Professional Documents
Culture Documents
WATER SOLUTIONS
Database Version: 28
Case #: 1 of: 1
Case Notes: Case 1
Keywords:
Information provided is offered in good faith, but without guarantees. Users of such information assume all risk and liability and expressly
release DuPont de Nemours Inc. and its subsidiaries, officers and agents from any and all liability. Because use conditions and applicable
laws may differ from one location to another and may change with time, users of information set forth herein or generated during use of
WAVE are responsible for determining suitability of the information. Neither DuPont nor its subsidiaries assume any liability for results
obtained or damages incurred from the use of information provided and TO THE FULLEST EXTENT PERMITTED BY LAW, EXPRESSLY
DISCLAIM ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE. Users will not export or re-export any information or technology received from DuPont or its subsidiaries, or the
direct products or designs based upon such information or technology in violation of the export-control or customs laws or regulations of
any country, including those of the United States of America. DuPontDuPont Oval Logo, and all products denoted with ® or are
WUDGHPDUNVRUUHJLVWHUHGWUDGHPDUNVRI'X3RQWRULWVDIILOLDWHV࣯&RS\ULJKW'X3RQW'2:(;DOWEX MONOSPHERE
DOWEX MARATHONDOWEX UPCOREare a trademark of The Dow Chemical Company used under license by DuPont.
UF Detailed Report
UF System Overview
Module Type IntegraPac IP-51
# Trains Online = 1 Standby = 1
Redundant = 0
# Modules Per Train = 14 Total = 28
System Flow Rate (m³/h) Gross Feed = 30.0 Net Product = 25.2
Train Flow Rate (m³/h) Gross Feed = 30.0 Net Product = 25.2
UF System Recovery (%) 84.55
TMP (bar) 0.32 @ 10.0 °C 0.22 @ 25.0 °C
Utility Water Forward Flush: Pretreated water Backwash: UF filtrate water
CEB Water Source: UF filtrate water CIP Water Source: UF filtrate water
UF Operating Conditions
Duration Interval Flux/Flow
Filtration: 25.0 min 28.3 min -
Instantaneous
1 Online Trains 39 LMH
2 Total Trains 20 LMH
Average 20 LMH
Net 18 LMH
Backwash 3.3 min 28.3 min 100 LMH
Acid CEB 10.6 min 336 h 100 LMH
Alkali CEB 10.6 min 168 h 100 LMH
CIP 311.8 min 90 d 1.50 m³/h
UF Water Quality
Stream Name Stream 1
Water Type Well Water (10.0 - 40.0 °C)
Feed Expected UF Product
Water Quality
Temperature (°C) 25.0 25.0
Turbidity (NTU) 30.0 чϬ͘ϭ
TDS (mg/L) 356 356
pH 7.0 7.0
UF Configuration Options
Standby Option: Constant filtrate flow, variable plant module
flux
Storage Tank Option: Storage Tank sized for BW demand only
Forward Flush Water Source: Pretreated water
BW Water Source: UF filtrate water
CEB Water Source: UF filtrate water
CIP Water Source: UF filtrate water
UF Flow Details
Stream DĂdžŝŵƵŵ&ůŽǁ࣊ Average Flow
Feed (Gross) (m³/h) 72.0 30.0
Feed Water Used for (m³/h)
Pretreatment (m³/h) 0.2
Forward Flush & Process Streams (m³/h) 1.7
Feed (Net) (m³/h) 28.1 28.1
Filtrate (Gross) (m³/h) 28.1 28.1
Filtrate Used for Cleaning (m³/h) 2.9
Filtrate (Net) (m³/h) 25.2
Air (N m³/h) 168.0 2.2
Backwash (BW) (m³/h) 71.4 2.9
Forward Flush Flowrate (m³/h) 43.5 1.7
CEB 1 (Acid) (m³/h) 71.4 0.0
CEB 2 (Alkali and/or Oxidant) (m³/h) 71.4 0.0
CIP Recycle (m³/h) 21.0 0.0
CEB Citric Acid(100%) Metering Pump (L/h) 171.5
CEB NaOH (50%) Metering Pump (L/h) 67.2
CEB NaOCl(12%) Metering Pump (L/h) 26.2
CIP HCl (32%) Metering Pump (L/h) 27.1
CIP Citric Acid(100%) Metering Pump (L/h) 252.3
CIP NaOH (50%) Metering Pump (L/h) 19.8
CIP NaOCl(12%) Metering Pump (L/h) 308.0
Footnotes:
࣊DĂdžŝŵƵŵƉŽƐƐŝďůĞĨůŽǁƌĂƚĞ
UF Pressure Ratings
Process T dDW࣊ Fouling Piping ѐP Filtrate Feed Pres. K<͍ण
Max ѐP Pres. WƌĞƐ࣎͘ Rating
(°C) (bar) (bar) (bar) (bar) (bar) (bar)
Filtration
Minimum Temp. 10.0 0.32 0.00 0.73 0.50 1.55 6.25 я
Design Temp. 25.0 0.22 0.00 0.50 0.50 1.22 6.00 я
Maximum Temp. 40.0 0.16 0.00 0.37 0.50 1.03 4.75 я
BW 25.0 0.56 0.00 0.50 1.06 6.00 я
CEB 25.0 0.56 0.00 0.50 1.06 6.00 я
CIP 35.0 2.50 2.50 5.25 я
Footnotes:
࣊ƚĂĐƚƵĂů͕ĂǀĞƌĂŐĞĨůƵdž
࣎^ƵŵŽĨdDW͕ĨŽƵůŝŶŐѐP, piping ѐP and filtrate pressure. Does not include pressure drop at the strainer. Pressure drops are based on
user inputs. Default values should not be used for pump sizing
णŽŵƉĂƌŝƐŽŶŽĨ&ĞĞĚWƌĞƐƐƵƌĞƚŽWƌĞƐƐƵƌĞZĂƚŝŶŐͶa conservative comparison due to piping losses between the feed pump and
module inlet.
UF Storage Tanks
Name Bulk Conc. Minimum Recommended Volume
(%) (m³)
tĂƚĞƌ࣊ 2.37
CIP Tank 1.37
ŚĞŵŝĐĂů^ƚŽƌĂŐĞ࣎
Citric Acid (CЋHЍOЌͿ 100% 0.012
Hydrochloric Acid (HCl) 32% 0.001
Sodium Hypochlorite (NaOCl) 12% 0.010
Sodium Hydroxide (NaOH) 50% 0.005
Footnotes:
࣊^ƚŽƌĂŐĞdĂŶŬƐŝnjĞĚƚŽŵĂŝŶƚĂŝŶĐŽŶƐƚĂŶƚŶĞƚĨŝůƚƌĂƚĞĨůŽǁ
࣎dŚĞŵŝŵŝŵƵŵƌĞĐŽŵŵĞŶĚĞĚǀŽůƵŵĞĨŽƌĐŚĞŵŝĐĂůƐƚŽƌĂŐĞƚĂŶŬƐŝƐƐŝnjĞĚĨŽƌϯϬĚĂLJƐŽĨƐƚŽƌĂŐĞ͘
UF Design Warnings
None
CEB Parameters
CEB CEB Mode Operation Chemically Enhanced Backwash (CEB) Return to
of Operation
Operation ࣏
1 2 3 4 5 6 7 8 9 10 11 1
Operating Steps Filtration ŝƌ/ŶůĞƚ࣎ Drain Backwash Backwash Soak ŝƌ/ŶůĞƚ࣎ Drain Backwash Backwash Forward Filtration
Steps Mode 1 2 1 2 &ůƵƐŚ;&&Ϳण Mode
Feed o o o
Pump
Backwash o o o o
Pump
Chem.
Dosing
Pump
CEB o o
Dosing
WƵŵƉ࣊
CIP
Recycle
Pump
Feed o o o
Valve
Pump and Filtrate o o
Valve Valve
Conditions
Conc. o o o o o o o
Valve
Backwash o o o o
Inlet
Valve
Drain o o o o
Valve
Air Inlet o o
Valve
Duration 25.0 min. 20 s 30 s 30 s 30 s 5.0 min. 20 s 30 s 30 s 30 s 60 s 25.0 min.
Flow Rate 39 LMH 12.0 N By gravity 100 LMH 100 LMH 0.0 m³/h 12.0 N By 100 LMH 100 LMH 3.1 m³/h 39 LMH
m³/h m³/h gravity
1. Frequency of CEB is based on feed water source and quality. Refer to DuPont UF Design Guidelines.
Remarks 2. For a CEB, follow Steps 2-3-4-5-6-7-8-9-10-11.
3. "o" = valve or pump is opened or operating.
࣊ŚĞŵŝĐĂůƐĂŶĚĐŽŶĐĞŶƚƌĂƚŝŽŶƐƵƐĞĚĚƵƌŝŶŐĂƌĞďĂƐĞĚŽŶĨĞĞĚǁĂƚĞƌƐŽƵƌĐĞĂŶĚƋƵĂůŝƚLJ͘ZĞĨĞƌƚŽƵWŽŶƚh&ĞƐŝŐŶ'ƵŝĚĞůŝŶĞƐ͘
࣎ŝƌĨůŽǁƌĂƚĞĚŝƐƉůĂLJĞĚŽŶƉĞƌͲŵŽĚƵůĞďĂƐŝƐ͘
Footnotes ण&ŽƌǁĂƌĚĨůƵƐŚĨůŽǁƌĂƚĞĚŝƐƉůĂLJĞĚŽŶƉĞƌͲŵŽĚƵůĞďĂƐŝƐ͘
࣏DĂLJŶĞĞĚƚŽǁĂƐƚĞĂƉŽƌƚŝŽŶŽĨƉĞƌŵĞĂƚĞƚŽƌĞŵŽǀĞƌĞƐŝĚƵĂůĐŚĞŵŝĐĂůƐ͕ĚĞƉĞŶĚŝŶŐŽŶĚĞƐŝŐŶĂŶĚĂƉƉůŝĐĂƚŝŽŶ͘
CIP Parameters
CIP CIP Mode Operation ĂĐŬǁĂƐŚ;ͬtͿ࣎ /Wण ĂĐŬǁĂƐŚ;ͬtͿ࣎ Return to
of KƉĞƌĂƚŝŽŶࣔ
Operation
1 2 3 4 5 6 7 8 9 10 11 12 13 1
Steps Filtration Air Drain Backwash Backwash Drain CIP ^ŽĂŬ࣐ CIP Drain Backwash Backwash Forward Filtration
Mode /ŶůĞƚ࣊ 1 2 ZĞĐLJĐůĞ࣏ ZĞĐLJĐůĞ࣏ 1 2 Flush Mode
;&&Ϳध
Feed o o o
Pump
o o o o
Backwash
Pump
Chem.
Dosing
Pump
CEB
Dosing
Pump
CIP o o
Recycle
Pump
Feed o o o
Valve
Pump and Filtrate o o
Valve Valve
Conditions
Conc. o o o o o o o o
Valve
o o o o
Backwash
Inlet
Valve
Drain o o o o o
Valve
Air Inlet o
Valve
Duration 25.0 min. 20 s 30 s 30 s 30 s 30 s 30.0 min. 90.0 30.0 30 s 30 s 30 s 60 s 25.0 min.
min. min.
Flow Rate 39 LMH 12.0 By 100 LMH 100 LMH By 1.5 m³/h 0.0 1.5 m³/h By 100 LMH 100 LMH 3.1 m³/h 39 LMH
N gravity gravity m³/h gravity
m³/h
1. Frequency of CIP is 1-3 months, adjusted according to operating conditions.
2. Start CIP with backwash sequence; complete CIP with backwash sequence.
Remarks 3. CIP is done manually.
4. "o" = valve or pump is opened or operating.
࣊ŝƌĨůŽǁƌĂƚĞĚŝƐƉůĂLJĞĚŽŶƉĞƌͲŵŽĚƵůĞďĂƐŝƐ͘
࣎dŚŝƐƐƚĞƉƐŚŽƵůĚďĞƌĞƉĞĂƚĞĚϮƚŝŵĞƐ͘
णdŚŝƐƐƚĞƉĂŶĚĚƵƌĂƚŝŽŶŝƐƐŚŽǁŶĨŽƌĂƐŝŶŐůĞĐŚĞŵŝĐĂůĐůĞĂŶŝŶŐ͘/ĨĂĐŝĚĂŶĚďĂƐĞĐůĞĂŶŝŶŐĂƌĞďŽƚŚƌĞƋƵŝƌĞĚ͕ƌĞƉĞĂƚ^ƚĞƉƐϲͲϭϯ͘
Footnotes ࣏/WƌĞĐLJĐůĞĨůŽǁƌĂƚĞĚŝƐƉůĂLJĞĚŽŶĂƉĞƌͲŵŽĚƵůĞďĂƐŝƐ͘
࣐dŚĞĚƵƌĂƚŝŽŶŽĨƚŚŝƐƐƚĞƉŵŝŐŚƚďĞůŽŶŐĞƌ͕ƵƉƚŽŽǀĞƌŶŝŐŚƚ;ϭϮŚŽƵƌƐͿ͕ŝĨƚŚĞĨŽƵůŝŶŐŝƐƐĞǀĞƌĞ͘
ध&ŽƌǁĂƌĚĨůƵƐŚĨůŽǁƌĂƚĞĚŝƐƉůĂLJĞĚŽŶƉĞƌͲŵŽĚƵůĞďĂƐŝƐ͘
ࣔDĂLJŶĞĞĚƚŽǁĂƐƚĞĂƉŽƌƚŝŽŶŽĨƉĞƌŵĞĂƚĞƚŽƌĞŵŽǀĞƌĞƐŝĚƵĂůĐŚĞŵŝĐĂůƐ͕ĚĞƉĞŶĚŝŶŐŽŶĚĞƐŝŐŶĂŶĚĂƉƉůŝĐĂƚŝŽŶ͘
Electricity
Peak Power (kW) 110.19
Energy (kWh/d) 43.10
Electricity Unit Cost ($/kWh) 0.0900
Electricity Cost ($/d) 3.88
Specific Energy (kWh/m³) 0.07
Chemicals
Chemical Unit Cost Dose 100% Volume Cost
($/kg) (mg/L) (L/d) ($/d)
Citric Acid (100%) 1.520 0.4 1.02
CEB1 4000
CIP 20000
HCl (32%) 0.100 0.0 0.00
CIP 480
NaOCl (12%) 0.330 0.32 0.12
CEB2 50
CIP 2000
NaOH (50%) 0.258 0.2 0.07
CEB2 717
CIP 717
Total Chemical Cost 1.21
Information provided is offered in good faith, but without guarantees. Users of such information assume all risk and liability and expressly release
DuPont de Nemours Inc. and its subsidiaries, officers and agents from any and all liability. Because use conditions and applicable laws may differ from
one location to another and may change with time, users of information set forth herein or generated during use of WAVE are responsible for
determining suitability of the information. Neither DuPont nor its subsidiaries assume any liability for results obtained or damages incurred from the
use of information provided and TO THE FULLEST EXTENT PERMITTED BY LAW, EXPRESSLY DISCLAIM ALL WARRANTIES, EXPRESSED OR IMPLIED,
INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Users will not export or re-export any information or
technology received from DuPont or its subsidiaries, or the direct products or designs based upon such information or technology in violation of the
export-control or customs laws or regulations of any country, including those of the United States of America. DuPontΡ͕DuPont Oval Logo, and all
products denoted with ® or ΡĂƌĞƚƌĂĚĞŵĂƌŬƐŽƌƌĞŐŝƐƚĞƌĞĚƚƌĂĚĞŵĂƌŬƐŽĨƵWŽŶƚŽƌŝƚƐĂĨĨŝůŝĂƚĞƐ͘෴ŽƉLJƌŝŐŚƚΞϮϬϮϬƵWŽŶƚ͘KtyΡ͕DOWEX
MONOSPHEREΡ͕DOWEX MARATHONΡ͕DOWEX UPCOREΡare a trademark of The Dow Chemical Company used under license by DuPont.