REV. NO. SHEET NO. DRAWING NUMBER INDEX PLANT NO. 1. TFE - FLUOROCARBON RESIN (TEFLON OR
EQUAL) PROPERTIES SHALL BE AS FOLLOWS:
A. FILLER - 25% GLASS FIBER
B. RELATIVE DENSITY - 2.22 (NOMINAL)
C. TENSILE STRENGTH - 14.5 MPa MINIMUM
(ASTM D-1457)
D. COMPRESSIVE STRENGTH - 12.9 MPa
A MINIMUM AT 0.2% DEFORMATION
(ASTM D-695)
2. TFE PAD SHALL BE CHEMICALLY ETCHED
BOTTOM PLATE OF AND BONDED TO THE CARBON STEEL
7 25 A-64 25 7 PLATE USING A HOT SETTING EPOXY
VESSEL SUPPORT RESIN ADHESIVE.
C 3mm STAINLESS STEEL 3. (A-150mm) x (B-216mm) x 1.315 x 63/64 SHAL
PLATE TYPE 316 AT LEAST BE EQUAL TO THE DESIGN
LOAD IN KG. ON THE SUPPORT. FOR LARGE
VESSELS THE LENGTH (A-150mm) MAY BE
1.5 TFE DIVIDED IN TWO OR MORE EQUAL PARTS,
PROVIDED THE TOTAL BEARING SURFACE
AREA OF THE LOWER TFE ELEMENTS IS
3mm STAINLESS STEEL SUFFICIENT TO SUSTAIN THE DESIGN LOAD.
25 C A-150 25 PLATE TYPE 316 4. MAXIMUM AXIAL MOVEMENT IS 126mm
(63mm IN EACH DIRECTION) AND MAXIMUM
TOP PLATE OR BEAM TRANSVERSE MOVEMENT IS 38mm IN EACH
OF FOUNDATION DIRECTION.
5. ALL DIMENSIONS IN MILLIMETERS
TRANSVERSE MOVEMENT UNLESS NOTED OTHERWISE.
B
FORMERLY STD. DWG. AD-036221; SHT. 001; REV. 03
7 25 B-64 25 7 REV.
DATE BY JO/EWO DESCRIPTION CHKD. CERT. APPD.
NO.
AXIAL MOVEMENT
LIBRARY DRAWING SAUDI ARABIA
PLANT NO. INDEX DRAWING NUMBER SHEET NO. REV. NO.
CADD-02
Copyright©Saudi Aramco 2009. All rights reserved.