You are on page 1of 2

To, T.R.No.

:- NBML/2118/2018
M/s. Agricultural Oficer Date :- 27.06.2018
Panlot Samiti Girad. Tah. Samudrapur Page No. :- 01 of 01
Dist- Wardha

Samples Description :- Concrete Cubes. Grade :- M-15


No. of Samples :- 03 Nos. Your Reference No. :- ………
Date of Samples Received :- 18.06.2018 Our Reference No. :- SRAF No. 2102 Dated 18.06.2018
Test Carried out on :- 27.06.2018 Test Method :- IS 516:1959

COMPRESSION TEST :

Avg.
Corrected
Sr. Area Weight Date of Compressive Strength Compressive
SAMPLE IDENTITY Load
No. (mm2) (gm) Casting N/mm2 Strength
(kN)
N/mm2

28 Days Cube
1 22500 8182 30.05.2018 408.6 18.2
(150x150x150) (1)

28 Days Cube
2 22500 8036 30.05.2018 395.1 17.6 18.2
(150x150x150) (2)

28 Days Cube
3 22500 8298 30.05.2018 421.0 18.7
(150x150x150) (3)

Remark- 1) Name of Village:- Girad 1/2-30.5.2018


2) Name of Work :- CNB (Intervenser)
3) The deviation of individual cube strength from the average should be within the limit of + 15 %.

…………………………………………….*** End of Report ***……………………………………………………

For, National Building Material & Steel Testing Laboratory

Mr. Pramod A. Prasad


Authorised Signatory

To, T.R.No. :- NBML/2117/2018


M/s. Agricultural Oficer Date :-19.06.2018
Panlot Samiti Girad. Tah. Samudrapur Page No. :- 01 of 01
Dist- Wardha

Samples Description :- Concrete Cubes. Grade :- M-15


No. of Samples :- 03 Nos. Your Reference No. :- ………
Date of Samples Received :- 18.06.2018 Our Reference No. :- SRAF No. 2117 Dated 18.06.2018
Test Carried out on :- 19.06.2018 Test Method :- IS 516:1959

COMPRESSION TEST :
Avg.
Corrected
Sr. Area Weight Date of Compressive Strength Compressive
SAMPLE IDENTITY Load
No. (mm2) (gm) Casting N/mm2 Strength
(kN)
N/mm2

28 Days Cube
1 22500 8182 22.05.2018 455.6 20.2
(150x150x150) (1)
28 Days Cube
2 22500 8036 22.05.2018 416.3 18.5 19.3
(150x150x150) (2)
28 Days Cube
3 22500 8298 22.05.2018 431.9 19.2
(150x150x150) (3)

Remark- 1) Name of Village:- Sawangi mirza 1/2- 22.5.2018


2) Name of Work :- CNB (Intervenser)
3) The deviation of individual cube strength from the average should be within the limit of + 15 %.

…………………………………………….*** End of Report ***……………………………………………………

For, National Building Material & Steel Testing Laboratory

Mr. Pramod A. Prasad


Authorised Signatory

You might also like