A

02 01 04 03 02 02 08 06 07 02 NOTES:
GENERAL:
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
OTHERWISE MENTIONED.
LEGENDS : 2. ONLY WRITTEN DIMENSIONS ARE TO BE FOLLOWED. NO DRAWING SHALL BE
R/F - REINFORCEMENT SCALED.
- BOTTOM REINFORCEMENT / FAR FACE 3. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH HIGHWAY PLAN & PROFILE
250 DRAWINGS & OTHER RELATED DRAWINGS
500 500 - TOP REINFORCEMENT / SOIL FACE
250 MATERIALS:
250 500 500 250 SCHEDULE OF LAP LENGTH FOR REINFORCEMENT 4. CLEAR COVER TO ALL REINFORCEMENT BAR INCLUDING STIRRUPS SHALL BE AS
FOLLOWS:
14
FAVOURABLE BOND UNFAVOURABLE BOND
12000

12000

14 14 14 WALL
CONCRETE
A % OF GRADE M25 M30 M35 M40 M25 M30 M35 M40 SOIL FACE :75mm TOP BOX :45mm
LAPPED BAR FAR FACE :45mm BASE BOX :75mm
12 11
< 25% 47 x Ø 40 x Ø 36 x Ø 34 x Ø 68 x Ø 58 x Ø 52 x Ø 49 x Ø 5. REINFORCEMENT STEEL SHALL BE OF HYSD (TMT) BARS OF FE-500D, CONFIRMING
> 25% & < 33% 55 x Ø 46 x Ø 42 x Ø 40 x Ø 79 x Ø 66 x Ø 61 x Ø 58 x Ø TO IS-1786.
> 33% & < 50% 66 x Ø 56 x Ø 51 x Ø 48 x Ø 95 x Ø 81 x Ø 73 x Ø 69 x Ø 6. GRADE OF CONCRETE SHALL BE AS FOLLOWS:
> 50% NOT ALLOWED RCC BOX : M-30
PCC : M-15
FOR DETAILS OF FAVOURABLE BOND AND UNFAVOURABLE BOND CONSTRUCTION:
CONDITIONS REFER CLAUSE 15.2.3 OF IRC:112-2011.
7. NUMBER OF BARS SHOWN AS DOT SHALL NOT BE COUNTED, NUMBER OF BARS AND
NOTE FOR BOX TYPE STRUCTURES: SPACING INDICATED SHALL BE ADOPTED.
BARS INCLUDING DISTRIBUTION STEEL ON TOP FACE OF TOP & BOTTOM BOX 8. LAPPING OF REINFORCEMENT SHOULD BE AS PER PROVISIONS OF IRC-112:2011.
SHALL BE CONSIDERED IN UNFAVOURABLE BOND CONDITION AND ALL OTHER
9. IF ANY AMBIGUITY FOUND IN DRAWINGS OR AT SITE BRING IT TO DESIGNER'S
BOTTOM SALB R/F PLAN TOP SLAB R/F PLAN BARS SHALL BE CONSIDERED IN FAVOURABLE BOND CONDITION.
NOTICE BEFORE EXECUTIONS.
(BAR MARK 10 , 23a & HAUNCH LINES NOT SHOWN IN PLAN FOR CLARITY) (BAR MARK 09 & HAUNCH LINES NOT SHOWN IN PLAN FOR CLARITY)
(SCALE-1:40) (SCALE-1:40)
500 500
14 02 08 02 08 11 02 02 08 14 03 04
12
SCHEDULE OF REINFORCEMENT
250

BAR NOS./
07 06 17 12 MARK SIZE SPACING SHAPE REMARKS
800

800
09 09 01 12 @220c/c 975 2350 975
18
08 08 675
02 12 @220c/c 2380
675
01 02
18 03 12 @400c/c 130 130
2350
SECTION A-A 04 12 @400c/c 130 2350 130
(SCALE-1:30)
200
02 05 05 02 05 12 @220c/c 2380
200
2000
13 22 22 13
06 12 @400c/c 350 2350 350
07 12 @400c/c 2350
250 2000 250 03 04 08 12 @220c/c 1005 2410 1005
MAIN REINF. 710
09 10 @250c/c 200
200

BOTTOM
01 B 01
10 10 @250c/c
200

BOX
200 710
600 04 03 600
800

800
10 11 8 @300 c/c 136 11850 136
10
1000
12 8 @300 c/c 106 11850 106

250
01 02 12
13 8 @300 c/c 118 11850 118
MAIN REINF. DISTRIBUTION
01 02 02 01 12 02 01 02 SECTION B-B 14 8 4x4=16 106 11850 106
(SCALE 1:30) 1070
14 500 500 14 17 10 @250 c/c 865 135 1230
18 8 10 NOS 118 11850 118
B
R/F DETAILS OF BOX 22 8 @300 c/c 118 11850 118
(SCALE-1:40) SHEAR LINKS
23a 8 @300 c/c (4 NOS. PER M. WIDTH)
NOTE: BAR MARK 15 , 16 , 19 TO 21 23a NOT USED.