You are on page 1of 19

17.12.

2018
DEPARTMENT OF CIVIL ENGINEERING
CONCRETE CUBE TEST

Test report Reference No. : Lr No.1 AE / Div /2018 / Date: 17.10.2018


Date of Testing : 15.12.2018
Casting Date : 17.11.2018
Identification Mark : NIL
Mix : M20 Grade
Name of work : Construction of Building for Periyar University
Constituent Arts and Science college at
Uthiragidikaval village in Senthamangalam.
Dept for whom
Test is carried out : Executive Engineer,
Public Works Department,
Technical Education Division,
Trichy - 20

No of Test Samples : 3 No .of Concrete Cubes


Footing Concrete with 28 days curing

Compressive
Size of the
Sl. No Identification Load in (N) strength Remarks
sample in mm
N/mm2
1 150X150X150 NIL 575700 25.59 28 days
2 150X150X150 NIL 562500 25.00 -do-
3 150X150X150 NIL 576800 25.64 -do-
Average 25.41N/mm 2

PRINCIPAL
26.11.2018
DEPARTMENT OF CIVIL ENGINEERING
CONCRETE CUBE TEST

Test report Reference No. : Lr No.1 AE / Div /2018 / Date: 17.10.2018


Date of Testing : 24.11.2018
Casting Date : 17.11.2018
Identification Mark : NIL
Mix : M20 Grade
Name of work : Construction of Building for Periyar University
Constituent Arts and Science college at
Uthiragidikaval village in Senthamangalam.
Dept for whom
Test is carried out : Executive Engineer,
Public Works Department,
Technical Education Division,
Trichy - 20

No of Test Samples : 3 No .of Concrete Cubes


Footing Concrete with 7 days curing

Compressive
Size of the
Sl. No Identification Load in (N) strength Remarks
sample in mm
N/mm2
1 150X150X150 NIL 343400 15.26 7 days
2 150X150X150 NIL 342300 15.21 -do-
3 150X150X150 NIL 355400 15.79 -do-
Average 15.42 N/mm2

PRINCIPAL
14.11.2018

DEPARTMENT OF CIVIL ENGINEERING


TMT STEEL ROD TESTING REPORT
Test report Reference No. : Lr No.1 AE / Div /2018 / Date: 17.10.2018
Date of Testing : 12.11.2018
Name of work : Construction of Building for Periyar University
Constituent Arts and Science college at
Uthiragidikaval village in Senthamangalam.
Dept for whom Test is carried
out : Executive Engineer,
Public Works Department,
Technical Education Division,
Trichy - 20
Yield Specimen
Tensile stress % of
Sl.No Specimen size in mm stress in weight in Kg
in Kg/mm 2
Elongation
Kg/mm2 for 1m
1. 8 mm 1. 468 585 21.1 0.398
2. 470 588 21.2 0.396
3. 467 586 21.5 0.397
2. 10 mm 1. 458 584 22.7 0.606
2. 462 580 21.5 0.611
3. 464 586 22.0 0.620
3. 12 mm 1. 454 559 23.0 0.884
2. 460 565 23.2 0.890
3. 470 575 23.3 0.895
4. 16 mm 1. 455 568 22.7 1.980
2. 460 555 22.1 1.990
3. 465 560 21.7 1.940
5. 20 mm 1. 453 542 23.4 2.400
2. 458 545 23.0 2.460
3. 460 548 23.2 2.480
6. 25 mm 1. 441 584 21.6 3.842
2. 450 588 21.8 3.860
3. 455 592 22.0 3.820
PRINCIPAL

14.11.2018

DEPARTMENT OF CIVIL ENGINEERING


BRICKS TEST

Test report Reference No. : Lr No.1 AE / Div /2018 / Date: 17.10.2018


Date of Testing : 12.11.2018
Name of work : Construction of Building for Periyar University
Constituent Arts and Science college at
Uthiragidikaval village in Senthamangalam.
Dept for whom Test is carried
out : Executive Engineer,
Public Works Department,
Technical Education Division,
Trichy - 20

Sample : 3 No. of fly ash


Brick size: 83/4 “X 41/4”X23/4”

S .N Size of the sample Identification Compressive Water absorption


o size in mm On sample strength in N/ mm2 in %
1 83/4 “X 41/4”X23/4” RS 8.36 12.80
2 83/4 “X 41/4”X23/4” SELLY 8.34 12.72
JAI
3 83/4 “X 41/4”X23/4” 8.38 12.93
ANJANEYA
PRINCIPAL

14.11.2018

DEPARTMENT OF CIVIL ENGINEERING


TEST ON WATER

Test report Reference No. : Lr No.1 AE / Div /2018 / Date: 17.10.2018


Date of Testing : 12.11.2018
Name of work : Construction of Building for Periyar University
Constituent Arts and Science College at
Uthiragidikaval village in Senthamangalam.
Dept for whom Test is carried
out : Executive Engineer,
Public Works Department,
Technical Education Division,
Trichy - 20

Sample : Water sample from Bore well .

Permissible limit as per


S. NO
Test Test value BIS 456:2000

1 PH - value 7.5 6-8


2 Hardness 92 ppm 75 -115 ppm
3 Chloride content 180 ppm Less than 250 ppm
4 Sulphide content 170 ppm Less than 250 ppm
5 Total dissolved solids 315 ppm Less than 500 ppm

PRINCIPAL
14.11.2018

DEPARTMENT OF CIVIL ENGINEERING


SIEVE ANALYSIS OF FINE AGGREGATES (M-Sand)

Test report Reference No. : Lr No.1 AE / Div /2018 / Date: 17.10.2018


Date of Testing : 12.11.2018
Name of work : Construction of Building for Periyar University
Constituent Arts and Science College at
Uthiragidikaval village in Senthamangalam.
Dept for whom Test is carried
out : Executive Engineer,
Public Works Department,
Technical Education Division,
Trichy – 20

Sample : M-Sand (fine Aggregate)

TEST RESULT
Cumulative Cumulative
Percentage of
IS sieve size BIS limits Weight percentage of percentage of
Weight
retained Weight Weight
Retained
retained passing
10 mm 100 - - - 100
4.75 mm 90-100 200 5.0 5.0 95.0
2.36 mm 60-95 1500 29.0 34.0 66.0
1.18 mm 30-70 1600 31.0 65.0 35.0
600 µ 15-34 850 18.0 83.0 17.0
300 µ 5-20 600 11.0 94.0 6.0
150 µ 0-10 250 6.0 100 0

PRINCIPAL

14.11.2018
DEPARTMENT OF CIVIL ENGINEERING
SIEVE ANALYSIS OF COARSE AGGREGATES

Test report Reference No. : Lr No.1 AE / Div /2018 / Date: 17.10.2018


Date of Testing : 12.11.2018
Name of work : Construction of Building for Periyar University
Constituent Arts and Science College at
Uthiragidikaval village in Senthamangalam.
Dept for whom Test is carried
out : Executive Engineer,
Public Works Department,
Technical Education Division,
Trichy – 20

Sample : 20 mm HBG metal (Coarse Aggregate)

TEST RESULT
Cumulative
Percentage of Cumulative
IS sieve size BIS limits Weight percentage of
Weight percentage of
retained Weight
Retained Weight passing
retained
40 mm 100 - - - 100
20 mm 95-100 1150 4.60 4.60 95.4
10 mm 30-70 10700 42.80 47.60 52.6
4.75 mm 10-35 12650 50.6 98.00 20.0
2.36 mm 0-5 500 2.00 100 0

RESULTS:

Abrasion Value : 42%

Aggregate Impact value : 38%

PRINCIPAL

14.11.2018
DEPARTMENT OF CIVIL ENGINEERING
PHYSICAL TEST ON CEMENT

Test report Reference No. : Lr No.1 AE / Div /2018 / Date: 17.10.2018


Date of Testing : 12.11.2018
Name of work : Construction of Building for Periyar University
Constituent Arts and Science College at
Uthiragidikaval village in Senthamangalam.
Dept for whom Test is carried
out : Executive Engineer,
Public Works Department,
Technical Education Division,
Trichy – 20
Type of Cement : Ordinary Portland cement, 53 Grade.

Brand name of the Cement : PENNA

Normal Consistency : 35 %

Initial setting time : 45 min

Final setting time : 290 min

Fineness of the Cement


(Residue) : 4.5%

PRINCIPAL

14.11.2018
DEPARTMENT OF CIVIL ENGINEERING
SIEVE ANALYSIS OF COARSE AGGREGATES

Test report Reference No. : Lr No.1 AE / Div /2018 / Date: 17.10.2018


Date of Testing : 12.11.2018
Name of work : Construction of Building for Periyar University
Constituent Arts and Science College at
Uthiragidikaval village in Senthamangalam.
Dept for whom Test is carried
out : Executive Engineer,
Public Works Department,
Technical Education Division,
Trichy – 20

Sample : 40 mm HBG metal (Coarse Aggregate)

Weight of the sample : 5000 gms

Weight Cumulative Cumulative


Sl. Percentage
Sieve.Size of Weight of Weight of Remarks
No. of Passing
(mm) retained retained retained
(gm) (gm) %
1 63 mm 0 0 0 100
2 40 mm 590 585 11.8 87.9
3 20 mm 3920 4490 88.9 10.3
4 10 mm 500 5005 100.0 0.0
5 4.75 mm 0 5000 100 0
Fineness
6 2.36 mm 0 5000 100 0 Modulus
7 1.18 mm 0 5000 100 0
8 600 Micron 0 5000 100 0 = 7.90
9 300 Micron 0 5000 100 0
10 150 Micron 0 5000 100 0

PRINCIPAL
20.09.2018

DEPARTMENT OF CIVIL ENGINEERING

CONCRETE CUBE TEST

Date of Testing : 20.09.2018

Casting Date : 23.08.2018

Identification Mark : NIL

Mix : M20 Grade

Name of work : Construction of Taluk Office Building and Tashildars


Quarters at Sendamangalam in Sendamangalam Taluk
in Namakkal Dist.
Dept for whom
Test is carried out : Assistant Executive Engineer, P.W.D,
Buildings (C& M) Sub Division, Rasipuram.

No of Test Samples : 3 No .of Concrete Cube


Grade beam Concrete of with 28 days curing

S.No Size of the sample Identification Load in( N) Compressive Remarks


size in mm strength in
N/mm2
1 150X150X150 NIL 535700 23.80 28 days
2 150X150X150 NIL 528500 23.48 DO
3 150X150X150 NIL 517800 23.01 DO

PRINCIPAL

22.10.2018

DEPARTMENT OF CIVIL ENGINEERING

CONCRETE CUBE TEST

Date of Testing : 22.10.2018

Casting Date : 24.09.2018

Identification Mark : NIL

Mix : M20Grade

Name of work : Construction of Taluk Office Building and Tashlidars


Quarters at Sendamangalam in Sendamangalam Taluk
in Namakkal Dist.
Dept for whom
Test is carried out : Assistant Executive Engineer , P.W.D,
Buildings (C& M) Sub Division ,Rasipuram.

No of Test Samples : 3 No .of Concrete Cube


Roof concrete of with 28 days curing

S. No Size of the sample Identification Load in (N) Compressive Remarks


size in mm strength
N/mm2
1 150X150X150 NIL 595300 26.45 28 days
2 150X150X150 NIL 577300 25.65 DO
3 150X150X150 NIL 613400 27.26 DO

PRINCIPAL

19.07.2018

DEPARTMENT OF CIVIL ENGINEERING

TEST ON WATER

Date of Testing : 19.07.2018

Name of work : Construction of Taluk Office Building and Tashildars


Quarters at Sendamangalam in Sendamangalam Taluk
in Namakkal Dist.

Dept for whom


Test is carried out : Assistant Executive Engineer , P.W.D,
Buildings (C& M) Sub Division ,Rasipuram.

Sample : Water sample from Bore well (7).


S. NO Test Test value Permissible limit as per BIS
456:2000

1 PH - value 7-10 6-8


2 Hardness 92 ppm 75 -115 ppm
3 Chloride content 180 ppm Less than 250 ppm
4 Sulphide content 170 ppm Less than 250 ppm
5 Total dissolved solids 315 ppm Less than 500 ppm

PRINCIPAL

19.07.2018

DEPARTMENT OF CIVIL ENGINEERING

BRICKS TEST

Date of Testing : 19. 07.2018

Name of work : Construction of Taluk Office Building and Tashildars


Quarters at Sendamangalam in Sendamangalam
Taluk in Namakkal Dist.
Dept. for whom
Test is carried out : Assistant Executive Engineer, P.W.D,
Buildings (C& M) Sub Division, Rasipuram.
Sample : 3 No. of fly ash
Brick size: 83/4 “X 41/4”X23/4”

S .No Size of the sample Identification Compressive Water


size in mm On sample strength in kg/ mm2 absorption in %
1 83/4 “X 41/4”X23/4” RS 54.25 15.80
2 83/4 “X 41/4”X23/4” SELLY 53.15 14.90
3 83/4 “X 41/4”X23/4” JAI ANJANEYA 52.85 16.10

PRINCIPAL

19.07.2018

DEPARTMENT OF CIVIL ENGINEERING

SIEVE ANALYSIS OF FINE AGGREGATES (M-Sand)

Date of Testing : 19.07.2018

Name of work : Construction of Taluk Office Building and Tashildars


Quarters at Sendamangalam in Sendamangalam
Taluk in Namakkal Dist.
Dept for whom
Test is carried out : Assistant Executive Engineer, P.W.D,
Buildings (C& M) Sub Division, Rasipuram.

Sample : M-Sand (fine Aggregate)


TEST RESULT
Cumulative Cumulative
Percentage of
IS sieve size BIS limits Weight percentage of percentage of
Weight
retained Weight Weight
Retained
retained passing
10 mm 100 - - - 100
4.75 mm 90-100 200 5.0 5.0 95.0
2.36 mm 60-95 1500 29.0 34.0 66.0
1.18 mm 30-70 1600 31.0 65.0 35.0
600 µ 15-34 850 18.0 83.0 17.0
300 µ 5-20 600 11.0 94.0 6.0
150 µ 0-10 250 6.0 100 0

PRINCIPAL

19.07.2018

DEPARTMENT OF CIVIL ENGINEERING

SIEVE ANALYSIS OF FINE AGGREGATES (RIVER SAND)

Date of Testing : 19.07.2018

Name of work : Construction of Taluk Office Building and Tashildars


Quarters at Sendamangalam in Sendamangalam
Taluk in Namakkal Dist.
Dept for whom
Test is carried out : Assistant Executive Engineer, P.W.D,
Buildings (C& M) Sub Division, Rasipuram.
Sample : River Sand (fine Aggregate)

TEST RESULT
Cumulative Cumulative
Percentage of
IS sieve size BIS limits Weight percentage of percentage of
Weight
retained Weight Weight
Retained
retained passing
10 mm 100 - - - 100
4.75 mm 90-100 200 5.0 5.0 95.0
2.36 mm 60-95 1500 29.0 34.0 66.0
1.18 mm 30-70 1600 31.0 65.0 35.0
600 µ 15-34 850 18.0 83.0 17.0
300 µ 5-20 600 11.0 94.0 6.0
150 µ 0-10 250 6.0 100 0

PRINCIPAL

19.07.2018

DEPARTMENT OF CIVIL ENGINEERING

SIEVE ANALYSIS OF COARSE AGGREGATES

Date of Testing : 19.07.2018

Name of work : Construction of Taluk Office Building and Tashildars


Quarters at Sendamangalam in Sendamangalam
Taluk in Namakkal Dist.
Dept for whom
Test is carried out : Assistant Executive Engineer, P.W.D,
Buildings (C& M) Sub Division, Rasipuram.

Sample : 20mm HBG metal (Coarse Aggregate)

TEST RESULT
Cumulative Cumulative
Percentage of
IS sieve size BIS limits Weight percentage of percentage of
Weight
retained Weight Weight
Retained
retained passing
40 mm 100 - - - 100
20 mm 95-100 1150 4.60 4.60 95.4
10 mm 30-70 10700 42.80 47.60 52.6
4.75 mm 10-35 12650 50.6 98.00 20.0
2.36 mm 0-5 500 2.00 100 0

RESULTS:

Abrasion Value : 42%

Aggregate Impact value : 38%

PRINCIPAL

19.07.2018

DEPARTMENT OF CIVIL ENGINEERING

TMT STEEL ROD TESTING REPORT

Date of Testing : 19.07.2018

Name of work : Construction of Taluk Office Building and Tashildars


Quarters at Sendamangalam in Sendamangalam
Taluk in Namakkal Dist.
Dept for whom
Test is carried out : Assistant Executive Engineer, P.W.D,
Buildings (C& M) Sub Division, Rasipuram.

Specimen
Proof stress in Yield stress % of
Sl.No Specimen size in mm weight in Kg
Kg/mm2 in Kg/mm2 Elongation
for 1m
1. 8 mm 1. 468 585 21.1 0.398
2. 470 588 21.2 0.396
3. 467 586 21.5 0.397
2. 10 mm 1. 458 584 22.7 0.606
2. 462 580 21.5 0.611
3. 464 586 22.0 0.620
3. 12 mm 1. 454 559 23.0 0.884
2. 460 565 23.2 0.890
3. 470 575 23.3 0.895
4. 16 mm 1. 455 568 22.7 1.980
2. 460 555 22.1 1.990
3. 465 560 21.7 1.940
5. 20 mm 1. 453 542 23.4 2.400
2. 458 545 23.0 2.460
3. 460 548 23.2 2.480
6. 25 mm 1. 441 584 21.6 3.842
2. 450 588 21.8 3.860
3. 455 592 22.0 3.820

PRINCIPAL