10 THK. STIF.

HEA 200 T NOTES


TOP AND BOTT.
" 1 -ALL DIMENSIONS ARE IN MILLIMETERS.
"S
=
7T 2 -ALL WELDS SHALL BE DONE AT SHOP.
0.
L BEAM
C 3 -HIGH STRENGTH FRICTION TYPE BOLTS SHALL
COLUMN BE IN ACCORDANCE WITH ASTM A325 TYPE 1
(SEE NOTE No.9) OR EQUIVALENT APPROVED BY AUTHORIZED
REPRESENTATIVE OF OWNER.
4 -NUTS AND WASHERS SPECIFICATION FOR
SEE NOTE 5 ASTM A325 BOLT SHALL BE ASTM A563 DH
AND ASTM F436 RESPECTIVELY.
TOP VIEW
200 5 -COLUMN FLANGE WIDTH>BEAM FLANGE WIDTH.

6 -BEARING TYPE JOINTS SHALL NOT BE USED.


50 100 50
7 -WELDS SHALL BE AS PER AWS D1.1
TYP. A HEA 200
8 -STRUCTURAL MATERIAL SHALL BE DIN ST 37

1
OR EQUIVALENT.
9 -DIMENSION "S" OF NON DIMENSIONED FILLET
WELDS SHALL BE AT LEAST EQUAL TO 0.7
5 COLUMN TIMES THE MINIMUM THICKNESS OF THE

60 55
10 190 SMALLEST ELEMENTS TO BE CONNECTED.
10 -DESIGN PROCEDURES TO BE IN ACCORDANCE
2 4
HEA 200
/22 HOLES FOR
8O WITH AISC MANUAL AND MATERIALS TO BE
M20 BOLTS IN ACCORDANCE WITH DIN STANDARDS.
380

130
.

400
P
L . 20 THK.

60
6

75
3
20
20 THK. HAUNCH CUT
FROM BEAM
END P
L. SECTION COL.VARIES
A

ELEVATION SECTION A-A


C
B
A
REV. DESCRIPTION DATE
2
IRANIAN PETROLEUM STANDARDS
45 45

NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION

45
2
STRUCTURAL STEEL CONNECTIONS
2

MOMENT CONNECTION
2
2

FLUSH END PLATE FOR HEA 200 BEAM


DETAIL1 DETAIL2 DETAIL3 DETAIL4 DETAIL5 DETAIL6 DATE DRAWING No. SHEET REV.
1
IPS-D-CE-150 1