TIA Portal Template Projects


Note that you must use a TIA Portal template project when connecting to S7-PLCSIM
v13/14/15. FACTORY I/O will not be able to communicate with S7-PLCSIM
otherwise.

Setting up S7-PLCSIM with TIA Portal


1. Download and Open the template project corresponding to the TIA Portal version
and PLC family you will be simulating.
2. Save the project with a new desired name.

3. You can now write your program.

Warning

In the existing OB1 there is already a Network 1. Do not delete this network.
Otherwise the connection will not work.

1. Select the device and turn on the simulation by pressing Start Simulation.

LAB. CONTROLADORES LÓGICOS PROGRAMABLES


ING. JAIR JOSUÉ HUAMANI GABRIEL
UNIVERSIDAD NACIONAL “SAN LUIS GONZAGA” DE ICA
FACULTAD DE INGENIERIA MECANICA, ELECTRICA Y ELECTRONICA - E.A.D. INGENIERIA ELECTRONICA

2. Choose PN/IE (1) as the type of PG/PC interface and on PG/PC


interface select PLCSIM S7-1200/S7-1500 (2). Press Start search (3).
When scanning completes, select the device (4) and press Load (5).

3. On S7-PLCSIM select RUN to set the CPU to Run Mode.

LAB. CONTROLADORES LÓGICOS PROGRAMABLES


ING. JAIR JOSUÉ HUAMANI GABRIEL
UNIVERSIDAD NACIONAL “SAN LUIS GONZAGA” DE ICA
FACULTAD DE INGENIERIA MECANICA, ELECTRICA Y ELECTRONICA - E.A.D. INGENIERIA ELECTRONICA

Connecting FACTORY I/O to S7-PLCSIM


1. In FACTORY I/O click on FILE > Driver Configuration to open the Driver Window.

2. Select Siemens S7-PLCSIM on the driver drop-down list.

3. Open the driver Configuration Panel by clicking on CONFIGURATION.

LAB. CONTROLADORES LÓGICOS PROGRAMABLES


ING. JAIR JOSUÉ HUAMANI GABRIEL
UNIVERSIDAD NACIONAL “SAN LUIS GONZAGA” DE ICA
FACULTAD DE INGENIERIA MECANICA, ELECTRICA Y ELECTRONICA - E.A.D. INGENIERIA ELECTRONICA

4. Select a corresponding CPU model for your project on the Model drop-down list
(either S7-1200 or S7-1500).

5. Press Esc to return to the main driver window. Now click on CONNECT to connect
to the simulator. A successful connection is indicated by a green icon next to the
selected driver, as well as next to the driver name displayed on the status bar.