You are on page 1of 1

SAWAED ENGINEERING Doc. No.

-SAWAED-DPTR-03 Rev ‘0’

LIQUID PENETRANT Report No : 01


EXAMINATION REPORT Request No : 01
Page No. : 01
NDT TEST

Client: LIMAK/SWCC Project No: Location: SWCC/JUBAIL-K.S. A


Order / Draw No: 01 Mark / Item No: WJ-01 Material: CS Welded Joints
Reference procedure Specification: SAWAED-DOC-DPT-01-REV-0 Surface condition: Free from oil, spatter
Acceptance Criteria: As per ASME SEC V Surface Temp: 10°C-45°C Material Thickness:6mm to 19.05mm
Liquid Penetrant Testing Equipment WELD JOINT SKETCH
PT Technique: NDT/ASME CODE SEC V
Penetrant Type: Manufacturer:
Cleaner (PT remover): Manufacturer:
Developer: Manufacturer:
Method description
Pre - cleaning Method: Solvent Cleaning Method
Penetrant Application: Flow Check Dwell time:>10 Minutes
Developer Application: Flow Check Developing Time: 10 Minutes
Light intensity : 1000 Lux Lighting Equipment: Natural Light

Order No.
Item/Mark Joint No. Welder Tested Evaluation Result Remarks
/Draw. No No. Length(mm)

Note: P: Porosity C: Crack CP: Clustered Porosity S: Slag IP: Incomplete Penetration LF: Lack of fusion UC: Undercut

SAWAED ENGG. QA/QC WITTNESS BY/LIMAK APPROVED BY/SWCC

Name Engineer Md Sazid Alam

Signature

Checked By Engineer Ugur Berk Urkun

Date

You might also like