Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE C* 30 PUMP
For contact details -
3/2 CC PERFORMANCE
55
visit www.warman.co.za CURVE
REFERENCE
TYPE
IMPELLER C2021 LINER
WPG
AH VANES TYPE MAT’L VANE O MAT’L
32AH10
2 OPEN METAL 214 METAL
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD
Reprinted
GLAND SEAL PUMP June 2004

Last Issue: November 2002


WE RESERVE THE RIGHT TO MODIFY OR DELETE
IMPELLERS WITHOUT PRIOR NOTICE POWER CONSUMED MAY INCREASE BY 5% WITH CENTRIFUGAL SEAL
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
48 mm
PRESENCE AND EFFECTS OF SOLIDS 2700 SPHERE

* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

60
2700
r/min 30% 35%
40%
43%
44%
50 2500 45%

46%
2300
40 45%
44%
2100 43%

Test Date: November 2002


H (m)

30
1900

1700
20
1500

10

Reference Test: RB0148

0 5 10 15 20 25

Q (l/sec)
8

2700r/min
NPSH (m)

2500r/min
4

2300r/min

2
2100r/min
Revision: 0

1900r/min
1500r/min
0