You are on page 1of 4

Made by Checked Approved

Client
DESIGN OF BEAM-COLUMN
ACCORDING TO E.C.P.2001 Date Date Date
G1 Project
30-Nov
Job no. Revision Page no.
Descript.

INTPUT
Straining actions : Cross section dimensions :

Mx = 65.00 t.m. Fy = 3.60 t/cm² D (at top) = 50.00 cm


N= -14.00 t (-ve indicates comp.) H= 9.15 m D (at bottom) = 50.00 cm
Q= 7.10 t Kx = 2.00 tw = 0.80 cm
σ =M1/M2= 0.00 Ky = 1.00 B(u.f.) = 30.00 cm (Comp.flange)
Case 1 Lu = 915.00 cm t(u.f.) = 2.50 cm (Comp.flange)
B(L.f.) = 30.00 cm
t(L.f.) = 2.50 cm
Sw = 0.50 cm

OUTPUT

Properties of section : ` For axial compression : For bending :

As = 20.28 cm² Ix (buckling) = 90762.50 cm4 a= 3.65


Y= -2.70 cm Iy (buckling) = 11251.92 cm4 α dw = 26.15
I x-x = 5.20 cm4 ix = 22.09 cm α= 0.58
Y(u.s.) = 25.00 cm iy = 7.78 cm F top = -1.87
Y(L.s.) = 25.00 cm λx = 82.84 F bottom = 1.72
Zx (u.s.) = 3630.50 cm³ λy = 117.64 ψ= -0.92
Zx (L.s.) = 3630.50 cm³ Fc = 0.54 t/cm²
I y-y = 11251.92 cm4
Zy = 750.13 cm³

Section classification :

For upper flange : C/ t f = 5.64 <=15.3/Fy^0. → Compact

For lower flange : C/ t f = 5.64 <=15.3/Fy^0.5 → Compact

For web : Compact limit = (699/Fy^0.5)/(13α-1)= 56.22


Non compact limit = (190/Fy^0.5)/(2+ψ)= 92.66

dw/tw = 56.25 → Web is non-compact

Calculation of effective section:


# Reduction of flanges : # Reduction of web :

For top flange : For bottom flange : ψ= -0.92 Bc = 23.45


ψ= 1.00 C= 15.00 C= 15.00 Kσ = 21.98 Bt = 21.55
Kσ = 0.43 λp = 0.39 λp = 0.39 b= 45.00 Be = 23.45
ρ= 1.00 ρ= 1.00 λp = 0.52 Be 1 = 9.38
Be = 15.00 Be = 15.00 ρ= 1.00 Be 2 = 14.07

Effective section properties :

Buckled part width :


Top flange 0.00 cm Aeff. = 186.00 cm²
Bottom flange 0.00 cm Y= 25.00 cm
Web 0.00 cm I x-x = 90762.50 cm4
Y(u.s.) = 25.00 cm Zx (u.s.) = 3630.50 cm³
Y(L.s.) = 25.00 cm Zx (L.s.) = 3630.50 cm³

For lateral torsional buckling :

20*bf/(fy)^.5= 316.23 Eq (2.18) ECP


1380*Af*Cb/d*Fy 1006.25 Eq (2.18) ECP Lu>limits

Cb= 1.75 84*(cb/fy)^.5= 58.57 F L.T.B.1= 2.09


rt= 8.30 188(cb/fy)^.5= 131.08 F L.T.B.2= N/A
lu/rt= 110.25 Fb= N/A F L.T.B.= N/A

Check for axial & bending :

f b(top) = -1.79 t/cm² F bcx = 2.09 t/cm² Cm = 0.85 Fc= 0.54 t/cm²
f b(bottom) = 1.79 t/cm² F btx = 2.09 t/cm² Fcx = 1.09 fca= -0.08 t/cm²
A1 = 1.00

For top Flange :


For buckling : fca / Fc + fbcx / Fbcx * A1 = 1.00 <=1 Safe

For yielding : fca / 0.58fy + fbcx / Fbcx = 0.89 <=1 Safe

For bottom Flange :


For buckling : N/A N/A N/A N/A

For yielding : -fca / 0.58fy + fbtx / Fbtx = 0.82 <=1 Safe

Check for shear :

q act = 0.20 Take Kq = 5.34 for unstiffened web

λq = 0.81
qb = 1.25 q act <= qb → Safe
Mx = 65.00 t.m. Fy = 3.60 t/cm²
N= -14.00 t (-ve indicates comp.) H= 9.15 m
Q= 7.10 t Kx = 2.00
σ =M1/M2= 0.00 Ky = 1.00
Case 1 Lu = 915.00 cm

Cross section dimensions :


D (at top) = 50.00 cm
D (at bottom) = 50.00 cm
tw = 0.80 cm
B(u.f.) = 30.00 cm
t(u.f.) = 2.50 cm
B(L.f.) = 30.00 cm `
t(L.f.) = 2.50 cm
Sw = 0.50 cm

Properties of section :

As = 186.00 cm²
Y= 25.00 cm
I x-x = 90762.50 cm4 I y-y = 11251.92 cm4
Y(u.s.) = 25.00 cm Zy = 750.13 cm³
Y(L.s.) = 25.00 cm
Zx (u.s.) = 3630.50 cm³
Zx (L.s.) = 3630.50 cm³

For axial compression :

D(at ⅔ H) = 50.00 cm²


Y= 25.00 cm A(at ⅔ H) = 186.00 cm²
Ix (buckling) = 90762.50 cm4 ix = 22.09 cm
Iy (buckling) = 11251.92 cm4 iy = 7.78 cm

λx = 82.84
λy = 117.64 → λ max = 117.64 <= 180 Safe

Fc = 0.54 t/cm²

For Bending :

a= 3.65 F top = -1.87


α dw = 26.15 F bottom = 1.72
α= 0.58 ψ= -0.92

Section classification :

For upper flange :


C/ t f = 5.64 <=15.3/Fy^0.5 → Compact

For lower flange :


C/ t f = 5.64 <=15.3/Fy^0.5 → Compact

For web :
Compact limit = (699/Fy^0.5)/(13α-1)= 56.22

Non compact limit = (190/Fy^0.5)/(2+ψ)= 92.66

dw/tw = 56.25 → Web is non-compact


Calculation of effective section:

# Reduction of flanges :

ψ= 1.00
Kσ = 0.43

For top flange :


C= 15.00 ρ= 1.00
λp = 0.39 Be = 15.00

For bottom flange :


C= 15.00 ρ= 1.00
λp = 0.39 Be = 15.00

# Reduction of web :
ψ= -0.92
Kσ = 21.98

b= 45.00 Bc = 23.45
λp = 0.52 Bt = 21.55
ρ= 1.00 Be = 23.45

Be 1 = 9.38
Be 2 = 14.07

Effective section properties :

Buckled part width : Top flange 0.00 cm


Bottom flange 0.00 cm
Web 0.00 cm

Aeff. = 186.00 cm²


Y= 25.00 cm
I x-x = 90762.50 cm4
Y(u.s.) = 25.00 cm Zx (u.s.) = 3630.50 cm³
Y(L.s.) = 25.00 cm Zx (L.s.) = 3630.50 cm³

For lateral torsional buckling :


Cb= 1.75

20*bf/(fy)^.5= 316.23 Eq (2.18) EC


1380*Af*Cb/d*Fy 1006.25 Eq (2.18) EC Lu>limits

rt= 8.30 Fb= N/A


lu/rt= 110.25 F L.T.B.1= 2.09
84*(cb/fy)^.5= 58.57 F L.T.B.2= N/A
188(cb/fy)^.5= 131.08 F L.T.B.= N/A

Check for axial & bending :

f b(top) = -1.79 t/cm² F bcx = 2.09 t/cm²


f b(bottom) = 1.79 t/cm² F btx = 2.09 t/cm²

Cm = 0.85
Fcx = 1.09 Fc= 0.54 t/cm²
A1 = 1.00 fca= -0.08 t/cm²

For top Flange : For buckling :

fca / Fc + fbcx / Fbcx * A1 = 1.00 <=1 Safe

For yielding :

fca / 0.58fy + fbcx / Fbcx = 0.89 <=1 Safe

For bottom Flange : For buckling :

N/A N/A N/A N/A

For yielding :

-fca / 0.58fy + fbtx / Fbtx = 0.82 <=1 Safe

Check for shear :

q act = 0.20 Take Kq = 5.34 for unstiffened web

λq = 0.81
qb = 1.25

q act = <= qb → Safe