ICC Bolting

Study online at quizlet.com/_qj7f8

1. According to the AISC Steel High-strength non- 10. According to the Code of It is marked by the
Construction Manual, the grout used shrink Standard Practice for Steel supplier - Section 5.1.1,
between the column base plate and Buildings and Bridges, how is Code of Standard
the foundation must be: steel of special material to be Practice for Steel
identified? Buildings and Bridges
2. According to the AISC Steel ⅜ inch - Table 14-2,
Construction Manual, the minimum Part 14, AISC Steel 11. According to the Code of Steel erection contractor
washer thickness for a base plate Construction Manual Standard Practice for Steel - Section 7.10.3 - Code
anchor rod 1 inch diameter is Buildings and Bridges, the of Standard Practice for
"BLANK" inches. "BLANK" is responsible for the Steel Buildings and
temporary vertical and lateral Bridges
3. According to the AISC Steel 1-13/16 inches - Table
supports necessary for the
Construction Manual, the 14-2, Part 14, AISC
erection of the building
recommended maximum size of Steel Construction
framework.
anchor rod hole in a base plate for a Manual
1 inch diameter anchor rod is 12. According to the Code of shop and erection
"BLANK" inches. Standard Practice for Steel drawings - Section 4.4.1
Buildings and Bridges, the - Code of Standard
4. According to the AISC Steel Use steel shims to
"BLANK" must be approved Practice for Steel
Construction Manual, what should be support the base
before the fabrication of the Buildings and Bridges
done if grouting is delayed on a base plate. Page 14-7, Part
structural steel begins.
plate supported by leveling nuts 14, AISC Steel
until after steel erection? Construction Manual 13. According to the Code of The number specified
Standard Practice for Steel by the ASTM
5. According to the AISC Steel treated-hardwood
Buildings and Bridges, the number specification - Section
Construction Manual, which of the shims
of samples required to be tested 5.1.1 - Code of Standard
following is not an allowed manner
for structural steel is: Practice for Steel
for setting column base plates?
Buildings and Bridges
6. According to the Code of Standard Wire Brushing -
14. According to the Code of Brushing, Rolling, or
Practice "BLANK" of the steel Section 6.5.2 - Code
Standard Practice for Steel spraying - Section 6.5.3
surface is required prior to shop of Standard Practice
Buildings and Bridges, the - Code of Standard
painting. for Steel Buildings
permitted method of applying Practice for Steel
and Bridges
shop paint is: Buildings and Bridges
7. According to the Code of Standard drift pins, grinding,
15. According to the Code of Owner's representatives
Practice for Steel Buildings and and reaming. -
Standard Practice for Steel for design and
Bridges, "BLANK" are allowed in Section 7.14 - Code
Buildings and Bridges, what party construction - Section
moderate amounts for correction of of Standard Practice
is to review the fabricators shop 4.4 -Code of Standard
errors during steel framing erection. for Steel Buildings
and erection drawings? Practice for Steel
and Bridges
Buildings and Bridges
8. According to the Code of Standard 1/16 inch - Section
16. According to the Code of Only those openings
Practice for Steel Buildings and 6.4.1 - Code of
Standard Practice for Steel shown on the contract
Bridges, "BLANK" is the tolerance on Standard Practice for
Buildings and Bridges, what types document drawings and
the length of a floor beam that is Steel Buildings and
of openings for other trades are specifications. - Section
less than 30 feet long. Bridges
allowed to be cut in the structural 7.15 - Code of Standard
9. According to the Code of Standard Certified mill test steel? Practice for Steel
Practice for Steel Buildings and reports - Section Buildings and Bridges
Bridges, how are fabricators stock 5.2.2 - Code of
17. According to the Code of Steel supplier
steel material identified? Standard Practice for
Standard Practice for Steel
Steel Buildings and
Buildings and Bridges, which party
Bridges
performs material tests of the
structural steel for verification of
material properties?
18. According to the Code of owners designated 27. According to the Model Description of discussions
Standard Practice for Steel representative for Program for Special with the contractor - Section
Buildings and Bridges, who is construction - Section 7.3 Inspection, which of the B 5 - Model Programs
responsible for the accurate - Code of Standard following items does not
location and strength of the Practice for Steel need to be included in each
foundation piers for the base Buildings and Bridges inspection report?
plates?
28. According to the A washer with arch-like
19. According to the Code of owners designated Specification for Structural protrusions on the bearing
Standard Practice for Steel representative for Joints, a direct tension surface. - Section 8.2.4 and
Buildings and Bridges, who is construction - Section 7.5.1 indicator looks like: associated commentary -
responsible for the correct - owners designated Specification for Structural
setting of the anchor rods for representative for Joints
the base plates? construction
29. According to the 71 kips
20. According to the IBC, final report. 2009 IBC, Specification for Structural
discrepancy corrections are Section1704.1.2 Joints, "BLANK" is the
made known to the building minimum bolt pretension
official by: required for an A325 bolt 1-¼
inch in diameter.
21. According to the IBC, the code official. 2009 IBC,
"blank" is the responsible for Section 1704.1 30. According to the Calibrated wrench
the approval of a person's Specification for Structural pretensioning, Oversized or
qualifications to act as a Joints, for pretensioned and slotted hole in the outer ply
special inspector. slip critical joints, which of the of the connection, or Twist-
following conditions require off type tension control
22. According to the IBC, the owner or owners agent.
washers in the high-strength bolt. - Section 6.2 -
"blank" is to hire the special 2009 IBC Section 1704.1
bolted connection? Specification for Structural
inspector.
Joints.
23. According to the IBC, which is Contractor
31. According to the When a slotted hole occurs
the first party the special
Specification for Structural in the outer ply of the joint
inspector is to notify regarding
Joints, for snug tightened and/or when the outer face
a discrepancy found during
joints, washers are required of a joint has a slope
special inspection?
only for which of the greater than 1:20 - Section
24. According to the IBC, which of Building components following conditions? 6.1 - Specification for
the following cases are where a design Structural Joints
exceptions to where special professional is not
32. According to the In a protected shelter in
inspections are required? required, Group U
Specification for Structural closed containers - Section
occupancies that are
Joints, how are the high- 2.2 - Specification for
accessory to residential
strength bolts, nuts, and Structural Joints
occupancy, or Work of a
washers to be stored at the
minor Nature
job site?
25. According to the Model In a written report -
33. According to the Bolt and nut markings -
Program for Special Inspection, Section II B 4 - Model
Specification for Structural Figure C-2.1 - Specification
the special inspector is to Programs
Joints, how can high-strength for Structural Joints
document work that is
bolts and nuts be identified
nonconforming:
on the job site?
26. According to the Model After each inspection visit
34. According to the The engineer of record's
Program for Special Inspection, - Section II B 5 - Model
Specification for Structural project drawings - Secton
the special inspector is to Programs
Joints, how does the special 2.3.1 - Specification for
prepare written report of
inspector determine the type Structural Joints
inspection:
of high-strength bolts that
are to be used for a project
or particular bolt joints?
35. According to the Manufacturer certification - 42. According to the Specification for 1-¼ inches
Specification for Structural Section 2.1 - Specification for Structural Joints, the nominal
Joints, how does the special Structural Joints diameter of an oversized bolt hole
inspector verify the bolts, for a 1 inch diameter bolt is "BLANK"
nuts, and washers meet the inches.
requirements of A325 or
43. According to the Specification for coated, uncoated,
A490 specifications?
Structural Joints, the raying surfaces or galvanized -
36. According to the Because compressible of a joint must be "blank" for proper Section 3.2.1 -
Specification for Structural material would preclude the installation of a pretensioned high- Specification for
Joints, it is important that all development of adequate strength bolt? Structural Joints
connected plies within the bolt tension - Section 3.1 -
44. According to the Specification for 1/16 inch -
grip of a high-strength bolt Specification for Structural
Structural Joints using high strength Specification for
be steel: Joints
bolts, the nominal diameter of Structural Joints
37. According to the three - Section 7.2 - standard bolt holes shall be how Table 3.1
Specification for Structural Specification for Structural much larger than the nominal bolt
Joints not fewer than "blank" Joints diameter?
complete fastener
45. According to the Specification for Checking the
assemblies of each
Structural Joints, what additional condition of faying
combination of diameter,
inspection is required for slip-critical surfaces - Sections
length and grade are to be
joints? 3.2.2 and 9.3 -
checked at the job site in the
Specification for
tension calibrator?
Structural Joints
38. According to the engineer of record - Sections
46. According to the Specification for checking for
Specification for Structural 3.3.2, 3.3.3, and 3.3.4 -
Structural Joints, what inspection task severed splined
Joints,the "blank" has the Specification for Structural
is unique to the twist-off type tension bolt ends - Section
option of approving the use Joints
control bolt pretensioning? 8.2.3 - Specification
of oversized and slotted
for Structural Joints
holes?
47. According to the Specification for Clamping force
39. According to the Calibrated wrench method
Structural Joints, what is not included from the bolt. -
Specification for Structural
in the inspection for the snug tight Section 9.1 -
Joints, the "BLANK" is an
method of installation? Specification for
allowed method for
Structural Joints
installing pretensioned
bolted joints. 48. According to the Specification for flush - Section 2.3.2
Structural Joints, what is the minimum - Specification for
40. According to the slip critical
high-strength bolt extension from the Structural Joints
Specification for Structural
outer face of the nut after
Joints, the faying surfaces of
installation?
"BLANK" joints are important
in the performance of the 49. According to the Specification for To verify the
joint when stressed. Structural Joints, what is the propose method of bolt
of tension calibrator testing of the installation has
41. According to the Checking the condition of
method of bolt installation used on achieved the
Specification for Structural the bolt and the washer from
the job site? required bolt
Joints, the inspection task storage, Checking the
tension
that is common to all of the markings on the bolts and
allowable methods of washers, and Observing the 50. According to the Specification for Snug tightened
pretensioning high-strength required pre-installation Structural Joints, what method of method
bolts is: testing for bolt tension. - installation is used for high-strength
Section 9 - Specification for bolted connections when
Structural Joints pretensioned joints are not required?
51. According to the Specification engineer of record - 59. According to the Specification for A490 and
for Structural Joints, what party Section 4.0 - Structural Joints, which of the following galvanized A325
is responsible for specifying the Specification for is true regarding reuse of high-strength bolts shall not
high-strength joint type to be Structural Joints bolts? be reused - 2.3.3
used for bolt installation? - Specification
for Structural
52. According to the Specification Snug Tightened Joints -
Joints
for Structural Joints, what type sections 7.1 & 8 -
of high-strength bolted joint Specification for 60. According to the Specification for A6
installations do not require Structural Joints Structural Steel Buildings, ASTM
tension calibrator tension Standard "BLANK" is to be used for the
verification tests? material tests to determine the type of
structural steel consisting of hot-rolled
53. According to the Specification Measuring the gap
structural shapes.
for Structural Joints, when bolts between the direct
are installed by the direct- tension indicator and the 61. According to the Specification for A36, A529, and
tension indicator, they are bolt head. - Section Structural Steel Buildings, ASTM A572 -
verified for the correct tension 8.2.4 and associated standard "blank" would apply to a Specification for
by: commentary - sample for structural steel bars. Structural Steel
Specification for Buildings
Structural Joints
62. According to the Specification for Charpy V-notch
54. According to the Specification daily - Section 8.2.2 - Structural Steel Buildings, "blank" tests testing - Section
for Structural Joints, where Specification for are required for samples for built-up A31d,
calibrated pretensioning is used, Structural Joints sections consisting of plates over 2 Specification for
how often is the installation inches in thickness. Structural Steel
wrench to be calibrated by Buildings
testing in a tension calibrator?
63. According to the Specification for ASTM A53
55. According to the Specification compressible washer Structural Steel Buildings, "BLANK
for Structural Joints, where manufacturer - Section would not apply to a sample for hot-
compressible washer type direct 2.6 - Specification for rolled steel shapes.
tension indicators are used, the Structural Joints
64. According to the Specification for Fabricator
"blank" is responsible for
Structural Steel Buildings, the "BLANK"
providing detailed installation
identifies each primary structural steel
instructions?
member, so it is placed in the correct
56. According to the Specification Periodically location in the building
for Structural Joints, where the
65. According to the Specification for Code of
turn of the nut method of bolt
Structural Steel Buildings, the document Standard Practice
installation is used, how often is
which includes the required dimensional for Steel
the special inspector to observe
tolerances for structural steel is the: Buildings and
the work as it progresses?
Bridges
57. According to the Specification bolt length - Section
66. According to the Specification for Fabricators
for Structural Joints, where twist- 2.7.2 - Specification for
Structural Steel Buildings, the special marking on the
off tension control bolts are Structural Joints
inspector can check an individual member which
used, what field inspection is of
structural steel member to see that it is matches the
primary importance for joint
the proper one for a certain location in location of that
strength?
the building by viewing the: member on the
58. According to the Specification The plane of contact shop drawings
for Structural Joints, which of the between two plies of a
67. According to the Specification for Fabricators' shop
following is the definition of a joint
Structural Steel Buildings, the type of and erection
"Faying Surface"?
drawings commonly used to verify the drawings
location of structural members and their
connections are:
68. According to the Specification A53 - Section A31a - 78. Column bases shall be set level concrete or masonry -
for Structural Steel Buildings, Specification for and to correct elevation with full AISC 16.1-148, M4
what ASTM Standard would Structural Steel Buildings bearing on: Erection 1
apply to a sample for structural
79. Compressible material shall not be within the grip -
steel pipe?
placed "blank" of the high- Section 3.1 -
69. According to the Specification milled ends strength bolt. Specification for
for Structural Steel Buildings. Structural Joints
what fabrication process is to
80. Compressible-washer-type direct ASTM
be used on column ends for a
tension indicators shall meet the
compression joint that depends
requirements of:
on contact bearing for transfer
of load? 81. Continuous inspection of bolt pre- The calibrated wrench
tensioning is required when using: method - 2009 IBC,
70. According to the Specification A36, A283, and A242 -
Section 1704.3.3.3.
for Structural Steel Buildings, Section A31a -
which ASTM standard would Specification for 82. Discrepancies in the work shall be the contractor - 2009
apply to a sample for structural Structural Steel Buildings brought to the immediate IBC, Section 1704.1.2.
steel plates? attention of the "blank" for
corrective action.
71. According to the Specifications A568 - Section A31,
for Structural Steel Buildings, Specifications for 83. Fastener components that prequalified
ASTM Standard "blank" is to be Structural Steel Buildings accumulate rust or dirt shall be
used for the material test for incorporated into the work unless
steel sheets. they are:

72. According to the Specifications Fabricator or Testing 84. Faying surfaces and surfaces Free of dirt and other
for Structural Steel Buildings, Laboratory - Section A31, adjacent to the bolt head and the foreign material -
the "blank" conducts the Specifications for nut shall be: Section 3.2 -
material tests for identification Structural Steel Buildings. Specification for
of the structural steel. Structural Joints

73. According to the Specifications Unimportant members, 85. Flat circular washers shall meet the ASTM F436 - Section
for Structural Steel Buildings, where their physical requirements of: 2.5 - Specification for
which of the following steel properties and weldability Structural Joints
members are allowed to be would not affect the 86. For twist-off tension-control bolt is at least flush with -
unidentified steel? structure strength - assemblies, when properly Section 2.7.2 -
Section A31b, installed, the end of the bolt Specification for
Specifications for "blank" the outer face of the nut. Structural Joints
Structural Steel Buildings
87. Fully inserted finger shims Are not considered a
74. The accuracy of the tension at least annually between the faying surfaces of long slotted element
calibrator shall be confirmed load-transmitting elements of of the joint
through calibration: bolted joints:
75. Alternative washer-type Engineer of Record -
indicating devices may be used Section 2.6.2 -
when approved by the: Specification for
Structural Joints
76. ASTM A490 and galvanized Shall not be reused -
ASTM A325 bolts: Section 2.3.3 -
Specification for
Structural Joints
77. At completion of fabrication The approved fabricator
"BLANK" shall submit a
certificate of compliance to the
building official
88. Given: a bolt length less than 4 times the ⅓ turn 97. In slip-critical joints, galvanizing faying hand wire
bolt diameter where both faces of the joint surfaces shall be roughened by means of: brushing -
are normal to the bolt axis. According to the Section
Specification for Structural Joints, what is the 3.2.2( C ) -
required nut rotation beyond snug tight for Specification
the turn of the nut method of installation? for Structural
Joints
89. Given: ASTM A6/A6M hot rolled shapes with Charpy V-
a flange thickness exceeding 2 inches used notch 98. Inspection of the steel frame for Member
as members subject to primary tensile Impact test compliance with the approved construction location,
forces and spliced using complete documents should verify: Bracing, and
penetration groove welds that fuse through Stiffening -
the thickness of the member. 2009 IBC,
Section
The contract documents shall require that 1704.3.2.
such shapes be supplied with "BLANK"
99. Manufacturer certification documents for Engineer of
results in accordance with ASTM A6/A6M.
all fastener components used in the Record and
90. Given a W-shape member with a 6 inch width .375 inch - fastener assemblies shall be available to the Inspector
flange and a length of 30 feet, what is the AISC 1-117 the "blank" prior to the assembly or - Section 2.1
mill straightness tolerance? Table 1-22 erection of structural steel. -
Specification
91. Given a W-shape with a "d" dimension 5/16 inch -
for Structural
exceeding 12 inches, what is the flange out AISC 1-117
Joints
of square max dimension in inches? Table 1-22
100. The minimum bolt pretension for a 1 ⅛ inch 80 kips
92. Given: bolt length is more than 4 diameters ⅔ turn
ASTM A325 HSB bolt is:
but less than 8 diameters. One face of
material is normal to the bolt axis; the other 101. Only as many fastener components as are Protected
is sloped not more than 1:20. What is the anticipated to be installed during the work storage -
required nut rotation? shift shall be taken from: Section 2.2 -
Specification
93. Heavy-Hex nuts shall meet the requirements A563 -
for Structural
of: Section 2.4.1
Joints
-
Specification 102. The permissible length variation for a ½ inch -
for W14x730 column of less than 30 feet is : AISC 1-117
Structural Table 1-22
Joints COMMENT: Total length in feet divided by
10 and multiplied by ⅛ inch
94. Identification markings for high-strength ASTM
bolts, nuts, and washers shall conform to 103. The pre-installation verification procedures Section 7;
"BLANK" standards specified in the specified in "BLANK" shall be performed equations;
approved construction documents. daily for the calibration of the installation pretension
wrench. Torque values determined from
95. Identification markings for structural steel ASTM
tables or from "BLANK" that claim to relate
shall conform to "BLANK" standards
torque to "BLANK" shall not be used.
specified in the approved construction
documents. 104. Regardless of the type of splice used, lack 1/16 inch -
of contact bearing of column compression AISC 16.1-149,
96. If the column compression joint and base non-tapered
joints and base plates is permitted provided M4 Section 4
plate gap exceeds 1/16 inch, but less than ¼ steel shims -
the gap does not exceed "BLANK" inches?
inch and an engineering investigation shows AISC M5
that sufficient contact area does not exist, 16.1-149, M4
the gap shall be packed out with "BLANK"? section 4
105. A representative sample of not fewer than three and 113. The special inspector shall provide Single-pass
"BLANK" fasteners assemblies of each 1.05 continuos inspection of: fillet welds
combination of diameter, length, and grade greater than
of bolt used in the work shall be checked at 5/16 inch in
the site of installation to verify that the size - 2099
pretensioning method develops a IBC, Table
pretension that is equal to or greater 1704.3, Item
"BLANK" times than specified. 5.3
106. The slope of the surfaces of a part in 1:20 - 114. The Specification for Structural Joints states Snug tight
contact with the bolt head and nut shall be Section 3.1 - "the tightness that is attained with a few
equal to or less than "blank" with respect to Specification impacts of an impact wrench or the full
a plane that is normal to the bolt axis. for effort of an ironworker using an ordinary
Structural spud wrench to bring the plies into firm
Joints contact." This is the description of which
method of high-strength bolt installation?
107. The snug-tightened condition is the The full
tightness that is attained with a few impacts effort of an 115. Steel bearing plates "BLANK" inches or less 2 inches -
of an impact wrench or: ironworker in thickness are permitted without milling. AISC 16.1-
using an 147, M2
ordinary Section 8 1
spud wrench
116. Steel bearing plates over 2 inches but not pressing -
108. The special inspection of the steel heating over 4 inches in thickness are permitted to AISC 16.1-
fabrication process shall not be required operations - be straightened by: 147, M2 8 1
where the fabricator does not perform any? 2009 IBC,
117. Steel furnished for structural load-carrying Identified -
Section
purposes shall be properly : 2009 IBC,
1704.3,
Section
Exceptions #
2203.1
1
118. Steel that is not readily identifiable as to tested -
109. The special inspections required by this Approved
grade by marking and test records shall be: 2009 IBC,
code are not required where the work is fabricator -
Section
done on the premise of a? 2009 IBC,
2203.1
Section
1704.2.2 119. A tension calibrator shall be used where Pretensioned
bolts are to be installed in: joints
110. The special inspector need not be Single-pass
continuously present during the welding of: fillet welds 120. Thermally cut bolt holes shall be permitted Engineer of
not if approved by the: Record -
exceeding Section 3.3 -
5/16 inch in Specification
size for
Structural
111. The special inspector shall furnish Building
Joints
inspection reports to the "blank" and to the Official and
"blank"? Registered 121. Thermally cut surfaces shall be ground Cyclically
Design smooth for: loaded
professional joints

112. The special inspector shall perform an The steel 122. Top surfaces of bearing plates need not be complete
inspection of "BLANK" to verify compliance frame milled when "BLANK" are provided joint
with the details shown on the approved between the column and the bearing plate. penetration
construction documents, such as bracing, groove
stiffening, member locations, and proper welds -
applications of joint details at each location. AISC 16.1-
147, M2
Section 8 3
123. (true or false) Fastener components True - Section 2.2 - 134. When approved alternative design ASTM A490
that accumulate rust or dirt may be Specification for fasteners are permitted in the work, such and A325 -
incorporated into the work if they Structural Joints fastener assemblies must meet the Section 2.8(1)
are requalified. materials, manufacturing, and chemical -
composition requirements of "blank" as Specification
124. Washers "BLANK" required in snug- are not
applicable. for Structural
tightened joints, except as required
Joints
in Section 6.1.1 and 6.1.2 of the
Specification for Structural Joints 135. When approved by the "blank", the use of Engineer of
alternative design fasteners is permitted. Record -
125. What is the ASTM Standard for F959 - Section 2.6.1
Section 2.8 -
compressible washer-type direct - Specification for
Specification
tension indicators? Structural Joints
for Structural
126. What is the ASTM standard for high- A325 and A490 - Joints
strength bolts? Glossary and
136. When approved by the engineer of record, ASTM A325 -
Section 2.3.1 -
black "blank" high-strength bolts are Section 2.3.3
Specification for
permitted to be reused. -
Structural Joints
Specification
127. What is the ASTM Standard for high- A563 - Section 2.4.1 for Structural
strength nuts? - Specification for Joints
Structural Joints
137. When approved by the engineer of record, in any or all
128. What is the ASTM Standard for high- F436 - Section 2.5 - short-slotted holes are permitted "blank" plies -
strength washers? Specification for of snug-tightened joints. Section 3.3.3
Structural Joints -
129. What is the "d" dimension of a 22-⅜ inch - AISC 1- Specification
W14x730 20 Table 1-1 for Structural
Joints
130. What is the design wall thickness of .465 inch - AISC 1-
an HSS 5x4x1/2 inch? 84 Table 1-11 138. When a slotted hole occur in "BLANK", an an outer ply
ASTM F436 washer or a 5/16 inch thick
131. What is the flange thickness of 4-15/16 inch - AISC
common plate washer shall be used to
W14x730 1-20 Table 1-1
cover the hole.
132. What is the maximum steel 1,100 degrees F
139. When is the code official to be made If it is not
temperature allowed to correct
aware of a discrepancy found during a corrected by
camber in an A514 structural steel
special inspection? the
beam?
contractor.
133. What is the web thickness in inches ½ inch - AISC 1-34 2009 IBC,
of a C8x18.5? Table 1-5 Section
1704.1.2
140. When the calibrated wrench pretensioning 9.2.2
method is used for installation, the
inspection shall be in accordance with
which section of the Specification for
Structural Joints?
141. When the turn of the nut pretensioning 9.2.1
method is used for installation, the
inspection shall be in accordance with
which section of the Specification for
Structural Joints?
142. Where "BLANK" is used to achieve proper position and location of the structure, the camber - AISC 16.1-143 Section L3
magnitude, direction, and location of camber shall be specified in the structural drawings.
143. Where materials or assemblies are required by this code to be labeled, such material and An approved agency - 2009 IBC,
assemblies shall be labeled by: Section 1703.5
144. Where required by the code, the building owner shall employ a registered design Structural Observation - 2009 IBC,
professional to perform: Section 1709.1
145. Which of the following reference documents has report forms? Model Programs for Special
Inspection
146. Which section of the Code of Standard Practice for Steel Buildings and Bridges includes Section 7.13 - Code of Standard
the permitted tolerances for detailed erection? Practice for Steel Buildings and
Bridges