You are on page 1of 1

NO NOTES

1. THIS DRG SHALL BE READ IN CONJUNCTION WITH


RELEVANT ARCH. & SERVICES DRGS.
01 02 2. THIS BLDG. IS DESIGNED FOR ONLY GROUND FLOORS ONLY.
2

2100 3. SAFE BEARING CAP. IS TAKEN AS 12.8 T/M AT 1.5M DEEP.

4. ALL LOOSE POCKETS FOUND IN EXCAVATION SHALL BE


REPLACED BY LEAN CONC. (1:4:8).
5. CONC. MIX M-20 FOR ALL RCC WORK U.N.O.
6. CLEAR COVER TO OUTER BARS SHALL BE AS FOLLOW:-
FTG= 50, COLS.=40, BEAMS=25, SLABS = 20MM.

A 7. LAP LENGTH FOR ALL BARS SHALL BE 49X DIA OF BARS.

8. 250TH. & 125MM TH. BLOCK WORK SHALL BE IN


CEM. SAND 1:6 & 1:4 RESPECTIVELY.
1800

9. HIGH STRENGTH DEFORMED BARS OF YIELD STRENGTH


2
500 N/mm SHALL BE USED AS REINF. FOR ALL RCC WORK.
10. FOR DESIGN PURPOSES SEISMIC ZONE-II AS PER IS1893
IS CONSIDERED.

475 300
B

100

450
600

100
250
GROUND FLOOR FRAMING PLAN
SECTION A-A

01 02
2100
ARCH ERA ARCHITECTS
LOWER GROUND, A-64, SHUSHANT LOK, PHASE
III, SECTOR 57, GURGAON, HR, 122002
A Mob. 9015575905, Email - archerastudio@gmail.com

District Mineral Foundation,


E:\Arch Era\Arch Era Projects\18 DMF\TYPICAL PLANS\LOGO.jpg
1800

Sundergarh

(A Government of India Enterprise)

PERCEPTIONS
11/165 SECTOR-11, VASUNDHARA,
GHAZIABAD
PH :-9810575453
email:- perceptions.str@gmail.com

0.1L¹ 0.3L¹ 0.3L²


0.15L¹ 0.15L²

>P/2 P P SLAB SCHEDULE GROUND FL. & TERRACE LVL.


>P/2
REINFORCEMENT FRAMING PLAN & BEAM SECTIONS
DRINKING WATER SHED
0.15L¹ 0.25L¹ 0.25L² S.NO. SLAB SLAB BOTTOM BARS TOP BARS
L1 L2 MARK THICK SHORT DIST. LONG DIST. SHORT DIST. LONG DIST.
(A=A1+A2). (B=B1+B2). C1 D1 R0
SIMPLIFIED RULES FOR CURTAILMANT OF BARS - SECTION THROUG MIDDLE STRIP
1. S1 125 8 @150C/C 8 @150C/C 8 @150C/C 8 @150C/C