You are on page 1of 1

Tank Capacity Calculation

Doc No. : - Tank service : Steam Condensate tank


Tank No.: U-FA 103 Rev : 0

Tank Geometry Vertical


Inside Diameter Di 3200 mm
Total height of shell H 4000 mm

Center line of tank


HLL 3700 mm

4000 mm
Net Storage
Capacity

LLL 300 mm
±0

Partial
Liquid Total
Volume betn
Levels Volume
levels
Shell Top edge H 4000 mm 2.5 m³ 32.4 m³
High Liquid Level HLL 3700 mm 27.4 m³ 29.9 m³
Low Liquid Level LLL 300 mm 2.50 m³ 2.5 m³
Tank Bottom 0 mm 0.0 m³

Net Storage Capacity (Between LLL & HLL) 27.4 m³


Maximum capacity ( bottom plate to HLL) 29.9 m³
Nominal capacity (Geometric Volume) 32.4 m³