You are on page 1of 1

LEGEND:

450 THK : THICKNESS NOS. : NUMBERS


10 MM Ø -150 MM C/C Ld : DEVELOPMENT LENGTH CL : CENTER LINE
100 TYP. : TYPICAL MKD. : MARK

175
225 C/C : CENTER TO CENTER DIA : DIAMETER
mm : MILLIMETER REINF : REINFORCEMENT

50
NOTES:
12 MM Ø -150 MM C/C
1. ALL DIMENSION ARE IN MM (UNLESS OTHERWISE
SPECIFIED).

750
2. ONLY WRITTEN DIMENSION SHALL BE FOLLOWED.
12 MM Ø -150 MM C/C NO DIMENSION SHALL BE SCALED.
3. EXPANSION JOINT IN CRASH BARRIER SHALL BE
1100

150
1175

PROVIDED AT THE LOCATION OF EXPANSION JOINT


UTILITY DUCT OF DECK SLAB.
(150 DIA. PVC PIPE) 4. GRADE OF CONCRETE -
M40 (FOR CRASH BARRIER).
M15 (FOR CURTAIN WALL)

250
WEARING COAT 5. GRADE OF HYSD REINFORCEMENT -Fe 500
DECK SLAB/TOP SLAB Ld (TYP) Ld (TYP) 6. CLEAR COVER TO ALL REINFORCEMENT SHALL BE

100
-40 MM
7. LAP LENGTH AND ANCHORAGE LENGTH FOR M-40
GRADE OF CONCRETE SHALL BE AS BELOW:
75

TIE WITH SIDE REINFORCEMENT & CONDITION


LAP ANCHORAGE
REMARKS
LENGTH LENGTH
BOTTOM REINFORCEMENT
FAVORABLE 48Ø 34Ø 50% LAPPING
DRAINAGE SPOUT
REINFORCEMENT DETAILS OF UNFAVORABLE 69Ø 49Ø 50% LAPPING

CRASH BARRIER 8. THE DRAWING SHALL BE READ CONJUNCTION WITH


ALL OTHER RELEVANT DRAWINGS
DIMENSION DETAILS OF 9. REINFORCEMENT OF SHOULD BE SUITABLE
ANCHORED IN TOP SLAB OF SUPER STRUCTURE.
CRASH BARRIER

You might also like