You are on page 1of 6

1.

Geomery
Column width b
Column depth h
Length of steel plate
Width of steel plate
Thickness of steel plate
Nail diameter
Nail head diameter
Diameter hole in steel plate
Nail Length
Nımber of nails ⊥ grain
Nımber of nails ⫽ grain
Na,l Penetration

2. Material Properties
Shear strength of glulam GL30c
Tension strength parallel to grain
Compression strenth perpendicular to grain
Density 𝝆k
Nail Tension strength
Plate yield strength (S235)
Ultimate strength

3. Modification Factors
Material factor for glulam at ULS
Material factor for glulam at ULS-Connection
Material factor for glulam at ULS-Steel
Facto for medium duration loading(service class 2)

4. Design Forces
Horizontal Force
Vertical Force
Moment

THE HORİZONTAL AND VERTİCAL FORCES ARE TAKEN AS CONTACT PRESSURE BETWEEN THE "COLUMN AND THE ST
The moment is taken as a force couple in steel plates.

The resulting force due to moment:

Steel plate buckling (EC-3 Section 6.3)


215 mm
315 mm
650 mm
200 mm
5 mm
4 mm
8 mm
d+1= 5 mm
60 mm
6
10
55 mm

3.5 Mpa
19.5 MPa
2.5 MPa
390 kg/m3
fu 600 Mpa
fyk 235 Mpa
fuk 340 Mpa

𝜸M 1.25
𝜸M,con. 1.3
𝜸M2 1.20
kmod 0.8

H= 25 kN
V= 25 kN
M= 25 kN

E "COLUMN AND THE STEEL PLATES" AND "BOTTOM OF THE COLUMN AND THE FOUNDATION" RESPECTIVELY
Fx=M/h 79 kN

𝝀 = 60/5 x √12/93.9 = 0.443

𝜱=0.5 (1+0,49x(𝝀-0.2)+𝝀^2)= 0.657

0.875

187 kN >> 79 kN No risk of buckling


N" RESPECTIVELY
risk of buckling