offers service providers an optimal solution for multiple applications from a single
building to a campus, mega mall, or sports arena and beyond.

Functional Block Diagram

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers’ requirements. Page 73 of 175
DS-Control: 0-0-3 / 1016
ComFlex-8A00(AM) EU 20W
Specifications
Optical
System 800MHz, 800MIMO, 900MHz, 1800MHz, 1800MIMO, 2100MHz, 2600MHz, 2600MIMO
Optical Fiber Single Mode
Optical Wavelength nm 1310, 1550 + WDM
OCU -4 to -2
Optical Output Power dBm
Remote Unit 3.0 to 5.0
Optical Return Loss dB > 50
Max. Optical Loss dB 6.5
Optical Automatic Gain Control dB 6.5
Fiber Connectors OCU: SC/APC, RU: FC/APC
Maximum Remote Unit connected to OCUs 8 (with FOU extension)

Electrical
800 800 900 1800 1800 2100 2600 2600
MHz MIMO MHz MHz MIMO MHz MHz MIMO
Uplink Frequency 1710-178 1710-178 1920-198 2500-257
832-862 832-862 880-915 2500-2570
Range 5 5 0 0
MHz
Downlink Frequency 1805-188 1805-188 2110-217 2620-269
791-821 791-821 925-960 2620-2690
Range 0 0 0 0
Operating Bandwidth MHz 30 30 35 75 75 60 70 70
Downlink Output Power dBm 43 43 43 43 43 43 43 43
Uplink Maximum gain dB -3
Downlink Maximum gain
dB -3
(@46dBm input)
ATT Adjustable Range
dB ACU: 0-70, RU: 0-30
(1dB step)
Pass Band Ripple (p-p) dB ≤5 ≤5 ≤5 ≤6 ≤6 ≤6 ≤6 ≤6
3GPP TS 3GPP TS 25.106 3GPP TS
Spurious emission 3GPP TS 36.106 3GPP TS 36.106
25.106 3GPP TS 36.106 25.106
Uplink Noise Figure at
dB ≤5
Maximum Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max. Downlink Input
dBm 50
Power per RFU of ACU

Mechanical---ACU
Dimensions, H x W x D mm 220 x 482.5 x 450
Weight (approx.) kg 50 (with 8 RFUs)
VAC 100-240
Power Supply
VDC -48
Power Consumption (approx.) W 180 (with 8 RFUs)
RF Connectors Input: Din, duplex; Output: QMA, simplex
o
Operating Temperature C 0 to +45
Operating Humidity ≤ 85%
Ingress Protection IP30
Enclosure Cooling Fan
Installation Type 19” Rack

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers’ requirements. Page 74 of 175
DS-Control: 0-0-3 / 1016
ComFlex-8A00(AM) EU 20W
Specifications
Mechanical---Combiner
Dimensions, H x W x D mm 44 x 485 x 450
Weight (approx.) kg 8
RF Connectors QMA-Female, simplex
o
Operating Temperature C 0 to +45
Operating Humidity ≤ 85%
Ingress Protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

Mechanical---OCU
Dimensions, H x W x D mm 44 x 485 x 450
Weight (approx.) kg 8 (with 2 FOUs)
Power Supply DC +28V (from ACU) @ 0.7A
Power Consumption (approx.) W 20
RF Connectors QMA-Female, simplex
Fiber Connectors SC/APC
o
Operating Temperature C 0 to +45
Operating Humidity ≤ 85%
Ingress Protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack

Mechanical---RU
Total Dimension 602 x 300 x 873
CMU 528 x 298 x 251
Dimensions, H x W x D mm
RF Unit 528 x 290 x 152 *4
Mounting Rack 602 x 820 x 30
Total Weight 93
CMU 25
Weight (approx.) kg
RF Unit 15 *4
Mounting Rack 8
Power Supply AC110/220V VAC 100-240/50-60Hz
Power Consumption (approx.) W 1200
RF Connectors N-Female, duplex
Fiber Connectors FC/APC
o
Operating Temperature C -40 to +55
Operating Humidity ≤ 95%
Ingress protection IP65
Enclosure Cooling Convection
Installation Type Wall

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Specifications may differ depending on region and customers’ requirements. Page 75 of 175
DS-Control: 0-0-3 / 1016
ComFlex-8A00(AM) EU 20W
RX Series Digital Band Selective Repeater
Features
 Up to 4 pass band segments with independent ON/OFF for maximum flexibility.
 5W/10W total output power.
 Integrated wireless modem for remote configuration, monitoring and control.
 Offline isolation detection for easy commissioning.
 Internal backup battery keeps the alarm unit running for up to two hours after power failure.
 Compatible to Comba generic OMT and CMS platform.
 Designed for all weather outdoor installation – waterproof, damp-proof and omni-sealed (IP65).
 Can be configured as Master Unit (MU) or Slave Unit (SU) in a centralized monitoring system.

Functional Block Diagram

LNA1 PA1

Mobile
Donor Ant
Ant Integrated Frequency
DT selective module MT

Mobile

BTS PA2 LNA2

OMT
Computer with
Data card

Alarm Power Li-ion


Indicator Main Control Unit Supply BATT
Wireless Modem
Modem

OMC
External
OMT Power

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 76 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-1 / 0116
Operation and Maintenance
 Using a direct connection to a PC by RJ45, installation and commissioning of the system is accomplished by the
OMT. Using the integrated wireless modem, the equipment parameters can be monitored and controlled
remotely.
 Controlled equipment parameters include: RF Switch, Carrier Switch, Isolation Detection Switch, Channel No.
Range, ATT, Over-Temp Threshold, DL Input Power Threshold, DL Output Power Threshold and Alarm Report
Enable.
 Monitored equipment parameters include: Alarms (LNA, PA, PLL unlock, Power Down, PSU Fault, Door Open,
DL Input power Overload, DL Output Power Low, Over Temp, VSWR), DL Output Power and DL Input Power.
 The system has been developed to take advantage of advanced network operation, where the CMS (optional)
provides an effective solution for central monitoring of a group of Comba products.

Outline Drawing

300 164

RUN

ALM

MODEM
430

AC 100V-240V
50/60Hz AC OUT
RS-485 EXT_ALM MODEM ANT

DT MT

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 77 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-1 / 0116
U30M
LTE700 Digital Band Selective Repeater
RX-0739
Specifications
Electrical 5W 10W
Frequency Range, Uplink MHz 718-748
Frequency Range, Downlink MHz 773-803
Operating Bandwidth Per Sub-band MHz 3-20
Number of Sub-bands 4
Total Output Power, Uplink dBm 23
Total Output Power, Downlink dBm 37 40
Maximum System Gain dB 90
Gain Adjustment Range (1dB step) dB 0-30
Pass Band Ripple, p-p dB 5
Uplink Noise Figure dB 5
System Group Delay sec  6.5
Out of Band Gain
ACRR
EVM
Compliance with 3GPP 36.106
Out of Band Spectrum Emissions
Input Intermodulation
Output Intermodulation
Absolute Maximum RF Input Power dBm -10
Input VSWR  1.5
Impedance  50
Mechanical
Dimensions, H x W x D mm 430 x 300 x 164
Weight (approx.) kg 18
Power Supply VAC 100-240/47-63Hz
Power Consumption (approx.) W 160 170
Power Up Waiting Time (approx.) sec 180
MCU Battery Backup Time (approx.) hr 2
Enclosure Cooling Convection
RF Connectors N-Female
Operating Temperature C -33 to +55
Operating Humidity  95%
Environmental Class IP65
MTBF hrs ≥ 50,000
Note: Typical specifications at room temperature

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 78 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-1 / 0116
U30M
850MHz Digital Band Selective Repeater
RX-8132
Specifications
Electrical 5W 10W
Operating Frequency, Uplink MHz 824-849
Operation Frequency, Downlink MHz 869-894
Operating Bandwidth Per Sub-band MHz 0.2-24.8
Number of Sub-bands 2
Total Output Power, Uplink dBm 33
Total Output Power, Downlink dBm 37 40
Maximum System Gain dB 90
Attenuation Adjustment Range (1dB step) dB 0-30
Pass Band Ripple, p-p dB ≤5
Uplink Noise Figure dB 5
System Group Delay sec ≤ 6.5
Offset ≥ 600KHz ≥ 45
Out-of-Band Rejection dBc
Offset ≥ 1MHz ≥ 60
Intermodulation @ GSM dBc ≥ 40
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 1.5
Impedance  50
Mechanical
Dimensions, H x W x D mm/in 430x300x164/16.9x11.8x6.5
Weight (approx.) kg/lb 18/39.7
Power Supply VAC 100-240/47-63Hz
Power Consume W 140 160
Power Up Waiting Time (approx.) sec 180
MCU Battery Backup Time (approx.) hr 2
Enclosure Cooling Convection
RF Connectors N-Female
Operating Temperature C -33 to +50
Operating Humidity  95%
Environmental Class IP65
MTBF hrs > 50,000
Note: Typical specification at room temperature;
.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 79 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 2-0-1 / 0314
900MHz Digital Band Selective Repeater
RX-9139
Specifications
Electrical 5W 10W
Operating Frequency, Uplink MHz 885-915
Operation Frequency, Downlink MHz 930-960
Operating Bandwidth Per Sub-band MHz 0.2-25
Number of Sub-bands 4
Total Output Power, Uplink dBm 27
Total Output Power, Downlink dBm 37 40
Maximum System Gain dB 90
Attenuation Adjustment Range (1dB step) dB 0-30
Pass Band Ripple, p-p dB ≤5
Uplink Noise Figure dB 5
Out-of-Band Gain
Intermodulation
Spurious Emission
EVM Compliance with 3GPP TS 25.106
ACRR
PCDE
Spurious Emission Mask
System Group Delay sec ≤ 6.5
Offset ≥ 600KHz ≥ 45
Out-of-Band Rejection dBc
Offset ≥ 1MHz ≥ 60
Intermodulation @ GSM dBc ≥ 40
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 1.5
Impedance  50
Mechanical
Dimensions, H x W x D mm 430 x 300 x 164
Weight (approx.) kg 18
Power Supply VAC 100-240/47-63Hz
Power Consume W 140 160
Power Up Waiting Time (approx.) sec 180
MCU Battery Backup Time (approx.) hr 2
Enclosure Cooling Convection
RF Connectors N-Female
Operating Temperature C -33 to +50
Operating Humidity  95%
Environmental Class IP65
MTBF hrs > 50,000
Note: Typical specification at room temperature;
.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 80 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-6 / 1115
U30M
1800MHz Digital Band Selective Repeater
RX-1839
Specifications
Electrical 5W 10W
Frequency Range, Uplink MHz 1710-1785
Frequency Range, Downlink MHz 1805-1880
Operating Bandwidth Per Sub-band MHz 0.2-25
Number of Sub-bands 4
Instantaneous Bandwidth MHz 60
Total Output Power, Uplink dBm 30
Total Output Power, Downlink dBm 37 40
Maximum System Gain dB 90
Gain Adjustment Range (1dB step) dB 0-30
Pass Band Ripple, p-p dB 5
Uplink Noise Figure dB 5
System Group Delay sec  6.5
Out of Band Gain
ACRR
EVM
Compliance with ETSI EN 301 908-15*
Out of Band Spectrum Emissions
Input Intermodulation
Output Intermodulation
±600kHz ≥ 45
Out-of-Band Rejection@ GSM dBc
±1MHz ≥ 60
Intermodulation @ GSM dBc ≥ 40
Absolute Maximum RF Input Power dBm -10
Input VSWR  1.5
Impedance  50
Mechanical
Dimensions, H x W x D mm 430 x 300 x 164
Weight (approx.) kg 18
Power Supply VAC 100-240/47-63Hz
Power Consumption (approx.) W 160 170
Power Up Waiting Time (approx.) sec 180
MCU Battery Backup Time (approx.) hr 2
Enclosure Cooling Convection
RF Connectors N-Female
Operating Temperature C -33 to +55
Operating Humidity  95%
Environmental Class IP65
MTBF hrs ≥ 50,000
Note: Typical specifications at room temperature
*: Compliant to LTE standard @ UL 23dBm.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 81 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-3 / 0214
1900MHz Digital Band Selective Repeater
RX-1939
Specifications
Electrical 5W 10W
Frequency Range, Uplink MHz 1850-1910
Frequency Range, Downlink MHz 1930-1990
Operating Bandwidth Per Sub-band MHz 0.2-25
Number of Sub-bands 4
Total Output Power, Uplink dBm 30
Total Output Power, Downlink dBm 37 40
Maximum System Gain dB 90
Gain Adjustment Range (1dB step) dB 0-30
Pass Band Ripple, p-p dB 6
Uplink Noise Figure dB 5
System Group Delay sec  6.5
±600kHz dBc ≥ 45
Out-of-Band Rejection
±1MHz dBc ≥ 60
9kHz-1GHz dBm -36
Spurious
1GHz-12.75GHz dBm -30
Absolute Maximum RF Input Power dBm -10
Input VSWR  1.5
Impedance  50
Mechanical
Dimensions, H x W x D mm/in 430 x 300 x 164/16.9 x 11.8 x 6.5
Weight (approx.) kg/lb 18/39.7
Power Supply VAC 100-240/47-63Hz
Power Consumption (approx.) W 150 160
Power Up Waiting Time (approx.) sec 180
MCU Battery Backup Time (approx.) hrs 2
Enclosure Cooling Convection
RF Connectors N-Female
Operating Temperature C -33 to +55
Operating Humidity  95%
Environmental Class IP65
MTBF hrs ≥ 50,000
Note: Typical specifications at room temperature

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 82 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 2-0-0 / 0314
2100MHz Digital Band Selective Repeater
RX-2139
Specifications
Electrical 5W 10W 20W
Frequency Range, Uplink MHz 1920-1980
Frequency Range, Downlink MHz 2110-2170
Operating Bandwidth Per Sub-band MHz 3-20
Number of Sub-bands 4
Instantaneous Bandwidth MHz 30
Total Output Power, Uplink dBm 23
Total Output Power, Downlink dBm 37 40 43
Maximum System Gain 90
Gain Adjustment Range (1dB step) dB 0-30
Pass Band Ripple at 3.84MHz dB ≤2
Uplink Noise Figure dB 5
System Group Delay sec  6.5
Out-of-Band Gain
Intermodulation
Spurious Emission
Compliance with 3GPP TS 25 106
EVM
Compliance with 3GPP TS 36 106
ACRR
PCDE
Spurious Emission Mask
Absolute Maximum RF Input Power dBm -10
Input VSWR  1.5
Impedance  50
Mechanical
Dimensions, H x W x D mm 430 x 300 x 164
Weight (approx.) kg 18
Power Supply 100-240/47-63Hz
Power Consumption (approx.) W 150 160 180
Power Up Waiting Time (approx.) sec 180
MCU Battery Backup Time (approx.) hr 2
Enclosure Cooling Convection
RF Connectors N-Female
Operating Temperature C -33 to +55
Operating Humidity  95%
Environmental Class IP65
MTBF hr ≥ 50,000
Note: Typical specifications at room temperature

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 83 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-1-0 / 0316
2600MHz Digital Band Selective Repeater
RX-2620
Specifications
Electrical 5W 10W
Frequency Range, Uplink MHz 2500-2570
Frequency Range, Downlink MHz 2620-2690
Operating Bandwidth MHz 10/15/20
Total Output Power, Uplink dBm 23
Total Output Power, Downlink dBm 37 40
Maximum System Gain dB 85
Gain Adjustment Range (1dB Step) dB 0-30
Pass Band Ripple dB 4
Uplink Noise Figure dB 5
System Group Delay sec 7
Out of Band Gain
ACRR
EVM
Compliance with 3GPP TS 36.106
Out of Band Spectrum Emissions
Input Intermodulation
Output Intermodulation
Absolute Maximum RF Input Power dBm -10
Input VSWR  1.5
Impedance  50
Mechanical
Dimensions, H x W x D mm 330 x 420 x 182
Weight (approx.) kg 25
Power Supply VAC 100-240/47-63Hz
Power Consumption W 150 170
Power Up Waiting Time (approx.) sec 180
MCU Battery Backup Time (approx.) hr 2
Enclosure Cooling Convection
RF Connectors N-Female
Operating Temperature °C -33 to +55
Operating Humidity 95%
Environmental Class IP65
MTBF hr ≥ 50,000
Note: Typical specifications at room temperature

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 84 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-2 / 0314
Multi-band Digital Band Selective Repeater
Features
 2 or 3 bands configuration in one system.
 Each band has up to 4 pass band segments with independent ON/OFF
for maximum flexibility.
 5W/10W total output power for each band.
 Integrated wireless modem for remote configuration, monitoring and control.
 Offline isolation detection for easy commissioning.
 Internal backup battery keeps the alarm unit running for up to two hours after power failure.
 Compatible to Comba generic OMT and CMS platform.
 Designed for all weather outdoor installation – waterproof, damp-proof and omni-sealed (IP65).

Functional Block Diagram

DL LNA DL PA

Digital Frequency
Selective Module

UL PA UL LNA

BTS

Donor Ant Alarm Power Li-ion


Indicator Main Control Unit Supply BATT Mobile
Modem
Ant

Mobile
RS485
DT MT

OMT

OMT Computer with Data card

Alarm Power Li-ion


Indicator Main Control Unit Supply BATT

Wireless
Modem

OMC
DL LNA DL PA

Digital Frequency
Selective Module

UL PA UL LNA

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 85 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-2 / 0314
Operation and Maintenance
 Using a direct connection to a PC by RJ45, installation and commissioning of the system is accomplished by the
OMT. Using the integrated wireless modem, the equipment parameters can be monitored and controlled
remotely.
 Controlled equipment parameters include: RF Switch, Carrier Switch, Isolation Detection Switch, Channel No.
Range, ATT, Over-Temp Threshold, DL Input Power Threshold, DL Output Power Threshold and Alarm Report
Enable.
 Monitored equipment parameters include: Alarms (LNA, PA, PLL unlock, Power Down, PSU Fault, Door Open,
DL Input power Overload, DL Output Power Low, Over Temp, VSWR), DL Output Power and DL Input Power.
 The RX-system has been developed to take advantage of advanced network operation, where the CMS
(optional) provides an effective solution for central monitoring of a group of Comba products.

Outline Drawing

440 355
408

Dual band

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 86 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-2 / 0314
645

433

Tri-band

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 87 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-2 / 0314
850MHz + 1900MHz Digital Band Selective Repeater
RX-7137
Specifications-850MHz
Electrical 5W 10W
Frequency Range, Uplink MHz 824-849
Frequency Range, Downlink MHz 869-894
Operating Bandwidth Per Sub-band MHz 0.2-24.8
Number of Sub-bands 2
Total Output Power, Uplink dBm 33
Total Output Power, Downlink dBm 37 40
Maximum System Gain 90
Gain Adjustment Range (1dB step) dB 0-30
Pass Band Ripple at FBW, p-p dB 5
Uplink Noise Figure dB 5
System Group Delay sec  6.5
±600kHz dB ≥ 45
Out-of-Band Rejection@ GSM
±1MHz dB ≥ 60
Intermodulation@ GSM dBc ≥ 40
Absolute Maximum RF Input Power dBm -10
Input VSWR  1.5
Impedance  50
Note: Typical specifications at room temperature

Specifications-1900MHz
Electrical 5W 10W
Frequency Range, Uplink MHz 1850-1910
Frequency Range, Downlink MHz 1930-1990
Operating Bandwidth Per Sub-band 0.2-25
Number of Sub-bands 4
Total Output Power, Uplink dBm 30
Total Output Power, Downlink dBm 37 40
Maximum System Gain 90
Gain Adjustment Range (1dB step) dB 0-30
Pass Band Ripple, p-p dB 6
Uplink Noise Figure dB 5
System Group Delay sec  6.5
±600kHz dB ≥ 45
Out-of-Band Rejection@ GSM
±1MHz dB ≥ 60
Intermodulation@ GSM dBc ≥ 40
Absolute Maximum RF Input Power dBm -10
Input VSWR  1.5
Impedance  50
Note: Typical specifications at room temperature

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 88 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-2 / 0314
Specifications
Mechanical 5W 10W
Dimensions, H x W x D mm/In 440 x 408 x 355/17.3 x 16 x 14
Weight (approx.) kg/lb 45/99.2
Power Supply 100-240/47-63Hz
Power Consumption (approx.) W 290 320
Power Up Waiting Time (approx.) sec 180
MCU Battery Backup Time (approx.) hr 2
Enclosure Cooling Convection
RF Connectors N-Female
Operating Temperature C -33 to +55
Operating Humidity  95%
Environmental Class IP65
MTBF hr ≥ 50,000

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 89 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-2 / 0314
900MHz + 1800MHz Digital Band Selective Repeater
RX-7539
Specifications-900MHz
Electrical 5W 10W
Frequency Range, Uplink MHz 885-915
Frequency Range, Downlink MHz 930-960
Operating Bandwidth Per Sub-band MHz 0.2-25
Number of Sub-bands 4
Total Output Power, Uplink dBm 27
Total Output Power, Downlink dBm 37 40
Maximum System Gain 90
Gain Adjustment Range (1dB step) dB 0-30
Pass Band Ripple at FBW, p-p dB 5
Uplink Noise Figure dB 5
System Group Delay sec  6.5
±600kHz dB ≥ 45
Out-of-Band Rejection@ GSM
±1MHz dB ≥ 60
Intermodulation@ GSM dBc ≥ 40
Absolute Maximum RF Input Power dBm -10
Input VSWR  1.5
Impedance  50
Note: Typical specifications at room temperature

Specifications-1800MHz
Electrical 5W 10W
Frequency Range, Uplink MHz 1710-1785
Frequency Range, Downlink MHz 1805-1880
Operating Bandwidth Per Sub-band MHz 0.2-25
Number of Sub-bands 4
Total Output Power, Uplink dBm 30
Total Output Power, Downlink dBm 37 40
Maximum System Gain 90
Gain Adjustment Range (1dB step) dB 0-30
Pass Band Ripple at FBW, p-p dB 5
Uplink Noise Figure dB 5
System Group Delay sec  6.5
Spurious Emission Mask
EVM Compliance with ETSI EN 301 908-15*
Out of Band Gain
±600kHz dB ≥ 45
Out-of-Band Rejection@ GSM
±1MHz dB ≥ 60
Intermodulation@ GSM dBc ≥ 40
Absolute Maximum RF Input Power dBm -10
Input VSWR  1.5
Impedance  50
Note: Typical specifications at room temperature,
*: Compliant to LTE standard @ UL 23dBm.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 90 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-1 / 1115
Specifications
Mechanical 5W 10W
Dimensions, H x W x D mm 440×408×355
Weight (approx.) kg 45
Power Supply 100-240/47-63Hz
Power Consumption (approx.) W 300 330
Power Up Waiting Time (approx.) sec 180
MCU Battery Backup Time (approx.) hr 2
Enclosure Cooling Convection
RF Connectors N-Female
Operating Temperature C -33 to +55
Operating Humidity  95%
Environmental Class IP65
MTBF hr ≥ 50,000

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 91 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-1 / 1115
900MHz + 2100MHz Digital Band Selective Repeater
RX-7639
Specifications-900MHz
Electrical 5W 10W
Frequency Range, Uplink MHz 885-915
Frequency Range, Downlink MHz 930-960
Operating Bandwidth Per Sub-band MHz 0.2-25
Number of Sub-bands 4
Total Output Power, Uplink dBm 27
Total Output Power, Downlink dBm 37 40
Maximum System Gain 90
Gain Adjustment Range (1dB step) dB 0-30
Pass Band Ripple at FBW, p-p dB 5
Uplink Noise Figure dB 5
System Group Delay sec  6.5
±600kHz dB ≥ 45
Out-of-Band Rejection@ GSM
±1MHz dB ≥ 60
Intermodulation@ GSM dBc ≥ 40
Absolute Maximum RF Input Power dBm -10
Input VSWR  1.5
Impedance  50
Note: Typical specifications at room temperature

Specifications-2100MHz
Electrical 5W 10W
Frequency Range, Uplink MHz 1920-1980
Frequency Range, Downlink MHz 2110-2170
Operating Bandwidth Per Sub-band 3-20*
Number of Sub-bands 4
Instantaneous Bandwidth MHz 30
Total Output Power, Uplink dBm 23
Total Output Power, Downlink dBm 37 40
Maximum System Gain 90
Gain Adjustment Range (1dB step) dB 0-30
Uplink Noise Figure dB 5
System Group Delay sec  6.5
Spurious Emission Mask
Compliance with 3GPP TS 25 106
EVM
Compliance with 3GPP TS 36 106
Out-of-Band Gain
Absolute Maximum RF Input Power dBm -10
Input VSWR  1.5
Impedance  50
Note: Typical specifications at room temperature
*: UMTS max bandwidth is 15MHz, LTE max bandwidth is 20MHz

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 92 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-4 / 1115
Specifications
Mechanical 5W 10W
Dimensions, H x W x D mm 440×408×355
Weight (approx.) kg 45
Power Supply 100-240/47-63Hz
Power Consumption (approx.) W 290 320
Power Up Waiting Time (approx.) sec 180
MCU Battery Backup Time (approx.) hr 2
Enclosure Cooling Convection
RF Connectors N-Female
Operating Temperature C -33 to +55
Operating Humidity  95%
Environmental Class IP65
MTBF hr ≥ 50,000

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 93 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-4 / 1115
1800MHz + 2100MHz Digital Band Selective Repeater
RX-7839
Specifications-1800MHz
Electrical 5W 10W
Frequency Range, Uplink MHz 1710-1785
Frequency Range, Downlink MHz 1805-1880
Operating Bandwidth Per Sub-band MHz 0.2-25
Number of Sub-bands 4
Total Output Power, Uplink dBm 30
Total Output Power, Downlink dBm 37 40
Maximum System Gain 90
Gain Adjustment Range (1dB step) dB 0-30
Pass Band Ripple at FBW, p-p dB 5
Uplink Noise Figure dB 5
System Group Delay sec  6.5
Spurious Emission Mask
EVM Compliance with ETSI EN 301 908-15*
Out of Band Gain
±600kHz dB ≥ 45
Out-of-Band Rejection@ GSM
±1MHz dB ≥ 60
Intermodulation@ GSM dBc ≥ 40
Absolute Maximum RF Input Power dBm -10
Input VSWR  1.5
Impedance  50
Note: Typical specifications at room temperature, *: Compliant to LTE standard @ UL 23dBm.

Specifications-2100MHz
Electrical 5W 10W
Frequency Range, Uplink MHz 1920-1980
Frequency Range, Downlink MHz 2110-2170
Operating Bandwidth Per Sub-band 3-20*
Number of Sub-bands 4
Instantaneous Bandwidth MHz 30
Total Output Power, Uplink dBm 23
Total Output Power, Downlink dBm 37 40
Maximum System Gain 90
Gain Adjustment Range (1dB step) dB 0-30
Uplink Noise Figure dB 5
System Group Delay sec  6.5
Spurious Emission Mask
Compliance with 3GPP TS 25 106
EVM
Compliance with 3GPP TS 36 106
Out-of-Band Gain
Absolute Maximum RF Input Power dBm -10
Input VSWR  1.5
Impedance  50
Note: Typical specifications at room temperature
*: UMTS max bandwidth is 15MHz, LTE max bandwidth is 20MHz

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 94 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-4 / 1115
Specifications
Mechanical 5W 10W
Dimensions, H x W x D mm 440×408×355
Weight (approx.) kg 45
Power Supply 100-240/47-63Hz
Power Consumption (approx.) W 310 330
MCU Battery Backup Time (approx.) hr 2
Enclosure Cooling Convection
RF Connectors N-Female
Operating Temperature C -33 to +55
Operating Humidity  95%
Environmental Class IP65
MTBF hr ≥ 50,000

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 95 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-4 / 1115
Tri-Band Digital Band Selective Repeater
RX-5239
Specifications-900MHz
Electrical 5W 10W
Frequency Range, Uplink MHz 885-915
Frequency Range, Downlink MHz 930-960
Operating Bandwidth Per Sub-band MHz 0.2-25
Number of Sub-bands 4
Total Output Power, Uplink dBm 27
Total Output Power, Downlink dBm 37 40
Maximum System Gain 90
Gain Adjustment Range (1dB step) dB 0-30
Pass Band Ripple at FBW, p-p dB 5
Uplink Noise Figure dB 5
System Group Delay sec  6.5
±600kHz dB ≥ 45
Out-of-Band Rejection@ GSM
±1MHz dB ≥ 60
Intermodulation@ GSM dBc ≥ 40
Absolute Maximum RF Input Power dBm -10
Input VSWR  1.5
Impedance  50
Note: Typical specifications at room temperature

Specifications-1800MHz
Electrical 5W 10W
Frequency Range, Uplink MHz 1710-1785
Frequency Range, Downlink MHz 1805-1880
Operating Bandwidth Per Sub-band MHz 0.2-25
Number of Sub-bands 4
Total Output Power, Uplink dBm 30
Total Output Power, Downlink dBm 37 40
Maximum System Gain 90
Gain Adjustment Range (1dB step) dB 0-30
Pass Band Ripple at FBW, p-p dB 5
Uplink Noise Figure dB 5
System Group Delay sec  6.5
Spurious Emission Mask
EVM Compliance with ETSI EN 301 908-15*
Out of Band Gain
±600kHz dB ≥ 45
Out-of-Band Rejection@ GSM
±1MHz dB ≥ 60
Intermodulation@ GSM dBc ≥ 40
Absolute Maximum RF Input Power dBm -10
Input VSWR  1.5
Impedance  50
Note: Typical specifications at room temperature, *: Compliant to LTE standard @ UL 23dBm.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 96 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-4 / 1115
Specifications-2100MHz
Electrical 5W 10W
Frequency Range, Uplink MHz 1920-1980
Frequency Range, Downlink MHz 2110-2170
Operating Bandwidth Per Sub-band 3-20*
Number of Sub-bands 4
Instantaneous Bandwidth MHz 30
Total Output Power, Uplink dBm 23
Total Output Power, Downlink dBm 37 40
Maximum System Gain 90
Gain Adjustment Range (1dB step) dB 0-30
Uplink Noise Figure dB 5
System Group Delay sec  6.5
Spurious Emission Mask
Compliance with 3GPP TS 25 106
EVM
Compliance with 3GPP TS 36 106
Out-of-Band Gain
Absolute Maximum RF Input Power dBm -10
Input VSWR  1.5
Impedance  50
Note: Typical specifications at room temperature
*: UMTS max bandwidth is 15MHz, LTE max bandwidth is 20MHz

Specifications
Mechanical 5W 10W
Dimensions, H x W x D mm 440×408×355
Weight (approx.) kg 45
Power Supply 100-240/47-63Hz
Power Consumption (approx.) W 420 480
Power Up Waiting Time (approx.) sec 180
MCU Battery Backup Time (approx.) hr 2
Enclosure Cooling Convection
Equipment N-Female
RF Connectors
Combiner (Option) Din-Female
Operating Temperature C -33 to +55
Operating Humidity  95%
Environmental Class IP65
MTBF hr ≥ 50,000

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 97 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-4 / 1115
RX Series Digital Channel Selective Repeater
RX-2123 III3

Features
 Utilizing the latest Pre-distortion MCPA technologies, up to 20W Downlink Power Output
in a compact chassis (20L).
 2W/5W/10W/20W total output power.
 Automatic Digital gain control and Antenna Feedback Cancellation (AFC) feature
that can reduce the isolation requirement up to 30dB.
 Support up to 4 WCDMA channels with independent ON/OFF switch.
 Integrated wireless modem for remote configuration, monitoring and control.
 Offline isolation detection for easy commissioning.
 Internal backup battery keeps the alarm unit running for up to two hours after power failure.
 Compatible to Comba generic OMT and CMS platform.
 Designed for all weather outdoor installation – waterproof, damp-proof and omni-sealed (IP65).
 Can be configured as Master Unit (MU) or Slave Unit (SU) in a centralized monitoring system.

Functional Block Diagram

LNA1 PA1

Mobile
Donor Ant
Ant Integrated Frequency
DT selective module MT

Mobile

BTS PA2 LNA2

OMT
Computer with
Data card

Alarm Power Li-ion


Indicator Main Control Unit Supply BATT
Wireless Modem
Modem

OMC
External
OMT Power

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 98 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-1 / 0414
Specifications
Electrical 2W 5W 10W 20W
Frequency Range, Uplink MHz 1920-1980
Frequency Range, Downlink MHz 2110-2170
Number of Channels 4
Total Output Power, Uplink dBm 23
Total Output Power, Downlink dBm 33 37 40 43
Maximum System Gain dB 105
Gain Adjustment Range (1dB step) dB 0-30
Antenna Feedback Cancellation dB 30
Uplink Noise Figure dB 5
System Group Delay sec  11
Spectrum Emission Mask
ACRR
EVM Compliance with 3GPP TS 25.106
PCDE
Intermodulation
Absolute Maximum RF Input Power dBm -10
Input VSWR  1.5
Impedance  50
Mechanical
Dimensions, H x W x D mm 430 x 300 x 164
Weight (approx.) kg 18
VAC 100-240/47-63Hz
Power Supply
VDC -68 to -38
Power Consumption (approx.) W 120 130 160 180
Power Up Waiting Time (approx.) sec 180
MCU Battery Backup Time (approx.) hr 2
Enclosure Cooling Convection
RF Connectors N-Female
Operating Temperature C -33 to +55
Operating Humidity  95%
Environmental Class IP65
MTBF hr ≥ 50,000
Note: Typical specification at room temperature

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 99 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-1 / 0414
800MHz Digital Channel Selective Repeater
RX-0823

Features
 Support 5/10/15/20MHz different bandwidth LTE carrier
 Power Output software adjustable, up to 20W Downlink Power Output.
 Automatic Digital gain control and Antenna Feedback Cancellation (AFC) feature
that can reduce the isolation requirement up to 30dB.
 Integrated WCDMA wireless modem for remote configuration, monitoring and control.
 Offline isolation detection for easy commissioning.
 Compatible to Comba generic OMT and CMS platform.
 Designed for all weather outdoor installation – waterproof, damp-proof and omni-sealed (IP65).

Functional Block Diagram

LNA1 PA1

Mobile
Donor Ant
Ant Integrated Frequency
DT selective module MT

Mobile

BTS PA2 LNA2

OMT
Computer with
Data card

Alarm Power Li-ion


Indicator Main Control Unit Supply BATT
Wireless Modem
Modem

OMC
External
OMT Power

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 100 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-1 / 0414
Specifications
Electrical 5W 10W 20W
Frequency Range, Uplink MHz 832-862
Frequency Range, Downlink MHz 791-821
Operating Bandwidth MHz 5/10/15/20 (5MHz Step)
Total Output Power, Uplink dBm 23
Total Output Power, Downlink dBm 37 40 43
Maximum System Gain dB 100
Gain Adjustment Range (1dB step) dB 0-30
Antenna Feedback Cancellation dB 30
Uplink Noise Figure dB 5
System Group Delay sec  6.5
Spectrum Emission Mask
ACRR
EVM Compliance with 3GPP TS 36.106
PCDE
Intermodulation
Absolute Maximum RF Input Power dBm -10
Input VSWR  1.5
Impedance  50
Mechanical
Dimensions, H x W x D mm 430 x 300 x 164
Weight (approx.) kg 18
Power Supply VAC 100-240/47-63Hz
Power Consumption (approx.) W 130 140 150
Power Up Waiting Time (approx.) sec 180
MCU Battery Backup Time (approx.) hr 2
Enclosure Cooling Convection
RF Connectors N-Female
Operating Temperature C -33 to +55
Operating Humidity  95%
Environmental Class IP65
MTBF hr ≥ 50,000
Note: Typical specification at room temperature

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 101 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-1 / 0414
2100MHz Digital Channel Selective Repeater
RX-2123 IV4

Features
 Support 5/10/15/20MHz different bandwidth LTE carrier
 Power Output software adjustable, up to 20W Downlink Power Output.
 Automatic Digital gain control and Antenna Feedback Cancellation (AFC) feature
that can reduce the isolation requirement up to 30dB.
 Integrated WCDMA wireless modem for remote configuration, monitoring and control.
 Offline isolation detection for easy commissioning.
 Compatible to Comba generic OMT and CMS platform.
 Designed for all weather outdoor installation – waterproof, damp-proof and omni-sealed (IP65).

Functional Block Diagram

LNA1 PA1

Mobile
Donor Ant
Ant Integrated Frequency
DT selective module MT

Mobile

BTS PA2 LNA2

OMT
Computer with
Data card

Alarm Power Li-ion


Indicator Main Control Unit Supply BATT
Wireless Modem
Modem

OMC
External
OMT Power

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 102 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-1 / 0414
Specifications
Electrical 5W 10W 20W
Frequency Range, Uplink MHz 1920-1980
Frequency Range, Downlink MHz 2110-2170
Operating Bandwidth MHz 5/10/15/20
Total Output Power, Uplink dBm 23
Total Output Power, Downlink dBm 37 40 43
Maximum System Gain dB 100
Gain Adjustment Range (1dB step) dB 0-30
Antenna Feedback Cancellation dB 30
Uplink Noise Figure dB 5
System Group Delay sec  6.5
Spectrum Emission Mask
ACRR
EVM Compliance with 3GPP TS 36.106
PCDE
Intermodulation
Absolute Maximum RF Input Power dBm -10
Input VSWR  1.5
Impedance  50
Mechanical
Dimensions, H x W x D mm 430 x 300 x 164
Weight (approx.) kg 18
Power Supply VAC 100-240/47-63Hz
Power Consumption (approx.) W 140 150 160
MCU Battery Backup Time (approx.) hr 2
Enclosure Cooling Convection
RF Connectors N-Female
Operating Temperature C -33 to +55
Operating Humidity  95%
Environmental Class IP65
MTBF hr ≥ 50,000
Note: Typical specification at room temperature

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 103 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-1 / 0414
Operation and Maintenance
 Using a direct connection to a PC by RJ45, installation and commissioning of the device is accomplished by the OMT. Using the integrated
wireless modem, the equipment parameters can be monitored and controlled remotely.
 Controlled equipment parameters include: RF Switch, Carrier Switch, Channel No. Range, ATT, Over-Temp Threshold, DL Input Power
Threshold, DL Output Power Threshold and Alarm Report Enable.
 Monitored equipment parameters include: Alarms (LNA, PA, PLL unlock, Power Down, PSU Fault, Door Open, DL Input power Overload, DL
Output Power Low, Over Temp, VSWR), DL Output Power and DL Input Power.
 The device has been developed to take advantage of advanced network operation, where the CMS (optional) provides an effective solution
for central monitoring of a group of Comba products.

Outline Drawing

300 164

RUN

ALM

MODEM
430

AC 100V-240V
50/60Hz AC OUT
RS-485 EXT_ALM MODEM ANT

DT MT

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 104 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-1 / 0414
800MHz Digital Channel Selective Repeater
RX-0823

Features
 Support 5/10/15/20MHz different bandwidth LTE carrier
 Power Output software adjustable, up to 20W Downlink Power Output.
 Automatic Digital gain control and Antenna Feedback Cancellation (AFC) feature
that can reduce the isolation requirement up to 30dB.
 Integrated WCDMA wireless modem for remote configuration, monitoring and control.
 Offline isolation detection for easy commissioning.
 Compatible to Comba generic OMT and CMS platform.
 Designed for all weather outdoor installation – waterproof, damp-proof and omni-sealed (IP65).

Functional Block Diagram

LNA1 PA1

Mobile
Donor Ant
Ant Integrated Frequency
DT selective module MT

Mobile

BTS PA2 LNA2

OMT
Computer with
Data card

Alarm Power Li-ion


Indicator Main Control Unit Supply BATT
Wireless Modem
Modem

OMC
External
OMT Power

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 105 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-1 / 0414
900MHz Digital Channel Selective Repeater
RX-9123

Features
 Up to 12 GSM Channels
 Digitalized Antenna Feedback Cancellation (AFC) function to reduce
the antenna isolation requirement up to 30dB.
 Dynamic Uplink Noise Control (UNC) function to reduce Uplink Interference by
automatically switch off the corresponding carriers when no traffic.
 5W/10W Downlink Output Power utilizing ultra Linear PA, supports GSM, GPRS and EDGE.
 Integrated wireless modem for remote configuration, monitoring and control.
 Internal backup battery keeps the alarm unit running for up to two hours after power failure.
 Compatible to Comba generic OMT and CMS platform.
 Designed for all weather outdoor installation – waterproof, damp-proof and omni-sealed (IP65).

Functional Block Diagram

LNA1 PA1

Mobile
Donor Ant
Ant Integrated Frequency
DT selective module MT

Mobile

BTS PA2 LNA2

OMT
Computer with
Data card

Alarm Power Li-ion


Indicator Main Control Unit Supply BATT
Wireless Modem
Modem

OMC
External
OMT Power

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 106 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-1 / 0414
Specifications
Electrical 5W 10W
Frequency Range, Uplink MHz 890-915
Frequency Range, Downlink MHz 935-960
Number of Channels 4/8/12
Total Output Power, Uplink dBm 33
Total Output Power, Downlink dBm 37 40
Maximum System Gain dB 100
Gain Adjustment Range (1dB Step) dB 0-30
Antenna Feedback Cancellation dB 30
Uplink Noise Figure dB 5
System Group Delay sec  11
Intermodulation dBc ≥ 40
at ±400KHz dB > 50
Channel Selectivity at ±600KHz dB > 55
at ±1MHz dB > 60
In Band Spurious 890-915 /935-960MHz dBc  -60
9KHz to 1GHz dBm  -36
Out of Band Spurious
1GHz to 12.75GHz dBm  -30
Absolute Maximum RF Input Power dBm -10
Input VSWR  1.5
Impedance  50
Mechanical
Dimensions, H x W x D mm 420 x 330 x 182
Weight (approx.) kg 25
VAC 100-240/47-63Hz
Power Supply
VDC -68 to -38
Power Consumption (approx.) W 160 170
Power Up Waiting Time (approx.) sec 180
MCU Battery Backup Time (approx.) hr 2
Enclosure Cooling Convection
RF Connectors N-Female
Operating Temperature °C -33 to +55
Operating Humidity  95%
Environmental Class IP65
MTBF hr ≥ 50,000
Note: Typical specifications at room temperature

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 107 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-1 / 0414
Operation and Maintenance
 Using a direct connection to a PC by RJ45, installation and commissioning of the RX-9123 is accomplished by
the OMT. Using the integrated wireless modem, the equipment parameters can be monitored and controlled
remotely.
 Controlled equipment parameters include: RF Switch, Carrier Switch, Channel No. Range, ATT, Over-Temp
Threshold, DL Input Power Threshold, DL Output Power Threshold and Alarm Report Enable.
 Monitored equipment parameters include: Alarms (LNA, PA, PLL unlock, Power Down, PSU Fault, Door Open,
DL Input power Overload, DL Output Power Low, Over Temp, VSWR), DL Output Power and DL Input Power.
 The RX-9123 has been developed to take advantage of advanced network operation, where the CMS (optional)
provides an effective solution for central monitoring of a group of Comba products.

Outline Drawing

420

330
182

227

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 108 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-1 / 0414
700/800MHz Public Safety Bi-directional Amplifier
RX-7W22

Features
 Dual-band configuration supports 700MHz and 800MHz public safety bands.
 Each band supports up to 32 channels.
 2W output power for each band.
 Channelized Auto Gain Control (AGC).
 Channelized uplink squelch supported.
 Web based GUI for intelligent configuration, SNMP supported.
 Built-in mandatory isolation test to prevent BDA oscillation.
 NFPA compliant dry contact alarms, NEMA 4 enclosure.

Specifications
Electrical 700MHz 800MHz
Frequency Range, Uplink MHz 799-805 806-824
Frequency Range, Downlink MHz 769-775 851-869
Channel Bandwidth KHz 12.5/25 12.5/25
Number of Channels 32 32
Total Output Power, Uplink dBm 25
Total Output Power, Downlink dBm 33 33
Maximum System Gain dB 90 90
Gain Adjustment Range (1dB step) dB 0-30 0-30
Pass Band Ripple, p-p dB 5 5
Uplink Noise Figure dB 5 5
System Group Delay sec 10-35 10-35
Intermodulation dBm  -13  -13
at  50KHz dBc ≥ 20 ≥ 20
Out-of-Band
at  70KHz dBc ≥ 40 ≥ 40
Suppression( Delay :35sec)
at  1MHz dBc ≥ 60 ≥ 60
9kHz to 1GHz dBm
Spurious FCC Compliance FCC Compliance
1GHz to 12.75GHz dBm
Absolute Maximum RF Input Power dBm -10 -10
Input VSWR  1.5  1.5
Impedance  50 50
Mechanical
Dimensions, H x W x D mm(in) 530 x 390 x 210 (20.9 x 15.4 x 8.3)
Weight (approx.) Kg(lb) 23 (50.7)
Power Supply VAC 100-240/47-63Hz
Power Consumption Single band W 60 Single band
(approx.) Dual bands W 120 Dual bands
Power Up Waiting Time (approx.) sec 180
Enclosure Cooling Convection
RF Connectors N-Female
o
Operating Temperature C(oF) -33 to +60 (-27 to +140)
Operating Humidity  95%
Environmental Class NEMA 4
Note: Typical specifications at room temperature,

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 109 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-10/ 0316
Outline Drawing

210 (8.3)
DL

(6.1)
155
OMT LAN DT RUN ALM MT UL

AC 100V-240V DRY1 DRY2 AUX


50Hz/60Hz

390 (15.4)

480 (18.9)
530 (20.9)

Part Numbers
Product Type P/N
Single band 700MHz RX7W22-07-H32V0P33A92
Single band 800MHz RX7W22-08-H32V0P33A92
Dual band 700/800MHz RX7W22-78-H32V0P33A92
700MHz license RX7W22-L7-H32V0P33A92
800MHz license RX7W22-L8-H32V0P33A92

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 110 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-10/ 0316
800MHz Tetra Band Selective Repeater
RX-8039
Specifications
Electrical 2W 5W 10W
Frequency Range, Uplink MHz 806-824
Frequency Range, Downlink MHz 851-869
Operating Bandwidth Per Sub-band MHz 0.2-18
Number of Sub-bands 4
Total Output Power, Uplink dBm 30
Total Output Power, Downlink dBm 33 37 40
Maximum System Gain dB 90
Gain Adjustment Range (1dB step) dB 0-30
Pass Band Ripple, p-p dB 5
Uplink Noise Figure dB 5
System Group Delay sec  6.5
Intermodulation dBc ≥ 40
±600kHz dBc ≥ 45
Out-of-Band Suppression
±1MHz dBc ≥ 60
9KHz to 1GHz dBm  -36
Spurious
1GHz to 12.75GHz dBm  -30
Absolute Maximum RF Input Power dBm -10
Input VSWR  1.5
Impedance  50
Mechanical
Dimensions, H x W x D mm 430 x 300 x 164
Weight (approx.) kg 18
Power Supply VAC 100-240/47-63Hz
Power Consumption (approx.) W 120 140 160
Power Up Waiting Time (approx.) sec 180
MCU Battery Backup Time (approx.) hr 2
Enclosure Cooling Convection
RF Connectors N-Female
Operating Temperature C -33 to +55
Operating Humidity  95%
Environmental Class IP65
MTBF hr ≥ 50,000
Note: Typical specifications at room temperature

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 111 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-10/ 0316
mBDA Series Digital Band Selective Repeater
Features
 Up to 3 pass band segments with independent ON/OFF for maximum flexibility.
 Max. 2W total output power.
 Offline isolation detection for easy commissioning.
 Friendly and easy OMT interface via RJ45 connection
 Integrated wireless modem for remote monitoring and control.
 Compatible to Comba generic OMT and CMS platform.
 Waterproof, damp-proof and omni-sealed (IP65).

Functional Block Diagram

LNA1 PA1

Mobile
Donor Ant
Ant Integrated Frequency
DT selective module MT

Mobile

BTS PA2 LNA2

Alarm Power Li-ion


Indicator Main Control Unit Supply BATT
Wireless Modem
Modem

OMC
External
OMT Power

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 112 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-0 / 0116
700MHz Digital Band Selective Repeater
mBDA-0733
Specifications
Electrical 0.5W 1W 2W
Operating Frequency, Uplink MHz 703-733
Operation Frequency, Downlink MHz 758-788
Operating Bandwidth Per Sub-band MHz 3-20
Number of Sub-bands 3
Total Output Power, Uplink dBm 17
Total Output Power, Downlink dBm 27 30 33
Maximum System Gain dB 80
Attenuation Adjustment Range (1dB step) dB 0-30
Pass Band Ripple at FBW, p-p dB ≤4
Uplink Noise Figure dB 5
System Group Delay sec ≤6
Out-of-Band Gain
Input Intermodulation
Compliance with 3GPP TS 36.106
Spurious Emission
EVM
ACRR
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 1.6
Impedance  50
Mechanical
Dimensions, W x H x D mm 350 x 220 x 100
Weight (approx.) kg 7
Power Supply VAC 100-240/47-63Hz
Power Consumption (approx.) W 60
Enclosure Cooling Convection
RF Connectors N-Female
Operating Temperature C -33 to +55
Operating Humidity  95%
Environmental Class IP65
MTBF hr > 50,000
Note: Typical specification at room temperature.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 113 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-2 / 0315
L30M
800MHz Digital Band Selective Repeater
mBDA-0833
Specifications
Electrical 0.5W 1W 2W
Operating Frequency, Uplink MHz 832-862
Operation Frequency, Downlink MHz 791-821
Operating Bandwidth Per Sub-band MHz 0.2-20
Number of Sub-bands 3
Total Output Power, Uplink dBm 17
Total Output Power, Downlink dBm 27 30 33
Maximum System Gain dB 80
Attenuation Adjustment Range (1dB step) dB 0-30
Pass Band Ripple at FBW, p-p dB ≤4
Uplink Noise Figure dB 5
System Group Delay sec ≤6
Out-of-Band Gain
Intermodulation
Spurious Emission
Compliance with 3GPP TS 36.106
EVM
ACRR
PCDE
Spurious Emission Mask
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 1.6
Impedance  50
Mechanical
Dimensions, W x H x D mm/in 361 x 222 x 93/14.2 x 8.7 x 3.7
Weight (approx.) kg/lb 7/15.4
Power Supply VAC 100-240/47-63Hz
Power Consumption (approx.) W 60
Enclosure Cooling Convection
RF Connectors N-Female
Operating Temperature C -33 to +55
Operating Humidity  95%
Environmental Class IP65
MTBF hr > 50,000
Note: Typical specification at room temperature.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 114 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-0 / 0116
900MHz Digital Band Selective Repeater
mBDA-9133
Specifications
Electrical 0.5W 1W 2W
Operating Frequency, Uplink MHz 885-915
Operation Frequency, Downlink MHz 930-960
Operating Bandwidth Per Sub-band MHz 0.2-25*
Number of Sub-bands 3
Total Output Power, Uplink dBm 23
Total Output Power, Downlink dBm 27 30 33
Maximum System Gain dB 80
Attenuation Adjustment Range (1dB step) dB 0-30
Pass Band Ripple at FBW, p-p dB ≤4
Uplink Noise Figure dB 5
System Group Delay sec ≤6
Out-of-Band Gain
Intermodulation
Spurious Emission
EVM Compliance with 3GPP TS 25.106
ACRR
PCDE
Spurious Emission Mask
Offset ≥ 600KHz ≥ 45
Out-of-Band Rejection @ GSM dBc
Offset ≥ 1MHz ≥ 60
Intermodulation @ GSM dBm ≤ -13
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 1.6
Impedance  50
Mechanical
Dimensions, W x H x D mm/in 361 x 222 x 93/14.2 x 8.7 x 3.7
Weight (approx.) kg/lb 7/15.4
Power Supply VAC 100-240/47-63Hz
Power Consumption (approx.) W 60
Enclosure Cooling Convection
RF Connectors N-Female
Operating Temperature C -33 to +55
Operating Humidity  95%
Environmental Class IP65
MTBF hr > 50,000
Note: Typical specification at room temperature;
*: GSM Max. Bandwidth 25MHz, WCDMA Max. Bandwidth 15MHz.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 115 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-3 / 0714
1800MHz Digital Band Selective Repeater
mBDA-1833
Specifications
Electrical 0.5W 1W 2W
Operating Frequency, Uplink MHz 1710-1785
Operation Frequency, Downlink MHz 1805-1880
Operating Bandwidth Per Sub-band MHz 0.2-25*
Number of Sub-bands 3
Total Output Power, Uplink dBm 23
Total Output Power, Downlink dBm 27 30 33
Maximum System Gain dB 80
Attenuation Adjustment Range (1dB step) dB 0-30
Pass Band Ripple at FBW, p-p dB ≤4
Uplink Noise Figure dB 5
System Group Delay sec ≤6
Out-of-Band Gain
Spurious Emission
EVM
ACRR Compliance with 3GPP TS 36.106
PCDE
Spurious Emission Mask
Intermodulation
Offset ≥ 600KHz ≥ 45
Out-of-Band Rejection @ GSM dBc
Offset ≥ 1MHz ≥ 60
Intermodulation @ GSM dBm ≤ -13
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 1.6
Impedance  50
Mechanical
Dimensions, W x H x D mm/in 361 x 222 x 93/14.2 x 8.7 x 3.7
Weight (approx.) kg/lb 7/15.4
Power Supply VAC 100-240/47-63Hz
Power Consumption (approx.) W 60
Enclosure Cooling Convection
RF Connectors N-Female
Operating Temperature C -33 to +55
Operating Humidity  95%
Environmental Class IP65
MTBF hr > 50,000
Note: Typical specification at room temperature;
*: GSM Max. Bandwidth 25MHz, LTE Max. Bandwidth 20MHz.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 116 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-3 / 0714
1900MHz Digital Band Selective Repeater
mBDA-1933
Specifications
Electrical 0.5W 1W 2W
Operating Frequency, Uplink MHz 1850-1915
Operation Frequency, Downlink MHz 1930-1995
Operating Bandwidth Per Sub-band MHz 0.2-25*
Number of Sub-bands 3
Total Output Power, Uplink dBm 23
Total Output Power, Downlink dBm 27 30 33
Maximum System Gain dB 80
Attenuation Adjustment Range (1dB step) dB 0-30
Pass Band Ripple at FBW, p-p dB ≤4
Uplink Noise Figure dB 5
System Group Delay sec ≤6
Out-of-Band Gain
Intermodulation
Spurious Emission
Compliance with 3GPP TS 25.106 @ WCDMA
EVM
Compliance with 3GPP TS 36.106 @ LTE
ACRR
PCDE
Spurious Emission Mask
Offset ≥ 600KHz ≥ 45
Out-of-Band Rejection @ GSM dBc
Offset ≥ 1MHz ≥ 60
Intermodulation @ GSM dBm ≤ -13
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 1.6
Impedance  50
Mechanical
Dimensions, W x H x D mm/in 361 x 222 x 93/14.2 x 8.7 x 3.7
Weight (approx.) kg/lb 7/15.4
Power Supply VAC 100-240/47-63Hz
Power Consumption (approx.) W 60
Enclosure Cooling Convection
RF Connectors N-Female
Operating Temperature C -33 to +55
Operating Humidity  95%
Environmental Class IP65
MTBF hr > 50,000
Note: Typical specification at room temperature;
*: GSM/CDMA Max. Bandwidth 25MHz, WCDMA Max. Bandwidth 15MHz, LTE Max. Bandwidth 20MHz.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 117 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-2 / 0714
AWS Digital Band Selective Repeater
mBDA-2033
Specifications
Electrical 0.5W 1W 2W
Operating Frequency, Uplink MHz 1710-1755
Operation Frequency, Downlink MHz 2110-2155
Operating Bandwidth Per Sub-band MHz 3-20*
Number of Sub-bands 3
Total Output Power, Uplink dBm 17
Total Output Power, Downlink dBm 27 30 33
Maximum System Gain dB 80
Attenuation Adjustment Range (1dB step) dB 0-30
Pass Band Ripple at 3.84MHz dB ≤2
Uplink Noise Figure dB 5
System Group Delay sec ≤6
Out-of-Band Gain
Intermodulation
Spurious Emission
Compliance with 3GPP TS 25.106 @ WCDMA
EVM Compliance with 3GPP TS 36.106 @ LTE
ACRR
PCDE
Spurious Emission Mask
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 1.6
Impedance  50
Mechanical
Dimensions, W x H x D mm/in 361 x 222 x 93/14.2 x 8.7 x 3.7
Weight (approx.) kg/lb 7/15.4
Power Supply VAC 100-240/47-63Hz
Power Consumption (approx.) W 60
Enclosure Cooling Convection
RF Connectors N-Female
Operating Temperature C -33 to +55
Operating Humidity  95%
Environmental Class IP65
MTBF hr > 50,000
Note: Typical specification at room temperature;
*: WCDMA Max. Bandwidth 15MHz, LTE Max. Bandwidth 20MHz.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 118 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-4 / 1115
2100MHz Digital Band Selective Repeater
mBDA-2133
Specifications
Electrical 0.5W 1W 2W
Operating Frequency, Uplink MHz 1920-1980
Operation Frequency, Downlink MHz 2110-2170
Operating Bandwidth Per Sub-band MHz 0.2-20*
Number of Sub-bands 3
Total Output Power, Uplink dBm 17
Total Output Power, Downlink dBm 27 30 33
Maximum System Gain dB 80
Attenuation Adjustment Range (1dB step) dB 0-30
Pass Band Ripple at 3.84MHz dB ≤2
Uplink Noise Figure dB 5
System Group Delay sec ≤6
Out-of-Band Gain
Intermodulation
Spurious Emission
Compliance with 3GPP TS 25.106 @ WCDMA
EVM Compliance with 3GPP TS 36.106 @ LTE
ACRR
PCDE
Spurious Emission Mask
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 1.6
Impedance  50
Mechanical
Dimensions, W x H x D mm/in 361 x 222 x 93/14.2 x 8.7 x 3.7
Weight (approx.) kg/lb 7/15.4
Power Supply VAC 100-240/47-63Hz
Power Consumption (approx.) W 60
Enclosure Cooling Convection
RF Connectors N-Female
Operating Temperature C -33 to +55
Operating Humidity  95%
Environmental Class IP65
MTBF hr > 50,000
Note: Typical specification at room temperature;
*: WCDMA Max. Bandwidth 15MHz, LTE Max. Bandwidth 20MHz.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 119 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-3 / 0714
2600MHz Digital Band Selective Repeater
mBDA-2633
Specifications
Electrical 0.5W 1W 2W
Operating Frequency, Uplink MHz 2500-2570
Operation Frequency, Downlink MHz 2620-2690
Operating Bandwidth Per Sub-band MHz 3-20
Number of Sub-bands 3
Total Output Power, Uplink dBm 17
Total Output Power, Downlink dBm 27 30 33
Maximum System Gain dB 80
Attenuation Adjustment Range (1dB step) dB 0-30
Pass Band Ripple at FBW, p-p dB ≤4
Uplink Noise Figure dB 5
System Group Delay sec ≤6
Out-of-Band Gain
Input Intermodulation
Compliance with 3GPP TS 36.106
Spurious Emission
EVM
ACRR
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 1.6
Impedance  50
Mechanical
Dimensions, W x H x D mm/in 361 x 222 x 93/14.2 x 8.7 x 3.7
Weight (approx.) kg/lb 7/15.4
Power Supply VAC 100-240/47-63Hz
Power Consumption (approx.) W 60
Enclosure Cooling Convection
RF Connectors N-Female
Operating Temperature C -33 to +55
Operating Humidity  95%
Environmental Class IP65
MTBF hr > 50,000
Note: Typical specification at room temperature.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 120 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-2 / 0714
Combiner for Dual Single Band mBDAs
Features
 Combiner is used for mBDA single band enclosure
 Single in and single out
 Uniform for the whole system
 Easy installation

Specifications-model 1
Electrical Band1 Band2
Operating Frequency (MHz) 806-960 1710-2170
Insert Loss (dB) ≤ 0.8 ≤1
VSWR ≤ 1.5 ≤ 1.5
Note: Typical specification at room temperature;

Specifications-model 2
Electrical Band1 Band2
Operating Frequency (MHz) 1710-1880 1920-2170
Insert Loss (dB) ≤ 1.1 ≤ 1.1
VSWR ≤ 1.5 ≤ 1.5
Note: Typical specification at room temperature;

Mechanical
Dimensions, H x W x D (mm) 210 x 338 x 71
Weight (approx.) (kg) 4.6
RF Connectors N-Female
Operating Temperature (C) -33 to +55
Operating Humidity  95%
Environmental Class IP65

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 121 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-2 / 0216
Outline Drawing

102
338
71

210
Combiner

Wall

Master Unit

Slave Unit

Combiner

Final Show-After Combination

Note: mBDA equipments are not included, need order separately.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 122 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-2 / 0216
mBDA Indoor Digital Band Selective Repeater
mBDA-100
Features
 Max. 4 bands of 700/800/900/1800/2100/2600MHz.
 Supports GSM, WCDMA, and LTE operating.
 Supports multi operator configurations and up to 3 sub bands per band.
 Operation via OMT software.
 Friendly and easy OMT interface via RJ45 connection
 Integrated wireless modem or Ethernet for remote monitoring and control.

Product Description
mBDA is a wireless enhanced solution where high-quality voice or high-speed data service is not available between
a mobile and a base station. mBDA is ideal for the first phase of the network rollout and for any subsequent phase
where cost, coverage, and quality need to be optimized.

mBDA offers a modular, robust design that is easy to install, manage and upgrade. It supports three individually
adjustable sub-bands for flexibility and high RF performance, supports multi-carrier and multi-band operation.

Remote configuration and surveillance is possible through Comba’s remote control and monitoring system via PC or
wireless modem to the OMT/OMC.

Support Technologies
Frequency Range (MHz)
Band Technologies Downlink (DL) Uplink (UL)
700MHz LTE 703-733 758-788
800MHz LTE 791-821 832-862
900MHz GSM/WCDMA 930-960 885-915
1800MHz GSM/LTE 1805-1880 1710-1785
2100MHz WCDMA 2110-2170 1920-1980
2600MHz LTE 2620-2690 2500-2570

WCDMA complies with 3GPP TS 25.106 V9.0.0 (2009-12) table 9.2, 9.3, 9.4 spectrum emission mask.
LTE service is based on 3GPP TS 36.106 V9.0.0 (2009-12)

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 123 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-7 / 0216
RF Parameter
LTE 700 MHz GSM/WCDMA* 900 MHz
RF Parameter DL UL RF Parameter DL UL
Frequency Range (MHz) 703-733 758-788 Frequency Range (MHz) 930-960 885-915
Max Output Power Per Antenna Port Max Output Power Per Antenna Port
1(Composite) 27, 30, 33 17 1(Composite) 27, 30, 33 23
2 Carriers -3 / 2 Carriers -3 /
4 Carriers -6 / 4 Carriers -6 /
8 Carriers -9 / 8 Carriers -9 /
Sub-bands 3 3 Sub-bands 3 3
Operating Bandwidth (MHz) 3-20 3-20 Operating Bandwidth (MHz) 0.2-24.8 0.2-24.8
Maximum System Gain (dB) 80 80 Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4 Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) / 5 System Noise Figure (dB) / 5
System Group Delay (sec) 6 6 System Group Delay (sec) 6 6
Gain Adjustable Range 0-30 0-30 Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP Emission Mask 3GPP 3GPP
1
Intermodulation 3GPP 3GPP Intermodulation 3GPP 3GPP

LTE 800 MHz GSM/LTE** 1800 MHz


RF Parameter DL UL RF Parameter DL UL
Frequency Range (MHz) 791-821 832-862 Frequency Range (MHz) 1805-1880 1710-1785
Max Output Power Per Antenna Port Max Output Power Per Antenna Port
1(Composite) 27, 30, 33 17 1(Composite) 27, 30, 33 23
2 Carriers -3 / 2 Carriers -3 /
4 Carriers -6 / 4 Carriers -6 /
8 Carriers -9 / 8 Carriers -9 /
Sub-bands 3 3 Sub-bands 3 3
Operating Bandwidth (MHz) 3-20 3-20 Operating Bandwidth (MHz) 0.2-25 0.2-25
Maximum System Gain (dB) 80 80 Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4 Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) / 5 System Noise Figure (dB) / 5
System Group Delay (sec) 6 6 System Group Delay (sec) 6 6
Gain Adjustable Range 0-30 0-30 Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP Emission Mask 3GPP 3GPP
2
Intermodulation 3GPP 3GPP Intermodulation 3GPP 3GPP

*WCDMA complies with 3GPP TS 25.106 V9.0.0 (2009-12) table 9.2, 9.3, 9.4 spectrum emission mask.
**LTE service is based on 3GPP TS 36.106 V9.0.0 (2009-12)
1
Intermodulation: WCDMA@3GPP; GSM @Less than-13dBm.
2
Intermodulation: LTE@3GPP; GSM @Less than-13dBm.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 124 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-7 / 0216
RF Parameter (continued)
WCDMA 2100 MHz LTE 2600 MHz
RF Parameter DL UL RF Parameter DL UL
Frequency Range (MHz) 2110-2170 1920-1980 Frequency Range (MHz) 2620-2690 2500-2570
Max Output Power Per Antenna Port Max Output Power Per Antenna Port
1(Composite) 27, 30, 33 17 1(Composite) 27, 30, 33 17
2 Carriers -3 / 2 Carriers -3 /
4 Carriers -6 / 4 Carriers -6 /
8 Carriers -9 / 8 Carriers -9 /
Sub-bands 3 3 Sub-bands 3 3
Operating Bandwidth (MHz) 5,10,15 5,10,15 Operating Bandwidth (MHz) 3-20 3-20
Maximum System Gain (dB) 80 80 Maximum System Gain (dB) 80 80
Pass Band Ripple at 3.84MHz 2 2 Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) / 5 System Noise Figure (dB) / 5
System Group Delay (sec) 6 6 System Group Delay (sec) 6 6
Gain Adjustable Range 0-30 0-30 Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP Emission Mask 3GPP 3GPP
Intermodulation 3GPP 3GPP Intermodulation 3GPP 3GPP

Combiner Specifications
Electrical Band1 Band2 Band3 Band4
Operating Frequency (MHz) 791-960 1710-1880 1920-2170 2500-2690
Insert Loss (dB) ≤ 0.8 ≤ 0.9 ≤ 0.9 ≤ 0.8
VSWR ≤ 1.5 ≤ 1.5 ≤ 1.5 ≤ 1.5

Mechanical Specifications
Dimensions, H x W x D, mm (in) System Rack (4 bands) 267 x 482 x 485, (10.5 x 19 x 19.1)
Power and Monitor Unit 220 x 80 x 440, (8.7 x 3.1 x 17.3)
Combiner Unit 220 x 60 x 230, (8.7 x 2.4 x 9.1)
RF Unit 220 x 60 x 350, (8.7 x 2.4 x 13.8)
System Rack (4 bands) 13.2, (29.1)
Power & Monitoring Unit 4, (8.8)
Weight, kg (lb) (approx.)
Combiner Unit 4, (8.8)
RF Card 3.8, (8.4)
Power & Monitoring Unit 15
Power Consumption, W (approx.)
RF Unit 50
Power Supply 100-240VAC/47-63Hz
Power Up Waiting Time (sec) (approx.) 180
Enclosure Cooling Convection or Fan
RF Connectors N Female
Operating Temperature (°C ) -20 to +40
Operating Humidity 10% to 85%
Environmental Class IP30
MTBF ( hr) ≥ 50,000
Mounting 19” Rack

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 125 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-7 / 0216
mBDA Indoor Digital Band Selective Repeater
mBDA-200S
Features
 Max. 6 bands of 700UpperC/700LowerABC/850/1900/AWS/2600MHz.
 Supports GSM, CDMA, WCDMA, and LTE operating.
 Supports multi operator configurations and up to 3 sub bands per band.
 Operation via WEB based OMT software.
 Friendly and easy OMT interface via RJ45 connection.
 Support Ethernet for remote monitoring and control.

Product Description
mBDA is a wireless enhanced solution where high-quality voice or high-speed data service is not available between
a mobile and a base station. mBDA is ideal for the first phase of the network rollout and for any subsequent phase
where cost, coverage, and quality need to be optimized.

mBDA offers a modular, robust design that is easy to install, manage and upgrade. It supports three individually
adjustable sub-bands for flexibility and high RF performance, supports multi-carrier and multi-band operation.

Remote configuration and surveillance is possible through Comba’s remote control and monitoring system via PC to
the OMT/OMC.

Support Technologies
Frequency Range (MHz)
Band Technologies Downlink (DL) Uplink (UL)
700MHz UpperC LTE 746-757 776-787
700MHz LowerABC LTE 728-746 698-716
850MHz GSM/CDMA/WCDMA/LTE 869-894 824-849
1900MHz GSMCDMA/WCDMA/LTE 1930-1995 1850-1915
AWS WCDMA/LTE 2110-2155 1710-1755
2600MHz LTE 2620-2690 2500-2570

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 126 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-4 / 0215
RF Parameters
LTE 700MHz UpperC GSM/CDMA/WCDMA/LTE 850 MHz
RF Parameter DL UL RF Parameter DL UL
Frequency Range (MHz) 746-757 776-787 Frequency Range (MHz) 869-894 824-849
Max Output Power Per Antenna Port Max Output Power Per Antenna Port
1(Composite) 27, 30, 33 17 1(Composite) 27, 30, 33 23
2 Carriers -3 / 2 Carriers -3 /
4 Carriers -6 / 4 Carriers -6 /
8 Carriers -9 / 8 Carriers -9 /
Sub-bands 1 1 Sub-bands 3 3
Operating Bandwidth (MHz) 5-11 5-11 Operating Bandwidth (MHz) 0.2-24.8 0.2-24.8
Maximum System Gain (dB) 80 80 Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4 Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) / 5 System Noise Figure (dB) / 5
System Group Delay (sec) 6 6 System Group Delay (sec) 6 6
Gain Adjustable Range 0-30 0-30 Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP Emission Mask 3GPP 3GPP
1 1
Intermodulation 3GPP 3GPP Intermodulation 3GPP 3GPP

LTE 700MHz LowerABC GSM/CDMA/WCDMA/LTE 1900 MHz


RF Parameter DL UL RF Parameter DL UL
Frequency Range (MHz) 728-746 698-716 Frequency Range (MHz) 1930-1995 1850-1915
Max Output Power Per Antenna Port Max Output Power Per Antenna Port
1(Composite) 27, 30, 33 17 1(Composite) 27, 30, 33 23
2 Carriers -3 / 2 Carriers -3 /
4 Carriers -6 / 4 Carriers -6 /
8 Carriers -9 / 8 Carriers -9 /
Sub-bands 3 3 Sub-bands 3 3
Operating Bandwidth (MHz) 5-18 5-18 Operating Bandwidth (MHz) 0.2-25 0.2-25
Maximum System Gain (dB) 80 80 Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4 Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) / 5 System Noise Figure (dB) / 5
System Group Delay (sec) 6 6 System Group Delay (sec) 6 6
Gain Adjustable Range 0-30 0-30 Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP Emission Mask 3GPP 3GPP
2 1
Intermodulation 3GPP 3GPP Intermodulation 3GPP 3GPP

Note:
Operating Bandwidth: GSM/CDMA Max. Bandwidth 25MHz, WCDMA Max. Bandwidth 15MHz, LTE Max. Bandwidth 20MHz.
*WCDMA is based on 3GPP TS 25.106 V9.0.0 (2009-12).
**LTE service is based on 3GPP TS 36.106 V9.0.0 (2009-12)
1
Intermodulation: WCDMA @ 3GPP; GSM/CDMA @ Less than-13dBm.
2
Intermodulation: LTE @ 3GPP; GSM @ Less than-13dBm.
RF specification is without Combiner Unit, Comber Unit insert loss is less than 1.0dB.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 127 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-4 / 0215
RF Parameter (continued)
WCDMA/LTE AWS LTE 2600 MHz
RF Parameter DL UL RF Parameter DL UL
Frequency Range (MHz) 2110-2155 1710-1755 Frequency Range (MHz) 2620-2690 2500-2570
Max Output Power Per Antenna Port Max Output Power Per Antenna Port
1(Composite) 27, 30, 33 17 1(Composite) 27, 30, 33 17
2 Carriers -3 / 2 Carriers -3 /
4 Carriers -6 / 4 Carriers -6 /
8 Carriers -9 / 8 Carriers -9 /
Sub-bands 3 3 Sub-bands 3 3
Operating Bandwidth (MHz) 5-20 5-20 Operating Bandwidth (MHz) 5-20 5-20
Maximum System Gain (dB) 80 80 Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4 Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) / 5 System Noise Figure (dB) / 5
System Group Delay (sec) 6 6 System Group Delay (sec) 6 6
Gain Adjustable Range 0-30 0-30 Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP Emission Mask 3GPP 3GPP
Intermodulation 3GPP 3GPP Intermodulation 3GPP 3GPP

Note:
Operating Bandwidth: GSM/CDMA Max. Bandwidth 25MHz, WCDMA Max. Bandwidth 15MHz, LTE Max. Bandwidth 20MHz.
RF specification is without Combiner Unit, Comber Unit insert loss is less than 1.0dB.

Mechanical Specifications
System Rack (4 bands) 267 x 482 x 485, (10.5 x 19 x 19.1)
Power Unit 220 x 80 x 440, (8.7 x 3.1 x 17.3)
Dimensions, H x W x D, mm (in)
Combiner Unit 220 x 60 x 230, (8.7 x 2.4 x 9.1)
RF Unit 220 x 60 x 350, (8.7 x 2.4 x 13.8)
System Rack (4 bands) 13.2, (29.1)
Power and Monitor Unit 4, (8.8)
Weight, kg (lb) (approx.)
Combiner Unit 4, (8.8)
RF Card 3.8, (8.4)
Power and Monitor Unit 15
Power Consumption, W (approx.)
RF Unit 50
Power Supply 100-240VAC/47-63Hz
Power Up Waiting Time (sec) (approx.) 180
Enclosure Cooling Convection or Fan
RF Connectors N-Female/MINI-DIN
Operating Temperature (°C ) -20 to +40
Operating Humidity 10% to 85%
Environmental Class IP30
MTBF ( hr) ≥ 50,000
Mounting 19” Rack

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 128 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-4 / 0215
Appendix I: Combiner Specifications
Electrical Band1 Band2 Band3 Band4
Operating Frequency (MHz) 698-788 824-894 1850-1995 1710-1755/2110-2155
Insert Loss (dB) ≤ 0.7 ≤ 0.7 ≤ 0.8 ≤1
VSWR ≤ 1.6 ≤ 1.6 ≤ 1.6 ≤ 1.6
Mechanical
Dimensions, H x W x D, mm (in) 226.5 x 58.6 x 251, (8.9 x 2.4 x 9.9)
Weight (approx.), kg (lb) 4, (8.8)
RF Connectors Mini-DIN Female
Operating Temperature , C (F) -20 to +40 (68 to 104)
Operating Humidity  85%
Environmental Class IP30
Note: Typical specification at room temperature;

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 129 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-4 / 0215
mBDA Indoor Digital Band Selective Repeater
mBDA-300
Features
 Max. 4 bands of 700(APT) 850/1800 (or 1900)/2100 (or AWS)/2600MHz.
 Supports GSM, CDMA, WCDMA, and LTE operating.
 Supports multi operator configurations and up to 3 sub bands per band.
 Operation via OMT software.
 Friendly and easy OMT interface via RJ45 connection.
 Integrated wireless modem or Ethernet for remote monitoring and control.

Product Description
mBDA is a wireless enhanced solution where high-quality voice or high-speed data service is not available between
a mobile and a base station. mBDA is ideal for the first phase of the network rollout and for any subsequent phase
where cost, coverage, and quality need to be optimized.

mBDA offers a modular, robust design that is easy to install, manage and upgrade. It supports three individually
adjustable sub-bands for flexibility and high RF performance, supports multi-carrier and multi-band operation.

Remote configuration and surveillance is possible through Comba’s remote control and monitoring system via PC or
wireless modem to the OMT/OMC.

Support Technologies
Frequency Range (MHz)
Band Technologies Downlink (DL) Uplink (UL)
700MHz* LTE 758-788/773-803 703-733/718-748
850MHz GSM/CDMA/WCDMA** 869-894 824-849
1800MHz GSM/LTE 1805-1880 1710-1785
1900MHz GSMCDMA/WCDMA** 1930-1995 1850-1915
AWS WCDMA/LTE 2110-2155 1710-1755
2100MHz WCDMA/LTE** 2110-2170 1920-1980
2600MHz LTE 2620-2690 2500-2570

*700MHz is APT band, 2 options as 703-733/758-788 and 718-748/773-803.


**WCDMA complies with 3GPP TS 25.106 V9.0.0 (2009-12) table 9.2, 9.3, 9.4 spectrum emission mask.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 130 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-3 / 0615
RF Parameters
LTE 700A GSM/CDMA/WCDMA 850 MHz
RF Parameter DL UL RF Parameter DL UL
Frequency Range (MHz) 758-788 703-733 Frequency Range (MHz) 869-894 824-849
Max Output Power Per Antenna Port Max Output Power Per Antenna Port
1(Composite) 27, 30, 33 17 1(Composite) 27, 30, 33 23
2 Carriers -3 / 2 Carriers -3 /
4 Carriers -6 / 4 Carriers -6 /
8 Carriers -9 / 8 Carriers -9 /
Sub-bands 3 3 Sub-bands 3 3
Operating Bandwidth (MHz) 3-20 3-20 Operating Bandwidth (MHz) 0.2-24.8 0.2-24.8
Maximum System Gain (dB) 80 80 Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4 Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) / 5 System Noise Figure (dB) / 5
System Group Delay (sec) 6 6 System Group Delay (sec) 6 6
Gain Adjustable Range 0-30 0-30 Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP Emission Mask 3GPP 3GPP
1
Intermodulation 3GPP 3GPP Intermodulation 3GPP 3GPP

LTE 700B GSM/LTE 1800 MHz


RF Parameter DL UL RF Parameter DL UL
Frequency Range (MHz) 773-803 718-748 Frequency Range (MHz) 1805-1880 1710-1785
Max Output Power Per Antenna Port Max Output Power Per Antenna Port
1(Composite) 27, 30, 33 17 1(Composite) 27, 30, 33 23
2 Carriers -3 / 2 Carriers -3 /
4 Carriers -6 / 4 Carriers -6 /
8 Carriers -9 / 8 Carriers -9 /
Sub-bands 3 3 Sub-bands 3 3
Operating Bandwidth (MHz) 3-20 0.2-24.8 Operating Bandwidth (MHz) 0.2-25 0.2-25
Maximum System Gain (dB) 80 80 Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4 Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) / 5 System Noise Figure (dB) / 5
System Group Delay (sec) 6 6 System Group Delay (sec) 6 6
Gain Adjustable Range 0-30 0-30 Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP Emission Mask 3GPP 3GPP
2
Intermodulation 3GPP 3GPP Intermodulation 3GPP 3GPP

Note:
Operating Bandwidth: GSM/CDMA Max. Bandwidth 25MHz; WCDMA Max. Bandwidth 15MHz; LTE Max. Bandwidth 20MHz.
1
Intermodulation: WCDMA @ 3GPP; GSM/CDMA @ Less than-13dBm.
2
Intermodulation: LTE @ 3GPP; GSM @ Less than-13dBm.
RF specification is without Combiner Unit, Comber Unit insert loss is less than 1.5dB.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 131 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-3 / 0615
RF Parameters (continued)
GSM/CDMA/WCDMA 1900 MHz WCDMA/LTE AWS
RF Parameter DL UL RF Parameter DL UL
Frequency Range (MHz) 1930-1995 1850-1915 Frequency Range (MHz) 2110-2155 1710-1755
Max Output Power Per Antenna Port Max Output Power Per Antenna Port
1(Composite) 27, 30, 33 23 1(Composite) 27, 30, 33 17
2 Carriers -3 / 2 Carriers -3 /
4 Carriers -6 / 4 Carriers -6 /
8 Carriers -9 / 8 Carriers -9 /
Sub-bands 3 3 Sub-bands 3 3
Operating Bandwidth (MHz) 0.2-25 0.2-25 Operating Bandwidth (MHz) 3-20 3-20
Maximum System Gain (dB) 80 80 Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4 Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) / 5 System Noise Figure (dB) / 5
System Group Delay (sec) 6 6 System Group Delay (sec) 6 6
Gain Adjustable Range 0-30 0-30 Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP Emission Mask 3GPP 3GPP
1
Intermodulation 3GPP 3GPP Intermodulation 3GPP 3GPP

WCDMA/LTE 2100 MHz LTE 2600 MHz


RF Parameter DL UL RF Parameter DL UL
Frequency Range (MHz) 2110-2170 1920-1980 Frequency Range (MHz) 2620-2690 2500-2570
Max Output Power Per Antenna Port Max Output Power Per Antenna Port
1(Composite) 27, 30, 33 17 1(Composite) 27, 30, 33 17
2 Carriers -3 / 2 Carriers -3 /
4 Carriers -6 / 4 Carriers -6 /
8 Carriers -9 / 8 Carriers -9 /
Sub-bands 3 3 Sub-bands 3 3
Operating Bandwidth (MHz) 3-20 3-20 Operating Bandwidth (MHz) 3-20 3-20
Maximum System Gain (dB) 80 80 Maximum System Gain (dB) 80 80
Pass Band Ripple at FBW, p-p (dB) 4 4 Pass Band Ripple at FBW, p-p (dB) 4 4
System Noise Figure (dB) / 5 System Noise Figure (dB) / 5
System Group Delay (sec) 6 6 System Group Delay (sec) 6 6
Gain Adjustable Range 0-30 0-30 Gain Adjustable Range 0-30 0-30
Emission Mask 3GPP 3GPP Emission Mask 3GPP 3GPP
Intermodulation 3GPP 3GPP Intermodulation 3GPP 3GPP

Note:
Operating Bandwidth: GSM/CDMA Max. Bandwidth 25MHz, WCDMA Max. Bandwidth 15MHz, LTE Max. Bandwidth 20MHz.
1
Intermodulation: WCDMA @ 3GPP; GSM/CDMA @ Less than-13dBm
RF specification is without Combiner Unit, Comber Unit insert loss is less than 1.5dB.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 132 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-3 / 0615
Mechanical Specifications
System Rack (4 bands) 267 x 482 x 485, (10.5 x 19 x 19.1)
Power Unit 220 x 80 x 440, (8.7 x 3.1 x 17.3)
Dimensions, H x W x D, mm (in)
Combiner Unit 220 x 60 x 230, (8.7 x 2.4 x 9.1)
RF Unit 220 x 60 x 350, (8.7 x 2.4 x 13.8)
System Rack (4 bands) 13.2, (29.1)
Power and Monitor Unit 4, (8.8)
Weight, kg (lb) (approx.)
Combiner Unit 4, (8.8)
RF Card 3.8, (8.4)
Power and Monitor Unit 15
Power Consumption, W (approx.)
RF Unit 50
Power Supply 100-240VAC/47-63Hz
Power Up Waiting Time (sec) (approx.) 180
Enclosure Cooling Convection or Fan
RF Connectors N Female
Operating Temperature (°C ) -20 to +40
Operating Humidity 10% to 85%
Environmental Class IP30
MTBF ( hr) ≥ 50,000
Mounting 19” Rack

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 133 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-3 / 0615
Band Adjustable Pico Repeater
Features
 15dBm or 17dBm Downlink output power.
 Fixed bandwidth (customized) and operating band adjustable.
 Broadband linear power amplifier ensures undistorted amplification of signals.
 Low noise amplifier improves uplink system noise figure for better voice quality
and reduces drop call.
 Local commissioning by OMT software and remote monitoring available by Modem (optional).

Product Description
 Fast deployment for small to medium sized Indoor Coverage.
 Residential apartments.
 Shops, Restaurants, Supermarkets.
 Offices, underground car parks and other commercial areas.

Functional Block Diagram

Mobile Ant

LNA1 PA1
Band selective
Donor Ant module

Duplexer Duplexer
PA2 LNA2 MT
DT Band selective
module

Mobile

Main Control Unit


BTS Modem

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 134 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-3 / 0615
900MHz Band Adjustable Pico Repeater
SP-9110
Specifications
Electrical 15dBm
Frequency Range, Uplink MHz 890-915
Frequency Range, Downlink MHz 935-960
Operating Bandwidth MHz 5, 10, 15 (Customized)
Output Power, Downlink dBm 15
Output Power, Uplink dBm 15
Maximum System Gain dB 65
Gain Adjustment Range (1dB step) dB 0-20
Pass Band Ripple, p-p dB ≤5
System Noise Figure at Maximum Gain, Uplink dB ≤7
System Group Delay sec ≤5
400kHz offset and greater dB ≤ 50
600kHz offset and greater dB ≤ 40
Out of band gain
1MHz offset and greater dB ≤ 35
5MHz offset and greater dB ≤ 25
Spurious emission and 9kHz~1GHz dBm ≤ -30
Intermodulation 1GHz~12.75GHz dBm ≤ -30
Downlink Input VSWR ≤ 1.8
Absolute Maximum RF Input Power dBm -10
Impedance  50
Mechanical
Dimensions, H x W x D mm 210 x 140 x 39.5
Weight (approx.) kg 1.2
Input VAC 100-240/47-63Hz
External Power Supply Unit
Output VDC 12
Power Consumption (approx.) W 20
Enclosure Cooling Convection
RF Connectors SMA
Operating Temperature °C -10 to +40
Operating Humidity ≤ 85%
Environmental Class IP30
MTBF hr > 50,000
Note: Typical specification at room temperature.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 135 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-2 / 1115
2100MHz Band Adjustable Pico Repeater
SP-2110
Specifications
Electrical 17dBm
Frequency Range, Uplink MHz 1920-1980
Frequency Range, Downlink MHz 2110-2170
Operating Bandwidth MHz 5, 10, 15 (Customized)
Output Power, Downlink dBm 17
Output Power, Uplink dBm 17
Maximum System Gain dB 65
ALC Range dB 20
Gain Adjustment Range (1dB step) dB 0-20
Pass Band Ripple, p-p dB ≤ 2@3.84MHz
System Noise Figure at Maximum Gain, Uplink dB ≤6
System Group Delay sec ≤4
Spurious dBm
Intermodulation dBm
3GPP TS 25.106 and 3GPP TS 25.143
Spectrum Emission Mask
EVM
Downlink Input VSWR ≤ 1.6
Absolute Maximum RF Input Power dBm -10
Impedance  50
Mechanical
Dimensions, H x W x D mm 210 x 140 x 39.5
Weight (approx.) kg 1.2
Input VAC 100-240/47-63Hz
External Power Supply Unit
Output VDC 6
Power Consumption (approx.) W 20
Enclosure Cooling Convection
RF Connectors SMA
Operating Temperature °C -10 to +40
Operating Humidity ≤ 85%
Environmental Class IP30
MTBF hr > 50,000
Note: Typical specification at room temperature.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 136 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 3-1-1 / 1115
MP Series Digital Pico Repeater
Features
 Bandwidth adjustable for both downlink and uplink.
 Max. 2 pass band segments with independent ON/OFF for maximum flexibility.
 Max. 20dBm total output power.
 Offline isolation detection for easy commissioning.
 Low noise amplifier improves system noise figure for better voice quality and reduced drop call.
 Highly integrated design with miniaturized enclosure, small size, light weight and easy to install.
 Includes Modem for remote monitoring (option).
 Compatible to Comba generic OMT and CMS platform.

Block Diagram

LNA1 PA1

Mobile
Donor Ant
Ant Integrated Frequency
DT selective module MT

Mobile

BTS PA2 LNA2

Alarm Power
Indicator Main Control Unit Supply
Wireless Modem
Modem

OMC
External
OMT Power

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 137 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-1-1 / 0217
800MHz Digital Pico Repeater
MP-0832
Specifications
Electrical 17dBm 20dBm
Operating Frequency, Uplink MHz 832-862
Operation Frequency, Downlink MHz 791-821
Instantaneous Bandwidth MHz 30
Operating Bandwidth Per Sub-band MHz 3-20
Number of Sub-bands 2
Total Output Power, Uplink dBm 17 17
Total Output Power, Downlink dBm 17 20
Maximum System Gain dB 75
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB ≤4
Uplink Noise Figure dB 7
System Group Delay sec ≤6
Spurious Emission Mask
Intermodulation Compliance with 3GPP TS 36.106
EVM
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.0
Impedance  50
Mechanical
Dimensions, W x H x D mm 198 x 78 x 43
Weight (approx.) kg 0.5
Input VAC 100-240/50-60Hz
External Power Supply Unit
Output VDC 12
Power Consumption W 14
Enclosure Cooling Convection
Connectors SMA-Female
Operating Temperature °C -10 to +40
Operating Humidity  85%
Environmental Class IP30
MTBF hr  50,000
Remote Monitoring (option) Built in WCDMA Modem
Note: Typical specification at room temperature

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 138 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-1-1 / 0217
850MHz Digital Pico Repeater
MP-8132
Specifications
Electrical 17dBm 20dBm
Operating Frequency, Uplink MHz 824-849
Operation Frequency, Downlink MHz 869-894
Instantaneous Bandwidth MHz 25
Operating Bandwidth Per Sub-band* MHz 0.2-24.8
Number of Sub-bands 2
Total Output Power, Uplink dBm 17 17
Total Output Power, Downlink dBm 17 20
Maximum System Gain dB 75
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB ≤5
Uplink Noise Figure dB 7
System Group Delay sec ≤6
Spurious Emission Mask
Compliance with 3GPP TS 25.106
Intermodulation
Compliance with 3GPP TS 36.106
EVM
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.0
Impedance  50
Mechanical
Dimensions, W x H x D mm 198 x 78 x 43
Weight (approx.) kg 0.5
Input VAC 100-240/50-60Hz
External Power Supply Unit
Output VDC 12
Power Consumption W 14
Enclosure Cooling Convection
Connectors SMA-Female
Operating Temperature °C -10 to +40
Operating Humidity  85%
Environmental Class IP30
MTBF hr  50,000
Remote Monitoring (option) Built in WCDMA Modem
Note: Typical specification at room temperature
*: GSM Max. Bandwidth 24.8MHz, WCDMA, LTE Max. Bandwidth 20MHz

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 139 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-1-1 / 0217
900MHz Digital Pico Repeater
MP-9132
Specifications
Electrical 17dBm 20dBm
Operating Frequency, Uplink MHz 880-915
Operation Frequency, Downlink MHz 925-960
Instantaneous Bandwidth MHz 35
Operating Bandwidth Per Sub-band* MHz 0.2-25
Number of Sub-bands 2
Total Output Power, Uplink dBm 17 17
Total Output Power, Downlink dBm 17 20
Maximum System Gain dB 75
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB ≤4
Uplink Noise Figure dB 7
System Group Delay sec ≤6
Spurious Emission Mask
Compliance with 3GPP TS 25.106
Intermodulation
Compliance with 3GPP TS 36.106
EVM
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.0
Impedance  50
Mechanical
Dimensions, W x H x D mm 198 x 78 x 43
Weight (approx.) kg 0.5
Input VAC 100-240/50-60Hz
External Power Supply Unit
Output VDC 12
Power Consumption W 14
Enclosure Cooling Convection
Connectors SMA-Female
Operating Temperature °C -10 to +40
Operating Humidity  85%
Environmental Class IP30
MTBF hr  50,000
Remote Monitoring (option) Built in WCDMA Modem
Note: Typical specification at room temperature;
*: GSM Max. Bandwidth 25MHz, WCDMA, LTE Max. Bandwidth 20MHz.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 140 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-1-1 / 0217
1800MHz Digital Pico Repeater
MP-1832
Specifications
Electrical 17dBm 20dBm
Operating Frequency, Uplink MHz 1710-1785
Operation Frequency, Downlink MHz 1805-1880
Instantaneous Bandwidth MHz 50
Operating Bandwidth Per Sub-band* MHz 0.2-25
Number of Sub-bands 2
Total Output Power, Uplink dBm 17 17
Total Output Power, Downlink dBm 17 20
Maximum System Gain dB 75
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB ≤4
System Group Delay sec ≤6
Spurious Emission Mask
Intermodulation Compliance with 3GPP TS 36.106
EVM
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.0
Impedance  50
Mechanical
Dimensions, W x H x D mm 198 x 78 x 43
Weight (approx.) kg 0.5
Input VAC 100-240/50-60Hz
External Power Supply Unit
Output VDC 12
Power Consumption W 14
Enclosure Cooling Convection
Connectors SMA-Female
Operating Temperature °C -10 to +40
Operating Humidity  85%
Environmental Class IP30
MTBF hr  50,000
Remote Monitoring (option) Built in WCDMA Modem
Note: Typical specification at room temperature
*: GSM Max. Bandwidth 25MHz, LTE Max. Bandwidth 20MHz

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 141 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-1-1 / 0217
1900MHz Digital Pico Repeater
MP-1932
Specifications
Electrical 17dBm 20dBm
Operating Frequency, Uplink MHz 1850-1910
Operation Frequency, Downlink MHz 1930-1990
Operating Bandwidth Per Sub-band MHz 0.2-25
Number of Sub-bands 2
Total Output Power, Uplink dBm 17 17
Total Output Power, Downlink dBm 17 20
Maximum System Gain dB 75
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB ≤5
System Group Delay sec ≤6
Spurious Emission Mask
Compliance with 3GPP TS 25.106
Intermodulation
EVM
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.0
Impedance  50
Mechanical
Dimensions, W x H x D mm 198 x 78 x 43
Weight (approx.) kg 0.5
Input VAC 100-240/50-60Hz
External Power Supply Unit
Output VDC 12
Power Consumption W 14
Enclosure Cooling Convection
Connectors SMA-Female
Operating Temperature °C -10 to +40
Operating Humidity  85%
Environmental Class IP30
MTBF hr  50,000
Remote Monitoring (option) Built in WCDMA Modem
Note: Typical specification at room temperature
*: GSM Max. Bandwidth 25MHz; WCDMA, LTE Max. Bandwidth 20MHz

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 142 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-1-1 / 0217
2100MHz Digital Pico Repeater
MP-2132
Specifications
Electrical 17dBm 20dBm
Operating Frequency, Uplink MHz 1920-1980
Operation Frequency, Downlink MHz 2110-2170
Instantaneous Bandwidth MHz 50
Operating Bandwidth Per Sub-band MHz 3-20
Number of Sub-bands 2
Total Output Power, Uplink dBm 17 17
Total Output Power, Downlink dBm 17 20
Maximum System Gain dB 75
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB ≤4
System Group Delay sec ≤6
Spurious Emission Mask
Compliance with 3GPP TS 25.106
Intermodulation
Compliance with 3GPP TS 36.106
EVM
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.0
Impedance  50
Mechanical
Dimensions, W x H x D mm 198 x 78 x 43
Weight (approx.) kg 0.5
Input VAC 100-240/50-60Hz
External Power Supply Unit
Output VDC 12
Power Consumption W 14
Enclosure Cooling Convection
Connectors SMA-Female
Operating Temperature °C -10 to +40
Operating Humidity  85%
Environmental Class IP30
MTBF hr  50,000
Remote Monitoring (option) Built in WCDMA Modem
Note: Typical specification at room temperature

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 143 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-1-1 / 0217
2600MHz Digital Pico Repeater
MP-2632
Specifications
Electrical 17dBm 20dBm
Operating Frequency, Uplink MHz 2500-2570
Operation Frequency, Downlink MHz 2620-2690
Instantaneous Bandwidth MHz 50
Operating Bandwidth Per Sub-band MHz 3-20
Number of Sub-bands 2
Total Output Power, Uplink dBm 17 17
Total Output Power, Downlink dBm 17 20
Maximum System Gain dB 75
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB ≤5
System Group Delay sec ≤6
Spurious Emission Mask
Compliance with 3GPP TS 36.106
Intermodulation
EVM
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.0
Impedance  50
Mechanical
Dimensions, W x H x D mm 198 x 78 x 43
Weight (approx.) kg 0.5
Input VAC 100-240/50-60Hz
External Power Supply Unit
Output VDC 12
Power Consumption W 14
Enclosure Cooling Convection
Connectors SMA-Female
Operating Temperature °C -10 to +40
Operating Humidity  85%
Environmental Class IP30
MTBF hr  50,000
Remote Monitoring (option) Built in WCDMA Modem
Note: Typical specification at room temperature

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 144 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-1-1 / 0217
Multi-band Digital Pico Repeater
Features
 2 or 3 bands configuration in one system
 Bandwidth adjustable for both downlink and uplink.
 Max. 2 pass band segments with independent ON/OFF for maximum flexibility.
 17 or 20dBm total output power.
 Offline isolation detection for easy commissioning.
 Low noise amplifier improves system noise figure for better voice quality and reduced drop call.
 Highly integrated design with miniaturized enclosure, small size, light weight and easy to install.
 Includes Modem for remote monitoring (option).
 Compatible to Comba generic OMT and CMS platform.

Functional Block Diagram

LNA PA
Band selective
module
Duplexer
Duplexer
PA LNA
Band selective LTE MT
LTE DT module

LNA PA
Band selective
WCDMA DT
module WCDMA MT
Duplexer
Duplexer
PA LNA
Band selective
module

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 145 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-1-1 / 0217
Dual-band Digital Pico Repeater
MP-7V32
Specifications-17dBm
Electrical 800MHz 2100MHz
Operating Frequency, Uplink MHz 832-862 1920-1980
Operation Frequency, Downlink MHz 791-821 2110-2170
Instantaneous Bandwidth MHz 30 50
Operating Bandwidth Per Sub-band MHz 3-20 3-20
Number of Sub-bands 2
Total Output Power, Uplink dBm 14 14
Total Output Power, Downlink dBm 17 17
Maximum System Gain dB 75
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB 4 4
System Group Delay sec ≤6
Spurious Emission Mask
Compliance with
Compliance with
Intermodulation 3GPP TS 25.106
3GPP TS 36.106
3GPP TS 36.106
EVM
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.0
Impedance  50
Mechanical
Dimensions, W x H x D mm 316 x 224 x 55
Weight (approx.) kg 3
Input VAC 100-240/50-60Hz
External Power Supply Unit
Output VDC 12
Power Consumption W 26
Enclosure Cooling Convection
Connectors SMA-Female
Operating Temperature °C -10 to +40
Operating Humidity  85%
Environmental Class IP30
MTBF hr  50,000
Remote Monitoring (option) Built in WCDMA Modem
Note: Typical specification at room temperature;
.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 146 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-1-1 / 0217
Specifications-20dBm
Electrical 800MHz 2100MHz
Operating Frequency, Uplink MHz 832-862 1920-1980
Operation Frequency, Downlink MHz 791-821 2110-2170
Instantaneous Bandwidth MHz 30 50
Operating Bandwidth Per Sub-band MHz 3-20 3-20
Number of Sub-bands 2
Total Output Power, Uplink dBm 17 17
Total Output Power, Downlink dBm 20 20
Maximum System Gain dB 75
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB 4 4
System Group Delay sec ≤6
Spurious Emission Mask
Compliance with
Compliance with
Intermodulation 3GPP TS 25.106
3GPP TS 36.106
3GPP TS 36.106
EVM
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.0
Impedance  50
Mechanical
Dimensions, W x H x D mm 316 x 224 x 55
Weight (approx.) kg 3
Input VAC 100-240/50-60Hz
External Power Supply Unit
Output VDC 12
Power Consumption W 30
Enclosure Cooling Convection
Connectors SMA-Female
Operating Temperature °C -10 to +40
Operating Humidity  85%
Environmental Class IP30
MTBF hr  50,000
Remote Monitoring (option) Built in WCDMA Modem
Note: Typical specification at room temperature;
.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 147 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-1-1 / 0217
Dual-band Digital Pico Repeater
MP-7532
Specifications-17dBm
Electrical 900MHz 1800MHz
Operating Frequency, Uplink MHz 880-915 1710-1785
Operation Frequency, Downlink MHz 925-960 1805-1880
Instantaneous Bandwidth MHz 35 50
Operating Bandwidth Per Sub-band* MHz 0.2-25 0.2-25
Number of Sub-bands 2
Total Output Power, Uplink dBm 14 14
Total Output Power, Downlink dBm 17 17
Maximum System Gain dB 75
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB ≤4 4
System Group Delay sec ≤6
Spurious Emission Mask
Compliance with
Compliance with
Intermodulation 3GPP TS 25.106 and 3GPP
3GPP TS 36.106
TS 36.106
EVM
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.0
Impedance  50
Mechanical
Dimensions, W x H x D mm 316 x 224 x 55
Weight (approx.) kg 3
Input VAC 100-240/50-60Hz
External Power Supply Unit
Output VDC 12
Power Consumption W 26
Enclosure Cooling Convection
Connectors SMA-Female
Operating Temperature °C -10 to +40
Operating Humidity  85%
Environmental Class IP30
MTBF hr  50,000
Remote Monitoring (option) Built in WCDMA Modem
Note: Typical specification at room temperature;
*: GSM Max. Bandwidth 25MHz, WCDMA, LTE Max. Bandwidth 20MHz.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 148 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-1-1 / 0217
Specifications-20dBm
Electrical 900MHz 1800MHz
Operating Frequency, Uplink MHz 880-915 1710-1785
Operation Frequency, Downlink MHz 925-960 1805-1880
Instantaneous Bandwidth MHz 35 50
Operating Bandwidth Per Sub-band* MHz 0.2-25 0.2-25
Number of Sub-bands 2
Total Output Power, Uplink dBm 17 17
Total Output Power, Downlink dBm 20 20
Maximum System Gain dB 75
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB ≤4 4
System Group Delay sec ≤6
Spurious Emission Mask
Compliance with
Compliance with
Intermodulation 3GPP TS 25.106
3GPP TS 36.106
3GPP TS 36.106
EVM
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.0
Impedance  50
Mechanical
Dimensions, W x H x D mm 316 x 224 x 55
Weight (approx.) kg 3
Input VAC 100-240/50-60Hz
External Power Supply Unit
Output VDC 12
Power Consumption W 30
Enclosure Cooling Convection
Connectors SMA-Female
Operating Temperature °C -10 to +40
Operating Humidity  85%
Environmental Class IP30
MTBF hr  50,000
Remote Monitoring (option) Built in WCDMA Modem
Note: Typical specification at room temperature;
*: GSM Max. Bandwidth 25MHz, WCDMA, LTE Max. Bandwidth 20MHz.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 149 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-1-1 / 0217
Dual-band Digital Pico Repeater
MP-7632
Specifications-17dBm
Electrical 900MHz 2100MHz
Operating Frequency, Uplink MHz 880-915 1920-1980
Operation Frequency, Downlink MHz 925-960 2110-2170
Instantaneous Bandwidth MHz 35 50
Operating Bandwidth Per Sub-band* MHz 0.2-25 3-20
Number of Sub-bands 2
Total Output Power, Uplink dBm 14 14
Total Output Power, Downlink dBm 17 17
Maximum System Gain dB 75
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB 4 4
System Group Delay sec ≤6
Spurious Emission Mask
Compliance with
Compliance with
Intermodulation 3GPP TS 25.106
3GPP TS 25.106
3GPP TS 36.106
EVM
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.0
Impedance  50
Mechanical
Dimensions, W x H x D mm 316 x 224 x 5
Weight (approx.) kg 3
Input VAC 100-240/50-60Hz
External Power Supply Unit
Output VDC 12
Power Consumption W 30
Enclosure Cooling Convection
Connectors SMA-Female
Operating Temperature °C -10 to +40
Operating Humidity  85%
Environmental Class IP30
MTBF hr  50,000
Remote Monitoring (option) Built in WCDMA Modem
Note: Typical specification at room temperature;
*: GSM Max. Bandwidth 25MHz, WCDMA, LTE Max. Bandwidth 20MHz.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 150 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-1-1 / 0217
Specifications-20dBm
Electrical 900MHz 2100MHz
Operating Frequency, Uplink MHz 880-915 1920-1980
Operation Frequency, Downlink MHz 925-960 2110-2170
Instantaneous Bandwidth MHz 35 50
Operating Bandwidth Per Sub-band* MHz 0.2-25 3-20
Number of Sub-bands 2
Total Output Power, Uplink dBm 17 17
Total Output Power, Downlink dBm 20 20
Maximum System Gain dB 75
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB 4 4
System Group Delay sec ≤6
Spurious Emission Mask
Compliance with
Compliance with
Intermodulation 3GPP TS 25.106
3GPP TS 25.106
3GPP TS 36.106
EVM
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.0
Impedance  50
Mechanical
Dimensions, W x H x D mm 316 x 224 x 55
Weight (approx.) kg 3
Input VAC 100-240/50-60Hz
External Power Supply Unit
Output VDC 12
Power Consumption W 30
Enclosure Cooling Convection
Connectors SMA-Female
Operating Temperature °C -10 to +40
Operating Humidity  85%
Environmental Class IP30
MTBF hr  50,000
Remote Monitoring (option) Built in WCDMA Modem
Note: Typical specification at room temperature;
*: GSM Max. Bandwidth 25MHz, WCDMA, LTE Max. Bandwidth 20MHz.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 151 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-1-1 / 0217
Dual-band Digital Pico Repeater
MP-7832
Specifications-17dBm
Electrical 1800MHz 2100MHz
Operating Frequency, Uplink MHz 1710-1785 1920-1980
Operation Frequency, Downlink MHz 1805-1880 2110-2170
Instantaneous Bandwidth MHz 50 50
Operating Bandwidth Per Sub-band* MHz 0.2-25 3-20
Number of Sub-bands 2
Total Output Power, Uplink dBm 14 14
Total Output Power, Downlink dBm 17 17
Maximum System Gain dB 70
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB 4 4
System Group Delay sec ≤6
Spurious Emission Mask
Compliance with
Compliance with
Intermodulation 3GPP TS 25.106
3GPP TS 36.106
3GPP TS 36.106
EVM
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.8
Impedance  50
Mechanical
Dimensions, W x H x D mm 316 x 224 x 55
Weight (approx.) kg 3
Input VAC 100-240/50-60Hz
External Power Supply Unit
Output VDC 12
Power Consumption W 30
Enclosure Cooling Convection
Connectors SMA-Female
Operating Temperature °C -10 to +40
Operating Humidity  85%
Environmental Class IP30
MTBF hr  50,000
Remote Monitoring (option) Built in WCDMA Modem
Note: Typical specification at room temperature;
*: GSM Max. Bandwidth 25MHz, WCDMA, LTE Max. Bandwidth 20MHz.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 152 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-1-1 / 0217
Tri-band Digital Pico Repeater
MP-5K32
Specifications
Electrical 800MHz 900MHz 2100MHz
Operating Frequency, Uplink MHz 832-862 880-915 1920-1980
Operation Frequency, Downlink MHz 791-821 925-960 2110-2170
Instantaneous Bandwidth MHz 30 35 50
Operating Bandwidth Per Sub-band* MHz 3-20 0.2-25 3-20
Number of Sub-bands 2
Total Output Power, Uplink dBm 14 14 14
Total Output Power, Downlink dBm 17 17 17
Maximum System Gain dB 70
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB 4 4 4
System Group Delay sec ≤6
Spurious Emission Mask
Compliance with Compliance with
Compliance with
Intermodulation 3GPP TS 25.106 3GPP TS 25.106
3GPP TS 36.106
3GPP TS 36.106 3GPP TS 36.106
EVM
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.8
Impedance  50
Mechanical
Dimensions, W x H x D mm 316 x 224 x 55
Weight (approx.) kg 3
Input VAC 100-240/50-60Hz
External Power Supply Unit
Output VDC 12
Power Consumption W 38
Enclosure Cooling Convection
Connectors SMA-Female
Operating Temperature °C -10 to +40
Operating Humidity  85%
Environmental Class IP30
MTBF hr  50,000
Remote Monitoring (option) Built in WCDMA Modem
Note: Typical specification at room temperature;
*: GSM Max. Bandwidth 25MHz, WCDMA, LTE Max. Bandwidth 20MHz.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 153 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-1-1 / 0217
Tri-band Digital Pico Repeater
MP-5232
Specifications-17dBm
Electrical 900MHz 1800MHz 2100MHz
Operating Frequency, Uplink MHz 880-915 1710-1785 1920-1980
Operation Frequency, Downlink MHz 925-960 1805-1880 2110-2170
Instantaneous Bandwidth MHz 35 50 50
Operating Bandwidth Per Sub-band* MHz 0.2-25 0.2-25 3-20
Number of Sub-bands 2
Total Output Power, Uplink dBm 14 14 14
Total Output Power, Downlink dBm 17 17 17
Maximum System Gain dB 70
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB 4 4 4
System Group Delay sec ≤6
Spurious Emission Mask
Compliance with Compliance with
Compliance with
Intermodulation 3GPP TS 25.106 3GPP TS 25.106
3GPP TS 36.106
3GPP TS 36.106 3GPP TS 36.106
EVM
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.8
Impedance  50
Mechanical
Dimensions, W x H x D mm 316 x 224 x 55
Weight (approx.) kg 3
Input VAC 100-240/50-60Hz
External Power Supply Unit
Output VDC 12
Power Consumption W 38
Enclosure Cooling Convection
Connectors SMA-Female
Operating Temperature °C -10 to +40
Operating Humidity  85%
Environmental Class IP30
MTBF hr  50,000
Remote Monitoring (option) Built in WCDMA Modem
Note: Typical specification at room temperature;
*: GSM Max. Bandwidth 25MHz, WCDMA, LTE Max. Bandwidth 20MHz.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 154 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-1-1 / 0217
Tri-band Digital Pico Repeater
MP-5832
Specifications
Electrical 800MHz 1800MHz 2100MHz
Operating Frequency, Uplink MHz 832-862 1710-1785 1920-1980
Operation Frequency, Downlink MHz 791-821 1805-1880 2110-2170
Operating Bandwidth Per Sub-band* MHz 3-20 0.2-25 3-20
Number of Sub-bands 2
Total Output Power, Uplink dBm 14 14 14
Total Output Power, Downlink dBm 17 17 17
Maximum System Gain dB 70
Attenuation Adjustment Range (1dB step) dB 0-30
ALC Range dB ≥ 15
Pass Band Ripple at FBW, p-p dB ≤4 4 4
System Group Delay sec ≤6
Spurious Emission Mask Compliance with
Compliance with Compliance with
Intermodulation 3GPP TS 25.106
3GPP TS 36.106 3GPP TS 36.106
3GPP TS 36.106
EVM
Absolute Maximum RF input power dBm -10
Input VSWR ≤ 2.8
Impedance  50
Mechanical
Dimensions, W x H x D mm 316 x 224 x 55
Weight (approx.) kg 3
Input VAC 100-240/50-60Hz
External Power Supply Unit
Output VDC 12
Power Consumption W 38
Enclosure Cooling Convection
Connectors SMA-Female
Operating Temperature °C -20 to +45
Operating Humidity  85%
Environmental Class IP40
MTBF hr  50,000
Remote Monitoring (option) Built in WCDMA Modem
Note: Typical specification at room temperature;
*: GSM Max. Bandwidth 25MHz, WCDMA, LTE Max. Bandwidth 20MHz.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 155 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-1-1 / 0217
LTE1800 ICS Pico Repeater
SN-1823
Features
 Support s 5/10/15/20MHz bandwidth in 20MHz pass band, independent gain control per channel.

 Plug and play.

 Built-in donor antenna and service antenna.

 Support external donor antenna and service antenna.

 System gain up to 85dB with external donor antenna.

 Uplink Noise Control functions to reduce uplink interference.

 Interference Cancellation System (ICS) to reduce the isolation requirement up to 30dB.

 Light chassis and light weight.

Specifications
Electrical 0.02W
Frequency Range, Uplink MHz 1710-1785

Frequency Range, Downlink MHz 1805-1880

Instantaneous Bandwidth MHz 20

Operating Bandwidth MHz 5/10/15/20

Total Output Power, Uplink dBm 13

Total Output Power, Downlink dBm 13

Maximum System Gain, External Donor Antenna dB 85

Maximum System Gain, Built-in Donor Antenna dB 70

Gain Control Range (0.5dB step) dB 30

AGC Control Range dB 30

Gain Flatness (Peak to peak) dB 3


Error Vector Magnitude  8%
Interference Cancellation dB  30
Out of Band Gain

Spurious Emissions
3GPP TS 36.106
Input/Output Intermodulation

Adjacent Channel Rejection Ratio

Uplink Noise Figure, Max. Gain dB 5


System Group Delay sec 6
Input VSWR  1.8

Impedance  50

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 156 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-1 / 0416
Specifications
Mechanical
Dimensions, H x W x D mm 189 x 170 x 67

Weight (approx.) kg 1.2

Power Supply VAC 100-240/50-60Hz

Power Consumption (approx.) W 10

Enclosure Cooling Convection

RF Connectors, for External Antenna SMA-F

PC Control Interface USB

Operating Temperature C -10 to +40

Operating Humidity  85%

Environmental Class IP30

LED Indicator Input RSSI, AGC Alarm, Isolation Alarm, Power On, Sleep, Output

Note: Typical specification at room temperature.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 157 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-1 / 0416
LTE2100 ICS Pico Repeater
SN-2123
Features
 Supports 5/10/15/20MHz bandwidth in 20MHz pass band, independent gain control per channel.

 Plug and play.

 Built-in donor antenna and service antenna.

 Support external donor antenna and service antenna.

 System gain up to 85dB with external donor antenna.

 Interference Cancellation System (ICS) to reduce the isolation requirement up to 30dB.

 Light chassis and light weight.

Specifications
Electrical 0.02W
Frequency Range, Uplink MHz 1920-1980

Frequency Range, Downlink MHz 2110-2170

Instantaneous Bandwidth MHz 20

Operating Bandwidth MHz 5/10/15/20

Total Output Power, Uplink dBm 13

Total Output Power, Downlink dBm 13

Maximum System Gain, External Donor Antenna dB 85

Maximum System Gain, Bulit-in Donor Antenna dB 70

Gain Control Range (0.5dB step) dB 30

AGC Control Range dB 30

Gain Flatness (Peak to peak) dB 3


Error Vector Magnitude  8%

Interference Cancellation dB 30

Out of Band Gain

Spurious Emissions
3GPP TS 36.106
Input/Output Intermodulation

Adjacent Channel Rejection Ratio

Uplink Noise Figure dB 5


System Group Delay sec 6
Input VSWR  1.8

Impedance  50

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 158 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-1 / 0416
Specifications
Mechanical
Dimensions, H x W x D mm 189 x 170 x 67

Weight (approx.) kg 1.2

Power Supply VAC 100-240/50-60Hz

Power Consumption (approx.) W 10

Enclosure Cooling Convection

RF Connectors, for External Antenna SMA-F

PC Control Interface USB

Operating Temperature C -10 to +40

Operating Humidity  85%

Environmental Class IP30

LED Indicator Input RSSI, AGC Alarm, Isolation Alarm, Power On, Sleep, Output

Note: Typical specification at room temperature.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 159 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-1 / 0416
Location System- RSSI Base Station
LB-2112
Product Description
The Comba localization system is a traceable solution designed for locating and management purposes, which
supports both indoor and outdoor. The solution includes multiple products as: base stations (TDOA type/ RSSI
type), RFID terminals (such as ID tag/ wrist strap) as well as Comba’s well-developed software platform LIMS
(Location Information Management System).

The location system is utilizing base station to transmit and receive RF signal with portable RFID devices such as
ID tag or wrist strap. All location information are stored, processed and displayed on LIMS software platform for
further management purpose against human or object.

Comba’s location base stations include TDOA (Time Difference of Arrival)


type and RSSI (Received Signal Strength Indication) type. The TDOA
type base station is designed for high accuracy while RSSI type is for
lower accuracy yet more cost effective.

The RSSI type base station is working at both 2.4 GHz and 125 kHz
frequency. The higher frequency 2.4GHz is for large area locating while
125kHz is for close distance area confirmation (e.g. through an entry).

Application Product Features


 Factory & workshop  Use 2.4GHz ISM unlicensed band
 Mine well safety & rescue  125KHz for entry confirmation
 Prison security  Max. 8x data channels
 Web GUI

Application Diagram

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 160 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-1/ 0316
Product Specifications Product Appearance
Radio Indoor Version
Radio Frequency Band 2.4GHz LAN Port 2.4G and 125K Ant
Bandwidth 80MHz

Data Rate 1Mbps

Protocol 802.15.4a
Max. Transmission Power 16dBm

Receive Sensitivity -95dBm

Coverage Distance 1-5m

Max. antenna Qty is 8x; the cable


Antenna length between Base station and
antenna less than 100m

Physical
IP54 for indoor version;
Ingress Protection
IP65 for outdoor version
2.45kg for indoor version;
Weight
3.9kg for outdoor version

Indoor version: Wall mount;


Installation Outdoor version: Wall mount/ Pole
Mount

Indoor version: Outdoor Version


Dimension 287mm x 207mm x 61.5mm
LAN PORT and 125K Ant
(LengthxWidthxHeight) Outdoor version:

287mm x 302mm x 62.2mm


o
Operating Temperature ( C) -20 to+55

Storage Temperature (oC) -25 to +60

Electrical
Power POE/220AC
Power Consumption ≤ 30W

2.4G Ant

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 161 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-1/ 0316
Location System- TDOA Base Station
LB-2115
Product Description
The Comba localization system is a traceable solution designed for locating and management purposes, which
supports both indoor and outdoor. The solution includes multiple products as: base stations (TDOA type/ RSSI type),
RFID terminals (such as ID tag/ wrist strap) as well as Comba’s well-developed software platform LIMS (Location
Information Management System).

The location system is utilizing base station to transmit and receive


RF signal with portable RFID devices such as ID tag or wrist strap.
All location information are stored, processed and displayed on
LIMS software platform for further management purpose against
human or object.

Comba’s location base stations include TDOA (Time Difference of


Arrival) type and RSSI (Received Signal Strength Indication) type.
The TDOA type base station is designed for high accuracy while
RSSI type is for lower accuracy yet more cost effective.

Application Product Features


 Factory & workshop  Use 2.4GHz ISM unlicensed band
 Mine well safety & rescue  125KHz for entry confirmation
 Prison security  Max. 8x data channels
 Web GUI

Application Diagram

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 162 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-1/ 0316
Product Specifications Product Appearance
Radio Indoor Version
Radio Frequency Band 2.4GHz LAN Port 2.4G Ant
Bandwidth 80MHz/22MHz

Data Rate 1Mbps/250Kbps

Protocol 802.15.4a
Max. Transmission Power 19dBm

Receive Sensitivity ≤ -95dBm 80MHz/1Mbps

Max. Access Terminal 200 terminal

Within 50m radius, ≤ 2m;


Locating Accuracy
Within 70m radius, ≤ 5m.

Physical
IP54 for indoor version;
Ingress Protection
IP65 for outdoor version

2.46kg for indoor version;


Weight
4.2kg for outdoor version
Indoor version: Wall mount;
Installation Outdoor version: Wall mount/ Pole
Mount

Indoor version:

Dimension 287mm x 207mm x 61.5mm


Outdoor Version
(LengthxWidthxHeight) Outdoor version:

287mm x 302mm x 62.2mm LAN PORT


o
Operating Temperature ( C) -20 to+55

Storage Temperature (oC) -25 to +60

Electrical
Power POE

Power Consumption 7W

2.4G Ant 2.4G Ant

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 163 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-1/ 0316
Location System- Software Platform
LIMS
Product Description
The Comba localization system is a traceable solution designed for locating and management purposes, which
supports both indoor and outdoor. The solution includes multiple products as: base stations (TDOA type/ RSSI type),
RFID terminals (such as ID tag/ wrist strap) as well as Comba’s well-developed software platform LIMS (Location
Information Management System).

The location system is utilizing base station to transmit and receive


RF signal with portable RFID devices such as ID tag or wrist strap.
All location information are stored, processed and displayed on
LIMS software platform for further management purpose against
human or object.

Comba’s location base stations include TDOA (Time Difference of


Arrival) type and RSSI (Received Signal Strength Indication) type.
The TDOA type base station is designed for high accuracy while
RSSI type is for lower accuracy yet more cost effective.

Application Product Features


 Complete management platform for Comba location
 Factory & workshop products as base station, locating ID card and locating
 Mine well safety & rescue wrist strap, etc.
 Prison security  Real time object or human locating.
 Real time alarm collection with Alarm history log.
 Real-time or scheduled query for parameters
configuration and status update.
 Optional Electronic Map Interface (MapX 5.0 or above
version) which can show the diagram of the whole
monitoring area, such as a mine.
 Standard windows server supported.
 Customized for TDOA algorithm locating.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 164 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-2/ 0316
Application Diagram

Specifications
Server Hardware Requirement (Minimum)
Processor Intel Xeon E7-2870

Memory 4 GByte

Hard disk 280 GByte


Network 2 x 100/1000M NICs
Serial Ports At least one available Serial Port

Server Software Requirement


Operating System Windows Server 2012 R2

Supported Database
Microsoft SQL Server 2012, version 11.0.5058.0
Applications

Installation Requirement
Remote access via team viewer is recommended for first installation and tuning, therefore public IP network shall be allowed to access during
the period.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 165 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-2/ 0316
GUI Sample

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 166 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-2/ 0316
Location System- ID Tag
LT-2102
Product Description
The Comba localization system is a traceable solution designed for locating and management purposes, which
supports both indoor and outdoor. The solution includes multiple products as: base stations (TDOA type/ RSSI type),
RFID terminals (such as ID tag/ wrist strap) as well as Comba’s well-developed software platform LIMS (Location
Information Management System).

The location system is utilizing base station to transmit and receive RF


signal with portable RFID devices such as ID tag or wrist strap. All
location information are stored, processed and displayed on LIMS
software platform for further management purpose against human or
object.

Comba’s location base stations include TDOA (Time Difference of


Arrival) type and RSSI (Received Signal Strength Indication) type. The
TDOA type base station is designed for high accuracy while RSSI type
is for lower accuracy yet more cost effective.

The ID tag is integrated with standard ISO 14443A RFID chipset, with
rechargeable battery.

Application Product Features


 Factory & workshop  Use 2.4GHz ISM unlicensed band
 Mine well safety & rescue  125KHz for entry confirmation
 Prison security  Rechargeable battery

Specifications
Radio Frequency Band 2.4 - 2.48GHz

Protocol Private
Data Rate 1M/250K bps

Max. Transmission Power 16dBm

RFID Standard ISO 14443A


Dimension 41mm x 39mm x 16mm

Weight ≤ 120g

Power Supply 3.7V chargeable Lithium battery


o
Operating Temperature ( C) -5 to+50
o
Storage Temperature ( C) -25 to+55

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 167 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-1/ 0316
Location System-Wrist Strap
LT-2103 II2
Product Description
The Comba localization system is a traceable solution designed for locating and management purposes, which
supports both indoor and outdoor. The solution includes multiple products as: base stations (TDOA type/ RSSI type),
RFID terminals (such as ID tag/ wrist strap) as well as Comba’s well-developed software platform LIMS (Location
Information Management System).

The location system is utilizing base station to transmit and receive RF


signal with portable RFID devices such as ID tag or wrist strap. All location
information are stored, processed and displayed on LIMS software
platform for further management purpose against human or object.

Comba’s location base stations include TDOA (Time Difference of Arrival)


type and RSSI (Received Signal Strength Indication) type. The TDOA type
base station is designed for high accuracy while RSSI type is for lower
accuracy yet more cost effective.

The Wrist Strap is water proof and anti-tampering, with emergency alarm,
low battery alarm and other RFID features.

Application Product Features


 Factory & workshop  Use 2.4GHz ISM unlicensed band
 Mine well safety & rescue  Anti tampering design with alarm feature
 Prison security  Emergency button
 Rechargeable battery

Specifications
Radio Frequency Band 2.4 - 2.483GHz

Protocol 802.15.4
Data Rate 1MHz

Max. Transmission Power 17 ± 3dBm

RFID Standard ISO 14443A


Dimension 41mm x 39mm x 16mm

Weight ≤ 80g

Power Supply 3.7V chargeable Lithium battery


o
Operating Temperature ( C) -5 to +50
o
Storage Temperature ( C) -25 to +55

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 168 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-1/ 0316
Appearance

Emergency Button

USB Charger

Charge Pin

Pentagon
Allen Key

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 169 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-1/ 0316
Location System-TDOA Base Station
TDJ-2400BKF-Y
Product Description
The Comba localization system is a traceable solution designed for locating and management purposes, which
supports both indoor and outdoor. The solution includes multiple products as: base stations (TDOA type/ RSSI type),
RFID terminals (such as ID tag/ wrist strap) as well as Comba’s well-developed software platform LIMS (Location
Information Management System).

The location system is utilizing base station to transmit and receive RF signal
with portable RFID devices such as ID tag or wrist strap. All location
information are stored, processed and displayed on LIMS software platform for
further management purpose against human or object.

Comba’s location base stations include TDOA (Time Difference Of Arrival) type
and RSSI (Received Signal Strength Indication) type. The TDOA type base
station is designed for high accuracy while RSSI type is for lower accuracy yet
more cost effective.

Application Product Features


 Factory & workshop  Use 2.4GHz ISM unlicensed band
 Mine well safety & rescue  125KHz for entry confirmation
 Prison security

Specifications
Radio Frequency Band 2.4 - 2.483GHz
Bandwidth 83MHz
Gain 8.5dBi
Horizontal Beamwidth 80 degree
Vertical Beamwidth 60 degree
Front-to-Rear Ratio ≥ 20dB

VSWR ≤ 1.5

Input Impedance 50Ω


Dimension 125 x 97 x 30mm
Weight 210g
Pole Diameter Φ40 - 50mm

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 170 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-1/ 0316
Coverage Management System
CMS V8.2
Features

 Complete Management Platform for Comba wireless enhancement

products (NE, Network Elements) including repeaters, DAS and etc.

 Real time alarm collection with Alarm history log.

 Real-time or scheduled query for parameters configuration and

status update.

 Scheduled batch processing of commands.

 North Bound Interface (NBI) for integration with other EMS or NMS with SNMP (v2c).

 Support SMS or IP-based communication mode. Optional interface to SMS Center (SMPPv3.3 or 3.4). Support

alarm forwarding to cellular device handset via SMS or email.

 Optional Electronic Map Interface (need local eMap geographical data, SHP format).

 Support Browser – Server configuration over TCP/IP

 Running on standard Server platform.Utilizing proven Microsoft SQL database to achieve scalable, reliable and

secure architecture.

Functional Block Diagram


CMS consists of web server, application server, communication server and northbound interface which are software
modules installed in one physical server hardware.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 171 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-2 / 0316
Specifications
CMS specifications may be varied depending on several factors such as hardware and software configuration levels
and performance variance, NE Qty, communication mode, data transmission link performance, even running time
and etc. Below specifications are typical values based on Comba operational experiences. These specifications
may have some variance during actual operations.

CMS Capacity
NE Qty 10000, under recommended HW & SW configuration

NE data in database One year data

Concurrent login user Qty Maximum 50, recommended 15 for a better performance

CMS Performance
Data Packet Decoding Speed  10 per second

System Response Period  2s (normal operation), 5s (mass data processing)

10000 NEs per hour, under SMSC communication mode


Polling Speed
30000 NEs per hour, under PSD communication mode

Communication mode between CMS and monitored NEs

 SMS. With SMS mode, devices must be equipped with inside modems to send/receive SMS to/from CMS; and

CMS also must be equipped with a modem or directly connecting with SMS Center/gateway to send/receive

SMS to/from devices.

 Packet Switched Data (PSD), such as GPRS, CDMA 1x, HSDPA, etc. With PSD mode, devices must be

equipped with inside modems, and inserted with a PSD enabled SIM/UIM/USIM. In CMS side, an IP Gateway

from Comba is a must if devices be given dynamic IPs from local PSD network.

 Ethernet. With this mode, devices must be equipped with inside Network Interface Card (NIC).

 Circuit Switched Data (CSD) isn’t supported.

North-Bound Interface
Currently CMS supports below NBI to transfer CMS information to other EMS/NMS.
 SNMP Trap, Email, SMS for alarm forwarding.

 Timely Performance/Inventory file for performance/inventory management.

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 172 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-2 / 0316
System Requirements
CMS Server Recommended Hardware Requirements
Processor Intel Xeon E7-2870

Memory 8GByte
Hard disk 500GByte
Network 2 x 100/1000M NIC

Serial Ports At least one available Serial Port

CMS Server Software Requirements


Operating System Windows Server 2012/Linux red hat

Supported Database Applications Microsoft SQL Server 2012/Oracle 11g

CMS Installation Requirements


For the installation of CMS, the CMS server should be open for remote access.

CMS GUI

© 2017 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 173 of 175
Specifications may differ depending on region and customers’ requirements.
DS-Control: 1-0-2 / 0316
General Enquiries
comba@comba-telecom.com
Tel: + 852 2636 6861
Fax: + 852 2637 0966

Sales Enquiries
sales@comba-telecom.com

Support & Technical Services


support@comba-telecom.com

Marketing
marketing@comba-telecom.com

Investor Relations
investorrelations@comba-telecom.com

HR
hr.hk@comba-telecom.com

Website
http://www.comba-telecom.com/

Website Feedback
webmaster@comba-telecom.com
China Headquarters
Comba Telecom Systems China Ltd
Add: No.10 Shenzhou Road,
Guangzhou Science City, China
Tel: +8620 2839 0000
Fax: +8620 2839 0136
Business Card
Corporate & APAC Headquarters
Comba Telecom Systems Holdings Ltd
Add: 611 East Wing, No.8 Science Park West Avenue,
Hong Kong Science Park, Hong Kong
Tel: +852 2636 6861
Fax: +852 2637 0966/+852 2116 6055

Middle East Headquarters


Comba Telecom Limited
Add: Unit 112, Building 5, Gold and Diamond Park,
Al Qouz, Dubai, UAE
Tel: +971 0 4 346 7277
Fax: +971 0 4 346 7288

Europe Headquarters
Comba Telecom Systems AB
Add: Gustavslundsvagen 147,
SE-167 51 Bromma, Stockholm,
Sweden
Tel: +46 8 253 870
Fax: +46 8 253 871

Caribbean and Latin America Headquarters


Comba Telecom Ltda
Add: Av. Doutor Chucri Zaidan nº29 – 29ºandar Conj. 2910/2911,
Vila Cordeiro, Edificio Capital Corporate,
04583-110, Sao Paulo, Brazil
Tel: +55 11 3509 4800
Fax: +55 11 3509 4833

North America Headquarters


Comba Telecom Inc.
Add: 235 Charcot Ave, San Jose, CA 95131, USA
Tel: +1 408 526 0180
Fax: +1 408 526 0181

India Office (Operations Office)


Comba Telecom India P Ltd
Add: G-4 Sector 63, Noida – 201301 U.P, India
Tel: +91 120-4599000
Fax: +91 120-4599001

For more local offices information,


Please visit our website
www.comba-telecom.com

You might also like