You are on page 1of 1

LABORATORIUM STRUKTUR

FAKULTAS TEKNIK JURUSAN TEKNIK SIPIL


UNIVERSITAS MUHAMMADIYAH METRO
JL.Ki Hajar Dewantara No. 116 Iringmulyo Kota Metro Telp./Fax. (0725) 42445 - 42454 Kode Pos 34112
COMPRESSIVE STRENGTH OF CONCRETE
MIX DESIGN BBWS MESUJI SEKAMPUNG
Done for : PT. GENERAL INFRACO MANDIRI
Project : Pekerjaan peningkatan DI Batanghari Utara
Test Machine : Universal Testing Machine (UTM) / Compressive Strength
Calibration Certificate : 3727.EPE-00.04.20/21/April/2020
Mutu : K-225 Insitu

Date Of Date Of Slump Age of LOAD Weight Of Concrete Corection Estimation Concrete
LOAD
NO Code Mixing TEST TEST SPCN SPCN Strength Factor of Age Strength at
(Cm) (Day) (KN) (Kg) (TON) (kg/cm²) 28 days (kg/cm²)
A B C D E F G H I J =( I*1000) / Δ K L = ( J/K )
1 1 10/08/2021 07/09/2021 11,00 28 327,00 12,90 33,33 227,378 1,00 227,38
2 2 10/08/2021 07/09/2021 11,00 28 350,00 12,80 35,68 243,371 1,00 243,37
3 3 10/08/2021 07/09/2021 11,00 28 318,00 13,00 32,42 221,120 1,00 221,12
Rates of Concrete's Strength (Kg/cm2) 230,623
Luas Area Silinder = 176,625 cm²

Catatan :
Syarat umur 28 hari : 1

Diperiksa Oleh, Diuji dan dihitung Oleh,

Mufidah, S.T.,M.T. Bayu Tri Atmoko