You are on page 1of 1

NOTES:

1. ALL DIMENSIONS ARE IN MILLIMETERS, UNLESS OTHERWISE SPECIFIED.


2. NO DIMENSION SHALL BE MEASURED, ONLY WRITTEN DIMENSIONS ARE
TO BE TAKEN AS CORRECT.
3. EFFECTIVE COVER OF 50mm SHALL BE PROVIDE ON BOTH SIDES.
4. ALL SPLICES AND LAPS SHALL BE PROVIDED AS PER IS 456:2000.
5. MINIMUM M30 CONCRETE GRADE SHALL BE USED. REINFORCEMENT BARS OF
TYPE Fe-500 SHALL BE USED AS PER IS 456:2000.


TUNNEL AXIS VERTICAL ROAD
AXIS

40
12Ø @ 160 C/C
12Ø @ 160 C/C

0
12Ø @ 160 C/C
12Ø @ 160 C/C

R4
92
0
GEOTEXTILE AND
WATER PROOFING

F8
500 3500 3500 500

60
R70

3216
F1 0
R554
400mm THICK CAST
IN SITU INNER
750 750 CONCRETE LINING
F3 F2 L

POINTS X Y

F5 F4 F0 0.0 0.0

F1 0.00 3330
1916

2290
F2 270 2290
PRECAST CONCRETE
SLOTTED CHANNEL F3 -270 2290
ELEMENT
(CAST FROM AT CONCRETE) 1020 F4 1780 2150
1010
2% 2.5% F0 2.5% 2% F5 -1780 2150
F7 F6
F6 3340 -10
550

F7 -3340 -10
910

R1
SIDEWALL DRAINAGE EMBEDDED
R1.50

F8 0.0 19200
CABLE DUCT

.50
IN POROUS CONCRETE
200

MORTAR BED 100MM


400

CONCRETE M30

LONGITUDINAL DRAINAGE
PIPE HOLE 400mm THICK CAST IN SITU
12Ø @ 160 C/C INVERT CONCRETE LINING

12Ø @ 160 C/C


7000
CARRIAGEWAYWIDTH

LINING DETAIL CLASS- L


WITH INVERT ARCH
SCALE 1:50

TUNNEL -1 MAIN TUNNEL LINING DETAIL