Customer : AHK Manual : AMM

Type : A300-600 Selected Effectivity : 006-006


Rev. Date : Jun 01, 2020

** ON A/C ALL
1. Operational Test of Smoke Detection System
A. Reason for the Job
Operational check of all smoke detection channels including associated warnings.
B. Equipment and Materials
-------------------------------------------------------------------------------
ITEM DESIGNATION
-------------------------------------------------------------------------------
Referenced Procedures
- 21-21-00, P. Block 301 Flight Compartment and Electronics Racks
Air Distribution
- 24-41-00, P. Block 301 AC External Power Control
C. Procedure
(1) Job Set-Up
(a) Energize the aircraft electrical network (Ref. AMM 24-41-00, P. Block 301 ) .
(b) Make certain that electronics racks ventilation is correct (Ref. AMM 21-21-00, P. Block 301 ) .
(c) Close overhead panel circuit breakers, particularly those associated with cargo compartment
smoke detection and ECAM.
(2) Test
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
On maintenance panel 494VU On maintenance panel 494VU
1. Place ELEC & CARGO COMPT SMOKE - TEST legend of PTT pushbutton
DET selector switch 16WA in ELEC switch comes on
COMPT/COCKPIT position
2. Press PTT pushbutton switch On panel 424VU
- AVIONICS SMOKE warning light comes
on
On CAPT and F/O main instrument
panels 3VU and 5VU.
- MASTER WARN lights come on.
Repetitive chime sounds
On ECAM DISPLAY UNIT
- message starting with SMOKE
appears

3. Release TEST pushbutton switch All annunciator lights mentioned


above go off.
Repetitive chime stops
4. Repeat actions described in steps Results are simular to those of
1, 2 & 3 above, placing test steps 1, 2 & 3 with illumina-
selector switch successively in tion and extinguishing of warning
the following positions depending light corresponding to position of
on smoke detector to be tested test selector switch. (Ref. following
(Ref. following table). table).
5. Place smoke detector test selector On maintenance panel 494VU
switch 16WA in NORM FLT position - TEST legend of PTT pushbutton
switch goes off

--------------------------------------------------------------------------------
POSITION OF TEST WARNING LIGHTS PANEL
SELECTOR SWITCH CONCERNED
--------------------------------------------------------------------------------

Print Date: July 28, 2020 Page 1 of 2


© AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Customer : AHK Manual : AMM
Type : A300-600 Selected Effectivity : 006-006
Rev. Date : Jun 01, 2020

ELEC COMPT/MAIN BAY AVIONICS SMOKE 424VU


ELEC COMPT/MIN EQPT SMOKE 22VU
(3) Close-up
(a) De-energize the aircraft electrical network (Ref. AMM 24-41-00, P. Block 301 ) .
(b) Restore system and aircraft to normal operating conditions.

End of document

Print Date: July 28, 2020 Page 2 of 2