Tank No : PJ042-AST001 Tank Service: Raw Acid Tank API 650, 13th Ed,March-2020,Errata 1, January 2021 DESIGN DATA Design code API- 650 Geometric/Working Capacity 72.8 / 55 m³ Design Pressure Int./Ext. 0/0 kPa Type of tank Supported CR Design/Operating temp 50 /40 °C Tank inside diamter 5.00 m Liquid Stored 98% Sulphuric Acid Tank height 3.70 m Sp.gr of liquid 1.83 Design Liquid height 3.30 m TANK WEIGHTS We Fabrication Weight 10.10 Ton Wo Operation weight 128.70 Ton Wer Erected Weight 10.10 Ton Wtl Test Liquid weight 72.65 Ton Wp Product weight 118.58 Ton Wt Hydro-test weight 82.80 Ton SHELL LINE LOADS (P) (PER LINEAR OF CIRCUMFERENCE) Ps Shell dead load+Insulation load+Appurtenace 3.37 kN/m ↓ Pr Roof(insulation+structure+appurt.) dead load(applied to shell) 1.85 kN/m ↓ Prl Roof Live load 1.50 kN/m ↓ Prv Roof Partial vaccum load 0.00 kN/m ↓ Pe Seismic line load: 4*Mrw/(πD²) 13.23 kN/m ↓↑ Pw Wind line load:4*Mw /(πD²) 6.72 kN/m ↓↑ TANK BOTTOM LOADS (q) qp Product load :Wp/(π/4*D²)*9.806 59.2 kN/m2 ↓ qip Design Pressure :π/4*D²*P 0.0 kN/m2 ↓ qt Test load :Wtl/(π/4*D²)*9.806 41 kN/m2 ↓ qtp Test Pressure :π/4*D²*Pt 0.00 kN/m2 ↓ qb Bottom Plate load :tb*7.85*9.806/1000 0.77 kN/m2 ↓ LOADING DATA SHELL LINE LOADS LOAD ON BOTTOM LOAD ON ANCHOR BOLTS P kN/m ↓ q kN/m2 ↓ UPLIFT (U) SHEARING(S) Operating Po 6.71 qo 60 -- -- Hydrotest Pt 6.71 qt 43 -- -- Operating + Earthquake Poe 19.95 qoe 60 149 kN ↑ 172 kN → Operating + Wind Pow 13.43 qow 60 14 kN ↑ 32 kN → Po=Ps+Pr+Prl+Prv Pt=Ps+Pr+Prl Poe=Po+Pe Pow=Po+Pw qo=qp+qip+qb qt=qt+qtp+qb qoe=qp+qip+qb qow=qp+qip+qb OVERTURNING MOMENT AND BASE SHEAR Ringwall Overturning Moment DUE TO EARTHQUAKE DUE TO WIND PRESSURE (acting @ base of tank shell perimeter) Mrw = 260 kN-m MW = 132 kN-m Slab Overturning Moment Ms = 369 kN-m (used for slab and pile cap design ) Base shear Fs = 172 kN FW = 32 kN P Anchor Bolts Size x Nos : M24 x 8 U Tank I.D =5.00 m