Professional Documents
Culture Documents
11'-921" 11'-921" 4. ALL REINFORCEMENT SHALL BE DEFORMED HOT ROLLED STEEL BARS,
1'-0" 1'-0" 1'-0" GRADE 60 WITH SPECIFIED YIELD STRENGTH OF NOT LESS THAN 60,000 PSI.
M.S Angle
2"x2"x 1/4" Barbed wire 5. USE BITUMEN IMPREGNATED SOFT BOARD BETWEEN EXPANSION JOINT AT COLUMNS.
6. USED 12" THICK PLASTER ON BLOCK MASONRY
7. CLEAR COVER FOR CONCRETE SHALL BE
LEV.+10'-0" AS FOLLOWS.
A) RAFT: SIDES & BOTTOM = 2" TOP =2"
C) RETAINING WALLS: EXTERNAL FACE = 1 12" INTERNAL FACE =1 12"
R.c.c column R.c.c column R.c.c column
D) COLUMNS : SIDES 1 12"
4'-0"
Block Masonry Wall Block Masonry Wall 8. EXPANSION JOINT SHALL BE PROVIDED AT EVERY 100'-0"
LEV.+6'-0" 9. UNLESS NOTED MINIMUM OVERLAPS IN REINFORCEMENT SHALL
2'-0" BE AS PER FOLLOWS.
A) 47 TIMES BAR DIA FOR BARS IN COMPRESSION.
M.S Angle B) 47 TIMES BAR DIA FOR BARS IN TENSION.
2"x2"x 1/4" 8"
1'-6"
6'-0"
8"
2'-3"
8"
LEV.+10'-0" Block Masonry
9"
LEV.+6'-0" 6" 6"
2'-0"
LEV.-2'-0"
6" 12"
9" 12"
LEV.-3'-0" (TYP.) (TYP.)
6'-0"
10'-0"
MAIN STEEL
2'-0"
LEV.+10'-0" COLUMN STIRRUPS
1"
R.c.c column 1'-6"
LEV.-2'-0"
47 BAR DIA
Block Masonry Wall
4'-0"
(TYP.)
12"
12"
LEV.-3'-0" 6" 6"
LEV.+6'-0"
6"
6"
6"th. C.C. BED 1:4:8
2'-0"
MAIN STEEL 1'-6" 1'-0" 1'-6"
6'-0"
LEV.-2'-0"
12"
12"
LEV.-3'-0" (TYP.)
2'-0"
1:4:8
6"
12"
LEV.-2'-0"
LEV.-3'-6" COMPACTED EARTH
REV. DATE DESCRIPTION
95% DRY DENSITY
6" 12"
NO.
LEV.-3'-0"
6"th. C.C. BED 1:4:8
COMPACTED EARTH
LEV.-3'-6" 95% DRY DENSITY
12"
1028'-0"
Check by: Scale : Date :
28'-0" 100'-0" 100'-0" 100'-0" 100'-0" 100'-0" 100'-0" 100'-0" 100'-0" 100'-0" 100'-0"
Expansion joint Expansion joint Expansion joint Expansion joint Expansion joint