You are on page 1of 4

Index Maintenance Manuals Technical Data Drawing Information

SIZE PE* 150 PUMP


For contact details -
100
PERFORMANCE
visit www.warman.co.za CURVE
REFERENCE
TYPE
PE10147
IMPELLER CASING
WPG
PCH VANES TYPE MAT’L VANE O MAT’L
100PH30
5 CLOSED METAL 400 METAL
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD Reprinted
GLAND SEAL PUMP June 2004

Last Issue: February 2000


WE RESERVE THE RIGHT TO MODIFY OR DELETE

__ mm
IMPELLERS WITHOUT PRIOR NOTICE POWER CONSUMED MAY INCREASE BY 5% WITH CENTRIFUGAL SEAL
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
2250 SPHERE
PRESENCE AND EFFECTS OF SOLIDS
* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

140
2250 40%
50%
r/min
60%
120
65%

67%
2000

100

65%
1800
H (m)

80
60%

1600

60

1400

40

Reference Test: Curve Redrawn

20

0
0 20 40 60 80 100 120

Q (l/sec)
12
2250
r/min
NPSH (m)

4
1400
r/min
Revision: 0

0
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE PE* 150 PUMP
For contact details -
150
PERFORMANCE
visit www.warman.co.za CURVE
REFERENCE
TYPE
IMPELLER PE15147 CASING
WPG
PC VANES TYPE MAT’L VANE O MAT’L
150PC30
5 CLOSED METAL 400 METAL
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD Reprinted
GLAND SEAL PUMP June 2004
WE RESERVE THE RIGHT TO MODIFY OR DELETE

Last Issue: August 2003


___ mm
IMPELLERS WITHOUT PRIOR NOTICE POWER CONSUMED MAY INCREASE BY 5% WITH CENTRIFUGAL SEAL
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
PRESENCE AND EFFECTS OF SOLIDS 1750 SPHERE

* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

90

1750 40%
80
r/min 50%
60%
70%
70
73%

1500 76%
60

Test Date: August 2003


H (m)

73%
50

1300

40

1100
30

900
20 Reference Test: RB0254

10

0
0 20 40 60 80 100 120 140 160 180
Q (l/sec)
12
1750
r/min
NPSH (m)

4
Revision: 0

900
r/min
0
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE PF* 300 PUMP
For contact details -
150
PERFORMANCE
visit www.warman.co.za CURVE
REFERENCE
TYPE
PF150147
IMPELLER CASING
WPG
PCH VANES TYPE MAT’L VANE O MAT’L
150PH30
5 CLOSED METAL 500 METAL
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD Reprinted
GLAND SEAL PUMP June 2004
WE RESERVE THE RIGHT TO MODIFY OR DELETE

Last Issue: August 2003


__ mm
IMPELLERS WITHOUT PRIOR NOTICE POWER CONSUMED MAY INCREASE BY 5% WITH CENTRIFUGAL SEAL
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
PRESENCE AND EFFECTS OF SOLIDS 1800 SPHERE

* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

140
1800 50%
r/min 60%
65%
1700 70%
120

1600 73%
100
1500
70%

Test Date: August 2003


1400
H (m)

80

1300

60
1200

40

Reference Test: RB0255

20

0
0 50 100 150 200

Q (l/sec)
12

1800
r/min
NPSH (m)

1200
4 r/min
Revision: 0

0
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE PF* 300 PUMP
For contact details -
200
PERFORMANCE
visit www.warman.co.za CURVE
REFERENCE
TYPE
PF20147
IMPELLER CASING
WPG
PC VANES TYPE MAT’L VANE O MAT’L
200PC30
5 CLOSED METAL 500 METAL
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD Reprinted
GLAND SEAL PUMP June 2004

Last Issue: February 2000


WE RESERVE THE RIGHT TO MODIFY OR DELETE

__ mm
IMPELLERS WITHOUT PRIOR NOTICE POWER CONSUMED MAY INCREASE BY 5% WITH CENTRIFUGAL SEAL
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
PRESENCE AND EFFECTS OF SOLIDS 1400 SPHERE

* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

90

1400 50% 60% 65%


80
r/min 70%
75%
77%
70 1300

79%
60
1200
H (m)

77%
1100
50

1000
40

900
30
800

Reference Test: Curve Redrawn


700
20

10

0
0 50 100 150 200 250 300

Q (l/sec)
12

1400
NPSH (m)

8
r/min

4
Revision: 0

700