Concrete Compressive Strength Test Report


Client KRC Infrastructure and Projects Pvt.Ltd Doc. Number: 779
Site KRC Infrastructure and Projects Pvt.Ltd, IT/ITES Sample Reference: 191341
(Special Economic Zone), GO-B2 Area, Sampling Date: 14-03-2022
S.No.65, Kharadi Villagw, Taluka-Haveli, Dist-Pune411014
Grade: M 40

Maximum Aggregare Size(mm) Cement Type Approx Sump Air


20 MM OPC Vasavadatta 110 ± 25 mm 1.00%
Aggregate Type Admixture Type Design Type
Wagholl BASF Production

Age Weight Max Load Strength Avg. Stregth


Testing Date
(Days) (KG) (KN) (Mpa) (Mpa)
7 8.88 755.3 33.57 32.94
31-05-2019 7 8.86 742.6 33
7 8.84 725.8 32.26
28 28 1202.6 53.45 53.91
24-06-2019 28 28 1230.6 54.69
28 28 1205.8 53.59

Remarks: As per General code of Practice 28 days strength should be around 43Mpa or grade of concrete. Average Strength
gained by concrete at 28 days is 51.91Mpa. Concrete with respect to strength compliance is of Excellent Quantity.
In all cases 28 days Compressive Strength table II of IS 456 shall alone be the criteria for strenth compliance
of concrete.
Our Criteria For Quality of Concrete:
7 Days Strength in Mpa 28 Days Strength in Mpa
Grade
Average Good Excellent Fall Good Excellent
M 40 Below 27 27 to 30 Above 30 Below 43 to 46 Above 46