You are on page 1of 1

Bracing Workings for BHEL SULs

Developed Length

Sl.No. Dwg No. Assembly Item No. Pipe OD*Wall Thk Final Length Qty (Nos) Weight (Kgs) Thk Width Length Qty (Nos) Weight (Kgs)

1 46044223 Bracing 1 1 Ø 449*12 11619 12 18031.5 12 2450 1373 48 15209

2 12 1819 1373 12 2823

3 18032 18032

4 46044223 Bracing 1 2 Ø 508*12.7 8756 12 15752.4 12 2450 1558 36 12946

5 12 1406 1558 12 2477

6 15752 15423

7 46044223 Bracing 1 6 Ø 610*17,48 11758 12 35482.8 18 2450 1860 48 30904

8 18 1958 1860 12 6175

9 35483 37079

10 46044224 Bracing 2 1 Ø 449*12 12628 12 19200 12 2450 1373 24 7604

11 12 2000 1373 36 9311

12 12 1728 1373 12 2682

13 19200 19597

14 46044199 Horizontal Bracing 1 Ø 508*12.7 18204 6 16942.8 12 2450 1558 42 15104

15 12 1054 1558 6 928

16 16943 16032

Grand Total 54 105410 288 106163

Legends :
1.All dimensions are in MM

2.Straightness shall be within 5mm for the entire length

3.Joint Offset shall be 0.3mm (Max)

4.All joints shall be ground flush after welding

Prepared Reviewed Approved

Sensitivity: LNT Construction Internal Use


#