You are on page 1of 1

1 2 3 4

d1 : The distance between two magnets in case there is


not rail between them.
30cm d2 : The distance between magnet and magnetic shalter.
d2
H 4cm 7 H
COMPULSORY d1 = min.100mm
TOP LIMIT M?
SWITCH d2 = 6-15 mm
KSR2 818 d1 d2
ML2
ML2
CAR ML1-2
AT TOP ML1
100 ML1
MK
Rail
1000 MK

6 Magnet
G UP DIRECTION G
DECELERATION
DISTANCE
818 818/KSR2
DECELERATION-2
(K7-GENERAL PULSE)
817 817/KSR1
DOWN DIRECTION
DECELERATION
DISTANCE USE MECHANICAL SHALTERS AS
5 1000 817 (KSR1) AND 818(KSR2) LIMIT SWITCHES

AYBEY KPM 206 MONO-STABLE MAGNETIC SHALTER


F F
Strip magnet is placed for ML1, ML2 and STATE
MK magnetic shalters. CONTACT

30cm
'N' POLE OF MAGNET
(30cm strip magnet)

NO MAGNET
SAFE ZONE LIMIT
FOR RELEVELING 4

30cm
'S' POLE OF MAGNET
(30cm strip magnet)

E NO MAGNET E

'N' POLE OF MAGNET 8cm


(Strip magnet)

NO MAGNET
4cm
3 'S' POLE OF MAGNET 8cm
(Strip magnet)

ML2
ML2
D
ML1 D

100 ML1
MK
30cm 8cm 2 1000 MK
ENCODER ML1 and ML2 Floor level sensors that detect the unlocking
ROPE
zone must comply with EN81-1 and EN81-2 article14.1.2.5

SHAFT ENCODER
ENCODER ROPE
C C
TOP SHAFT
15cm CABIN ENCODER
DOOR OPEN ZONE

K7-GENERAL PULSE
1 ENCODER CONNECTION
DOOR ZONE PANEL
CAR ENKODER (NEMICON)
100 Pulse
AT BOTTOM 5-30V DC
CABIN VCC
(Red)
100
(Black)
GND
(Blue)
1000
KSR1 817 A
B (White) E1/ENA
B COMPULSORY E2/ENB B
BOTTOM LIMIT
SWITCH Earth
4cm
15cm
0 WARNING !!!
30cm If parameter A17-UCM CONTROL : 4 then locate ML1 and ML2 shalters approriate
818
817

ML2 with schematics.


If parameter A17-UCM CONTROL : 3 and preopening door and releveling functions
ML2
ML1

ML1 aredisabled then do not use ML1 and ML2 shalters.

MK
ML1, ML2 AND MK ARE PLACED ON CARTOP FOR HIGHER NUMBER OF STOPS (PRM-A05:003)
MK

THE MAP REPEATS ITSELF.


SAFE ZONE LIMIT F/7.5.5.02.67
A A
SENSOR FOR OPEN SHAFT ENCODER MAGNET LOCATION DIAGRAM
This document is a sample for applications. All information contained in
DOOR REVELELING FOR PRE-OPENING DOOR
these materials are subject to change by Aybey Elektronik without notice.
AND RELEVELING. SERIES AC DRW. M. AKKUŞ
Aybey Elektronik assumes no responsibility for any damage, liability, or AYBEY
other loss rising from these inaccuracies or errors. PROJ. AC146 APPRV. M. AYBEY
ELEKTRONİK
REV. 01 DATE 20 JUN 12