You are on page 1of 1

A.

GENERAL
1. OTHERWISE SHOWN OR NOTED. MODIFY TYPICAL DETAILS AS DIRECTED
TO MEET
A B C D E A B C D E A B C D E SPECIAL CONDITIONS.
2. SHOP DRAWINGS WITH ERECTION AND PLACING DIAGRAMS OF ALL
14.00 14.70 0.70
14.00 STRUCTURAL
3.00 4.00 4.00 3.00 14.00 STEEL, MISCELLANEOUS IRON, PRE-CAST CONCRETE, ETC. SHALL BE
3.00 4.00 4.00 3.00
SUBMITTED
C1F1 C1F1 C1F1 C1F1 C1F1 FOR ENGINEERS APPROVAL BEFORE FABRICATION.

0.70

0.70
WF C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 3. CONSTRUCTOR SHALL VERIFY ALL DIMENSIONS BEFORE ALL WORK IS

3
WF WF WF RB
3

B1 B1 B1 B1 RB RB RB
TO BEGIN.
S-1 S-1 CHECK WITH MECHANICAL AND ELECTRICAL CONTRACTORS FOR

WF
CONDUITS, PIPE

WF
WF
WF WF

3.00
B1 B1 B1 SLEEVES, ETC. TO BE EMBEDDED IN CONCRETE.

RB

RB

RB

RB

RB
WF
3.00

B1

B1
S-1 S-1

WF

B2

B2
4. IT SHALL BE THE CONSTRUCTOR'S RESPONSIBILITY TO PROVIDE
C1F1 C1F1 ADEQUATE
SHORINGS AND BRACINGS OF THE STRUCTURES FOR ALL LOADS THAT

5.50

5.50

5.50

6.90
C1 C1 C1 C1
5.50

100mm THK CONC. SLAB ON S-1 STAIRWELL S-1 RB MAY BE

2
RB RB RB

B2

B2
2

FILL W/ 12mm Ø HOR. BARS

WF

WF
SPACED @ 300mm O.C.B.W. IMPOSED DURING CONSTRUCTION.
B. CONCRETE AND REINFORCEMENT

B2

RB

RB

RB

RB

RB
WF

1. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM WITH THE LATEST

WF

B1

B1
2.50
S-1 S-1

B2
2.50

C1F1 C1F1 C1F1 C1F1 B1 B1 B1 BUILDING


WF WF
C1 S-1 S-1 S-1 C1 C1 C1 CODE OF AMERICAN CONCRETE INSTITUTE (ACI-318).
WF WF C1 C1 C1 C1 2. ALL CONCRETE SHALL DEVELOP A MINIMUM COMPRESSIVE STRENGTH
CB CB B1 RB RB RB RB

1
B1 CB
1

AT THE END OF TWENTY EIGHT (28) DAYS WITH CORRESPONDING

0.70

0.70
MAXIMUM SIZE
14.00 OF AGGREGATES AND SLUMPS AS FOLLOWS:
14.70 0.70 LOCATIONS 28 DAYS STRENGTH MAX. SIZE AGGREGATES MAX.
SLUMP
CURBS & SLAB 2500 PSI (17.25 MPa) 25 mm
2 x 4 x 1.5mm C-PURLINS 100 mm
TYP. SECOND AND THIRD FLOOR
SPACED @0.60m O.C. BEAMS, SUSPENDED
1 FOUNDATION PLAN 2 FRAMING PLAN SLAB, R.C. WALL
S 1 SCALE: 1:100 MTS S 1 SCALE: 1:100 MTS 3
S 1
ROOF FRAMING PLAN COLUMNS
100 mm
3000 PSI (21 MPa) 20 mm

SCALE: 1:100 MTS 3. ALL REINFORCING BARS SHALL CONFORM TO ASTM A615 GRADE 40 ( Fy
275 MPa).
COLUMN HOOPS, TIES AND STIRRUPS ARE ALL GRADE 33 BARS.
4. IN GENERAL, THE LATEST EDITION OF ACI-315 MANUAL OF STANDARD
PRACTICE IN
"L" DETAILING REINFORCED CONCRETE STRUCTURES SHALL BE ADHERED
TO UNLESS
OTHERWISE SHOWN OR NOTED.
(SEE SCHEDULE (SEE SCHEDULE
5. MAINTAIN MINIMUM CONCRETE COVER FOR REINFORCING STEEL AS
OF COLUMNS) OF COLUMNS)

FOLLOWS:

"W"
▼FFL ▼FFL SUSPENDED SLAB ------------------------------------- 20 mm
SLAB ON GRADE ------------------------------------- 40 mm
NGL
WALLS ABOVE GRADE -------------------------------- 25 mm
BEAM STIRRUPS AND COLUMN TIES ---------- 40 mm
WHERE CONC. IS EXPOSED TO EARTH
BUT POURED AGAINST FORMS -------------------50 mm

"D"

"D"
0. 25
WHERE CONC. IS DEPOSITED
"L" REBARS ALONG "W"
DIRECTION
REBARS ALONG "W"
DIRECTION
(SEE FOOTING DIRECTLY AGAINST EARTH --------------------75 mm
(SEE FOOTING SCHEDULE)
SCHEDULE)
6. ALL ANCHOR BOLTS DOWELS AND OTHER INSERTS SHALL BE PROPERLY
0.40

REBARS ALONG "L"


REBARS ALONG "L" DIRECTION
DIRECTION POSITIONED AND SECURED IN PLACE PRIOR TO PLACING OF CONCRETE.
7. CONTRACTOR SHALL NOTE AND PROVIDE ALL MISCELLANEOUS CURBS,

"W"

"T"

"T"
SILLS, TOOLS, EQUIPMENTS AND MECHANICAL BASES THAT ARE
WELL COMPACTED
WELL COMPACTED SUBGRADE REQUIRED
SUBGRADE
150mm THK. GRAVEL
BEDWELL COMPACTED
150mm THK. GRAVEL BED
WELL COMPACTED TYP. DETAIL OF COLUMN LAP SPLICES AND BY THE ARCHITECTURAL, ELECTRICAL AND MECHANICAL DRAWINGS.
8. ALL CONCRETE SHALL BE KEPT MOIST FOR A MINIMUM OF SEVEN (7)
6 EXTENSION GIRDER TO COLUMN CONNECTION CONSECUTIVE DAYS IMMEDIATELY AFTER POURING BY THE USE OF WET
S 1 BURLAP FOG SPRAYING CURING COMPOUNDS AND OTHER APPROVED
SCALE A.C.S.
METHODS.
9. STRIPPING OF FORMS AND SHORES:

4
S 1
COLUMN FOOTING DETAIL FOUNDATION --------------------------------------------- 24 HRS.
SUSPENDED SLAB EXCEPT WHEN
SCALE A.C.S. ADDITIONAL LOADS ARE IMPOSED --------------- 8 DAYS
WALLS ------------------------------------------------------ 18 HRS.
BEAMS ------------------------------------------------------ 14 DAYS
C. FOUNDATION
1. FOUNDATION IS DESIGNED FOR AN ALLOWABLE SOIL BEARING
CAPACITY OF
150 KPa ( 3,000 PSF) ASSUMED VALUE.
2. FOUNDATION SHALL REST ON NATURAL SOIL UNLESS OTHERWISE
NOTED BY
THE ENGINEER. NO PART OF THE FOUNDATION SHALL REST ON FILL.

THK.
MARK LOCATION ADDED BARS ADDED BARS
(mm) REMARKS
TYPICAL TYPICAL
CS MS CS MS

5
S 1
WALL FOOTING DETAIL S 1
7
STAIR REINFORCEMENT DETAILS
SCALE A.C.S. SCALE A.C.S.

CIVIL/STRUCTURAL ENGINEER: NOTE: PROJECT TITLE: APPROVED AS TO PLAN: REVISIONS: SHEET CONTENT: SHEET No.:
Drawings and specifications and other contract FOUNDATION PLAN
documents dully signed, stamped or sealed, as 2ND AND 3RD FLR. FRAMING PLAN

FRANKLIN M. CALE instruments of service, are the intellectual


property and documents of the architect PROPOSED FOUR STOREY APARTMENT BUILDING SCHEDULE OF COLUMN
SCHEDULE OF FOOTING
whether the object for which they are made is
CATALINA G. BALBAS SCHEDULE OF BEAMS

PRC Reg. No.: 34463 DATE ISSUED: JAN. 06, 2020


executed or not. It shall be unlawful for any
person to duplicate or make copies of said
documents for use in the repetition of and for OWNER
TYP. DETAILS
CONSTRUCTION NOTES
S-1
other projects or buildings, whether executed
PTR No.: 2609338 PLACE ISSUED: DASMA. CITY partly or in whole, without the written consent LOT 6, BLOCK 19, MAGSAYSAY ST. AFPOVAI VILLAGE , TAGUIG CITY
TIN No.: 112-118-440 CADD by: D.M.A. of the architect or author of said documents.