VAPOUR OR GAS
BASED ON VOLUMETRIC FLOW RATE (Nm3/min
PROCESS DATA
Vapour or Gas Relief
Fluid
Relieving Scenario
Vessel Design Code
Required Flow through the device , V Nm3/min
Gas Molecular Weight, M kg/kmol
Relief Temperature of Inlet Gas or Vapor, T °C
Compressibility, Z
Cp/Cv , k
RV Set pressure kPag
Back Pressure, P2 kPag
Back Pressure Correction Factor Kb (Default value = 1)
Coefficient from k = Cp/Cv, C
Accumulation / Overpressure . %
CALCULATIONS / RESULTS
Absolute Upstream Relieving Pressure. P 1 kPaa
Critical backpressure , Pcr kPaa
Critical flow / Subcritical flow
Type of SV
Effective coefficient of Discharge, K d
Calculated Orifice Area, A inch2
Selected Orifice
Selected Orifice Area inch2
Relieving Capacity of Selected PSV Nm3/min
2045.8
19.54
60.00 600 R
1.00
1.293
15857.94
103.42 User Input for Kb (optional):
1.00 1.00
346.28 User Input for overpressure (optional):
16 16
18496.54 2652.22972145078
10118.87
Critical Flow
Conventional
0.975 Default Value as per API-520.
2.58228 0.00400 mm2
L Refer Table 1 of API Std. 526
2.8530
2260 Nm3/hr. 135616.54
4"x 6"
L
1-Dec-21
J 1.287 2.5"X4"
PROCESS DATA
Vapour or Gas Relief
Fluid
Relieving Scenario
Vessel Design Code
Required Flow through the device , V Nm3/min
Gas Molecular Weight, M kg/kmol
Relief Temperature of Inlet Gas or Vapor, T °C
Compressibility, Z
Cp/Cv , k
RV Set pressure kPag
Back Pressure, P2 kPag
Back Pressure Correction Factor Kb (Default value = 1)
Coefficient from k = Cp/Cv, C
Accumulation / Overpressure . %
CALCULATIONS / RESULTS
Absolute Upstream Relieving Pressure. P 1 kPaa
Critical backpressure , Pcr kPaa
Critical flow / Subcritical flow
Type of SV
Effective coefficient of Discharge, K d
Calculated Orifice Area, A inch2
Selected Orifice
Selected Orifice Area inch2
Relieving Capacity of Selected PSV Nm3/min
1.00 1.00
346.28 User Input for overpressure (optional):
16 16
18496.54 2652.22972145078
10118.87
Critical Flow
Conventional
0.975 Default Value as per API-520.
1.83745 0.00285 mm2
K Refer Table 1 of API Std. 526
1.8380
1456 Nm3/hr. 87368.81
Selected Orifice Area - Calculated Orif
3"x 4" ITERACIÓN 0.00055
K
1-Dec-21
J 1.287 2.5"X4"