You are on page 1of 1

8 7 6 5 4 3 2 1

NOTES:
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE
IN METERS UNLESS OTHERWISE MENTIONED.
2. DRAWING SHOULD NOT BE SCALED. ONLY WRITTEN
C/C OF PIER/PILECAP C/C OF PIER/PILECAP DIMENSIONS ARE TO BE FOLLOWED.
1000 TOP OF PIERCAP TOP OF PIERCAP 3. GRADE OF CONCRETE
A. PILE ------- M35

1200
160
1200
B. PILE CAP ---- M35

1800

1800
2800
C. PIER ------ M35

600
100 100
PIER CAP SOFFIT PIER CAP SOFFIT D. PCC ------- M15

600
1000 1000
7000 4. ALL RCC WORK SHOULD CONFORM TO RELEVANT IRC
F 12200
CODES & MORTH SPECIFICATIONS. F
WALL TYPE PIER 5. INITIAL PILE LOAD TEST SHALL BE CARRIED OUT AS PER
IS:2911-PART-IV.
A A
6. 6mm THICK MS LINER SHALL BE PROVIDE UP TO REFUSAL
1350

8000
LEVEL/HARD ROCK.

7. LINER BOTTOM SHOE SHALL BE 600mm HEIGHT AND 8mm


THICK.
8. THE SOCKET LENGTH FOR PILE SHALL BE 3x1.2 = 3.6m.
9. FOUNDING LEVEL SHOWN IS AS PER GEOTECHNICAL
500

PROPOSED GROUND LEVEL PROPOSED GROUND LEVEL INVESTIGATION ANY VARIATION MORE 50mm IN FOUNDING

E TOP OF PILE CAP TOP OF PILE CAP LEVEL SHALL BE INFORMED TO DESIGN CONSULTANT.
E
MIN.

PILE CAP 10 MINIMUM PILE LENGTH CONSIDERED IS 8m + SOCKET LENGTH.


1800

1800
150 C/C OF PILE (TYP)
50

C.O.L C/C OF PILE (TYP) SOFFIT OF PILE CAP SOFFIT OF PILE CAP
150mm Thk. PCC
850 3600 3600 850
850 3000 850
MS LINER
8mm Thk
UP TO
LEGEND:
ROCK LEVEL ROCK LEVEL
ROCK LEVEL (START OF SOCKETING) (START OF SOCKETING) C.O.L. : CUT OF LEVEL
P.G.L : PROPOSED GROUND LEVEL
10665

THK. : THICKNESS
D B B

MIN. : MINIMUM D
: CONSTRUCTION JOINT
1200 Ø PILE (TYP)

FOUNDING LEVEL FOUNDING LEVEL


(END OF SOCKETING) (END OF SOCKETING)

LONGITUDINAL ELEVATION TRANSVERSE ELEVATION


(SCALE 1:50) (SCALE 1:50) FOR LEVELS REFER SEPARATE DRAWING

C/C OF PIER

1200 Ø PILE (TYP)


C/C OF PIER

C C
(TYP)
1350

7000 SECTION B-B


SECTION A-A (SCALE 1:50)
MAXIMUM VERTICAL LOAD ON PILE - 360T
(SCALE 1:50) MAXIMUM HORIZONTAL LOAD ON PILE - 5.0T
250
150

C OF PIER/PILECAP
OF C/C PIER / PILECAP

850

DIRECTION
TRAFFIC

250
TYP

COORDINATE
4700
3000

WALL TYPE PIER


(E, N)
B B
850
150

150 850 3600 3600 850 150


8900
PLAN AT PILECAP TOP
(SCALE 1:50)

PROJECT : CLIENT : CONTRACTOR : DESIGN CONSULTANT : REINFORCEMENT DETAILS


OF PIER, PILE CAP, PILE
A FOR P1 TO P10
DATE SCALE DRAWING NO
A
AS SHOWN AES-RJN-R-142

EDUCATION PURPOSE ONLY EDUCATION PURPOSE ONLY EDUCATION PURPOSE ONLY EDUCATION PURPOSE ONLY NAME SIGN.

DRAWN BY

DESIGN BY

8 7 6 5 4 3 2 1

You might also like