You are on page 1of 3

Technical Prerequisites v5.

Hardware configuration

Minimum configurations Recommended configurations

Single station Single station


• PC with1 Ghzprocessor. • PC with3.2 Ghzprocessor.
• 1 Go of RAM. • 2 Go of RAM.
• 2 Go of available disk space + space necessary • 2 Go of available disk space + space necessary for
for installing MicroMaint, MiniMaint or MaxiMaint installing MicroMaint, MiniMaint or MaxiMaint SQL.
SQL. • Screen 1280 x 800
• Screen 1024 x 768
Client PC
Client PC • PC with1.8 Ghzœdual core processor.
• PC with1 Ghzprocessor. • 2 Go of RAM.
• 1 Go of RAM. • 2 Go of available disk space + space necessary for
• 500 Mo of available disk space + space installing MicroMaint, MiniMaint or MaxiMaint SQL.
necessary for installing MicroMaint, MiniMaint or • Network interface card 100 Mbits/s.
MaxiMaint SQL. • Screen 1280 x 800
• Network interface card 100 Mbits/s.
• Screen 1024 x 768 Server
• PC with3.2 Ghzdouble core processor.
Server • 4 Go of RAM.
• PC with3.2 GhzSingle Core processor • 20 Go of available disk space + space necessary
• 2 Go of RAM. for installing MicroMaint, MiniMaint or MaxiMaint SQL.
• 10 Go of available disk space + space necessary • Very fast IDE hard disk (7200 rpm) or SATA.
for installing MicroMaint, MiniMaint or MaxiMaint • Network interface card 1 Gbits/s.
SQL. • Screen 1280 x 800
• Very fast IDE hard disk (7200 rpm) or SATA.
• Network interface card 100 Mbits/s.
• Screen 1024 x 768

DIMO Maint – Head Office DIMO Maint - Tunis DIMO Maint - Paris
590, allée des Hêtres 15 rue Medinat El Azizia 56, boulevard de la mission Marchand
69760 LIMONEST 2036 Sidi Fredj 92400 COURBEVOIE
Standard 33 (0)4 72 86 01 90 La Soukra - Tunis Standard 33 (0)1 72 89 92 10
Fax 33 (0)4 72 86 01 99 +216 236 653.31 Fax 33 (0)1 72 89 92 19
www.gmao.com
Technical Prerequisites V5.0

Software Configuration
You must have a fixed IP address for the server station.

Minimum configuration Recommended configuration

Single station or network Single station or network


• Windows XP SP2. • Windows 7.
• MDAC 2.8 SP4. • MDAC 2.8 SP4.

MMaint solutions are compatible with all versions of Windows later than XP SP2,
including W2003, 2008 and 2011 Server.
Virtual environment possible: VM-Ware, etc.

Database configuration

MMaint solutions are compatible with the following databases:

• FireBird 2.1.3 (database size: 200 Mo for a database with a history of several years)
• Microsoft SQL Server 2000, 2005 and 2008R2
• Oracle 9i, 10.2g, 11g

Citrix Metaframe or TSE server configuration


For external access to the company's local network, you need a static public IP address.

Hardware configuration Recommended configuration

• PC with> 2 Ghzdouble core processor. • Windows 2003 Server with all the SP updated
• 100 Mo of RAM per active user. • Citrix Metaframe XP if Windows 2003 Server
• Fast IDE hard disk (7200 rpm) or SATA.
• 20 Go of available disk space + space necessary
for installing MicroMaint, MiniMaint or MaxiMaint SQL.
• Network interface card 100 Mbits/sor 1 Gbits/s.
• Maximum 15 users per processor.
• +/- 30 Kbits of network bandwidth available per
connected user (depending on editions).
Citrix Client Station configuration

• Graphic operating system (UNIX/LINUX, Windows 3.11, Windows 95/98, Windows NT, Windows
2000, Windows XP, Mac OS).
• If Nfuse is used, Internet browser: Mozilla Firefox 2.0 (recommended), Opera, Internet Explorer
7.
• PC type 386 minimum with8 Mo RAM and/or Macintosh.

DIMO Maint – Head Office DIMO Maint - Tunis DIMO Maint - Paris
590, allée des Hêtres 15 rue Medinat El Azizia 56, boulevard de la mission Marchand
69760 LIMONEST 2036 Sidi Fredj 92400 COURBEVOIE
Standard 33 (0)4 72 86 01 90 La Soukra - Tunis Standard 33 (0)1 72 89 92 10
Fax 33 (0)4 72 86 01 99 +216 236 653.31 Fax 33 (0)1 72 89 92 19
www.gmao.com
Technical Prerequisites V5.0

Configuration to use Web Module (Option)

• Server WEB IIS + PHP 5.2.6


or
• Server APACHE 2.2 + PHP 5.2.6

• 1 fixed IP address for the server if used as Intranet.


• 1 fixed Internet address if used via Internet (static public IP).

Configuration for use with a Mobile System

• On the PDA : Windows CE with an internet access (e.g. WIFI or GPRS access).
• Connection via the PDA on the DI/BT WEB module to manage the work.

DIMO Maint – Head Office DIMO Maint - Tunis DIMO Maint - Paris
590, allée des Hêtres 15 rue Medinat El Azizia 56, boulevard de la mission Marchand
69760 LIMONEST 2036 Sidi Fredj 92400 COURBEVOIE
Standard 33 (0)4 72 86 01 90 La Soukra - Tunis Standard 33 (0)1 72 89 92 10
Fax 33 (0)4 72 86 01 99 +216 236 653.31 Fax 33 (0)1 72 89 92 19
www.gmao.com

You might also like